• Title/Summary/Keyword: Gaussian response curve

Search Result 5, Processing Time 0.021 seconds

Equivalence study of canonical correspondence analysis by weighted principal component analysis and canonical correspondence analysis by Gaussian response model (가중주성분분석을 활용한 정준대응분석과 가우시안 반응 모형에 의한 정준대응분석의 동일성 연구)

  • Jeong, Hyeong Chul
    • The Korean Journal of Applied Statistics
    • /
    • v.34 no.6
    • /
    • pp.945-956
    • /
    • 2021
  • In this study, we considered the algorithm of Legendre and Legendre (2012), which derives canonical correspondence analysis from weighted principal component analysis. And, it was proved that the canonical correspondence analysis based on the weighted principal component analysis is exactly the same as Ter Braak's (1986) canonical correspondence analysis based on the Gaussian response model. Ter Braak (1986)'s canonical correspondence analysis derived from a Gaussian response curve that can explain the abundance of species in ecology well uses the basic assumption of the species packing model and then conducts generalized linear model and canonical correlation analysis. It is derived by way of binding. However, the algorithm of Legendre and Legendre (2012) is calculated in a method quite similar to Benzecri's correspondence analysis without such assumptions. Therefore, if canonical correspondence analysis based on weighted principal component analysis is used, it is possible to have some flexibility in using the results. In conclusion, this study shows that the two methods starting from different models have the same site scores, species scores, and species-environment correlations.

Experimental response function of a photoelectron spectrometer

  • Moonsup Han;Shin, Hye-Yeong;S.J. Oh
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.3 no.2
    • /
    • pp.107-111
    • /
    • 1999
  • We developed the experimental function (ERF) which can be used for the numerical curve fitting analysis in photoelectron spectroscopy (PES). We selected the core-levels of Ag 3d5/2 and Au 4f7/2 to obtain the ERF from the measured core-level spectra. For the numerical fourier transformation we applied the fast transform (FFT) algorithm. we considered optical (Wiener) filtering with the FFT due to noise and used Hann window function to remedy the information leakage in frequency domain due to discrete and finite sampling of measurement. The comparison of the curve fitting results using the ERF obtained in this work and the mathematical response function with a gaussian in the conventional approach shows clearly the improvement of the curve fitting analysis.

  • PDF

Dynamic Characteristics Estimation of the Oculomotor control System using Band-Limited Pseudo Random Signals (의사 랜덤 신호에 의한 동안계의 동특성 추정)

  • 김성환;박상예
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.18 no.4
    • /
    • pp.12-20
    • /
    • 1981
  • In this paper, Band-limlted Gaussian Random Noise and PRBS(pseudo random hinary sequence) are used as a test signals to estimate the dynamic characteristics of the ocuiomotor system. Eye movements of the human subject are measured by E.O.G(electro-oculography) and the control characteristics of the oculomotor system are studied by random signal an-alysis based on the statistical communication theory. The conclusions are summerized as follows. (1) From the frequency response, the gain curve rises slightly at the regions of 0.7~0.9 Hz and 1.8~2 Hz due to the saccades which are occurred during usual tracking. (2) The average rate of information transfer by the oculomotor control system is 1.24 bits/sec, being calculated from the power spectral density and the cross spectral density for the Gaussian random input.

  • PDF

Active Noise Transmission Control Through a Panel Structure Using a Frequency Domain Identification Method (주파수 영역 모델 방법을 이용한 평판 구조물의 능동 소음전달 제어)

  • Kim, Yeung-Shik;Kim, In-Soo;Moon, Chan-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.9
    • /
    • pp.71-81
    • /
    • 2001
  • This paper analyzes the effectiveness of minimizing vibration and sound transmission on/through a thin rectangular plate by both feedback control and hybrid control which combines adaptive feedforward control with a feedback loop. An experimental system identification technique using the matrix-fractional curve-fitting of the frequency response data is introduced for complex shaped structures. This identification technique reduces the model order o the MIMO(Multi-Input Multi-Output) system which simplifies the practical implementation. The adaptive feedforward control uses a Multiple filtered-x LMS(Least Mean Square) algorithm and the feedback control uses a multivariable digital LQG(Linear Quadratic Gaussian) algorithm. Experimental results show that an effective reduction of sound transmission is achieved by the hybrid control scheme when both vibration and noise measurement signals are incorporated in the controller.

  • PDF

Electro-Optical Characteristics of CdS : In Films Grown by Hot-Wall Evaporation and Its Application (HWE에 의하여 성장된 CdS : In 박막의 전기광학적 특성과 그 응용)

  • 최용대;윤희중;김진배;이완호;신영진;양동익
    • Journal of the Korean Vacuum Society
    • /
    • v.1 no.3
    • /
    • pp.360-370
    • /
    • 1992
  • HWE(Hot-Wall Epitaxy) 방법에 의하여 pyrex 유리기판 위에 CdS 다결정 박막을 성장하였다. X-선 회절실험 결과 CdS 박막은 육방정이었는데 (0002)면보다 91013)면이 강 하게 성장됨을 알 수 있었다. 전자현미경으로 표면을 분석한 결과 입자의 크기는 기판의 온 도가 48$0^{\circ}C$, 증발원의 온도가 $610^{\circ}C$일 때 1~1.5$mu extrm{m}$로서 가장 컸다. 박막의 표면저항은 4-point probe로서 측정한 결과 10-8$\Omega$/\ulcorner이상이었다. 성장된 CdS 다결정 박막의 photoluminesence을 20K에서 측정하였는데 bound exciton, donor acceptor pair에 의한 발광이 관측되었다. Spectral response의 peak는 505nm이었다. CdS 다결정 박막의 표면 저항을 줄이기 위하여 여러 가지 온도에서 Indium을 확산시켰다. 그 결과 표면저항은 ~ $\times$ 101에서 ~ $\times$ 103$\Omega$/\ulcorner 정도 감소되었다. 50$0^{\circ}C$에 In을 1시간 확산시켰을 때 표면저항은 1300$\Omega$/\ulcorner이었다. 이 때 CdS : In의 운반자 농도는 1.2 $\times$ 1018cm-3, 이동도는 1.8cm-2/V-sec, 비저항은 1.3 $\times$ 10-2$\Omega$-cm이었다. CdS : In의 photoluminescence는 20K 에서 Gaussian curve를 보여 주었으며 peak의 위치는 510nm이었다. CdS : In 박막의 spectral response의 peak는 상온에서 500nm이다. CdS : In 광전도 cell의 sensitivity ${\gamma}$ =0.77이고, 최대 허용소비전력은 p=120mW, 100lux에서 rise time은 8 msec, decay time 은 6 msec이다.

  • PDF