• 제목/요약/키워드: Ge channel

검색결과 92건 처리시간 0.023초

Treatment of fever with traditional Chinese medicine according to Zheng on cancer patients (based on case reports)

  • Liu, Lan-Ying;Cao, Peng;Cai, Xue-Ting;Wang, Xiao-Ning;Huo, Jie-Ge;Zhou, Zhong-Ying
    • 셀메드
    • /
    • 제2권2호
    • /
    • pp.16.1-16.5
    • /
    • 2012
  • Fever in cancer patients is often due to the following causes: evil qi and toxity stagnancy, disorders of qi and blood, deficiencies of zang and fu organs, and the disorder of yin and yang. The treatments given to cancer patients with a fever are according to five: (a) Excessive inner heat and toxicants: remove heat and the toxicant, induce purgation. We use Cheng-Qi-Tang plus Qing-Wen-Bai-Du-Yin. (b) Tangle of damp and heat, and qi stagnancy: remove damp and heat, smooth the qi channel. We use Gan-Lu-Xiao-Du-Dan or San-Ren-Tang. (c) Obvious blood and heat stagnancy: remove heat and blood stasis. We use Xue-Fu- Zhu-Yu-Tang. (d) Deficiency of spleen qi, inner heat caused by a yin deficiency: nourish spleen qi and yin to remove the inner heat. We use Bu-Zhong-Yi-Qi-Tang or Xiao-Jian-Zhong-Tang. (e) Prominent yin deficiency and hectic fever: replenish yin and remove inner heat. We use Qing-Hao-Bie-Jia-Tang or Chai- Qian-Mei-Lian-San. The pathogenesis of fever in cancer patients is complicated. We can see both deficiency and excess in one differentiation. Therefore, we must make sure of it, then we can get the most effective treatment.

조영제 사용 전 후 확산강조영상 검사의 비교 분석에 대한 연구 (A Study on Comparative Analysis of Diffusion Weighted Image Examination before and after Contrast Injection)

  • 구은회
    • 대한디지털의료영상학회논문지
    • /
    • 제11권2호
    • /
    • pp.51-57
    • /
    • 2009
  • The purpose of this study would evaluate if having clinical effects on diffusion image with quantitative analysis through ADC values of brain's normal tissue and lesions before and after contrast injections using a 3.0T. From November in 2007 until December in 2008, a total of 32 patient was performed on 3.0T(Signa Excite, GE Medical System, USA) with the normal or lesions in the patient who requests diffusion weighted image with 8channel head coil. The pulse sequence was used with spin echo EPI(TR: 10000msec, TE: 72.2 msec, Matrix: 128*128, FOV: 240 mm, NEX: 1, diffusion direction: 3, b-value: 1000). Measurement results of ADC values on lesions, CSF, white matter, gray matter, lesions after contrast injection were measured less 75% than before contrast injection, infarction: 100%, CSF: 78%(high), white matter: 71.4%(low), gray matter: 50%(high, low). The results of paired t-test on the deference of ADC values which statically is significant in three(lesions, CSF, white matter)regions except for white matter(p<0.05). Quantitative analysis of lesions, CSF, white matter, gray matter have difference on all regions. ADC values were low in lesions and white matter, normal CSF after contrast injection commonly is high than before contrast injection, ADC values which white matter were high and low (50:50) after contrast injection. 3.0T diffusion weighted image clinically supposed that performing DWI examination after contrast injection was not desirable because of having effects on brain tissue.

  • PDF

MD-CT로 얻은 가쪽넙다리휘돌이 관통동맥 3D 영상의 유용성 (Utility of Lateral Circumflex Femoral Artery Perforator's 3D Image with MD-CT)

  • 박수호;심정수;이상곤;박대환
    • Archives of Plastic Surgery
    • /
    • 제35권4호
    • /
    • pp.379-384
    • /
    • 2008
  • Purpose: Currently, using perforator artery flaps especially anterolateral thigh flaps are widely used for reconstruction of extremities, head and neck. Obtaining a precise anatomical picture prior to operation will translate to a more accurate, efficient and safe procedure. Authors used 3D-image work up via 64-slice MDCT to make a more precise preoperative plan. Methods: A total of 10 patients underwent soft tissue reconstruction with anterolateral thigh flap from December 2006 to December 2007. The 64-Channel MDCT (LightSpeed VCT, GE, USA) was used and 3D images were reconstructed. Findings from MDCT were applied to the preoperative planning and confirmed with intraoperative findings. Results: The average number of perforator arteries from lateral circumflex femoral artery was 2. The average lengths of vascular pedicle from the origin of lateral circumflex femoral artery to the first and second perforator artery were 11.0 cm and 20.0 cm, respectively. The average diameter of the pedicle artery was 2.2 mm. The locations of the perforator arteries were mapped and localized on the body surface based on the MDCT result. These were confirmed through direct visualization intraoperatively. Conclusion: MDCT has an advantage of obtaining accurate images of the general anatomy and even fine structures like perforator arteries. By using this state-of-the-art diagnostic imaging technique, it is now possible to make an operative plan safely and easily.

Bandwidth Management of WiMAX Systems and Performance Modeling

  • Li, Yue;He, Jian-Hua;Xing, Weixi
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제2권2호
    • /
    • pp.63-81
    • /
    • 2008
  • WiMAX has been introduced as a competitive alternative for metropolitan broadband wireless access technologies. It is connection oriented and it can provide very high data rates, large service coverage, and flexible quality of services (QoS). Due to the large number of connections and flexible QoS supported by WiMAX, the uplink access in WiMAX networks is very challenging since the medium access control (MAC) protocol must efficiently manage the bandwidth and related channel allocations. In this paper, we propose and investigate a cost-effective WiMAX bandwidth management scheme, named the WiMAX partial sharing scheme (WPSS), in order to provide good QoS while achieving better bandwidth utilization and network throughput. The proposed bandwidth management scheme is compared with a simple but inefficient scheme, named the WiMAX complete sharing scheme (WCPS). A maximum entropy (ME) based analytical model (MEAM) is proposed for the performance evaluation of the two bandwidth management schemes. The reason for using MEAM for the performance evaluation is that MEAM can efficiently model a large-scale system in which the number of stations or connections is generally very high, while the traditional simulation and analytical (e.g., Markov models) approaches cannot perform well due to the high computation complexity. We model the bandwidth management scheme as a queuing network model (QNM) that consists of interacting multiclass queues for different service classes. Closed form expressions for the state and blocking probability distributions are derived for those schemes. Simulation results verify the MEAM numerical results and show that WPSS can significantly improve the network’s performance compared to WCPS.

3D 프린팅 기술을 이용한 전산화단층영상 기반 조직 생검 보조기구 개발 (Development of Biopsy Assist Device on Computed Tomography Using 3D Printing Technology)

  • 김정완;성열훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권2호
    • /
    • pp.151-157
    • /
    • 2023
  • The purpose of this study was to develop an assist device that could correct and support patient position during biopsy on computed tomography (CT) using 3D printing technology. The development method was conducted in the order of 3D design, 3D output, intermediate evaluation for product, final assist device evaluation. The 3D design method was conducted in the order of prior research data survey, measurement, primary modeling, 3D printing, output evaluation, and supplementary modeling. The 3D output was the 3D printer (3DWOX 2X, Sindoh, Korea) with additive manufacturing technology and the polylactic acid (PLA) materials. At this time, the optimal strength was evaluated to infill degree of product as the 3D printing factors into 20%, 40%, 60%, and 80%. The intermediate evaluation and supplementation was measured noise in the region of interest (ROI) around the beam hardening artifact on the CT images. We used 128-channel MDCT (Discovery 75 HD, GE, USA) to scan with a slice thickness of 100 kVp, 150 mA, and 2.5 mm on the 3D printing product. We compared the surrounding noise of the final 3D printing product with the beginning of it. and then the strength of it according to the degree of infill was evaluated. As a result, the surrounding noise of the final and the early devices were measured at an average of 3.3 ± 0.5 HU and 7.1 ± 0.1 HU, respectively, which significantly reduced the noise of the final 3D printing product (p<0.001). We found that the percentage of infill according to the optimal strength was found to be 60%. Finally, development of assist devices for CT biopsy will be able to minimize artifacts and provide convenience to medical staff and patients.

Elliptical Centric과 TRICKS 기법의 임상 적용에 관한 유용성 연구 (Elliptical Centric Techniques and Tricks About the Usefulness of the Clinical Application)

  • 김새싹;구은회;동경래;권대철;이재승;조재환;박창희
    • 대한디지털의료영상학회논문지
    • /
    • 제13권2호
    • /
    • pp.83-90
    • /
    • 2011
  • To prospectively determine the diagnostic performance a combination of standard bolus-chase magnetic resonance (MR) angiography and MR angiography with time-resolved imaging of contrast kinetics (TRICKS) for depicting severity of the head and neck vascular diseases. Over a period of two months, A total of 100 patients(average ages : $50{\pm}8$, male : 60, female : 40) with head and neck vascular diseases were performed on the GE excite 3.0 T units with 8-channel head coil and 4-channel NV coil. Imaging parameters for a typical study were as follow: SBC(TR/ TE/ FA/ SliceThicken./ Slab/ Freq./ FOV/ BW/Scan Time) = 5.4/ min/ 30/ 2/ zip2/ 70/ $224{\times}448$/ 30/ 62.50/ 28, TRICKS(TR/ TE/ FA/ Slice Thicken/Slab/ Freq./ FOV/ BW/ Temp Res./ Scan Time = 3.6/ min/ 25/ 4/ 30/ $160{\pm}384$, zip512/ 30/ 100/ 1 to 1.5/ 23). The analysis of all MR images, which have respect-ively classified two techniques into some diseases. The results of the former were divided into two groups(SBC, TRICKS)with 4 grading of two reader, respectively. Wilcoxon signed rank test was used to determine if a significant difference between imaging techniques existed(p < 0.05). In 33 of 100 patients, arterio-venous malformation was 11% at TRICKS, subclavian vein stenosis : 8%, fistular sinus : 4%, jugular vein stenosis:6%, Middle Cerebral Artery bypass surgery : 4%, p < 0.05). The rest of 67 patients were considered as the results of SBC(14% in the basilar artery stenosis, carotid stenosis : 16%, vertebral stenosis : 17%, central neuro-cytoma : 5%, meningioma : 5%, Not appliable : 10%, p < 0.05). Sensitivity and specificity of TRICKS MR angiography in SVS, FS, JVS, MCABS were improved compared with those at standard MR angiography. In SBS MR angiography which were improved in BAS, CS, VS, CN, Meningioma. In conclusion, TRICKS MR angiography of the SVS, FS, JVS, MCABS is superior to standard MR angiography regarding the number of diagnostic grading. The SBS MR angiography were improved in BAS, CS, VS, CN, Meningioma. and assessment of the degree of luminal narrowing on both TRICKS and SBS.

  • PDF

MSU와 ECMWF에서 유도된 중간 및 하부 대류권 온도의 시 ${\cdot}$ 공간 변동 (Temporal and Spatial Variability of the Middle and Lower Tropospheric Temperatures from MSU and ECMWF)

  • 유정문;이은주
    • 한국지구과학회지
    • /
    • 제21권5호
    • /
    • pp.503-524
    • /
    • 2000
  • 중간 및 하부 대류권의 열적 상태에 대한 관측 및 모델 결과들의 상태적인 정확성을 평가하기 위하여 세 종류의 위성관측 MSU 채널2 밝기온도 자료들과 ECMWF 모델의 재분석 (1980-93년) 자료를 상호 비교하였다. 중간 대류권 온도를 반영하는 위성관측 자료는 직하점에서의 MSU2 (1980-98년)와 여러 주사각으로부터 유도된 SC2 (1980-97년)이고, 하부 대류권 온도를 반영하는 자료는 SC2R (1980-97년)이다. 여기서 MSU2는 본 연구에서, 그리고 SC2와 SC2R은 Spencer and Christy (1992a, 1992b)에서 유도되었다. 위의 네 종류 자료간의 상관은 중 ${\cdot}$ 고위도에서 높았으나 (r${\ge}$0.90), 저위도 그리고 대류가 활발한 열대 지역에서 낮았다 Hydrometeors (구름과 강수) 및 지표방출의 영향으로 잡음을 포함하는 SC2R에 대한 다른 자료의 상관이 특히 낮았다 (r${\sim}$0.65). 또한 모델 재분석에 대한 위성자료의 상관은 MSU2보다 강수 효과가 일부 제거된 SC2에서 높았다. 세 종류의 MSU 기후값의 아노말리 비교에서 지표에 민감한 SC2R의 북반구 온도는 MSU2나 SC2에 비해 현저하게 1월에 하강하였고 7월에 상승하였다. 관측 및 모델 온도들에 대한 경험직교함수 분석에서 월평균값 모드1은 열대 태평양을 제외하고 연주기를 보였다. 전체 태평양에 대한 MSU2 모드1은 Walker 순환에 의한 동 ${\cdot}$ 서 쌍극자 형태를 보인 반면, 다른 위성관측과 모델 자료에서는 이러한 형태가 약하였다. 관측과 모델은 열대 태평양에 대한 아노말리값의 모드1, 2에서 엘니뇨와 라니냐에 의한 경년변동을 뚜렷하게 보였다. 적도 서태평양 용승 지역에서의 관측과 모델 결과 사이의 불일치는 모델에서 대기-해양 상호작용이 보완되어야 함을 제시한다.성관측 자료가 기후변동에서의 피이드백 작용을 이해하는데에 유용하게 사용될수 있음을 본 연구는 제시한다.EX>$^{\circ}$C, 0.16${\sim}$0.62의 X$_{CO}\;_{2}$, 5${\sim}$14mole% CH$_{4}$, 0.06${\sim}$0.31mole% N$_{2}$, 0.4${\sim}$4.9wt.% NaCl의 염농도. 설화 금광산의 온도-조성 자료는 설화 함금열수계가 화강암질 용융체와 인접한 부분에 정치되어 있었음을 지시한다. 이러한 화강암질 용융체는 CH$_{4}$ 형성을 촉진시켜 유체를 환원상태로 변환시킨 것으로 추정된다. 철황화물중 자류철석이 지배적으로 산출됨은 환원유체 상태를 지시하고 있다. 황화광물의 ${\delta}\;^{34}$S값(-0.6 ${\sim}$ 1.4$%_o$)은 황의 심부 화성기원을 지시하고 있다.위해서는 각 행정부서별로 사용하는 행정자료들을 연계${cdot}$통합할 수 있도록 국가사회전반에 걸쳐 행정 체제가 갖추어져야 하기 때문이다. 특히 모든 국민 개개인에 관한 기본정보, 개인들이 거주하며 생활하는 단위인 개별 주거단위에 관한 정보가 행정부에 등록되어 있고, 잘 정비되어 있어야 하며, 정보의 형태 또한 서로 연계가 가능하도록 표준화되어있어야 한다. 이와 더불어, 현재 인구센서스에서 표본조사를 통해 부가적으로 생산하는 경제활동통계를 생산하기 위해서는 개인이 속한 사업체를 파악할 수 있도록 모든 사업체가 등록되어 있고, 개인의 경제활동과 관련된 각종 정보들이 사업체에 잘 기록 및 정비되어 있어야 한다. 따라서 행정자료 기반의 인구센서스통계생산은 단지 국가의 통계뿐만 아니라 행정조직과 행정체계를 정비하고, 개인과 사업체의

  • PDF

하부 성층권 온도에 대한 위성자료와 모델 재분석들과의 비교 (Intercomparison of Satellite Data with Model Reanalyses on Lower- Stratospheric Temperature)

  • 유정문;김진남
    • 한국지구과학회지
    • /
    • 제21권2호
    • /
    • pp.137-158
    • /
    • 2000
  • 측과 모델에서 각각 유도된 하부 성층권의 온도를 비교 ${\cdot}$ 분석하기 위하여 전구에 대한 1980-98년 기간의 위성관측 MSU 채널4 (하부 성층권) 밝기온도와 두 개의 대기대순환 모델(NCEP, 1980-97년; GEOS, 1981-94년) 재분석 자료를 상관 및 경험직교함수 분석을 통하여 조사하였다. 월평균 기후값의 아노말리에서 MSU 온도는 남반구 겨울에 고위도 지역에서 현저하게 감소하였으나 (20-22K), 남반구 봄인 10월에는 오스트레일리아의 이남 지역에서 하부 성층권 온도 및 오존 전량이 주목 할만하게 동시에 상승하였다. 열대지방에서는 온도 연주기가 중 ${\cdot}$ 고위도에 비하여 뚜렷하지 않았다. 전구 대부분의 지역에서관측과 모델 사이에 상관은 높았으나 (r${\ge}$0.95), 아열대 제트기류가 통과하는 20N-3ON 지역, 북미 대륙 그리고 안데스산맥 남단지역에서 낮았다(r${\sim}$O.75). MSU 및 모델 재분석들의 월평균값에 대한 모드 1은 연주기와 함께 화산 폭발시에 하부 성층권의 온도 상승을 나타냈다. 한반도 지역에 대한 분석은 하부 성층권 온도가 대류권과 대조적으로 여름에 하강하고 겨울에 상승하는 형태를 보였다. 열대 태평양에 대한 MSY 및 재분석들의 아노말리 모드 1은 화산폭발에 의한 하부 성층권 온도 상승을 나타냈다. 모드 2는 MSH와 GEOS에서 준2년 주기진동 (QBO), 그러나 NCEP에서 엘니뇨 특징을 보였다. 엘니뇨 특징은 MSU와 GEOS의 경우에 모드 3에서 나타났다. 관측과 모델 모두에서 하부 성층권 온도에 대한 기여율이 대체로 화산폭발, QBO, 엘니뇨 순으로 높았다. 열대 대서양의 결과도 무시할 만한 엘니뇨 기여를 제외하고 열대 태평양과 비슷하였다 본 연구는 하부 성층권 온도에 대한 위성관측과 모델 재분석 자료와의 비교를 통하여 상호 정확성을 진단할 수 있음을 보여준다.

  • PDF

인공결석모형물의 부피와 하운스필드값 측정에 대한 전산화단층촬영기기의 타입과 빔 콜리메이션의 영향 (Effect of Different CT Scanner Types and Beam Collimations on Measurements of Three-Dimensional Volume and Hounsfield Units of Artificial Calculus Phantom)

  • 왕지환;이희천
    • 한국임상수의학회지
    • /
    • 제31권6호
    • /
    • pp.495-501
    • /
    • 2014
  • 본 연구는 다양한 전산화단층촬영기기와 촬영 프로토콜의 차이에 따른 모형물의 부피와 Hounsfield unit (HU) 수치의 차이를 평가하고 이 후 전산화단층촬영술을 이용하여 결석의 부피와 HU 수치를 포함한 다양한 인자들을 평가하고 이 중 체외충격파쇄석술에 의한 결석의 분쇄를 예측할 수 있는 인자를 찾고자 하였다. 다양한 직경의 100 HU 인공종양 5개를 (직경 3.0-12.0 mm) 이용하여 모형물을 만들었으며, 이 모형물의 부피와 HU 수치를 Siemens사의 2채널, GE사의 4채널과 64채널, 그리고 Philips사의 64채널 전산화단층촬영기기를 사용하여 평가하였다. 또한 각각의 전산화단층촬영기기에서 동일한 조건으로 collimation만 thin collimation과 thick collimation으로 변화를 주어 모형물을 촬영한 후 모형물의 부피와 HU 수치를 평가하였다. 평가자간 (inter-observer) 재현성을 평가하기 위해 3명의 수의영상의학 전공의가 연구에 참여하였으며 이중 한 명의 수의사가 평가자내 (intra-observer) 재현성을 평가하기 위해 모형물의 부피와 HU 수치를 2주 간격으로 총 3번 측정하였다. 부피의 평가자간 재현성과 평가자내 재현성은 k=0.9994, k=0.9969로 아주 우수하였으며, HU 수치의 평가자간 재현성과 평가자내 재현성 역시 k=0.9984, k=0.9655로 아주 우수하였다. 다양한 전산화단층촬영기기와 collimation 차이에 따른 부피와 HU 수치의 차이는 모두 통계학적으로 유의적인 차이를 나타내지 않았다. 그러나 부피의 경우 collimation이 얇을수록 부피의 정확도가 증가하는 경향을 보였다. 본 연구 결과를 토대로 향후 진행될 결석의 부피 및 HU 수치의 평가 시 전산화단층촬영기기의 차이에 따른 영향을 받지 않으리라 판단되어 Siemens사의 2채널 전산화단층촬영기기만을 사용하였으며, 비록 통계학적으로 유의적인 차이는 없었지만 부피의 정확도를 더 높이기 위하여 얇은 collimation을 사용하였다.

Comparison of Parallel and Fan-Beam Monochromatic X-Ray CT Using Synchrotron Radiation

  • Toyofuku, Fukai;Tokumori, Kenji;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.407-410
    • /
    • 2002
  • Monochromatic x-ray CT has several advantages over conventional CT, which utilizes bremsstrahlung white x-rays from an x-ray tube. There are several methods to produce such monochromatic x-rays. The most popular one is crystal diffraction monochromatization, which has been commonly used because of the fact that the energy spread is very narrow and the energy can be changed continuously. The alternative method is the use of fluorescent x-ray, which has several advantages such as large beam size and fast energy change. We have developed a parallel-beam and a fan-beam monochromatic x-ray CT, and compared some characteristics such as accuracy of CT numbers between those systems. The fan beam monochromatic x-rays were generated by irradiating target materials by incident white x-rays from a bending magnet beam line NE5 in 6.5 GeV Accumulation Ring at Tukuba. The parallel beam monochromatic x-rays were generated by using a silicon double crystal monochromator at the bending magnet beam line BL-20BM in Spring-8. A Cadmium telluride (CdTe) 256 channel array detector with 512mm sensitive width capable of operating at room temperature was used in the photon counting mode. A cylindrical phantom containing eight concentrations of gadolinium was used for the fan beam monochromatic x-ray CT system, while a phantom containing acetone, ethanol, acrylic and water was used for the parallel monochromatic x-ray CT system. The linear attenuation coefficients obtained from CT numbers of those monochromatic x-ray CT images were compared with theoretical values. They showed a good agreement within 3%. It was found that the quantitative measurement can be possible by using the fan beam monochromatic x-ray CT system as well as a parallel beam monochromatic X-ray CT system.

  • PDF