• Title/Summary/Keyword: Ge channel

Search Result 92, Processing Time 0.028 seconds

Development of T700/701K engine for KUH (한국형 기동 헬기 엔진 (T700/701K) 개발)

  • Kim, Jae-Hwan;Ahn, Iee-Ki;Lee, Dae-Sung;Sung, Ok-Suck;Sung, In-Kyung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.506-511
    • /
    • 2010
  • This paper presents development activities of the T700/701K turbo-shaft engine for Korean Utility Helicopter(KUH). The T700/701K is the first rear-drive variant of the GE's T700 engine which is proven for military applications in the world. The main workscope of the development includes a modification from a front-drive engine to a rear-drive one, an performance enhancement of the power turbine and an incorporation of two channel FADEC(Full Authority Digital Engine Control) system for more reliable operation. The first engine run for development and qualification test was successfully completed in 2008. Since the PFRT(Preliminary Flight Rating Test) has been completed, the first flight of the engine installed in the first prototype of KUH has been successfully demonstrated in March, 2010 and the engine installation compatibility tests are being carried out during KUH flight test. The test and evaluation for qualification of the engine has been done except for the LCF test up to date.

  • PDF

Helicobacter pylori Vacuolating Toxin Exhibits Polar Activity of $Cl^-$ Secretion and Secretory Response to Carbachol in T84 Cells

  • Jin, Nan-Ge;Jin, Yong-Ri;So, In-Suk;Kim, Ki-Whan
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.8 no.5
    • /
    • pp.289-293
    • /
    • 2004
  • To investigate whether VacA (vacuolating toxin) produced by Helicobacter pylori Korean stain 99 induces intestinal secretion, purified VacA was added to T84 cell monolayers mounted in Ussing chambers, and electrical parameters were monitored. Mucosal addition of low pH-pretreated VacA increased short circuit current (Isc). The effect was time- and dose-dependent and saturable. The time-to-peak Isc was concentration-dependent. Chloride channel inhibitors, niflumic acid or 5-nitro-2-(3-phenylpropylamino)-benzoate (NPPB), inhibited VacA-stimulated Isc. Carbachol (CCh)-induced increase of Isc was prolonged by the addition of VacA to the mucosal side only. The effect was unaltered by the addition of niflumic acid. VacA did not show cytopathic effects. These studies indicate that VacA is a nonlethal toxin that acts in a polar manner on T84 monolayers to potentiate $Cl^-$ secretion and the response to CCh secretion without decrease in monolayer resistance. VacA may contribute to diarrhea diseases in human intestinal epithelial cells.

III-V 화합물 반도체 Interface Passivation Layer의 원자층 식각에 관한 연구

  • Gang, Seung-Hyeon;Min, Gyeong-Seok;Kim, Jong-Gyu;Yeom, Geun-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.198-198
    • /
    • 2013
  • Metal-Oxide-Semiconductor (MOS)에서 사용되는 다양한 channel materials로 high electron mobility을 가지는 III-V compound semiconductor가 대두되고 있다 [1,2]. 하지만 이러한 III-V compound semiconductor는 Si에 비해 안정적인 native oxide가 부족하기 때문에 Si, Ge, Al2O3과 BeO 등과 같은 다양한 물질들의 interface passivation layers (IPLs)에 대한 연구가 많이 되고 있다. 이러한 IPLs 물질은 0.5~1.0 nm의 매우 얇은 physical thickness를 가지고 있고 또한 chemical inert하기 때문에 플라즈마 식각에 대한 연구가 되고 있지만 IPLs 식각 후 기판인 III-V compound semiconductor에 physical damage과 substrate recess를 줄이기 위해서 높은 선택비가 필요하다. 이러한 식각의 대안으로 원자층 식각이 연구되고 있으며 이러한 원자층 식각은 반응성 있는 BCl3의 adsorption과 low energy의 Ar bombardment로 desorption으로 self-limited한 one monolayer 식각을 가능하게 한다. 그러므로 본 연구에서는, III-V compound semiconductor 위에 IPLs의 adsorption과 desorption의 cyclic process를 이용한 원자층식각으로 다양한 물질인 SiO2, Al2O3 (self-limited one monolayer etch rate=about 1 ${\AA}$/cycle), BeO (self-limited one monolayer etch rate=about 0.75 ${\AA}$/cycle)를 얻었으며 그 결과 precise한 etch depth control로 minimal substrate recess 식각을 할 수 있었다.

  • PDF

Performance of Capacitorless 1T-DRAM Using Strained-Si Channel Effect

  • Jeong, Seung-Min;O, Jun-Seok;Kim, Min-Su;Jeong, Hong-Bae;Lee, Yeong-Hui;Jo, Won-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.130-130
    • /
    • 2011
  • 최근 반도체 메모리 산업의 발전과 동시에 발생되는 문제들을 극복하기 위한 새로운 기술들이 요구되고 있다. DRAM (dynamic random access memory) 의 경우, 소자의 크기가 수십 나노미터 영역으로 줄어들면서, 단채널 효과에 의한 누설전류와 소비전력의 증가 등이 문제가 되고 있다. 하나의 캐패시터와 하나의 트랜지스터로 구성된 기존의 DRAM은, 소자의 집적화가 진행 되어 가면서 정보저장 능력이 감소하는 것을 개선하기 위해, 복잡한 구조의 캐패시터 영역을 요구한다. 이에 반해 하나의 트랜지스터로 구성되어 있는 1T-DRAM의 경우, 캐패시터 영역이 없는 구조적인 이점과, SOI (silicon-on-insulator) 구조의 기판을 사용함으로써 뛰어난 전기적 절연 특성과 기생 정전용량의 감소, 그리고 기존 CMOS (complementary metal oxide semiconductor) 공정과의 호환성이 장점이다. 또한 새로운 물질 혹은 구조를 적용하여, 개선된 전기적 특성을 통해 1T-DRAM의 메모리 특성을 향상 시킬 수 있다. 본 연구에서는, SOI와 SGOI (silicon-germanium-on-insulator) 및 sSOI (strained-si-on-insulator) 기판을 사용한 MOSFET을 통해, strain 효과에 의한 전기적 특성 및 메모리 특성을 평가 하였다. 그 결과 strained-Si층과 relaxed-SiGe층간의 tensile strain에 의한 캐리어 이동도의 증가를 통해, 개선된 전기적 특성 및 메모리 특성을 확인하였다. 또한 채널층의 결함이 적은 sSOI 기판을 사용한 1T-DRAM에서 가장 뛰어난 특성을 보였다.

  • PDF

Technical Trend of Fusion Semiconductor Devices Composed of Silicon and Compound Materials (실리콘-화합물 융합 반도체 소자 기술동향)

  • Lee, S.H.;Chang, S.J.;Lim, J.W.;Baek, Y.S.
    • Electronics and Telecommunications Trends
    • /
    • v.32 no.6
    • /
    • pp.8-16
    • /
    • 2017
  • In this paper, we review studies attempting to triumph over the limitation of Si-based semiconductor technologies through a heterogeneous integration of high mobility compound semiconductors on a Si substrate, and the co-integration of electronic and/or optical devices. Many studies have been conducted on the heterogeneous integration of various materials to overcome the Si semiconductor performance and obtain multi-purpose functional devices. On the other hand, many research groups have invented device fusion technologies of electrical and optical devices on a Si substrate. They have co-integrated Si-based CMOS and InGaAs-based optical devices, and Ge-based electrical and optical devices. In addition, chip and wafer bonding techniques through TSV and TOV have been introduced for the co-integration of electrical and optical devices. Such intensive studies will continue to overcome the device-scaling limitation and short-channel effects of a MOS transistor that Si devices have faced using a heterogeneous integration of Si and a high mobility compound semiconductor on the same chip and/or wafer.

A Low Power and High Linearity Up Down Converter for Wireless Repeater (무선 중계기용 저전력, 고선형 Up-down Converter)

  • Hong, Nam Pyo;Kim, Kwang Jin;Jang, Jong-Eun;Chio, Young-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.433-437
    • /
    • 2015
  • We have designed and fabricated a low power and high linearity up down convertor for wireless repeaters using $0.35{\mu}m$ SiGe Bipolar CMOS technology. Repeater is composed of a wideband up/down converting mixer, programmable gain amplifiers (PGA), input buffer, LO buffer, filter driver amplifier and integer-N phase locked loop (PLL). As of the measurement results, OIP3 of the down conversion mixer and up conversion mixer are 32 dBm and 17.8 dBm, respectively. The total dynamic gain range is 31 dB with 1 dB gain step resolution. The adjacent channel leakage ratio (ACLR) is 59.9 dBc. The total power consumption is 240 mA at 3.3 V.

Effects of Zinc on Spontaneous Miniature GABA Release in Rat Hippocampal CA3 Pyramidal Neurons

  • Choi, Byung-Ju;Jang, Il-Sung
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.10 no.2
    • /
    • pp.59-64
    • /
    • 2006
  • The effects of $Zn^{2+}$ on spontaneous glutamate and GABA release were tested in mechanically dissociated rat CA3 pyramidal neurons which retained functional presynaptic nerve terminals. The spontaneous miniature excitatory and inhibitory postsynaptic currents (mEPSCs and mIPSCs, respectively) were pharmacologically isolated and recorded using whole-cell patch clamp technique under voltage-clamp conditions. $Zn^{2+}$ at a lower concentration $(30{\mu}M)$ increased GABAergic mIPSC frequency without affecting mIPSC amplitude, but it decreased both mIPSC frequency and amplitude at higher concentrations $({\ge}300{\mu}M)$. In contrast, $Zn^{2+}$ (3 to $100{\mu}M$) did not affect glutamatergic mEPSCs, although it slightly decreased both mIPSC frequency and amplitude at $300{\mu}M$ concentration. Facilitatory effect of $Zn^{2+}$ on GABAergic mIPSC frequency was occluded either in $Ca^{2+}$-free external solution or in the presence of $100{\mu}M$ 4-aminopyridine, a non-selective $K^{+}$ channel blocker. The results suggest that $Zn^{2+}$ at lower concentrations depolarizes GABAergic nerve terminals by blocking $K^{+}$ channels and increases the probability of spontaneous GABA release. This $Zn^{2+}$-mediated modulation of spontaneous GABAergic transmission is likely to play an important role in the regulation of neuronal excitability within the hippocampal CA3 area.

Quantitative Assay of Hepatitis B Surface Antigen by Using Surface Plasmon Resonance Biosensor

  • Hwang, Sang-Yoon;Yoo, Chang-Hoon;Jeon, Jun-Yeoung;Choi, Sung-Chul;Lee, Eun-Kyu
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.10 no.4
    • /
    • pp.309-314
    • /
    • 2005
  • We performed a basic experiment for the rapid, on-line, real-time measurement of hepatitis B surface antigen using a surface plasmon resonance biosensor. We immobilized anti­HBsAg (hepatitis B surface antigen) polyclonal antibody, as a ligand, to the dextran layer on a CM5 chip surface that had previously been activated by N-hydroxysuccinimide. A sample solution containing HBsAg was fed through a microfluidic channel, and the reflecting angle change due to the mass increase from the binding was detected. The binding characteristics between HBsAg and its polyclonal antibody followed the typical monolayer adsorption isotherm. When the entire immobilized antibody had interacted, no additional, non-specific binding occurred, suggesting the immunoreaction was very specific. The bound antigen per unit mass of the antibody was independent of the immobilized ligand density. No significant steric hindrance was observed at an immobilization density of approximately $17.6 ng/mm^2$. The relationship between the HBsAg concentration in the sample solution and the antigen bound to the ligand was linear up to ca. $40{\mu}g$/mL. This linearity was much higher than that of the ELISA method. It appeared the anti­gen-antibody binding increased as the immobilized ligand density increased. In summary, this study showed the potential of this SPR biosensor-based method as a rapid, simple and multi­sample on-line assay. Once properly validated, it may serve as a more efficient method for HBsAg quantification for replacing the ELISA.

Development of MR Compatible Coaxial-slot Antenna for Microwave Hyperthermia (초고주파 가열치료를 위한 MR 호환 동축 슬롯 안테나의 개발)

  • Kim, T.H.;Chun, S.I.;Han, Y.H.;Kim, D.H.;Mun, C.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.4
    • /
    • pp.333-340
    • /
    • 2009
  • MR compatible coaxial-slot antenna for microwave hyperthermia was developed while its structure and size of each part were determined by computer simulation using finite element method(FEM). Its local heating performance was evaluated using tissue-mimic phantom and swine muscles. 2% agarose gel mixed with 6mM/$\ell$ $MnCl_2$ as a biological tissue-mimic phantom was heated by the proposed antenna driven by a 2.45GHz microwave generator. The temperature changes of the phantom were monitored using multi-channel digital thermometer at the distance of 0mm, 5mm, 10mm and 20mm from the tip center of the antenna. Also muscle tissue of swine was heated for 2 and 5minutes with 50W and 30W of microwave generator powers, respectively, to evaluate the local heating performance of the antenna. MRI compatibility was also verified by acquiring MR images and MR temperature map. MR signals were acquired from the agarose gel phantom using $T2^*$ GRE sequence with 1.5T clinical MRI scanner(Signa Echospeed, GE, Milwaukee, WI, U.S.A.) at Pusan Paik Hospital and were transferred to PC in order to reconstruct MR images and temperature map using proton resonance frequency(PRF) method and laboratory-developed phase unwrapping algorithm. Authors found that it has no severe distortion due to the antenna inserted into the phantom. Finally, we can conclude that the suggested coaxial-slot antenna has an excellent local heating performance for both of tissue-mimic phantom and swine muscle, and it is compatible to 1.5T MRI scanner.

A Monochromatic X-Ray CT Using a CdTe Array Detector with Variable Spatial Resolution

  • Tokumori, Kenji;Toyofuku, Fukai;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.411-414
    • /
    • 2002
  • The CdTe semiconductor detector has a higher detection efficiency for x-rays and $\square$amma rays and a wider energy band gap compared with Si and Ge semiconductor detectors. Therefore, the size of the detector element can be made small, and can be operated at room temperature. The interaction between a CdTe detector and incident x-rays is mainly photoelectric absorption in the photon energy range of up to 100 keV. In this energy range, Compton effects are almost negligible. We have developed a 256 channel CdTe array detector system for monochromatic x-ray CT using synchrotron radiation. The CdTe array detector system, the element size of which is 1.98 mm (h) x 1.98 mm (w) x 0.5 mm (t), was operated in photon counting mode. In order to improve the spatial resolution, we tilted the CdTe array detector against the incident parallel monochromatic x-ray beam. The experiments were performed at the BL20B2 experimental hutch in SPring-8. The energy of incident monochromatic x-rays was set at 55 keV. Phantom measurements were performed at the detector angle of 0, 30 and 45 degrees against the incident parallel monochromatic x-rays. The linear attenuation coefficients were calculated from the reconstructed CT images. By increasing the detector angle, the spatial resolutions were improved. There was no significant difference between the linear attenuation coefficients which were corrected by the detector angle. It was found that this method was useful for improving the spatial resolution in a parallel monochromatic x-ray CT system.

  • PDF