• Title/Summary/Keyword: General X-ray

Search Result 554, Processing Time 0.028 seconds

Quality Control of Upper Gastrointestinal Series(UGIS) by The Image Quality Evaluation Table of Korea and Japan (한.일 화질평가표에 의한 우리나라 위장조영검사의 품질관리)

  • Oh, Hye-Kyong;Kim, Jung-Min;Kim, Chang-Gyun;Park, Young-Seon;Seon, Jong-Ryul;Choi, In-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.277-285
    • /
    • 2011
  • To determine the quality control of UGIS, we acquired 105 patients sampling image at 21 general screening centers. The results of image quality evaluation table containing two countries's UGIS showed that the mean of image qualified education table of our country was 73.3 and the standard error was 4.49; In addition, 19 organizations of 21 general screening centers were given appropriate judgement. The average of image qualified education table of Japan was 58 and the standard error was 4.45. Only 8 organizations were given appropriate judgement. Although we made the image quality evaluation tables with same images, there were many differences in the result of two tables. We figured out the problem about the description of whole stomach and photograph skills. Furthermore, we analysed the situation of the UGIS at each general screening center with the acquired images. The biggest problem of the UGIS of our country was that the procedures were performed without clear medical methods. Methods of UGIS were different at every 21 general screening centers, and most of them did not take exam of anterior surface of stomach of the UGIS. In addition, some general screening centers did not include mucosal relief method or esophagography which is required to include in the image qualified education table of our country. Because polisography is used in the same body position, the problem occured about indiscreet exposure dose of patients. Therefore we have to make an effort to get X-ray images which have enough diagnosis information by the quality control of UGIS.

The Causes Analysis for the Number of Patients Waiting in General X-ray Room (Focus on Utilization of Quality Improvement (QI)) (일반촬영실의 환자대기건수에 대한 원인별 분석 - QI 활용을 중심으로 -)

  • Dong, Kyung-Rae;Chung, Woon-Kwan;Kim, Chang-Bok;Park, Yong-Soon;Kim, Ho-Sung;Im, In-Chul;Lee, Chang-Lae;Shin, Gyoo-Seul
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.337-346
    • /
    • 2008
  • A questionaire survey was conducted for patients who had been examined at the Department of Radiology to investigate the items that need to be improved. Brainstorming was also conducted by team members to suggest the tactics that can efficiently perform the QI activity by selecting the most frequently answered topics for the reduction of waiting time of x-ray examination. From September 2006 to November 2007, number of patients before and after conducting QI was compared for 3 months by each category differentiated by types of detailed causes. A patient case was set as one shooting for one patient. After conducting QI, the waiting cases before conducting QI were evaluated for the method of improvement for 3 month through the QI team discussion and conducted by following the improvement method for the next 1 month and the waiting cases were measured and the difference before and after the QI activity was compared in percentage. 1. When patient waiting cases were compared before and after conducting QI activity against the causes of repetition, it resulted in 3.9% of reduction effect. 2. When patient waiting cases were compared before and after conducting QI activity against the causes for the lack of guiding, it resulted in 1.1% of reduction effect. 3. When patient waiting cases were compared before and after conducting QI activity against the causes of miss-inputting prescription, it resulted in 1.1% of reduction effect. 4. When patient waiting cases were compared before and after conducting QI activity against the causes for emergency patients, patients with acute pain and discomfort patients, it resulted in 12.0% of reduction effect. 5. When patient waiting cases were compared before and after conducting QI activity against the causes for shooting overlapping of outpatients and hospitalized patients, it resulted in 4.7% of reduction effect. There are many factors to reduce the patient waiting cases in radiography. The first step is for radiology department to find these factors through QI, to improve them, which is the reason why the QI team is organized to perform the QI activities.

  • PDF

An Experimental Method for the Scatter Correction of MV Images Using Scatter to Primary Ratios (SPRs) (산란선 대 일차선비(SPR)를 이용한 MV 영상의 산란 보정을 위한 실험적 방법)

  • Jeon, Hosang;Park, Dahl;Lee, Jayeong;Nam, Jiho;Kim, Wontaek;Ki, Yongkan;Kim, Donghyun;Lee, Ju Hye;Kim, Dongwon
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.143-150
    • /
    • 2014
  • In general radiotherapy, mega-voltage (MV) x-ray images are widely used as the unique method to verify radio-therapeutic fields. But, the image quality of MV images is much lower than that of kilo-voltage x-ray images due to scatter interactions. Since 1990s, studies for the scatter correction have performed with digital-based MV imaging systems. In this study, a novel method for the scatter correction is suggested using scatter to primary ratio (SPR), instead of conventional methods such as digital image processing or scatter kernel calculations. We measured two MV images with and without a solid water phantom describing a patient body with given imaging conditions, and calculated un-attenuated ratios. Then, we obtained SPR distributions for the scatter correction. For experimental validation, a line-pair (LP) phantom using several Al bars and a clinical pelvis MV image was used. As the result, scatter signals of the LP phantom image were successfully reduced so that original density distribution of the phantom was restored. Moreover, image contrast values increased after SPR correction at all ROIs of the clinical image. The mean value of increases was 48%. The SPR correction method suggested in this study has high reliability because it is based on actually measured data. Also, this method can be easily adopted in clinics without additional cost. We expected that the SPR correction can be an effective method to improve the quality of MV image guided radiotherapy.

A Study on Projection Angles for an Optimal Image of PNS Water's View on Children (유.소아 부비강 Water's 영상의 이상적 구현을 위한 촬영기준각도 변화에 관한 연구)

  • Son, Sang-Hyuk;Song, Young-Geun;Kim, Sung-Kyu;Hong, Sang-Woo;Kim, Je-Bong
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.105-111
    • /
    • 2007
  • This study is to calculate the proper angle for the optimal image of PNS Water's view on children, comparing and analyzing the PNS Water's projection angles between children and adults at every age. This study randomly selected 50 patients who visited the Medical Center from January to May in 2005, and examined the incidence path of central ray, taking a PNS Water's and skull trans-Lat. view in Water's filming position while attaching a lead ball mark on the Orbit, EAM, and acanthion of the patients's skull. And then, we calculated the incidence angles(Angle A) of the line connected from OML and the petrous ridge to the inferior margin of maxilla on general(random) patients's skull image, following the incidence path of central ray. Finally, we analyzed two pieces of the graphs at ages, developing out the patients' ideal images at PNS Water's filming position taken by a digital camera, and calculating the angle(Angle B) between OML and IP(Image Plate). The angle between OML and IP is about $43^{\circ} in 4-years-old children, which is higher than $37^{\circ}, as age increases the angle decreases, it goes to $37^{\circ} around 30 years of age. That is similar result to maxillary growth period. We can get better quality of Water's image for children when taking the PNS Water's view if we change the projection angles, considering maxillary growth for patients in every age stage.

  • PDF

A Study of Radiation Incidence Angle in Anteroposterior Cervical Vertebra Examination (경추 정면 검사에서 방사선 입사각에 관한 연구)

  • Jeung, Seung-Woon;Lim, Cheong-Hwan;Han, Beom-Hee;Jung, Hong-Ryang;Joo, Yeong-Cheol;Park, Mi-Ja
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.83-92
    • /
    • 2012
  • In anteroposterior projection for cervical vertebra, it is general that the incidence angle of X-ray is $15^{\circ}$ to $20^{\circ}$ degrees to head in order to prevent overlap of mandible and occipital bone and to observe array of cervical interbody and shapes of joints. However, the angle is appropriate for foreigners that was determined by foreign literature review long ago, and there have been few researches of incidence angle for Koreans' body type. The purpose of in this study are to identify the incidence angle appropriate for Koreans and to present methodology. In order to measure the incidence angle, 1,044 patients who visited S Hospital located in Seosan were selected and measured of average length of cervical vertebra, OID, axis angle, and FID. The incidence angle was calculated from the applied formula by measuring average values per age groups and sex (see Formula 1 and 2). The average length of cervical vertebra was 6cm: the length was increased from teenagers to twenties but was decreased since thirties. The difference between males and females was around 1cm (p<.01). The OID was almost the same regardless of age groups and sex. As for axis angle, the slope was increased in teenagers and twenties, but was decreased since thirties. The difference between males and females was around 2 degrees (p<.01). The FID measurements were almost the same regardless of age groups and sex, and when the incidence angle was measured from these values, the teenagers were $15.9^{\circ}$, the twenties were $16.9^{\circ}$, the thirties were $16.6^{\circ}$, the forties were $16.2^{\circ}$, the fifties were $15.9^{\circ}$, and the sixties were $14.5^{\circ}$, indicating that the angle was increased from teenagers to the twenties but decreased since the thirties. While the angles of males and females were measured to be the same in the teenagers, the angle was different between males and females by $2^{\circ}$. When the incidence angle statistically analyzed with measurement of average length of cervical vertebra, OID, axis angle, and FID, all of them were shown to have correlations with the incidence angle (p<.01). Conclusively, it was shown that the incidence angle was measured differently from average length of cervical vertebra, OID, FID, and axis slope, as well as from age and sex. Therefore, it can be suggested that the anteroposterior radiation test for cervical vertebra should be conducted by different incidence angles based on age and sex. The data of this study may be used as reference in determining the incidence angle of cervical vertebra tests for the future.

Ground Security Activities for Prevention of Aviation Terrorism -Centered on San Francisco International Airport of the U.S.A.- (항공테러방지를 위한 지상 보안활동 -미국 샌프란시스코국제공항을 중심으로-)

  • Kang, Maeng-Jin;Kang, Jae-Won
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.2
    • /
    • pp.195-204
    • /
    • 2008
  • With the growth of airline management, as well as computer and IT security, the international trade in this modern society has been rapidly increasing, Along with the advancing, airplanes have become a universal means of communication. However, the complications associated with airplane safety have also been brought up as a result, the most concerning of which is terrorism. One of the main counterplans for preventing terrorism is Ground security activities the core of Ground security activities is absolute safety for passengers in both passenger terminal and freight terminal. Subastral security refers to physical protection, proximity control and 100% security search and freight guarding of the passengers' possessions, and the personnel's duties to perform such jobs are be! coming more crucial. On the other hand, Airport security check has bee n gradually developing since the 1960's, when hijacking began to take place. Although the airports have been providing more safe and comfortable services to their customers, terrorism is still happening today. When Ground security activities is minute, the users feel displeasure and discomfort, yet considering solely their convenience can brings problems in achieving safety. Since the 9.11 terror in 2001, the idea of improving and strengthening airport security was reinforced and a considerable amount of estate is being spent today for invention and application of new technology. Various nations, including the United States, have been improving their systems of security through public services; public police department is actively carrying out their duties in airports as well. In San Francisco International Airport, private police department is in charge of collection of data, national events, VIP protection, law enforcement, cooperation within facilities, daily-based patrol and traffic control. Under guidance and supervision of national organizations, such as TSA, general police department interprets X-Rays, operates metal detectors, checks passports or IDs and observes reactions to explosives. Under these circumstances, studies about advancement of cooperation and duties of general police department and private police department necessitated: especially about private police department and their training for searching equipments, decrease in number of turn over rate, invention of technology and prior settlement in estate for security. The privacy of the public, who make up the major population of airport passengers, must also be minimized. In the following research, the activities of police departments in San Francisco International Airport will be analyzed in order to understand recent actions of the United States on airport security.

Retrospective Analysis of Clinical Patterns and Antibiotic Utilization in Pediatric Patients Hospitalized with Respiratory Syncytial Virus Pneumonia at a Recently Established General Hospital (신생 대학병원에서 호흡기세포융합바이러스 폐렴으로 입원한 건강한 소아청소년환자에서의 임상 양상 및 항생제 사용에 대한 후향적 분석)

  • Hyejin So;Kyung Min Kim;Eun Young Cho
    • Pediatric Infection and Vaccine
    • /
    • v.31 no.1
    • /
    • pp.75-82
    • /
    • 2024
  • Purpose: As the coronavirus disease 2019 (COVID-19) pandemic ended, the number of patients with respiratory syncytial virus (RSV) pneumonia increased during the spring/summer of 2022. This study aimed to analyze the clinical features and antibiotic usage of children hospitalized for RSV pneumonia in a recently established general hospital in Sejong city. Methods: In this retrospective review, we included inpatients of the Pediatric Department of Chungnam National University Sejong Hospital diagnosed with RSV pneumonia between March 2022 and April 2023. Patients were divided into 2 groups: with and without antibiotic treatment. Demographic data, initial presentations, and clinical courses were reviewed. Results: A total of 116 patients with RSV pneumonia were hospitalized during this period, of which 102 were analyzed, excluding 14 with underlying diseases or who did not fall within the definition of pneumonia. The median age was 17 months. Diagnoses of bacterial infections (acute otitis media and sinusitis) were documented in 9.8% of cases. Intravenous (IV) antibiotics were administered in 46% of cases. The group receiving IV antibiotics showed higher inflammatory levels (C-reactive protein; CRP), more infiltration on initial chest X-rays, and longer fever duration. There was no difference in the length of hospitalization between the groups with and without IV antibiotics. Conclusions: This study showed a tendency for the attending physician to prescribe IV antibiotics to patients with longer fever duration, pulmonary infiltrations on the initial chest X-ray, and higher CRP levels. However, given the high rate of IV antibiotic usage compared to previous studies, care should be taken in antibiotic use.

THE EFFECTS OF IRRADIATION ON THE MANDIBULAR BONE OF RATS ON THE LOW CALCIUM DIET (방사선조사가 저칼슘식이 백서의 하악골에 미치는 영향에 관한 실험적 연구)

  • Hwang Eui-Hwan;Lee Sang-Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.2
    • /
    • pp.241-252
    • /
    • 1992
  • The purpose of this study was to investigate the changes of morphology and structure of bone tissue in the irradiated mandibular bone in rats which were fed a low calcium diet. In order to carry out this experimant, 64 seven-week old Sprague-Dawley strain rats weighing about 150gms were selected and equally divided into one experimental group of 32 rats and one control group with the remainder. The experimental group and the control group were then subdivided into two groups when the rats reached ten-week old, 16 were assigned rats for each subdivided group, exposed to irradiation. The two irradiation groups received a single dose of 20 Gy in the jaws area only and irradiated with a cobalt-60 teletherapy unit. The rats in the control and experimental groups were serially terminated by fours on the 3rd, the 7th, the 14th, and the 21st day after irradiation. Following termination, both sides of the dead rats mandibular bodies were removed and fixed with 10% neutral formalin. One side of the mandibular body was radiographed with a soft X-ray apparatus. Thereafter, the obtained microradiographs were observed by a light microscope. The remaining side of the mandibular bone was further decalcified and embedded in paraffin as using the general method. The specimen sectioned and stained with hematoxylin and eosin, and Rabit Anti-Human Tumor Necrosis Factor-a, observed by a light microscope. The obtained results were as follows: 1. Microradiogram revealed that thinning of the cortex and a decrease in the trabecula of the interradicular bone and mandibular body were observed and noted from the start to finish throughout the experiment in the non-irradiated rats on the low calcium diet rather than in the non-irradiated rats on the normal diet. In microscopic observations, there were marked osteolytic changes in the center of the bone marrow. 2. Microradiogram revealed that thinning of the cortex and a decrease in the trabecula of interradicular bone and mandibular body were more marked after 7 days in the irradiated rats on the low calcium diet rather than in the non-irradiated rats on the low clacium diet. In microscopic observations, osteoblasts were decreased markedly after 7 days, and a few osteoclasts were observed. 3. Microradiogram revealed that thinning of the cortex and a decrease in trabecula of interradicular bone and the mandibular body were more marked from the strart to finish troughout the experiment in the irradiated rats on the low calcium diet rather than in the irradiated rats on the normal diet. In microscopic observations, there were no osteolytic changes noted in the irradiated rats on the normal diet. 4. In immunocytochemical findings, a few bone marrow cells including Tumor Necrosis Factor were observed in the irradiated rats on the normal diet, but was not observed in the rats on the low calcium diet.

  • PDF

A Base Study on the Constancy Quality Control Test and Clause of Diagnosis Radiation Equipment (진단용 방사선 발생장치의 수시 정도관리 항목 및 기준에 관한 기초 연구)

  • Heo, Yeji;Kim, Kyotae;Noh, Sicheul;Nam, Sanghee;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.3
    • /
    • pp.105-110
    • /
    • 2014
  • Diagnostic radiation equipment diagnosis and treatment of disease of recent plays a central role, but this is based on the assumption of an appropriate balance of benefits and risks of diagnostic. If balance is not maintained has the potential to give an adverse effect on the health of the public. In the case of an overseas, the importance of (QA) quality assurance of medical equipment is growing, but evaluation criteria of quality assurance has not been clearly presented in domestic. Therefore, the modernization of medical equipment from the point at which the degree of cycle-by-cycle management system of foreign national to be suitable for diagnostic radiation generator entry and quality control standards by introducing a tailoring is necessary. In this study the most frequently used diagnostic radiation generator X-ray imaging apparatus of the general three-year periodic inspections at any time between the periodic inspection items and quality control methods and standards for the establishment of the United States, Canada and abroad, and international electronic literature search Technical Committee (International Electro-technical Commission, IEC) were compared with the provisions of item. Based on the national quality control items when opening frequent inspection items and standards presented as a basis for setting up study.

Removal of Cu(II) with the Recycled Hydroxylapatite from Animal Bones (동물뼈로부터 재활용된 hydroxylapatite를 이용한 Cu(II) 제거)

  • Kim, Mu-Nui;Kim, Won-Gee;Lee, Seung-Mok;Yang, Jae-Kyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.9
    • /
    • pp.735-742
    • /
    • 2009
  • The bone of spinal animals has a hydroxylapatite ($Ca_{10}(PO_4)_6(OH)_2$, HAp) structure which is well known as an excellent inorganic ion exchanger for various heavy metal ions in solutions. In this study, the reusability of cow-bone, pig-bone and fish-bone as a potential material for the removal of heavy metals in solutions was evaluated from the removal of Cu(II) ion in batch tests. The surface properties of three bones, calcined at different temperatures, were measured with SEM, XRD, FT-IR analyses. From the SEM analysis, a clear development of heterogeneity as well as pores having small diameter was observed as the calcination temperature increased. The results of X-ray diffraction analysis showed well developed crystallinity on the surface of calcined bones obtained at higher temperatures, suggesting a transform of amorphous type to crystalline type. Fourier transform infrared (FT-IR) analysis showed disappearance of water molecule on the surface of HAp and organic functional groups of the HAp with increasing the calcination temperatures. Cu(II) removal in the control test was below 15%. By the way, additional 40% increase of Cu(II) removal was observed in the presence of calcined bones. For three bones, Cu(II) removal was decreased as the calcined temperature increased. Cu(II) removal was increased as the solution pH increased due to a favorable condition for the cation exchange as well as precipitation.