• 제목/요약/키워드: Geant4 simulation

검색결과 129건 처리시간 0.024초

Development of a muon detector based on a plastic scintillator and WLS fibers to be used for muon tomography system

  • Chanwoo Park;Kyu Bom Kim;Min Kyu Baek;In-soo Kang;Seongyeon Lee;Yoon Soo Chung;Heejun Chung;Yong Hyun Chung
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.1009-1014
    • /
    • 2023
  • Muon tomography is a useful method for monitoring special nuclear materials (SNMs) such as spent nuclear fuel inside dry cask storage. Multiple Coulomb scattering of muons can be used to provide information about the 3-dimensional structure and atomic number(Z) of the inner materials. Tomography using muons is less affected by the shielding material and less harmful to health than other measurement methods. We developed a muon detector for muon tomography, which consists of a plastic scintillator, 64 long wavelength-shifting (WLS) fibers attached to the top of the plastic scintillator, and silicon photomultipliers (SiPMs) connected to both ends of each WLS fiber. The muon detector can acquire X and Y positions simultaneously using a position determination algorithm. The design parameters of the muon detector were optimized using DETECT2000 and Geant4 simulations, and a muon detector prototype was built based on the results. Spatial resolution measurement was performed using simulations and experiments to evaluate the feasibility of the muon detector. The experimental results were in good agreement with the simulation results. The muon detector has been confirmed for use in a muon tomography system.

GATE 시뮬레이션을 사용한 알루미늄 부가필터 두께에 따른 Digital Radiography의 영상 화질 비교 평가 (Comparison Evaluation of Image Quality with Different Thickness of Aluminum added Filter using GATE Simulation in Digital Radiography)

  • 오민주;홍주완;이영진
    • 한국방사선학회논문지
    • /
    • 제13권1호
    • /
    • pp.81-86
    • /
    • 2019
  • X-선 영상에서 필터를 통한 여과의 역할은 영상 형성에 유용한 광자를 이용해 환자의 피폭량을 낮춤과 동시에 영상의 대조도를 높이는 것이다. 영상을 형성하는 데 있어서 저에너지 X-선은 환자 조직의 최초 몇 cm 부위에서 흡수되고 고에너지 부분만을 통과하여 형성되므로, 방사선 여과는 여과물질을 삽입하여 저에너지 X-선을 여과물질로 하여금 흡수시켜 환자의 피폭량을 낮추고 영상의 질을 높인다. 본 연구의 목적은 시뮬레이션을 통해 이상적인 환경에서 부가 필터가 방사선 영상 촬영 시 영상의 화질에 미치는 영향을 확인하고, 실제 방사선 영상을 촬영할 경우와 비교하는 것이다. 이를 위해 시뮬레이션 프로그램인 Geant4 Application for Tomographic Emission (GATE)를 이용해 Polymethylmethacrylate (PMMA) Phantom의 실제 크기, 모양과 재질을 모사하고 부가 필터의 사용유무 및 필터의 두께에 따른 촬영 조건을 설정하여 시뮬레이션 결과 영상을 얻어냈다. 또한, Digital Radiography (DR)장비로 실제 PMMA Phantom을 필터가 없는 경우와 필터가 있을 때 그 두께를 변화시키며 촬영했다. 시뮬레이션의 결과 영상과 실제 실험을 통해 얻은 영상을 각각 Image J 프로그램을 이용해 Contrast-to-noise ratio (CNR) 평가를 실행한 뒤, 시뮬레이션 결과 영상과 최종적으로 도출된 두 영상의 변화 추이를 비교 측정했다. 실험 결과 DR장비와 시뮬레이션 영상 모두 CNR이 감소하는 추세를 보였으며, 이는 결국 영상에서의 대조도 감소로 인해 나타난 결과였다. 이론적으로 관전압 (kVp)이 증가하면 대조도가 감소하고, 이를 통해보았을 때 필터는 저에너지부의 X-선을 흡수하면서 전체적인 선량을 감소시키지만, X-선의 평균에너지를 증가시키는 역할을 한다는 것을 알아볼 수 있었다.

4-D 전산모사 기법을 이용한 호전형 컴프턴 카메라의 영상 특성 평가 (Image Quality of a Rotating Compton Camera Evaluated by Using 4-D Monte Carlo Simulation Technique)

  • 서희;이세형;박진형;김찬형;박성호;이주한;이춘식;이재성
    • Journal of Radiation Protection and Research
    • /
    • 제34권3호
    • /
    • pp.107-114
    • /
    • 2009
  • 컴프턴 카메라는 컴프턴 산란 현상에 기반을 둔 감마선 영상장치로 기존의 영상장치가 가지는 여러 가지 한계점들을 극복할 수 있어서 차세대 영상장치로 관심을 받고 있다. 본 연구에서는 4-D 전산모사 기법을 이용하여 회전형 컴프턴 카메라의 영상 특성을 평가하였으나, 원자력 산업용으로 활용될 수 있는 컴프턴 카메라에 대하여 가능성을 확인하여 보았다. 고정된 시스템 보다는 선원 주위를 회전하여 영상을 획득할 경우 선원의 위치 및 분포를 상대적으로 정확하게 결정할 수 있음을 확인하였다. 또한, 컴프턴 카메라의 3차원 영상가능을 통해 대형 원자력 시설해체 시 콘크리트 벽안에 존재하는 방사화된 철근구조의 위치 및 분포를 한 쪽 벽면에서 정확히 결정할 수 있음을 확인하였다. 본 연구에서 활용한 4-D 전산모사 기법은 컴프턴 카메라 분야에 최초로 적용된 기술이며, 이는 움직이는 장기 및 LINAC 켄트리, 4-D CT 등 동적 구조에 대한 모델링이 가능하므로 다양한 응용분야에서 활용될 수 있을 것으로 기대한다.

Conceptual Design of a Solid State Telescope for Small scale magNetospheric Ionospheric Plasma Experiments

  • Sohn, Jongdae;Lee, Jaejin;Jo, Gyeongbok;Lee, Jongkil;Hwang, Junga;Park, Jaeheung;Kwak, Young-Sil;Park, Won-Kee;Nam, Uk-Won;Dokgo, Kyunghwan
    • Journal of Astronomy and Space Sciences
    • /
    • 제35권3호
    • /
    • pp.195-200
    • /
    • 2018
  • The present paper describes the design of a Solid State Telescope (SST) on board the Korea Astronomy and Space Science Institute satellite-1 (KASISat-1) consisting of four [TBD] nanosatellites. The SST will measure these radiation belt electrons from a low-Earth polar orbit satellite to study mechanisms related to the spatial resolution of electron precipitation, such as electron microbursts, and those related to the measurement of energy dispersion with a high temporal resolution in the sub-auroral regions. We performed a simulation to determine the sensor design of the SST using GEometry ANd Tracking 4 (GEANT4) simulations and the Bethe formula. The simulation was performed in the range of 100 ~ 400 keV considering that the electron, which is to be detected in the space environment. The SST is based on a silicon barrier detector and consists of two telescopes mounted on a satellite to observe the electrons moving along the geomagnetic field (pitch angle $0^{\circ}$) and the quasi-trapped electrons (pitch angle $90^{\circ}$) during observations. We determined the telescope design of the SST in view of previous measurements and the geometrical factor in the cylindrical geometry of Sullivan (1971). With a high spectral resolution of 16 channels over the 100 keV ~ 400 keV energy range, together with the pitch angle information, the designed SST will answer questions regarding the occurrence of microbursts and the interaction with energetic particles. The KASISat-1 is expected to be launched in the latter half of 2020.

Particle loading as a design parameter for composite radiation shielding

  • Baumann, N.;Diaz, K. Marquez;Simmons-Potter, K.;Potter, B.G. Jr.;Bucay, J.
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3855-3863
    • /
    • 2022
  • An evaluation of the radiation shielding performance of high-Z-particle-loaded polylactic acid (PLA) composite materials was pursued. Specimens were produced via fused deposition modeling (FDM) using copper-PLA, steel-PLA, and BaSO4-PLA composite filaments containing 82.7, 75.2, and 44.6 wt% particulate phase contents, respectively, and were tested under broad-band flash x-ray conditions at the Sandia National Laboratories HERMES III facility. The experimental results for the mass attenuation coefficients of the composites were found to be in good agreement with GEANT4 simulations carried out using the same exposure conditions and an atomistic mixture as a model for the composite materials. Further simulation studies, focusing on the Cu-PLA composite system, were used to explore a shield design parameter space (in this case, defined by Cu-particle loading and shield areal density) to assess performance under both high-energy photon and electron fluxes over an incident energy range of 0.5-15 MeV. Based on these results, a method is proposed that can assist in the visualization and isolation of shield parameter coordinate sets that optimize performance under targeted radiation characteristics (type, energy). For electron flux shielding, an empirical relationship was found between areal density (AD), electron energy (E), composition and performance. In cases where ${\frac{E}{AD}}{\geq}2MeV{\bullet}cm{\bullet}g^{-1}$, a shield composed of >85 wt% Cu results in optimal performance. In contrast, a shield composed of <10 wt% Cu is anticipated to perform best against electron irradiation when ${\frac{E}{AD}}<2MeV{\bullet}cm{\bullet}g^{-1}$.

이중 적층 구조 표적을 갖는 투과형 엑스선관의 몬테카를로 전산모사 (Monte Carlo Simulation of Transmission-Type X-ray Tube with Dual-Structured Target)

  • 천권수
    • 한국방사선학회논문지
    • /
    • 제17권1호
    • /
    • pp.107-114
    • /
    • 2023
  • 엑스선형광분석은 비파괴적으로 시료에 포함된 원소와 농도를 분석할 수 있는 기법으로 과학 및 산업 분야에 광범위하게 사용되고 있다. 다양한 물질을 포함한 혼합물 또는 화합물 분석의 정밀도 향상을 위해 10 keV 근방의 저에너지와 20 keV 근방의 에너지 영역에 높은 강도 분포를 갖는 엑스선관이 요구된다. 두 에너지 영역에서 높은 강도 분포를 갖는 스펙트럼을 얻기 위하여 9.65 keV의 특성엑스선을 가지는 텅스텐과 17.48 keV의 몰리브덴 두 물질을 적층한 구조의 표적을 가지는 투과형 엑스선관을 몬테카를로 전산모사를 통해 스펙트럼을 분석하였다. W-Mo 구조의 표적을 통해 10 keV와 20 keV 근방의 강한 강도를 갖는 특성엑스선을 얻었다. 또한 4 ㎛ 두께의 Mo-W multilayers 구조의 표적을 통해 최적의 강도 분포를 갖는 스펙트럼을 얻을 수 있음을 확인하였다. 다양한 표적 물질을 선택 조합하고 두께 최적화를 통해 원하는 에너지 대역에서 높은 강도 분포를 갖는 스펙트럼을 얻는 것이 가능하다.

구형의 섬광체를 이용한 방사선 스펙트로스코피 검출기 설계 및 방사선원 위치 추적 시스템 개발 (Design of a Radiation Spectroscopy Detector using a Spherical Scintillator and Development of a Radiation Source Position Tracking System)

  • 이승재
    • 한국방사선학회논문지
    • /
    • 제14권6호
    • /
    • pp.725-731
    • /
    • 2020
  • 구(sphere)형의 섬광체를 사용한 방사선 스펙트로스코피 검출기를 설계하였고, 여러 대의 검출기를 사용하여 방사선원의 위치를 추적하는 시스템을 개발하였다. 방사선원의 위치 추적은 방사선의 수는 거리의 역자승 법칙에 따라 감소하는 이론을 바탕으로 위치 추적 알고리듬을 설계하였으며, 여러 위치의 방사선원에서 발생된 방사선의 수를 측정하여 알고리듬을 통해 위치를 계산하였다. 방사선원에서 발생되는 방사선은 각 검출기에서 서로 다른 계수로 검출되며, 이러한 검출되는 계수의 차이는 거리의 역자승에 비례하여 달라진다. 설계한 방사선원 위치 추적 시스템의 성능을 검증 및 평가하기 위해 Geant4 Application for Tomographic Emission (GATE) 시뮬레이션을 실시하였으며, 서로 다른 위치에 놓이 방사선원에서 발생된 방사선을 각 검출기로 계수하였다. 측정된 방사선의 수는 방사선원 위치 추적 알고리듬을 통해 위치가 추적되었으며, 실제 방사선원의 위치와 알고리듬으로 계산된 위치와의 오차를 평가하였다. 실제 방사선원의 위치와 계산된 위치와의 오차는 평균 X축 0.11%, Y축 0.37%로 측정되었으며, 매우 정확하게 위치를 측정할 수 있음이 검증되었다.

400 MeV/u 탄소 이온에 대한 방사선치료 선량 측정용 고체비적검출기의 교정 (Calibration of CR-39 for Hadron Radiotherapy using 400 MeV/u C ions)

  • 김성환;남욱원;이재진;박원기;표정현;문봉곤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권1호
    • /
    • pp.43-49
    • /
    • 2016
  • 본 연구에서는 탄소이온을 이용한 고LET 방사선 치료시 CR-39 고체비적검출기(SSNTD)를 선량계로 사용하기 위하여 일본 중입자가속기연구소(HIMAC)의 400 MeV/u 탄소 이온을 이용한 교정실험을 수행하였다. 탄소 이온을 조사한 CR-39 검출기는 일본 우주항공연구개발기구(JAXA)의 고체비적검출기 전처리 프로토콜에 따라 화학적 에칭을 하였고, 에칭된 CR-39 검출기의 표면에 형성된 트랙은 디지털 카메라로 촬영한 후 Image J를 이용하여 분석하였다. 분석결과 400 MeV/u 탄소 이온의 ${\bar{y_F}}$${\bar{y_D}}$는 각각 $8.5keV/{\mu}m$$10.1keV/{\mu}m$이었으며, 이 결과는 한국천문연구원의 조직등가비례계수기(TEPC)로 측정한 값 및 GEANT4 몬테칼로 시뮬레이션으로 계산한 값과 잘 일치하였다. 본 연구를 통하여 CR-39의 선량 및 LET 교정인자를 결정할 수 있었으며, 고LET 방사선 치료시 CR-39를 이용한 선량평가의 가능성을 확인하였다.

엑스선 에너지스펙트럼 변경을 통한 영상 화질 향상에 관한 연구 (Image Quality Improvement through Energy Spectrum Change for X-ray)

  • 김구;김능균;이승재
    • 한국방사선학회논문지
    • /
    • 제15권1호
    • /
    • pp.71-78
    • /
    • 2021
  • 엑스선 영상을 획득하는 경우에 연속 엑스선을 사용할 경우, 다양한 엑스선 에너지로 인해 같은 물질이라도 두께에 따라 영상에서 정확하게 표현되지 않을 수 있다. 이를 해결하기 위해 엑스선 에너지스펙트럼을 변경하여 영상의 질을 향상 시킬 수 있도록 하였다. SPEKTR v3.0을 사용하여 부가 필터를 추가한 엑스선 에너지스펙트럼과 고유 필터만을 사용한 일반 엑스선 에너지스펙트럼을 획득하였다. 획득한 엑스선 에너지스펙트럼을 Geant4 Application for Tomographic Emission(GATE)의 방사선원으로 사용하여 시뮬레이션을 수행하였다. GATE 데이터를 사용하여 부가 필터가 사용된 엑스선 영상과 부가 필터를 사용하지 않은 엑스선 영상을 재구성한 영상을 74 keV의 단일 에너지 영상을 통해서 비교 분석하였다. 부가 필터를 사용하지 않은 엑스선 에너지스펙트럼을 사용한 경우 같은 물질이라도 두께에 따라 투과한 엑스선의 양이 물질 두께에 따라 감소되는 양과는 상이한 양상을 보인 반면, 부가 필터를 사용한 경우 두께에 따라 투과된 엑스선의 양이 물질 두께에 따라 감소되는 양과 유사한 결과가 나왔다. 즉, 감소되는 선량이 단일 에너지를 사용했을 때와 비슷한 결과가 나왔다. 부가 필터를 사용하여 엑스선 에너지스펙트럼을 변경하여 엑스선 영상을 획득할 경우 엑스선의 투과에 대한 보다 정확한 결과의 값을 획득할 수 있다. 영상의학검사에서 부가 필터의 적절한 사용이 영상의 질을 높이는데 크게 작용한다는 것을 확인하였다.

공간분해능 및 민감도 향상을 위한 새로운 감마카메라 설계 (Gamma Camera Design to Improve Spatial Resolution and Sensitivity)

  • 강승훈;이승재
    • 한국방사선학회논문지
    • /
    • 제17권2호
    • /
    • pp.201-206
    • /
    • 2023
  • 감마카메라의 공간분해능을 향상시키기 위해서는 콜리메이터의 구멍 크기를 작게 만들어야 하므로 민감도는 저하된다. 민감도를 향상시키기 위해서는 구멍 크기를 크게 해야 하므로 공간분해능은 저하된다. 즉, 공간분해능과 민감도는 서로 상반된 특성을 보인다. 본 연구에서는 공간분해능과 민감도를 모두 향상시키는 감마카메라를 설계하였다. 동일한 공간분해능을 보이는 감마카메라에서 보다 높은 민감도를 획득하기 위해 섬광체의 구조를 기존시스템과 다르게 설계하였다. 섬광 픽셀을 사용하고, 섬광 픽셀 사이에는 격벽을 위치시켜 입사한 감마선이 다른 섬광 픽셀로 투과되어 상호작용하는 것을 방지하였다. 설계한 감마카메라의 성능을 평가하기 위해 Geant4 Application for Tomographic Emission (GATE) 시뮬레이션을 수행하였다. 동일한 공간분해능을 획득하는 조건의 콜리메이터를 각각 사용하여 기존 감마카메라와 설계한 감마카메라의 민감도를 획득한 결과 각각 0.0026%, 0.0042%로 설계한 감마카메라의 민감도가 61.54% 향상된 결과를 나타내었다. 본 연구에서 설계한 감마카메라를 사용하면 우수한 공간분해능을 확보하면서 민감도를 기존 시스템보다 향상시킬 수 있을 것으로 판단된다.