• 제목/요약/키워드: General X-ray

검색결과 555건 처리시간 0.029초

新禮院粘土에 관한 基礎的 硏究 (Fundamental Studies on Sinyewon Clays)

  • 박순자;안남순;김윤호
    • 대한화학회지
    • /
    • 제10권2호
    • /
    • pp.67-75
    • /
    • 1966
  • Four kinds of clays from Sinyewon mine which is located in Chungchoungnam-Do district and two kinds of Japanese clays (Gairome, Kibushi) were selected and studied on the fundamental properties of these clays and those which are refined by the elutriation method. Chemical analysis, grading analysis such as refractoriness, specific gravity, color, fired color and plasticity, particle size distribution, various thermal tests, X-ray diffraction analysis and electron microscopic survey were carried out on these clays. The comparison of domestic clays with Japanese clays was made. 1. In chemical composition and physical properties, these four kinds of Sinyewon clays are almost similar to each other and also to Gairome and Kibushi clays. In refractoriness, Gairome and Kibushi clays have relatively high value such as SK 34 and 35, while Sinyewon clays have the value of about SK 32. Especially Sinyewon clay B has the low refractoriness (SK 18) and plasticity. Refined clays have the tendency of somewhat higher value than crude ones in refractoriness. 2. When burnt up to $900^{\circ}C$, the coefficients of contraction of Sinyewon clays were under 1.5%, Gairome under 1.3%, Kibushi under 3.0%. Only Sinyewon clay B showed expansion (1.0%) instead of contraction. 3. X-ray diffraction analysis and electron micrography showed that all of four Sinyewon clays and two Japanese clays are mainly composed of poorly crystallized kaolin, containing small amount of halloysite, sericite and considerable amount of quartz and feldspar. Sinyewon clay B contains especially large amount of quartz and feldspar. In general, it has been found out that the refined clays were free from large amount of iron oxide, quartz and feldspar.

  • PDF

준소조사면에서의 산란인자 (The Head Scatter Factor For Quasi - small Field Sizes)

  • 이상공;김진기;김정홍;김부길;권형철;김정수
    • 한국의학물리학회지:의학물리
    • /
    • 제6권2호
    • /
    • pp.13-19
    • /
    • 1995
  • 준소조사면을 대상으로 한 측정자료로부터 콜리메이터에의한 산란영향과 웨지(wedge) 사용에 따른 부가적 효과를 알아보았다. 6MV 의료용 선형가속기에서 발생된 방사선속의 중심축에서 공기중과 폴리스틸렌 팬톰, 물에대해 점리함 및 반도체검출기를 이용한 측정으로 헤드산란(위ㆍ아래 콜리메이터)의 방사선 기원과 그 크기를 결정하였다. 편평화 필터에서 형성된 산란이 대부분 윗 콜라메이터 조절에 의한 영향이 가장 크게 미침을 알수 있었다. 준소조사면에서 웨지인자(wedge factor)의 깊이에대한 영향은 웨지 각이 클수록 많은 경향을 보였고 조사변에대한 영향은 0.28%였다. 임상적으로 10 $\times$10$\textrm{cm}^2$ 이하의 준소조사면과 wedge가 부가적으로 사용되는 10cm 깊이 이하의 조사면 변화에대한 관심으로 헤드산란 및 워지에의한 영향을 확인함으로서보다 적합한 선량계산을 도모하고자 하였다.

  • PDF

경견완장애 근로자에서 작업자세와 경추이상과의 관련성 (The Relationship between Work Posture and Cervical Spine Abnormality among Cervicobrachial Disorder Workers in a Microwave-oven Assembling Factory)

  • 박종;이철갑;김영숙
    • Journal of Preventive Medicine and Public Health
    • /
    • 제29권3호
    • /
    • pp.565-577
    • /
    • 1996
  • This study was conducted to evaluate the association of work posture with cervical spine abnormality toward 106 microwave-oven assemblers. A self-administered questionnaire was used to obtain a general characteristics and a work history of workers. The posture of neck and shoulder joint of workers were measured with video tape recording and the simple X-ray of cervical spine was checked-up to observe the X-ray abnormality including degenerative change, curvature abnormality, disc space narrowing or disc canal narrowing. The result were as follows. 1. The prevalence of degenerative change among cervicobrachial disorder workers was 44.3% (47 persons), curvature abnormality was 43.4%(46 persons), disc space narrowing was 21.7%(23 persons), and disc canal narrowing was 21.7%(23 persons). 2. The prevalence of degenerative change at cervical spine was increased with the degree of neck flexion(flexed versus neutral, odds ratio [OR]=2.7), the total work posture of neck(mild or severe awkward versus neutral ; OR=1.2, 3.4). 3. The prevalence of degenerative change at cervical spine was increased with the degree of the right shoulder flexion, the heaviness of the materials carried by the right hand and the degree of awkwardness at the total work posture of right shoulder(p<0.05). 4. There was no evidence of association between curvature abnormality, disc space narrowing, disc canal narrowing and work posture. In conclusion the awkward work posture was related with degenerative change of cervical spine among microwave oven assembling workers and the further study in these field must be made to prove the association objectively.

  • PDF

Comparing Endoscopy and Upper Gastrointestinal X-ray for Gastric Cancer Screening in South Korea: A Cost-utility Analysis

  • Chang, Hoo-Sun;Park, Eun-Cheol;Chung, Woo-Jin;Nam, Chung-Mo;Choi, Kui-Son;Cho, Eun;Cho, Woo-Hyun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권6호
    • /
    • pp.2721-2728
    • /
    • 2012
  • Background: There are limited data evaluating the cost-effectiveness of gastric cancer screening using endoscopy or upper gastrointestinal x-ray in the general population. Objective: To evaluate the cost-effectiveness of population-based screening for gastric cancer in South Korea by decision analysis. Methods: A time-dependent Markov model for gastric cancer was constructed for healthy adults 30 years of age and older, and a deterministic sensitivity analysis was performed. Cost-utility analysis with multiple strategies was conducted to compare the costs and effects of 13 different screening alternatives with respect to the following eligibility criteria: age at the beginning of screening, screening interval, and screening method. The main outcome measurement was the incremental cost-effectiveness ratio. Results: The results revealed that annual endoscopic screening from ages 50-80 was the most cost-effective for the male population. In the females, biennial endoscopy screening from ages 50-80 was calculated as the most cost-effective strategy among the 12 screening alternatives. The most cost-effective screening strategy may be adjustable according to the screening costs and the distribution of cancer stage at screening. The limitation was that effectiveness data were obtained from published sources. Conclusions: Using the threshold of $19,162 per quality-adjusted life year on the basis of the Korean gross domestic product (2008), as suggested by the World Health Organization, endoscopic gastric cancer screening starting at the age of 50 years was highly cost-effective in the Korean population. The national recommendation for gastric cancer screening should consider the starting age of screening, the screening interval, and the screening modality.

비정질 실리콘 디지털 방사선 촬영기와 X-ray film과의 영상질 비교 평가 (Comparison of Image Quality of the Amorphous Silicon DR System and the Film-screen Systems)

  • 윤제웅;이형구;서태석;최보영;신경섭;문인기;김홍권;한용우;남승배
    • Journal of Radiation Protection and Research
    • /
    • 제24권3호
    • /
    • pp.161-170
    • /
    • 1999
  • 비정질 실리콘 방사선 촬영기와 기존 X-ray filmrh과의 영상질 비교를 통하여 시스템의 성능을 평가하였다. 다양한 영상질 평가를 위하여 MTF (Modulation Transfer Function), NPS (Noise Power Spectrum), Contrast를 측정하여 계산하였다. 실험 결과 DR의 MTF는 기존 film-screen system과 유사하였다. Noise 특성은 두 시스템 모두 quantum noise가 주를 이뤘으며, 특히 DR 에서는 전기적인 noise가 발견되었다. 또한 우수한 sensitivity 특성과 영상처리를 통하여 DR 시스템이 기존의 film-screen 시스템보다 놀은 대조도를 보였다. 이와 같이 DR에서는 기존 film-screen 시스템과 유사한 해상도와 영상처리를 통해 같은 촬영조건에서도 향상된 대조도의 영상을 얻을 수 있었다. 본 연구를 통하여 의학적 활용과 관련된DR 시스템의성능에 대한 유용한 정보를 제공할 수 있으리라 기대한다.

  • PDF

복식유물의 연구에 있어서 분광화학분석의 활용 (Application of Spectrochemical Analysis in the Study of Archaeological Textiles)

  • 안춘순
    • 복식
    • /
    • 제49권
    • /
    • pp.49-63
    • /
    • 1999
  • This research utilized the Energy Dispersive X-ray Spectroscopy(EDS) and the Inductively Coupled Plasma Mass Spectrometry in the analysis of chemical elements present among the textiles exhumed from Kupori Hwasung-kun Kyunggi-do. The two research objectives were: first to examine the elements present and their percent presence in Kupori samples: second to investigate whether the elements are part of mordant substances which could have been used when dyeing the KUpori textiles in the past. To meet such research purposes standard silk fabric was dyed with Sophorajaponica using alum and iron mordants. For alum mordant unpurified general alum and potassium aluminum sulfate(AlK(SO4)2). iron sulfate(FeSO4·7H2O) were used, From the results of EDS and ICP-Mass analysis the following conclusions were drawn. 1 According to the EDS analysis 9 elements Ca, S, Al, Si, K, Fe, P, Mg and Na were detected. 2. ICP-Mass result of the mordant chemicas showed high amount of A, Al and k present in alum mordants and S and Fe present in iron mordants. 3. Comparison of the ICP-Mass results of the mordant chemicals and those of the standard dyed samples suggested that the amount presence of Al and Fe is a strong indication of the usage of alum and iron mordants respecticely in an unknown dyed textile. 4, In the washed Kupori textiles Fe showed a relatively higher rate of presence in the samples Therefore it can be conjectured that those Kupori textiles were dyed with iron mordant based on the result of the above number 3. 5. It is probable that the other elements detected from the Kupori samples were incorporated into the textiles as part of the soil debris produced from the degradation of the dead within the coffin or the earth debris. They can also be part of the inorganic compounds inherent in the silk textiles themselves before dyed. 6. Among the elements it is likely that Ca which showed a high degree of presence among the unwashed samples was part of the inorganic compound inferent in the silk textiles.

  • PDF

흉부(胸部)의 X선촬영(線撮影) 및 촬영장치(撮影裝置) 현황(現況)에 관(關)한 조사(調査) (A Study on Radiographic Equipments and Situation for the Chest)

  • 고신관;안봉선
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제8권2호
    • /
    • pp.3-9
    • /
    • 1985
  • From the study on the chest radiologic equipments and situations of university hospitals, general hospitals, and radiologic clinics located in Seoul area and Choong-cheong province, the author got conclusions as follows : 1. The rectfication methods of the equipments were employing mainly single or three-phase full wave, and 78% of the examined were using single phase full wave. 2. The focal sizes in case of small focus were less than 1.0mm in chest-only use, and more than 1.0mm in 81% of combined use. The focal sizes in case of large focus were more than 1.6mm in 78% of the total. 3. Maximum ratings of x-ray tubes were 47% at 125 kVp maximum tube voltage and 41% at 150kVp. The maximum tube currentes higher than 500mA were shown in 72% of all the examined. And the maximum exposure time was the range of 5-8sec. 4. Grid was not used in the 66% of all the hospitals. Equipment for chest-only was employing 10:1 grid ratio and the 2.0-2.9mmAl of total filtration formed 38% of all the examined. 5. In the processing time of exposed film, 68% of all was 90sec, and only 20% of all the examined used optimum developing temperature according to this condition. 6. In the radiographic conditions, more than 50% used low tube voltages lower than 70 kVp and only 3% of all the equipments used high tube voltages higher than 100 kVp. The 46.9% of all the equipments 300mA, and 53% of all used shorter exposure time less than 1/20(0.05) sec. 7. In the monthly average number of radiographs, 44% of all was x-ray the radiographs.

  • PDF

동물병원의 진단용 방사선 발생장치 및 방사선종사자 안전관리 실태 조사 (Radiation safety management for diagnostic radiation generators and employees in animal hospitals in Korea)

  • 안효진;김충현;권영진;김돈환;위성환;문진산
    • 대한수의학회지
    • /
    • 제54권3호
    • /
    • pp.151-157
    • /
    • 2014
  • A nationwide survey on radiation safety management in Korean animal hospitals was conducted. By 2013, 53 radiation generators were registered as veterinary medical devices (41 X-ray generators and 12 computed tomography scanners). Additionally there were six approved laboratories for radiation equipment and protection facility, and five approved laboratories for radiation exposure of employees, respectively. By March 2013, 2,030 out of 3,829 animal hospitals operated radiation-generating devices. Among these devices, 389 (19.2%) out of 2,030 were not labeled with the model name and 746 (36.7%) were not labeled with production dates. Thus, most veterinary X-ray generators were outdated (42.6%) and needed replacements. When periodic inspections of 2,018 animal hospitals were performed after revision of the Veterinarians Act in 2011, the hospitals were found to be equipped with appropriate radiation generators and protection facilities. Among 2,545 employees exposed to radiation at the hospitals, 93.9% were veterinarians, 4.3% were animal nurse technicians, and 18% held other positions. Among 169 employees supervised by administrators, none of those had a weekly maximum operating load that exceeded $10mA{\cdot}min$. This study suggests that the radiation safety management system of animal hospitals was general good.

화어전(化瘀煎)이 조골세포 및 경골골절 유발 생쥐의 골유합에 미치는 영향 (Affirmative Effect of Hwaweo-jeon (Huayu-jian) in Osteoblast Cells and Tibia Fracture-induced Mice)

  • 이수환;;차윤엽
    • 한방재활의학과학회지
    • /
    • 제30권1호
    • /
    • pp.13-29
    • /
    • 2020
  • Objectives This study was performed to decide the bone union effect of Hwaweo-jeon on tibia fractured mice. Methods In this study, laboratory experiments were implemented by the stage of in vitro and in vivo. In in vitro, MC3T3-E1 cells were treated with various concentration of Hwaweo-jeon extract (HWJ). To investigate effect of HWJ for osteoblast, relative mRNA expression of 5 substances (alkaline phosphatase [ALP], runt-related transcription factor 2 [Runx2], osteocalcin [OCN], osterix [OSX] and collagen type II alpha 1 chain [Col2a1]) was used as a marker of osteogenesis. In order to determine HWJ's effect for fracture healing, relative gene expression level of ALP, Runx2, OCN, OSX and Col2a1 were used to find out the influence to osteoblast. Furthermore, receptor activator of nuclear factor kappa-B ligand and osteoprotegerin relative mRNA expression were used to estimate the impact to osteoclast. Also, X-ray was used for the purpose of identifying bone union in tibia-fracture mouse model. Results In in vitro experiment, most part of relative mRNA expression were increased compared to control group. In in vivo and in vitro experiment, HWJ induced osteoblast activitation by verifying relative mRNA expression of 5 substances. And in vivo experiment, we can also identify that HWJ triggered osteoclast activation during early stage of tibia fracture. Furthermore, X-ray pictures show noticeable recovery of tibia fracture. Conclusions HWJ extract promotes bone union by facilitating the osteoblast. But, HWJ may occur liver & kidney toxicity over specific concentration. Therefore, when HWJ is applied to human body, doctors have to follow up the liver function test & renal function test of patient.

Sol-gel 법을 이용한 코어-쉘 실리카-형광체의 제조 및 특성평가 (Synthesis and Characterization of Core-Shell Silica-Phosphor Nanoparticles via Sol-Gel Process)

  • 신원호;김세윤;정형모
    • 한국분말재료학회지
    • /
    • 제25권1호
    • /
    • pp.12-18
    • /
    • 2018
  • Cost-effective functional phosphor nanoparticles are prepared by introducing low-cost $SiO_2$ spheres to rare-earth phosphor ($YVO_4:Eu^{3+}$, $YVO_4:Er^{3+}$, and $YVO_4:Nd^{3+}$) shells using a sol-gel synthetic method. These functional nanoparticles are characterized by X-ray diffraction, X-ray photoelectron spectroscopy, transmission electron microscopy, and general photoluminescence spectra. The $SiO_2$ sphere occupying the interior of the conventional phosphor is advantageous in significantly reducing the cost of expensive rare-earth phosphor nanoparticles. The sol-gel process facilitates the core-shell structure formation; the rare-earth shell phosphor has strong interactions with chelating agents on the surfaces of $SiO_2$ nanoparticles and thus forms layers of several nanometers in thickness. The photoluminescence wavelength is simply tuned by replacing the active materials of $Eu^{3+}$, $Er^{3+}$, and $Nd^{3+}$. Moreover, the photoluminescent properties of the core-shell nanoparticles can be optimized by manipulating the specific contents of active materials in the phosphors. Our simple approach substitutes low-cost $SiO_2$ for expensive rare-earth-based phosphor materials to realize cost-effective phosphor nanoparticles for various applications.