• 제목/요약/키워드: Gases Concentrations

검색결과 283건 처리시간 0.029초

3D 프린팅을 이용한 Pt/Carbon Nanotube composite 기반 전기화학식 황화수소 가스 센서 제작 (Fabrication of Pt/Carbon Nanotube Composite Based Electrochemical Hydrogen Sulfide Gas Sensor using 3D Printing)

  • 하윤태;권진범;최수지;정대웅
    • 센서학회지
    • /
    • 제32권5호
    • /
    • pp.290-294
    • /
    • 2023
  • Among various types of harmful gases, hydrogen sulfide is a strong toxic gas that is mainly generated during spillage and wastewater treatment at industrial sites. Hydrogen sulfide can irritate the conjunctiva even at low concentrations of less than 10 ppm, cause coughing, paralysis of smell and respiratory failure at a concentration of 100 ppm, and coma and permanent brain loss at concentrations above 1000 ppm. Therefore, rapid detection of hydrogen sulfide among harmful gases is extremely important for our safety, health, and comfortable living environment. Most hydrogen sulfide gas sensors that have been reported are electrical resistive metal oxide-based semiconductor gas sensors that are easy to manufacture and mass-produce and have the advantage of high sensitivity; however, they have low gas selectivity. In contrast, the electrochemical sensor measures the concentration of hydrogen sulfide using an electrochemical reaction between hydrogen sulfide, an electrode, and an electrolyte. Electrochemical sensors have various advantages, including sensitivity, selectivity, fast response time, and the ability to measure room temperature. However, most electrochemical hydrogen sulfide gas sensors depend on imports. Although domestic technologies and products exist, more research is required on their long-term stability and reliability. Therefore, this study includes the processes from electrode material synthesis to sensor fabrication and characteristic evaluation, and introduces the sensor structure design and material selection to improve the sensitivity and selectivity of the sensor. A sensor case was fabricated using a 3D printer, and an Ag reference electrode, and a Pt counter electrode were deposited and applied to a Polytetrafluoroethylene (PTFE) filter using PVD. The working electrode was also deposited on a PTFE filter using vacuum filtration, and an electrochemical hydrogen sulfide gas sensor capable of measuring concentrations as low as 0.6 ppm was developed.

An Embedded system for real time gas monitoring using an ART2 neural network

  • Cho, Jung-Hwan;Shim, Chang-Hyun;Lee, In-Soo;Lee, Duk-Dong;Jeon, Gi-Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.479-482
    • /
    • 2003
  • We propose a real time gas monitoring system for classifying various gases with different concentrations. Using thermal modulation of operating temperature of two sensors, we extract patterns of gases from the voltage across the load resistance. We adopt the relative resistance as a pre-processing method and an ART2 neural network as a pattern recognition method. The proposed method has been implemented in a real time embedded system with tin oxide gas sensors, TGS 2611, 2602 and an MSP430 ultra-low power microcontroller in the test chamber.

  • PDF

위험스런 지구 온난화 경향 무엇이 원인인가? (Rapidity of Recent Global Warming : What Factors are Important\ulcorner)

  • 김문일
    • 한국대기환경학회지
    • /
    • 제9권1호
    • /
    • pp.1-10
    • /
    • 1993
  • A brief description on the greenhouse gases, the greenhoue effect, sea level changes, forcing of climate, the history of Earth's changing climate based on the IPCC REPORT and the records of the recent variation of the climate in the Republic of Kore is presented here for help enhancing awareness of the issues. The climate of the Earth has the potential to be changed on all timescales by the fluctuations of the concentrations of radioactively active greenhouse gases, solar radiation, aerosols and albedo. However, the rate of the recent global warming seems to be larger and rapid than any have occurred thorughout recorded history enough to draw the world-wide attention and worry concerned with the theme of environment and development. There are still uncertainties in the predictions relating to the timing, magnitude and the pattern of the climatic change due to the current incomplete understanding of various aspects of the complex processes. Nonetheless, the scientific results avaliable is sufficient to allow for decisive precautionary measures to be taken.

  • PDF

스모그 챔버에서 수분 반응에 의한 대기 에어로졸의 생성 및 성장 (Formation and Growth of Atmospheric Aerosols by Water Vapor Reactions in an Indoor Smog Chamber)

  • 김민철;배귀남;문길주;박주연
    • 한국대기환경학회지
    • /
    • 제20권2호
    • /
    • pp.161-174
    • /
    • 2004
  • Aerosol formation and growth by water vapor reactions were investigated in a 2.5 -㎥ indoor smog chamber filled with the unfiltered ambient air. The relative humidity of test ambient air was elevated at 59~64% or 84~88% by adding water vapor. The aerosol number size distribution and the concentrations of $O_3$, NO, NO$_2$, and SO$_2$ were measured during the experiments. The $O_3$ and NO$_2$ gases were well reacted with the water vapor at high relative humidity of 84~88%, and the reaction rates of these gases seemed to be decreased at low relative humidity of 59~64%. The formation and condensational growth phenomena of ambient aerosols by water vapor reactions were observed in a Teflon bag, depending strongly on the initial particle size distribution. The water vapor reactions might be affected by the contents of oxidants produced by photochemical reactions under sunlight.

유기 가스 검지를 위한 다공질 실리콘층의 전기 저항 의존성 (Dependence of Electrical Resistance in Porous Silicon Layer for Detecting Organic Vapors)

  • 박광열;김성진;이상훈;최복길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.792-796
    • /
    • 2002
  • In this work, porous silicon(PS) layer is used as a sensing material to detect organic gases. To do this, PS sensors with membrane structure are fabricated. The sensors were made by applying the technologies of membrane formation by anisotropic etching of silicon, and PS layer formation by anodization in HF solution. From fabricated sensors, current-voltage (I-V) curves were measured against ethanol (called alcohol), methanol and acetone gases evaporated from 0.1 to 0.5% solution concentrations at $36^{\circ}C$. As the result, all curves showed rectifying behavior due to a diode structure between Si and PS, and the conductance of sensor devices increased largely with the organic solution concentration at high voltage of 5V.

  • PDF

선박용 주방후드 환기시스템에 관한 수치해석 (Numerical Analysis of the Kitchen Hood Ventilation System for Marine Environment)

  • 이중섭
    • 한국기계가공학회지
    • /
    • 제14권5호
    • /
    • pp.96-101
    • /
    • 2015
  • This study regards distributions of flow in the ventilation system used in the kitchen hood in a ship. In this study, for describing the flow in the ventilation system, three-dimensional steady-state turbulence was assumed for the governing equation. When the plume was formed, three gases, CO, CO2, and HCL, in the flow field of the hood were considered as the plume, and it was assumed that the sum of concentrations of the gases was 100%. As a result, it could be confirmed that the plume was smoothly discharged when the flow rate of the supply was ten times lower than that of the exhaust.

접촉연소식 가스 센서의 검지특성 (Detecting Characteristics of Catalytic Combustible Gas Sensor)

  • 박찬원;원창섭;유영한;안형근;한득영
    • 한국전기전자재료학회논문지
    • /
    • 제13권10호
    • /
    • pp.865-870
    • /
    • 2000
  • In this paper, catalytic combustible gas sensor was fabricated and tested under flammable gases such as CH$_4$and $C_4$H$_{10}$by using Pt coil as a heater and/or temperature sensing element. Fine $Al_2$O$_3$powder was used for a bead and Pt, Pd noble metal powder for a catalyst. Resistance variation of Pt wire was traced by the changes of the gas concentrations in a chamber. Output voltage was then monitored to obtain the gas concentration from the resistance variation. In this experiment, MgO was used to protect cracks in the based and TiO$_2$to increase the sensitivity of the sensors. Water glass was also added to enhance the selectivity to the combustible gases.s.

  • PDF

제트확산화염에서의 불활성기체 소화농도 (Flame- Extinguishing Concentrations of Inert Gases in Jet Diffusion Flames)

  • 지정훈;이의주
    • 한국안전학회지
    • /
    • 제24권1호
    • /
    • pp.21-25
    • /
    • 2009
  • Extinguishing limits of laminar ethylene/oxygen flames in both normal and inverse co-flow jet burner have been determined experimentally and computationally. An inert gas($N_2$, Ar, $CO_2$) was added into the oxidizer to find the critical concentration and the effectiveness of the agents on flame extinction. The experimental results showed that the physical aspect of inert gases was main mechanism for flame blow-out as same as cup burner test, but the flow effect should be considered to determine the extinction concentration. The numerical prediction was performed with modified WSR model and the result was in good agreement with the measurements. The experimental and numerical methods could be used for the assessment of various flame suppression agents such as minimum extinguishing concentration.

2022년 5월 31일 발생한 밀양산불이 인근 도시 지역의 미세먼지 농도에 미치는 영향 (Effect of May 31, 2022 Miryang Forest Fire on Fine Particle Concentration in Nearby Urban Areas)

  • 전병일
    • 한국환경과학회지
    • /
    • 제32권1호
    • /
    • pp.37-46
    • /
    • 2023
  • This study investigated the effect of May 31, 2022 Miryang wildfire on fine particle concentrations in Busan and Gimhae, which are neighboring urban areas. In addition, fine particle characteristics and air pollution concentrations were investigated in Miryang, where haze occurred. The Miryang city wildfire that occurred on May 31, 2022, at 0925 LST, was driven by strong north winds and increased fine particle concentrations in Dongsangdong and Jangyoodong, Gimhae City, which are approximately 35 km to the southeast and south, respectively, of the wildfire occurrence site. Furthermore, the fine particle concentration in Myeongjidong, which is approximately 50 km south-southeast of the wildfire site, exhibited a temporary increase at 1400 LST owing to the effects of wildfire smoke. On the morning of June 1, the day after the fire, the Miryang area had very bad visibility because of the smoke from the fire. Therefore the PM10 and PM2.5 concentrations in Naeildong, 3 km south of the wildfire site, were 276 ㎍/㎥ and 222 ㎍/㎥, respectively, at 1200 LST. In addition, the gases O3, CO, and SO2 showed high concentrations at the time of haze generation. This study provides insights into policy making in response to the rapid increase in fine dust when wildfire occurs near cities.

배출가스 중 응축성미세먼지 특성 연구 (A Study on the Characteristics of Condensable Fine Particles in Flue Gas)

  • 공부주;김종현;김혜리;이상보;김형천;조정화;김정훈;강대일;박정민;홍지형
    • 한국대기환경학회지
    • /
    • 제32권5호
    • /
    • pp.501-512
    • /
    • 2016
  • The study evaluated methods to measure condensable fine particles in flue gases and measured particulate matter by fuel and material to get precise concentrations and quantities. As a result of the method evaluation, it is required to improve test methods for measuring Condensable Particulate Matter (CPM) emitted after the conventional Filterable Particulate Matter (FPM) measurement process. Relative Standard Deviation (RSD) based on the evaluated analysis process showed that RSD percentages of FPM and CPM were around 27.0~139.5%. As errors in the process of CPM measurement and analysis can be caused while separating and dehydrating organic and inorganic materials from condensed liquid samples, transporting samples, and titrating ammonium hydroxide in the sample, it is required to comply with the exact test procedures. As for characteristics of FPM and CPM concentrations, CPM had about 1.6~63 times higher concentrations than FPM, and CPM caused huge increase in PM mass concentrations. Also, emission concentrations and quantities varied according to the characteristics of each fuel, the size of emitting facilities, operational conditions of emitters, etc. PM in the flue gases mostly consisted of CPM (61~99%), and the result of organic/inorganic component analysis revealed that organic dusts accounted for 30~88%. High-efficiency prevention facilities also had high concentrations of CPM due to large amounts of $NO_x$, and the more fuels, the more inorganic dusts. As a result of comparison between emission coefficients by fuel and the EPA AP-42, FPM had lower result values compared to that in the US materials, and CPM had higher values than FPM. For the emission coefficients of the total PM (FPM+CPM) by industry, that of thermal power stations (bituminous coal) was 71.64 g/ton, and cement manufacturing facility (blended fuels) 18.90 g/ton. In order to estimate emission quantities and coefficients proper to the circumstances of air pollutant-emitting facilities in Korea, measurement data need to be calculated in stages by facility condition according to the CPM measurement method in the study. About 80% of PM in flue gases are CPM, and a half of which are organic dusts that are mostly unknown yet. For effective management and control of PM in flue gases, it is necessary to identify the current conditions through quantitative and qualitative analysis of harmful organic substances, and have more interest in and conduct studies on unknown materials' measurements and behaviors.