• Title/Summary/Keyword: Gate Operation

Search Result 822, Processing Time 0.032 seconds

Study on the digitalization of trip equations including dynamic compensators for the Reactor Protection System in NPPs by using the FPGA

  • Kwang-Seop Son;Jung-Woon Lee;Seung-Hwan Seong
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2952-2965
    • /
    • 2023
  • Advanced reactors, such as Small Modular Reactors or existing Nuclear Power Plants, often use Field Programmable Gate Array (FPGA) based controllers in new Instrumentation and Control (I&C) system architectures or as an alternative to existing analog-based I&C systems. Compared to CPU-based Programmable Logic Controllers (PLCs), FPGAs offer better overall performance. However, programming functions on FPGAs can be challenging due to the requirement for a hardware description language that does not explicitly support the operation of real numbers. This study aims to implement the Reactor Trip (RT) functions of the existing analog-based Reactor Protection System (RPS) using FPGAs. The RT equations for Overtemperature delta Temperature and Overpower delta Temperature involve dynamic compensators expressed with the Laplace transform variable, 's', which is not directly supported by FPGAs. To address this issue, the trip equations with the Laplace variable in the continuous-time domain are transformed to the discrete-time domain using the Z-transform. Additionally, a new operation based on a relative value for the equation range is introduced for the handling of real numbers in the RT functions. The proposed approach can be utilized for upgrading the existing analog-based RPS as well as digitalizing control systems in advanced reactor systems.

A multilayered Pauli tracking architecture for lattice surgery-based logical qubits

  • Jin-Ho, On;Chei-Yol Kim;Soo-Cheol Oh;Sang-Min Lee;Gyu-Il Cha
    • ETRI Journal
    • /
    • v.45 no.3
    • /
    • pp.462-478
    • /
    • 2023
  • In quantum computing, the use of Pauli frames through software traces of classical computers improves computation efficiency. In previous studies, error correction and Pauli operation tracking have been performed simultaneously using integrated Pauli frames in the physical layer. In such a complex processing structure, the number of simultaneous operations processed in the physical layer exponentially increases as the distance of the surface code encoding logical qubit increases. This study proposes a Pauli frame management architecture partitioned into two layers for a lattice surgery-based surface code and describes its structure and operation rules. To evaluate the effectiveness of our method, we generated a random circuit according to the gate ratios constituting the commonly known quantum circuits and compared the generated circuit with the existing Pauli frame and our method. Simulations show a decrease of about 5% over traditional methods. In the case of experiments that only increase the code distance of the logical qubit, it can be seen that the effect of reducing the physical operation through the logical Pauli frame becomes more important.

The Design and Implementation of a Graphical Education System on the Structure and the Operation of ALU (ALU 구조와 단계별 연산과정을 그래픽 형태로 학습하는 교육 시스템의 설계 및 구현)

  • Ahn, Syung-Og;Nam, Soo-Jeong
    • The Journal of Engineering Research
    • /
    • v.2 no.1
    • /
    • pp.31-37
    • /
    • 1997
  • This paper describes the design and implementation of 8 bit ALU graphic simulator which helps students who study the structure and operation course of general ALU. ALU of this paper consists of three parts, arithmetic circuit, logic circuit, and shifter. Each of them performs as follows. Arithmetic circuit performs arithmetic operation such as addition, subtraction, 1 increment, 1 decrement, 2's complement, logic circuit performs logic operation such as OR, AND, XOR, NOT, and shifter performs shift operation and transfers the result of circuits of arithmetic, logic to data bus. The instructions which relate to these basic ALU functions was selected from Z80 instructions and ALU circuit was designed with those instructions and this designed ALU circuit was implemented on graphic screen. And all state of this data operation course in ALU was showed by bit and logic gate unit.

  • PDF

Improvement of Physical security System Operation (물리적 보안시스템 운용수준 분석)

  • Chung, Taehwang
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.2
    • /
    • pp.282-286
    • /
    • 2014
  • This study is to present an improvement of physical security system operation by survey on the install and operation of physical security system of 90 facilities. The level of CCTV operation is higher than Access Control system and Intrusion Detection System. But the level of maintenance and management of physical security system is low. The rate of install of X-ray Inspection device show the concern on material detection, although the rate is low. The level of install and operation for the Integration of physical security system is low, so integration of security personnel and security system is necessary for the effective operation. For reinforcement of access control management, security gate and preparing of some obstacles are required with RFID.

A Case Study on the Implementation of Integrated Operation System of the Nakdong River Estuary Barrage Due to the Drainage Gate Extension (낙동강 하굿둑의 배수문 증설에 따른 통합운영시스템의 구축 사례에 대한 연구)

  • Kim, Seokju;Lim, Taesoo;Kim, Minsoo
    • The Journal of Society for e-Business Studies
    • /
    • v.20 no.1
    • /
    • pp.183-199
    • /
    • 2015
  • Due to the Four Major Rivers Restoration Project, Nakdong River Estuary Barrage's designed flood quantity has been largely increased, and this has caused to construct several drainage gates at the right side of Eulsukdo island to secure the safety of downstream river area. For successful functioning of Nakdong River Estuary Barrage, such as flood control, disaster prevention, and the securing of sufficient water capacity, drainage gates at the both sides of island have to operate systematically and reliably. To manage this under restricted personnel and resources, we have implemented the IOS (Integrated Operation System) by integrating previous facilities and resources via information and communication technologies. The IOS has been designed to have higher availability and fault tolerance to function continuously even with the partial system's failure under the emergency situation like flood. Operators can use the system easily and acknowledge alarms of facilities through its IWS (Integrated Warning System) earlier. Preparing for Integrated Water Resources Management and Smart Water Grid, the architecture of IOS conformed to open system standards which will be helpful to link with the other systems easily.

Temporal changes in river channel habitat diversity by large weirs in the Geum River using satellite imagery analysis (위성영상 분석을 통한 금강수계 대형보에 따른 수변서식처 다양성 변화 연구)

  • Ock, Giyoung;Choi, Mikyoung;Kim, Jeong-Cheol;Park, Hyung-Geun
    • Korean Journal of Environmental Biology
    • /
    • v.38 no.4
    • /
    • pp.705-713
    • /
    • 2020
  • The present study investigated the temporal changes of river habitats caused by construction and operation of the three large weirs (Sejong, Gongju, and Baekje) in the Geum River. High resolution satellite imagery taken during three periods (preconstruction, before and after gate operation) were used for habitat analysis. We divided bar area into eight habitat types in addition to water area. Then, we identified the nine habitat types from the satellite imagery and estimated each habitat area. Our results show that after weir construction, large bar areas were dramatically decreased and bareland was nearly absent post gate-operation in all three weirs. However, total bar area and bareland were again increased distinctively soon after weir opening events, especially in the uppermost weir, the Sejongbo. These results suggest that weir opening operations provide a relatively simple channel of more diverse through the process of increasing bar area in a river channel.

Operation analysis and application of modified slope-area method for the estimation of discharge in multi-function weir (다기능보의 방류량 산정 개선을 위한 운영 분석 및 수정 경사-면적법의 적용)

  • Oh, Ji-Hwan;Jang, Suk-Hwan;Oh, Kyoung-Doo
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.8
    • /
    • pp.687-701
    • /
    • 2018
  • A multi-function weir is representative control structure in the stream flow. Estimation of accurate flood discharge according to gate operations and prediction of floodwave travel times at the downstream are very important in terms of water use and river management. This study analyzed the limitation and improvement through the current gate operation data on the Young-san river. in addition, flood discharge was calculated considering lower and upper water level condition and gate operating using the modified slope-area method in the Seoung-chon weir. As a result, the current state was required improvement because exceed the theoretical range and rapidly fluctuation of discharge coefficient, can not be considered difference between the upper and lower water level and the estimation by the regression equation. As a result of applying the proposed method in this study, the above mentioned limitations can be compensated, compared with the current discharge data. Also it was analyzed as more physically valid because using the evaluated hydraulic equation and estimate the slope and friction loss of natural stream by iteration and to reduce the error. In conclusion, the process carried out serves as a representative flow control point of the water system through reliable discharge estimation, it is expected that it will be possible to properly river management.

A Study on the Warpage of Glass Fiber Reinforced Plastics for Part Design and Operation Condition: Part 1. Amorphous Plastics (유리섬유로 보강된 수지에서 제품설계 및 성형조건에 따른 휨의 연구: Part 1. 비결정성 수지)

  • Lee, Min;Kim, Hyeok;Lyu, Min-Young
    • Polymer(Korea)
    • /
    • v.36 no.5
    • /
    • pp.555-563
    • /
    • 2012
  • Warpage of injection molded product is caused by non-uniform shrinkage during shaping operation and relaxation of residual stress. Robust part design and glass fiber reinforced reins have been adopted to prevent warpage of part. Warpages for part designs have been investigated in this study according to the injection molding conditions. Part design contains flat specimen and two different rib designs in the flat part. Resins used in this study were glass fiber reinforced amorphous plastics, PC and ABS. Different rib designs showed significant differences of warpages in the parts. Various warpages have been observed in the three regions of the part, near gate region, opposite region to the gate, and flow direction region. Results of computer simulation revealed that the warpages were strongly related to glass fiber orientation. Flat specimen showed the smallest warpage and the specimen with ribs to the flow direction showed a high resistance to warpage. Warpage highly depended upon part design rather than molding condition. It was concluded that the rib design and selection of gate location in injection molding would be the most important factors for the control of warpage since those are directly related to the fiber orientation during molding.

High resolution flexible e-paper driven by printed OTFT

  • Hu, Tarng-Shiang;Wang, Yi-Kai;Peng, Yu-Rung;Yang, Tsung-Hua;Chiang, Ko-Yu;Lo, Po-Yuan;Chang, Chih-Hao;Hsu, Hsin-Yun;Chou, Chun-Cheng;Hsieh, Yen-Min;Liu, Chueh-Wen;Hu, Jupiter
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.421-427
    • /
    • 2009
  • We successfully fabricated 4.7-inch organic thin film transistors array with $640{\times}480$ pixels on flexible substrate. All the processes were done by photolithography, spin coating and ink-jet printing. The OTFT-Electrophoretic (EP) pixel structure, based on a top gate OTFT, was fabricated. The mobility, ON/OFF ratio, subthreshold swing and threshold voltage of OTFT on flexible substrate are: 0.01 ^2/V-s, 1.3 V/dec, 10E5 and -3.5 V. After laminated the EP media on OTFT array, a panel of 4.7-inch $640{\times}480$ OTFT-EPD was fabricated. All of process temperature in OTFT-EPD is lower than $150^{\circ}C$. The pixel size in our panel is $150{\mu}m{\times}150{\mu}m$, and the aperture ratio is 50 %. The OTFT channel length and width is 20 um and 200um, respectively. We also used OTFT to drive EP media successfully. The operation voltages that are used on the gate bias are -30 V during the row data selection and the gate bias are 0 V during the row data hold time. The data voltages that are used on the source bias are -20 V, 0 V, and 20 V during display media operation.

  • PDF

A Study of Hydrodynamics and Reaction Characteristics in Relation to the Desulfurization Temperatures of Zn-Based Solid Sorbent in the Lab-scale High Pressure and High Temperature Desulfurization Process (실험실규모 고온고압건식탈황공정의 수력학적 특성 및 탈황온도에 따른 아연계 탈황제의 반응특성 연구)

  • Kyung, Dae-Hyun;Kim, Jae-Young;Jo, Sung-Ho;Park, Young Cheol;Moon, Jong-Ho;Yi, Chang-Keun;Baek, Jeom-In
    • Korean Chemical Engineering Research
    • /
    • v.50 no.3
    • /
    • pp.492-498
    • /
    • 2012
  • In this study, hydrodynamics such as solid circulation rate and voidage in the desulfurizer and the reaction characteristics of Zn-based solid sorbents were investigated using lab-scale high pressure and high temperature desulfurization process. The continuous HGD (Hot Gas Desulfurization) process consist of a fast fluidized bed type desulfurizer (6.2 m tall pipe of 0.015 m i.d), a bubbling fluidized bed type regenerator (1.6 m tall bed of 0.053 m i.d), a loop-seal and the pressure control valves. The solid circulation rate was measured by varying the slide-gate opening positions, the gas velocities and temperatures of the desulfurizer and the voidage in the desulfurizer was derived by the same way. At the same gas velocities and the same opening positions of the slide gate, the solid circulation rate, which was similar at the temperature of $300^{\circ}C$ and $550^{\circ}C$, was low at those temperatures compared with a room temperature. The voidage in the desulfurizer showed a fast fluidized bed type when the opening positions of the slide gate were 10~20% while that showed a turbulent fluidized bed type when those of slide gate were 30~40%. The reaction characteristics of Zn-based solid sorbent were investigated by different desulfurization temperatures at 20 atm in the continuous operation. The $H_2S$ removal efficiency tended to decrease below the desulfurization temperature of $450^{\circ}C$. Thus, the 10 hour continuous operation has been performed at the desulfurization temperature of $500^{\circ}C$ in order to maintain the high $H_2S$ removal efficiency. During 10 hour continuous operation, the $H_2S$ removal efficiency was above 99.99% because the $H_2S$ concentration after desulfurization was not detected at the inlet $H_2S$ concentration of 5,000 ppmv condition using UV analyzers (Radas2) and the detector tube (GASTEC) which lower detection limit is 1 ppmv.