• Title/Summary/Keyword: Gaseous

Search Result 1,368, Processing Time 0.022 seconds

Identifuication of College Student's And Teacher's Conceptions for Chemical Equilibrium and Equilibrium Shift (화학평형과 평형이동에 대한 대학생과 교사들의 개념조사)

  • Park, Jong Yun;Park, Hyeon Ju
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.3
    • /
    • pp.265-278
    • /
    • 2002
  • A concept test was administered to college students and teachers to identify their understanding of chemical equilibrium and equilibrium shift. The subjects were 53 freshmen in the General Chemistry class, 28 juniors in the Physical Chemistry class and 26 seniors from a university and 10 high school teachers in Seoul. Test items include the calculations of partial pressure and concentration of the gas in the mixture, the equilibrium constant cal-culation and the prediction of equilibrium shift when an inert gas is added to the gaseous reaction system, and the equilibrium concentration calculation and the prediction of equilibrium shift when water or common ion is added to the weak acid solution. The test was focused to identify whether the subjects can predict equilibrium shift using the reaction quotient change for the situations in which Le Chatelier principle is difficult to apply. The results showed that the achievements of teachers and juniors were significantly higher than those of freshmen and seniors. Many stu-dents had difficulties in predicting equilibrium shift using the reaction quotient while they could calculate partial pres-sure and concentration for the same situation. It means they are lack of conceptual understanding of chemical equilibrium shift.

Dielectric Characteristics of Gaseous $SF_6$ for Impulse Voltages in Presence of a Metallic Particle in GIS (가스절연개폐장치에 있어서 금속입자 존재시 임펄스전압에 대한 $SF_6$가스의 절연특성)

  • 이복희;이경옥;이창준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.22-29
    • /
    • 2000
  • This paper deals with the dielectric characteristics of $SF_6$ gas gap stressed by $\pm$1.2/44[$mutextrm{s}$] non-oscillating impulse and $\pm$0.4[$mutextrm{s}$]/1.14[MHz] oscillating impulse voltages in the presence of a needle-shape metallic particle in gas-insulated switchgear(GIS). Breakdown voltage-time (V-t) and breakdown voltage-gas pressure (V-p) characteristics were investigated and discussed. The experiments were carried out under highly inhomogeneous field geometry with a needle protrusion whose length and radius are 10[mm] and 0.5[mm], respectively. The gas pressure ranges from 0.1 to 0.5[㎫]. As a result, it was found that the electrical breakdown for both the positive and negative polarity develops with steplike pulses in leader mechanism, When subjected to the positive oscillating impulse voltage, the minimum breakdown voltages appeared in all the gas pressure ranges and the V-t curves have a pronounced upturning at short times to breakdown and give a little dependence of the gas pressure. On the other hand, in the case of the negative polarity the dependence of the V-t and V-p characteristics on the wave shape of the applied voltages is known to be appreciable.

  • PDF

Studies on the Behavior of SO2 and NOx over Yellow Sea Area during Long Term Aircraft Measurements(1997~2007) (장기간(1997~2007) 창공관측을 이용한 서해상 SO2 및 NOx의 거동 연구)

  • Song, Hyung-Do;Choi, Jin-Soo;Jang, Im-Suk;Kim, Jeong-Soo;Lee, Suk-Jo
    • Journal of Environmental Science International
    • /
    • v.18 no.5
    • /
    • pp.569-578
    • /
    • 2009
  • Aircraft Measurements of gaseous pollutants($SO_2$, NOx and $O_3$) in the Yellow Sea area, were carried out on 1997-2007. Main measurement site in 124$^{\circ}$-127$^{\circ}$E, 35$^{\circ}$-37$^{\circ}$N (in the Yellow Sea), have been done along the paths classified vertically and zonally. To understand how the air stream affects Long-range transboundary pollutants in Northease Asia (LTP), the tracks of pollutants in northeast Asia have been analyzed by dividing into 6 different regions(regions I-V and L). Compared with Korea's local sources and western north Pacific influenced by the Yellow Sea, when the air stream from region II is dominant, the $SO_2$ concentrations are 3-6times higher. In region II and III, $SO_2$ concentrations are represented highest at 25.0 and 14.7 ppb, respectively. However, in other regions, $SO_2$ concentration was recorderd the highest at 1.1-3.8 ppb, which is 7-15% higher then the highest one over the region II and III. During 1997-2007, the mean amount of incoming pollutants is 0.162 $ton/km{\cdot}hr$ exceeding about 5-times mean amount of outgoing pollutants over the West Sea. During the observed period, the amount of incoming and outgoing $SO_2$ over the Yellow Sea is the highest in winter, at 0.224 $ton/(km{\cdot}hr)$ and 0.120 $ton/(km{\cdot}hr)$, respectively.

The Analysis of Time Series of SO2 Concentration and the Control Factor in An Urban Area of Yongsan-gu, Seoul (서울시 용산구 지역에 이산화황 농도의 시계열 변동과 영향인자 분석)

  • Kim, Bo-Won;Kim, Ki-Hyun
    • Journal of the Korean earth science society
    • /
    • v.35 no.7
    • /
    • pp.543-553
    • /
    • 2014
  • The environmental behavior of $SO_2$ was investigated in terms of the factors affecting the temporal variabilities by analyzing the data sets obtained from the Yongsan district in Seoul from 2004 till 2013. To this end, the relationship between $SO_2$ and relevant parameters including particulate matters (such as $PM_{2.5}$, $PM_{10}$, and TSP (total suspended particulates)) and gaseous components ($CH_4$, CO, THC (total hydrocarbon), NMHC (non-methane hydrocarbon), NO, $NO_2$, NOx, and $O_3$) was investigated in several aspects. Over a decade, the annual mean concentrations of $SO_2$ varied in the range of $4.36-5.86nmole\;mole^{-1}$ (min-max) which was about five times lower than the regulation guideline set for the air quality management in Korea. In fact, this pattern greatly contrasts with some other air pollutants of which concentrations exceeded their guideline values significantly. According to our analysis, $SO_2$ was strongly correlated to the temperature and other relevant parameters. The overall results of this study confirm that the administrative regulation of $SO_2$ levels has been made effectively relative to other airborne pollutants.

Some Physical Properties and Adsoptive Behaviors of Wood Charcoal Carbonized with Domestic wood (국산수종으로 탄화한 목탄의 물성 및 흡착성)

  • Jo, Tae-Su;Lee, Oh-Kyu;Ahn, Byung-Jun;Choi, Joon-Weon
    • Journal of Korea Foresty Energy
    • /
    • v.25 no.1
    • /
    • pp.9-17
    • /
    • 2006
  • Properties of wood charcoal made from the domestic wood species at $300-900^{\circ}C$ have investigated to understand the correlation between carbonization temperature and chemical and physical characteristics of wood charcoal. In terms of charcoal yield at particular carbonization temperatures, it was drastically decreased until the temperature reaches up to $600^{\circ}C$ and the decrease ratio of yield was reduced at higher temperatures. As the carbonization temperature increased, pH of the wood charcoal increased so that it became basic at last. The wood charcoal prepared at $600{\sim}700^{\circ}C$ showed the highest caloric value and those of wood charcoals made at higher temperature became plateau at a little lower level than the peak. The caloric value of Japanese larch charcoal was a bit higher than that of Red oak charcoal. The carbon content in the wood charcoal was increased as the carbonization temperature increased, whereas the hydrogen content was decreased. Specific surface area of the wood charcoal became larger with increase in temperature up to $600^{\circ}C$ but it was decreased or reduced in the increasing ratio after, and then it rose again at higher temperature than $800^{\circ}C$. Absorption capacity of the wood charcoal against iodine and gaseous acetic acid became greater as the carbonization temperature increased. Japanese larch charcoal presented higher absorption capacity than Red oak charcoal. As the above results, it is revealed that carbonization temperature affects the chemical and physical properties of wood charcoal. Therefore, to use wood charcoal with maximum effect it should be prepared at optimum temperature for proper use.

  • PDF

A Study on the Characteristics of Waste Heat from the Industrial Complexes for Residential and Commercial Sectors (가정.상업부문 이용을 위한 산업체 폐열특성 연구)

  • 최영찬;박태준;홍재창;조선영
    • Journal of Energy Engineering
    • /
    • v.8 no.2
    • /
    • pp.242-247
    • /
    • 1999
  • The characteristics of waste heat effluents from 11 industrial complexes of 7 areas were analyzed to investigate the possibility of waste heat recovery of huge amount of waste heat producing from various industrial complexes. This study presents a part of the research work for the industrial waste heat for development of energy integrated network system in broad city area, which will utilize industrial waste heat for residential and commercial areas, where they are located at some distances from the complexes. The amount of waste heat from the investigated complexes was detected as 148,913 TOE/year. However, It was analyzed 83% of the waste heat was analyzed the temperature range from 0$^{\circ}C$ to 200$^{\circ}C$. Also, it was evaluated that 82% of waste heat was exhausted by flue gases. Especially, the characteristics of waste heat for the areas where most heat concentrated, such as Tae-gu industrial complex, Ul-san petrochemitry complex, Yio-chun petrochemistry complex, and Chun-ju industrial complex were investigated more precisely. Total amount of waste heat discharged from these four areas were analyzed 114,402 TOE/year, which was occupied as 77% of the total waste heat for the studied areas, and 87% of the waste heat from the industries was exhausted by flue gaseous phase and temperature range was from 0$^{\circ}C$ to 200$^{\circ}C$ 18.1 million TOE/year waste heat was released from the fossil fuel power plants, however 95% of waste heat was analyzed as cooling water from surface condensers at power plants. The temperature range was measured from 27$^{\circ}C$ to 34$^{\circ}C$, which are unable to utilize due to its low temperature. Otherwise, 5% (894,800 TOE/year) waste heat released from power plants were observed as flue gas, which temperature ranged from 90$^{\circ}C$ to 170$^{\circ}C$.

  • PDF

Effect of Acupuncture applied to Hand Yang Meridian on the Rat Model of Ankle Sprain Pain (수양경(手陽經) 경혈(經穴) 자침(刺鍼)이 백서(白鼠)의 족과 염좌(捻挫) 통증(痛症)에 미치는 영향(影響))

  • Kim, Il;An, Sung-Hun;Koo, Sung-Tae;Kim, Sun-Young;Kim, Kyung-Sik;Sohn, In-Chul
    • Korean Journal of Acupuncture
    • /
    • v.21 no.4
    • /
    • pp.69-82
    • /
    • 2004
  • Objectives : In the present study, the effect of electroacupuncture (EA) applied to hand yang meridian on the ankle sprain model was examined. Methods & Results : A common source of persistent pain in humans is the lateral ankle sprain. To model this condition, the rat's right ankle was bent repeatedly, overextending lateral ligaments, for 4 min under halothane anesthesia. The rat subsequently showed swelling of the ankle and a reduced stepping force of the affected limb for the next several days. The reduced stepping force of the limb was presumably due to a painful ankle. EA was applied to the several acupuncture point on the contralateral forelimb for 30 min under gaseous anesthesia. After the termination of EA, behavioral tests measuring stepping force were periodically conducted during the next 4 h. EA applied to SI-6 point produced a significant improvement of stepping force of the sprained foot lasting for at least 2 h. However, neigher LI-4 point nor TE-3 point produced any significant increase of weight bearing force. The improvement of stepping pressure was interpreted as an analgesic effect. The analgesic effect was specific to the acupuncture point since the analgesic effect on the ankle sprain pain model could not be mimicked by EA applied to a nearby point, LI-4 or TE-3. The analgesic effect of EA applied to SI-6 was more powerful when EA was applied by low-frequency and high-intensity stimulation. In addition, this effect need to be stimulated more than 15 min. Conclusions : These data suggest that EA produces a potent analgesic effect on the ankle sprain pain model in the rat. This analgesic effect is produced by applying EA to a Tae-Yang meridian at opposite side from the painful area in a stimulus point-specific way.

  • PDF

Earth Science Prospective Teachers' Perceptions on the Relationship between Absolute Humidity and Dew Point Temperature (절대 습도와 이슬점 온도의 관계에 대한 지구과학 예비 교사들의 인식)

  • Kang, So Ra;Seo, Eun-Kyoung;Kim, Dong Young
    • Journal of the Korean earth science society
    • /
    • v.40 no.6
    • /
    • pp.624-638
    • /
    • 2019
  • A questionnaire was administered, and all responses were analyzed to examine prospective teachers' conceptual understanding of the relationship between dew point temperature and absolute humidity in air parcels. The responses revealed that many prospective teachers have substantial misconceptions about the relationship. For example, some thought that the absolute humidity and the dew point temperature are proportional to each other, and that the dew point temperature is proportional to the water vapor mass in the parcel. The misconceptions seemingly stemmed from inadequate descriptions on the relationship in middle-school science textbooks of the 7th and 2007 revised curricula. The study notes that the first year students' textbook of the 2015 revised curriculum introduced the concepts of evaporation, condensation, and volume changes as a function of gaseous pressure and temperature, from a perspective of molecular motion. It is suggested that keeping this perspective in the middle school curriculum, while introducing water vapor pressure as the measure of water vapor amount and dew point temperature, should help prevent middle school teachers and students from having misconceptions. There should be a concerted effort to make the science curriculum more consistent and coherent across the grade levels.

Field Loss Analysis and Cooling Analysis of HTS Synchronous Motor (고온초전도 동기모터의 계자손실 해석 및 냉각 해석)

  • Kim, Ki-Chan;Lee, Dae-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.69-74
    • /
    • 2018
  • Large industrial motors require a large area because of the high risk of shutdown accidents and large industrial accidents due to the lowering of the dielectric strength of the armature windings and overheating problems. Therefore, there is a demand for a large-capacity motor that has small size, light weight, and excellent dielectric strength compared with conventional motors. Superconducting motors have advantages of high efficiency and output power, low size, low weight, and improved stability. This results from greatly increasing the magnetic field generation by using superconductive field coils in rotating machines such as generators and motors. It is very important to design and analyze the cooling system to lower the critical temperature of the wires to achieve superconducting performance. In this study, a field loss analysis and low-temperature heat transfer analysis of the cooling system were performed through the conceptual design of a 100-HP high-temperature superconducting synchronous motor. The field loss analysis shows that a uniform pore magnetic flux density appears when high-temperature superconducting wire is used. The low-temperature heat transfer analysis for gaseous neon and liquid neon showed that a flow rate of 1 kg/min of liquid neon is suitable for maintaining low-temperature stability of the high-temperature superconducting wire.

Recyling and refining of molybdenum scraps by vacuum arc melting (진공(眞空) 아크 용해(溶解)에 의한 몰리브덴 스크랩의 재활용(再活用) 및 정련(精鍊))

  • Lee, Back-Kyu;Oh, Jung-Min;Lee, Seoung-Won;Kim, Sang-Bae;Lim, Jae-Won
    • Resources Recycling
    • /
    • v.20 no.5
    • /
    • pp.40-45
    • /
    • 2011
  • We carried out to investigate the refining effect of molybdenum by Ar-H$_2$ vacuum arc melting(VAM) process for recycling Mo scrap. The purity of the Mo metals refined by VAM was evaluated using glow discharge mass spectromety(GDMS). From the result of GDMS, most impurities in the Mo metals except for W were removed by Ar-H$_2$ VAM down to a few mass ppm levels. The purity of the refined molybdenum scrap was improved up to 4N5(99.995%) from 3N(99.95%) of the initial Mo scrap. The amount of gaseous impurities such as C, N, and O in Mo scrap were decreased from 1290 ppm to 132 ppm. As a result, it is considered that a possibility of refining and cost-effective method for recycling Mo scrap by Ar-H$_2$ vacuum arc melting process was confirmed in this study.