• 제목/요약/키워드: Gaseous

검색결과 1,368건 처리시간 0.021초

$CO_2$/NOx-free 50kW 매체순환식 가스연소기 산화-환원 연속반응 실증 (Continuous Operation of $CO_2$/NOx-free 50kW Checmial-Looping Combustor)

  • 류호정;진경태;이창근
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제28회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.227-234
    • /
    • 2004
  • For gaseous fuel combustion with inherent $CO_2$ capture and low NOx emission, chemical-looping combustion(CLC) may yield great advantages of savings of energy to $CO_2$ separation and suppressing the effect on environment. In chemical-looping combustor, fuel is oxidized by metal oxide medium (oxygen carrier particle) in a reduction reactor. Reduced particles are transported to oxidation reactor and oxidized by air and recycled to reduction reactor. The fuel and the air are never mixed, and the gases from reduction reactor, $CO_2$ and $H_2O$, leave the system as separate stream. The $H_2O$ can be easily separated by condensation and pure $CO_2$ is obtained without any loss of energy for separation. The purpose of this study is to demonstrate inherent $CO_2$ separation and no NOx emission and to confirm high $CO_2$ selectivity, no side reaction (i.e., carbon deposition, hydrogen generation) by continuous reduction and oxidation experiment in a 50kWtb chemical-looping combustor. NiO/bentonite particle was used as a bed material and $CH_4$ and air were used as reacting gases for reduction and oxidation respectively.

  • PDF

미분탄 보일러 연소 해석에서 석탄 반응 모델 및 난류 혼합 속도의 영향 평가 (Influence of Coal Conversion Model and Turbulent Mixing Rate in Numerical Simulation of a Pulverized-coal-fired Boiler)

  • 양주향;김정은;류창국
    • 한국연소학회지
    • /
    • 제20권3호
    • /
    • pp.35-42
    • /
    • 2015
  • Investigating coal combustion in a large-scale boiler using computational fluid dynamics (CFD) requires a combination of flow and reaction models. These models include a number of rate constants which are often difficult to determine or validate for particular coals or furnaces. Nonetheless, CFD plays an important role in developing new combustion technologies and improving the operation. In this study, the model selection and rate constants for coal devolatilization, char conversion, and turbulent reaction were evaluated for a commercial wall-firing boiler. The influence of devolatilization and char reaction models was found not significant on the overall temperature distribution and heat transfer rate. However, the difference in the flame shapes near the burners were noticeable. Compared to the coal conversion models, the rate constant used for the eddy dissipation rate of gaseous reactions had a larger influence on the temperature and heat transfer rate. Based on the operation data, a value for the rate constant was recommended.

탈휘발 과정과 촤가스화 과정에서 목질계 바이오매스의 타르발생 특성 (Characteristics of Tar Generation during the interval of Gasification of Woodchip)

  • 문지홍;이은도;류창국;이영만;배우근
    • 한국연소학회지
    • /
    • 제16권1호
    • /
    • pp.8-14
    • /
    • 2011
  • Biomass gasification is a promising technology in terms of clean energy and flexible options for end use such as heat, steam, electricity, gaseous or liquid fuels. In a gasification process, reduction of tar is very important because it can cause any mechanical problems and small tar implies high energy efficiency. However, generation and conversion mechanisms of tar have not been fully understood due to its complex nature. In this study, characteristics of tar generated from different gasification stages were investigated. Korean pine woodchip was used as feedstock and tar was sampled in a separate way during devolatilization and char gasification stage, investigated. As a result. more various kinds of hydro carbon compounds were identified in the devolatilization stage than char gasification stage because primary tar compounds are released mostly from pyrolysis of cellulose and hemicellulose. When the reaction temperature increased up to $900^{\circ}C$, tar composition becomes simplified into about 10 aromatic compounds mostly with 1-4 rings without substitution up to phenanthrene. The sampled tar in the char gasification stage mostly contains 5-7 simple aromatic compounds.

Bacterial Dynamics of Biofilm Development During Toluene Degradation by Burkholderia vietnamiensis G4 in a Gas Phase Membrane Bioreactor

  • Kumar, Amit;Dewulf, Jo;Wiele, Tom Van De;Langenhove, Herman Van
    • Journal of Microbiology and Biotechnology
    • /
    • 제19권9호
    • /
    • pp.1028-1033
    • /
    • 2009
  • In this study, the dynamics of living cells (LC) and dead cells (DC) in a laboratory-scale biofilm membrane bioreactor for waste gas treatment was examined. Toluene was used as a model pollutant. The bacterial cells were enumerated as fluoromicroscopic counts during a 140 operating day period using BacLight nucleic acid staining in combination with epifluorescence and confocal laser scanning microscopy (CSLM). Overall, five different phases could be distinguished during the biofilm development: (A) cell attachment, (B) pollutant limitation, (C) biofilm establishment and colonization, (D) colonized biofilm, and (E) biofilm erosion. The bioreactor was operated under different conditions by applying different pollutant concentrations. An optimum toluene removal of 89% was observed at a loading rate of 14.4 kg $m^{-3}d^{-1}$. A direct correlation between the biodegradation rate of the reactor and the dynamics of biofilm development could be demonstrated. This study shows the first description of biofilm development during gaseous toluene degradation in MBR.

RF magnetron 스파터링법으로 제작한 TiNx 박막의 면저항분석 (Sheet Reisistance Analysis of TiNx Thin Film by RF Magnetron Sputtering)

  • 박문찬;오정홍;김남영;황보창권
    • 한국안광학회지
    • /
    • 제4권1호
    • /
    • pp.21-25
    • /
    • 1999
  • RF(radio-frequency) magnetron 스퍼터링 장치에 질소가스와 아르곤가스를 동시에 주입하면서 Ti 타켓을 스퍼터링하여 TiN, 박막을 유리기판위에 제작하였다. 박막제작시 RF power supply 출력은 240W로, 증착기 내부의 온도는 $200^{\circ}C$를 유지하였다. TiN, 박막은 알곤 가스를 20sccm으로 고정시킨 상태에서 질소를 3sccm부터 9secm까지 변화시켜가며 증착시켰다. 이때 박막의 면저항과 화학적 조성과의 관계를 분석하기 위하여 XPS depth profiling과 4점 탐침법을 사용하였다.

  • PDF

대기오염측정에 대한 정도관리의 필요성 - 1998년도 한국대기환경학회 측정분석분과회의 실험실간 비교분석사업 시행과 전개방향 (The Need for QA/QC in the Measurements of Airborne Pollutants - Conduction of and Directions towards an Interlaboratory Comparison Test in 1998 by the Measurement and Analysis Division of KOSAE)

  • 김기현;이강웅;김조천;서영화;이종해;허귀석
    • 한국대기환경학회지
    • /
    • 제15권1호
    • /
    • pp.63-69
    • /
    • 1999
  • To offer a general guideline for the quantitative analysis of airborne pollutants, we designed and conducted a comprehensive QA/QC test using two different strategic approaches, namely (1) field-based comparative measurement and (2) laboratory-based comparative analysis. The former task was performed to make meaningful comparison of combined errors occurring from both sampling and analytical techniques in the measurements of such components as: (1) criteria pollutants, (2) volatile organic compounds (VOCs), and (3) particulate matters with the associated metals and ions. The latter task was also conducted to compare various types of bias arising mainly from the laboratory analytical procedures of (1) gaseous standards of VOCs and (2) of aqueous standards of metals and ions. The concentration data derived from each of these two different types of major tasks were evaluated per chemical species categorized as above. While the very details of these studies are to be reported on an individual basis according to the above classification of the project, this paper is presented to provide an overview of the whole project - its aim and direction.

  • PDF

미세입자(PM2.5) 측정시 발생되는 질산염(NO3-) 휘발에 관한 연구 (A Study on the Volatilization of Particulate Nitrate (NO3-) During Fine Particle (PM2.5) Measurement)

  • 강병욱;이학성
    • 한국대기환경학회지
    • /
    • 제18권4호
    • /
    • pp.297-303
    • /
    • 2002
  • Fine particles (d$_{p}$ < 2.5 $\mu$m) were measured using an annular denuder system (ADS) in Chongju. The data set was collected on fifty-eight different days with a 24-hr sampling period from October 27, 1995 through August 25, 1996. Particulate nitrate in the ADS was also measured on teflon and nylon filters in series behind denuders to collect HNO$_3$, HNO$_2$, SO$_2$and NH$_3$. From this study. the mean concentration of particulate nitrate of PM$_{2.5}$ in the ADS were seen with the following order: winter (5.05) >fall (4.36) >spring (3.92) > summer (1.10 $\mu\textrm{g}$/㎥). Nitrate losses, which calculated from the ratio of nylon filter nitrate to the sum of teflon and nylon filter nitrates, varied in the following manner summer (72.2%) > spring (42.6%) > fall (23.5%)> winter (0.4%). Especially, gaseous nitric acid was dominant at temperature higher than 8$^{\circ}C$ while particulate nitrate was major species in total nitrate below that temperature. This indicates the particulate nitrate loss is strongly correlated rather with ambient temperature.e.e.

금속담지 활성알루미나 촉매의 암모니아 저온연소반응 (Catalytic Oxidation of Ammonia over Metal Supported on Alumina at Low Temperature)

  • 임윤희;이주열;박병현
    • 한국응용과학기술학회지
    • /
    • 제30권3호
    • /
    • pp.371-379
    • /
    • 2013
  • In order to improve the selective oxidation reaction of gaseous ammonia at a low temperature, various types of metal-impregnated activated alumina were prepared, and also physical and chemical properties of the conversion of ammonia were determined. Both types of metal (Cu, Ag) impregnated activated alumina show high conversion rate of ammonia at high temperature (over $300^{\circ}C$). However, at lower temperature ($200^{\circ}C$), Ag-impregnated catalyst shows the highest conversion rate (93%). In addition, the effects of lattice oxygen of the developed catalyst was studied. Ce-impregnated catalyst showed higher conversion rate than commercial alumina, but also showed lower conversion rate than Ag-impregnated sample. Moreover, 5 vol.% of Ag activation under hydrogen shows the highest conversion rate result. Finally, through high conversion at low temperature, it was considered that the production of NO and $NO_2$, toxic by-products, were effectively inhibited.

자동차에서 배출되는 가스상 유해대기오염물질 (HAPs) 배출량 추정 (Estimation of Gaseous Hazardous Air Pollutants Emission from Vehicles)

  • 김정;장영기;최상진;김정수;서충열;손지환
    • 한국대기환경학회지
    • /
    • 제29권1호
    • /
    • pp.1-9
    • /
    • 2013
  • Hazardous Air Pollutants (HAPs) are difficult to measure, analyze and assess for risk because of low ambient concentrations and varieties. Types of HAPs are Volatile organic compounds (VOCs), Polycyclic aromatic hydrocarbon (PAHs) and Aldehydes. HAP emissions from vehicles are a contributor to serious adverse health effects in urban areas. In this study, hazardous air pollutant emissions from road transport vehicles by Non-methane volatile organic compounds (NMVOC) weight fraction and PAHs emission factors are estimated in 2008. The top-five-most hazardous air pollutant emissions were estimated to toluene 864.3 ton/yr, acrolein 690.6 ton/yr, acetaldehyde 554.5 ton/yr, formaldehyde 498.7 ton/yr, propionaldehyde 421.6 ton/yr in 2008. The results for a cancer and non-cancer risk assessment of HAPs emissions show that the major cancer driver is formaldehyde and the non-cancer driver is acrolein.

고온초전도 시스템의 새로운 냉각기술 (New Cooling Techniques of High Tc Superconductor Systems)

  • 장호명
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 1999년도 High Temperature Superconductivity Vol.IX
    • /
    • pp.7-11
    • /
    • 1999
  • The recent progress in new cooling techniques of the high Tc superconductor(HTS) systems is reported and discussed with some practical examples. At the beginning stage of the HTS development in research laboratories, liquid nitrogen(LN$_2$) is the standard medium for an effective cooling. The success of HTS in many different application areas, however, has required a variety of need in the cooling temperature and the cooling capacity with specific design restrictions. While the utilization of alternative liquid cryogens such as liquid neon (LNe) or liquid hydrogen (LH$_2$) has been tired in some of them, even solid cryogens such as solid nitrogen (SN$_2$) or solid hydrogen (SH$_2$) may be another option in special applications. The gaseous helium cooled by a cryogenic refrigerator has also been a good candidate in many cases. One of the best cooling methods for the HTS is the direct conduction-cooling by a closed-cycle refrigerator with no cryogen at all. The refrigeration may be based on Joul-Thomson, Brayton, Stirling, Gifford-McMahon, or pulse tube cycles. The pros and cons of the newly proposed cooling methods are described and some significant design issues are presented.

  • PDF