• Title/Summary/Keyword: Gate opening

Search Result 112, Processing Time 0.022 seconds

Model Tests Study on Flow-induced Vibration of Truss Type Lift Gate (트러스형 리프트 게이트의 진동현상에 관한 모형실험)

  • Lee, Seong-Haeng;Kim, Ha-Jip;Park, Young-Jin;Hahm, Hyung-Gil;Kong, Bo-Sung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.3
    • /
    • pp.35-41
    • /
    • 2011
  • A model test is carried out to investigate the vibration of truss type lift gate in the four major rivers project. The gate model scaled with the ratio of 1 : 25 is made of acryl panel dimensioned 1.6 m in width, 0.28 m in height in the concrete test flume. Firstly natural frequencies of the model gate are measured and the results are compared with the numerical results in order to verify the model. The amplitudes of the vibration are measured under the different gate opening and water level conditions. The results are analyzed to study the characteristics of the gate vibration according to the small gate opening, the large gate opening and the overflow conditions. These test results presents a basic data for the guide manuals of gate management and a design method to reduce the gate vibration of truss type lift gate. Finally, the vibration of truss type lift gate are assessed in comparison with those of formerly tainter gate.

A Method on Estimation of Avoiding Open Range on Shell-type Roller Gate (쉘타입 로울러 게이트의 회피개도량 산정 방법)

  • Chung, Jee-Seung;Jung, Hae-Wook
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.85-91
    • /
    • 2017
  • When the shell-type roller gate is partly open, at a certain height the large vibration is caused due to resonance and the vibration can cause damage to the gate. In this study, the review on amplitude of vibration and the possible resonance occurring at the time of opening or closing of gate is performed. Throughout the natural frequency analysis, the installation location of the measuring instrument was selected. On opening or closing of gate, the measurement of gate vibration is performed. The natural frequencies according to the opening range of the gate is analyzed. As a result of measurement and analysis, we proposed ranges in which vibration occurs largely and resonance is predicted as an avoiding open ranges, or the safe opening or closing of the shell-type roller gate. The application of this paper's avoiding open range estimation method of shell-type roller gate can be utilized as the basic data for the systematic and rational maintenance management of dams and submerged weirs in the future, and it is expected that this study can bring forth.

A Numerical Simulations on the Flow over Ogee Spillway with Tainter Gate (테인터수문이 설치된 월류형 여수로에서의 흐름에 대한 수치모의)

  • Kim, Dae-Geun;Park, Jae-Hyun;Lee, Jae-Hyung
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.8
    • /
    • pp.675-685
    • /
    • 2004
  • In this study, overflow behaviors through a partially open tainter gate mounted on a standard ogee spillway were investigated by using the FLOW-3D. The results indicated that the discharge coefficient is in the range of 0.685 to 0.723. A relation of gate-controlled discharge to free discharge was proposed and a reasonable correlation between the free and controlled discharge was obtained. Pressures on the spillway crest and the gate were also investigated. As the gate opening rate decreases with a fixed gate opening height and the gate opening height increases at a fixed gate opening rate, negative pressures on the spillway crest and the dimensionless maximum pressures on the gate increase.

Model Tests Study on Flow-induced Vibration of fainter Gate in Estuary Sulices (I) - Flow from the Gate Outside to the Gate Inside - (배수갑문 테인터 게이트(Tainter Gate)의 진동현상에 관한 모형실험 ( I ) - 문비 밖에서 안으로의 흐름 -)

  • Lee, Seong-Haeng
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.1
    • /
    • pp.27-34
    • /
    • 2004
  • A model test is carried out to investigate flow-induced vibration of a Tainter gate in estuary sulices. The gate model scaled with the ratio of 1:25 is made of acryl panel dimensioned 0.66m in width, 0.5m in height in the concrete test flume. Firstly, natural frequencies of the model gate are measured and the results are compared with the numerical results in order to verify the model. The amplitudes of the vibration are measured under the different gate opening and water level conditions in flow from the gate outside to the gate inside. Also 5 revised gate models with bottom width increased 0.5 cm each are tested under the different gate opening and water level. The results are analyzed to study the characteristics of the gate vibration. These test results are assessed in comparison with formerly test results, as a result, presents a design method of Tainter gate to reduce the gate vibration and a basic data for the guide manuals of gate management.

An experimental study on the discharge characteristics of underflow type floating vertical lift gate at free-flow condition (부력식 연직수문의 자유흐름 상태에서 하단방류 특성에 관한 실험적 연구)

  • Han, Il Yeong;Choi, Heung Sik;Lee, Ji Haeng;Ra, Sung Min
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.5
    • /
    • pp.405-415
    • /
    • 2018
  • Hydraulic variables such as discharge coefficient, gate opening, and upstream water depth are required to calculate the discharge of vertical lift gate. It is very important for a precise gate design, because it may affect the rest, to predict the behavior of gate opening during operation. In this study, an equation by which gate opening could be predicted with any upstream water depths was derived from the relation between the calculated value from buoyancy theory and measured one from experiment for a floating gate model. Downpull force was the reason for the differences between the calculated and the measured and it was verified using pressure coefficient. Also, the relation of discharge coefficient with gate opening ratios was derived. The derived relations were used for flood routing and it was realized that downpull force effect should be fully taken into account during gate design.

Dynamic Characteristic of Lift Gate Supported by Plane Truss (평면트러스로 지지된 리프트 게이트의 진동특성)

  • Lee, Seong-Haeng;Yang, Dong-Woon;Hahm, Hyung-Gil;Kong, Bo-Sung;Shin, Dong-Wook
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.3
    • /
    • pp.133-139
    • /
    • 2012
  • Dynamic characteristic of lift gate supported by plane truss is studied by a model test scaled with the ratio of 1 : 31.25 in the four major rivers project. The vibrations of gate supported by the plane truss is assessed in comparison with those of gate supported by the space truss which was tested formerly. The gate model is made of acryl panel and calibrated by lead. A model test is conducted under the different gate opening and upstream water levels conditions in the concrete test flume dimensioned 1.6 m in width, 0.8 m in height and 24 m in length. In order to verify the model, natural frequencies of the model gate are measured, and compared with the numerical results. The vibrations of gate model supported by the plane truss in opening height of 1.0 cm~2.0 cm shows greater than one supported by the space truss. It is found that the gate model supported by the plane truss is less desirable than one supported by the space truss. thus, the latter type of gate model is requested to design.

Study on the Rate-of-Loading by the Differential Pressure of Motor Operated Gate Valves in Opening Stroke (모터구동 게이트밸브 열림행정시 차압 작용에 의한 부하율 연구)

  • Kim, Dae Woong;Park, Sung Ken;Jeoung, Rae Hyuck;Lee, Do Hwan;Hong, Sung Yull
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.166-171
    • /
    • 2004
  • The Rate-of-Loading(ROL) effect of motor operated gate valves causes a decrease in the thrust delivered at a specific torque by the actuator under dynamic flow ${\Delta}$P conditions as compared to the no-flow, static conditions. This effect needs to be studied for the quantitative evaluation of motor operated gate valve operability. This study is performed to verify the validity for the application of ROL in the evaluation of operability of motor operated gate valves for the opening stroke. The ROL is assessed on the basis of in-situ test data for the opening and closing strokes. The results show that the distribution of the ROL for the operling sake has a tendency to the negative value when DP is higher than 150psid.

  • PDF

A Study on the Characteristics of Depositional Landform Change in the Geum River Channel Using Unmanned Aerial Vehicle: Focusing on Before and After the Opening Gate of Gongju Weir (무인항공기를 활용한 금강 하도내의 퇴적지형 변화 특성 연구: 공주보 개방 전·후를 중심으로)

  • Yoon, Hye-Yeon;Yun, Kwang-Sung;JANG, Dong-Ho
    • Journal of The Geomorphological Association of Korea
    • /
    • v.28 no.4
    • /
    • pp.1-13
    • /
    • 2021
  • In this study is aerial photos and UAV(Unmanned Aerial Vehicle) images were used to analyzed the characteristics of depositional landform changes in the Geum river channels before and after the opening gate of Gongju weir. Based on the depositional landform classification result, the main stream and the bare land occupied most of the area in all periods, and also found that the main stream, mid-channel island, and sand bar occupied a greater degree of area increase or decrease compared to other landforms in the classification items. As a result of analyzing the characteristics of depositional landform changes before and after the opening gate of Gongju weir, it is judged that the depositional landforms have changed due to the decreased water level of the Geum river after the opening of the weir, the summer rainy season and typhoons, river stabilization after the effluence of Daecheong dam, supply and deposition of river sediments and fixation of vegetation. The results derived from this study can be used as basic data for the study of river depositional landforms and the establishment of management and conservation plans for the landforms in river channels.

Model Tests Study on Flow-induced Vibrationof Tainter Gate in Estuary Sulices(Ⅱ)- Flow from the Gate Inside to the Gate Outside - (배수갑문 테인터 게이트(Tainter Gate)의 진동현상에 관한 모형실험(Ⅱ)- 문비 안에서 밖으로의 흐름 -)

  • Lee , Seong-Haeng;Woo , Sang-Ik
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.2
    • /
    • pp.41-47
    • /
    • 2004
  • A model test is carried out to investigate flow-induced vibration of a Tainter gate in estuary sulices. The gate model scaled with the ratio of 1:25 is made of acryl panel dimensioned 0.66 m in width, 0.5 m in height in the concrete test flume. Firstly, natural frequencies of the model gate are measured and the results are compared with the numerical results in order to verify the model. In the flow from the gate inside to the gate outside, the amplitudes of the vibration are measured under the different gate opening and downstream water level conditions. Also revised gate models with 20 mm bottom width are tested under the different gate openings and water levels. The results are analyzed to study the characteristics of the Tainter gate vibration in the sea ward flow. These test results are assessed in comparison with the results in the lake ward flow, as a result, presents the dynamic characteristics of the Tainter gate and a basic data for the guide manuals of gate management.

Development of Camera Monitoring System for Detecting the Opening Status of Saemangeum Sluice Gate (새만금 갑문 개폐 자동 영상 관측 시스템 개발)

  • Kim, Tae-Rim;Park, Jong-Jib;Jang, Seong-Woo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.1
    • /
    • pp.73-83
    • /
    • 2011
  • The opening status of Saemangeum sluice gate is an important factor to the coastal water qualities near Saemangeum dikes. The sluice gate opening information is important in analysing current velocity and water quality data measured at the Saemanguem observation tower as well as in determining boundary conditions of numerical simulation for coastal environment outside Saemangeum dikes. This study establishes unmanned camera monitoring system on Saemangeum observation tower using mini notebook and digital camera, and extracts information on the opening status from images automatically. Images are analysed using variance difference of images together with edge detection techniques in order to get correct information.