• Title/Summary/Keyword: Gas scrubber

Search Result 136, Processing Time 0.029 seconds

Numerical Analysis for Breakup of Liquid Jet in Crossflow (기체 유동에 수직 분사된 액체의 분해에 대한 수치적 해석)

  • Park, Sun-Il;Chang, Keun-Shik;Moon, Yun-Wan;Sah, Jong-Youb
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1629-1633
    • /
    • 2004
  • Liquid is commonly introduced as transversal jets in venturi scrubber which is one of the gas cleaning equipments. The jet dynamics such as penetration and breakup is of fundamental importance to the dust-collection efficiency. We have developed a model that can numerically simulate the breakup of the liquid jet in crossflow. This simulation consists of models on liquid column, jet surface breakup, column fracture and secondary droplet breakup. These models have been embedded in the KIVA3-V code. We have calculated such parameters as the jet penetration, jet trajectory, droplet size, velocity field and the volume flux distribution. The results are compared with the experimental data in this paper.

  • PDF

Evaluation of high concentration carbon dioxide reduction efficiency using L-alanine·salt scrubber in Liquor factory (주류공정 내 L-alanine·염 스크러버를 이용한 고농도 이산화탄소 저감 효율 평가)

  • Kim, Heung-Rae;Lee, June-Hyung;Park, Hyung-June;Park, Ki-Tae;Park, Il-Gun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.214-223
    • /
    • 2020
  • This study evaluated CO2 removal efficiency, monitoring data analysis / evaluation efficiency and energy reduction efficiency in the liquor factory by L-alanine applied scrubber. The average removal rate of the scrubber was 90.45%, and it was confirmed that the removal efficiency was excellent above 10,000ppm of inlet CO2 concentration. After the scrubber operation, the CO2 concentration in the workplace was maintained under 2,000ppm(the carbon dioxide reduction efficiency was about 74%). and the energy saving efficiency was calculated to 7.26% by reducing the power consumption. As a result of applying the developed product, it was possible to improve the working environment of workers by reducing the carbon dioxide concentration in the workplace at low concentration without ventilation, and to reduce the energy consumption. Therefore, it is expected that the scrubber will be useful as a high CO2 removal process in food and liquor factories.

Changes in Mineral and Pectic Substances of Korean Mature-Green Mume (Prunus mume Sieb. et Zucc) Fruits Packaged in Plastic Films with Gas Absorbents during Storage (가스 제거제 첨가에 따른 필름 포장 청매실의 저장 중 무기질 및 펙틴 성분 변화)

  • Cha, Hwan-Soo;Hong, Seok-In;Chung, Myong-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.1
    • /
    • pp.149-154
    • /
    • 2003
  • Changes in mineral (Ca, Mg) contents and pectic substances of mature-green 'Nanko' Mume fruits hermetically packaged in 0.03 mm low density polyethylene (LDPE) films with and without gas absorbents were examined during storage at $25^{\circ}C$ for 10 days. Each packaging contained 10 g $Ca(OH)_2$ as a carbon dioxide scavenger, 30 g $KMnO_4$ as an ethylene scrubber or their mixture. In the presence of the ethylene scrubber, losses in mineral contents of alcohol insoluble solids and water soluble pectin were remarkably suppressed, whereas no significant difference was observed in the Ca content between the fresh fruit and those stored for 10 days. Fruits packaged with the ethylene absorbent retained higher amount of pectic substances than those with other packaging treatments. Degradation of the pectic substances into small molecules was also noticeably reduced when the ethylene scrubber was used. Overall results showed that the combination of the gas permeable film and the ethylene absorbent could be applied to mature-green Mume fruits as an effective packaging method to retard the texture softening during storage at the ambient temperature.

A Study on the Destruction or Removal Efficiency of Toxic Gas Reduction Facilities in Semiconductor and Display Industries (반도체 & 디스플레이 업종에서 사용되는 독성가스 저감시설의 처리효율 측정방법에 관한 연구)

  • Jang, Sung-Su;Han, Jae-Kook;Cho, Hyun-Il;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.6
    • /
    • pp.88-95
    • /
    • 2017
  • The usage of toxic gas in Korea is increasing in the development of high-tech industries such as semiconductors, displays and solar panels. The recent survey of domestic toxic gas consumption indicates an increase in annual average of 12.4 percent, but it is still focused on usage, and it is negligent in safety and treating the post. In September 2012, an accident occurred in Gu-mi involving hydrofluoric acid leak demonstrates the absence of safety management. Due to the incident, the government, industry and academia have been interested in chemical substances(toxic gas), and the government-led safety management has been established and implemented, but there are still a lot of safety blind spots. The purpose of this study is to develop effective measurement methods for the destruction or removal efficiency of gaseous materials emitted from the Scrubber used in the semiconductor and display industries. Also, this study demonstrated how toxic gas facilities can be applied without error by verification test for the measurement method guideline of the destruction or removal efficiency of the green-house gas reduction facility in the semiconductor and display industries used by the National Institute of Environmental Research and the UNFCCC, and suggested the differentiated measurement methods for toxic gas reduction facilities, and the third party certification for safety facilities is needed to prevent toxic gas accidents.

Construction of Greenhouse Gas Inventory of Private Industry of Chungcheongbuk-do and Analysis of Greenhouse Gas Mitigation Technology (충청북도 민간 산업체에 대한 온실가스 인벤토리 구축 및 감축기술 분석)

  • Lim, Soo Min;Ahn, Joo Young;Jung, Cho Shi;Park, Jung Hoon
    • Journal of Climate Change Research
    • /
    • v.8 no.1
    • /
    • pp.57-62
    • /
    • 2017
  • Greenhouse gas (GHG) emissions of private industry of Chungcheongbuk-do were estimated. GHG emissions were classified by industry and GHG emissions ratio of each industry of Chungcheongbuk-do was found. Characteristics of GHG emissions of Chungcheongbuk-do and GHG mitigation technology were analyzed. To calculate GHG emissions, equations proposed through GHG emissions calculation guidelines published by Korean Energy Agency in 2009 were used. As a result, GHG emissions ratio of cement, semiconductor, paper and petrochemical industry was about 73%, 16%, 5%, and 2% respectively. GHG mitigation technologies of cement, semiconductor and waste were investigated. For cement, amine technology, for semiconductor, scrubber system and for waste, land fill gas utilization were analyzed.

Development of Vortex Scrubber Using Electrolyzed Water for the Removal Efficiency Improvement of Minute Particles and Odor (미세분진 및 냄새제거 효율향상을 위한 선회류식 세정전해 기술개발)

  • Kim, Nor-Jung;Lim, Seong-Il;Kim, Sun-Mi;Kim, Sun-Uk;Kim, Lae-Hyun;Kim, Sun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.3
    • /
    • pp.1-7
    • /
    • 2010
  • According to Indoor Air Quality(IAQ) management law for multi-use buildings, SEEONE CO., Ltd. made pilot and tested it to remove minute particle, odor, VOCs, etc. within the standards of IAQ. This pilot made by SEEONE CO., Ltd. is vortex scrubber washing electrolyzed water. As 30 minutes test result in multi-use building indoor place, minute particle(the smoke of a cigarette) was reduced $920{\mu}g/m^3{\rightarrow}112{\mu}g/m^3$, gaseous contaminants was reduced Formaldehyde (HCHO) 20ppm$\rightarrow$4ppm, Ammonia($NH_3$) 50ppm$\rightarrow$1ppm, Trimethylamine ($(CH_3CH_2)_3N$) 15ppm$\rightarrow$trace, Methylethylketone($CH_3COC_2H_5$) 25ppm$\rightarrow$trace, Acetic acid ($CH_3COOH$) 20ppm$\rightarrow$trace, Acetaldehyde($CH_3CHO$) 15ppm$\rightarrow$2ppm and Acetone($CH_3COCH_3$) 50ppm$\rightarrow$N.D. The pilot test result of the air filter using electroyzed water in vortex scrubber showed high removal efficiency. Because purified air maintain indoor humidity of approximately 40~60%, so users can feel pleasant. In E.coli, S.aureus sterilization test and CODcr, turbidity treatment test by electrolysis, germs was sterilized over 99.99% and CODcr and turbidity was decreased gradually. So water used for washing can be reused by electrolysis.

Studies on syngas production and gas engine generation of soild waste gasification in the fixed bed gasification melting furnace (고정층 가스화 용융로에서의 고상폐기물 가스화 합성가스 생산 및 가스엔진 발전 연구)

  • Gu, Jae-Hoi;Kim, Su-Hyun;Yoo, Young-Don;Yun, Yong-Seung;Lee, Hyup-Hee;Nam, Sang-Ik;Yoon, Jae-Kwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.717-720
    • /
    • 2007
  • The 3 ton/day-scale pilot plant consists of compressor, feed channel, fixed bed type gasification & melting furnace, quench scrubber, demister, flare stack and gas engine. Syngas composition of gasification using the 35.50(waste I), 4.34%(wasteII) moisture-containing solid waste showed waste I CO 25-35%, 20-40% hydrogen, waste II 25-35%, 20-30% hydrogen. Gasification melting furnace was operated $1,500{\sim}1,600^{\cdot}C$. Gas engine was generated $35{\sim}40$ kW as waste gasification syngas.

  • PDF

Air Pollution Protection onboard by Seawater and Electrolyte

  • An Suk-Heon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.93-101
    • /
    • 2006
  • This research makes a new attempt to apply the activated seawater by electrolysis in the development of two-stage wet scrubber system to control the exhaust gas of large marine diesel engines. First, with using only seawater that is naturally alkaline (pH typically around 8.1). the $SO_2\;and\;SO_3$ are absorbed by relatively high solubility compared to other components of exhaust pollutants, and PM (Particulate Matter) is removed through direct contact with sprayed seawater droplets. Besides, the electrolyzed alkaline seawater by electrolysis, which contains mainly NaOH together with alkali metal ions $(i.e.\;Na^+,\;Mg^{2+},\;Ca^{2+})$, is used as the absorption medium of NOx and $CO_2$. Especially, to increase NOx absorption rate into the alkaline seawater. nitric oxide (NO) is adequately oxidized to nitrogen dioxide $(NO_2)$ in the acidic seawater, which means both volume fractions are adjusted to identical proportion. The results found that the strong acidic seawater was a valid oxidizer from NO to $NO_2$ and the strong alkaline seawater was effective in $CO_2$ absorption In the scrubber test, the SOx reduction of nearly $100\%$ could be achieved and also led to a sufficientPM reduction. Hence, the author believes that applying seawater and its electrolyte would bring the marine air pollution control system to an economical measure. Additionally it is well known that NOx and SOx concentration has a considerable influence on the $N_2O$ emission of green house gas. Although the $N_2O$ concentration exhausted from diesel engines is not as high, the green house gas effect is around 300 times greater than an equivalent volume of $CO_2$. Therefore, we investigated the $N_2O$ removal efficiency with using the electrolyzed seawater too. Finally this research would also plan to treat the effluent by applying electro-dialysis and electro-flotation technique s in the future.

Application of an In-situ Measurement System to Determine HONO Levels in an Indoor Environment (실시 측정시스템을 활용한 실내 환경에서 HONO 농도 조사)

  • Hong, Jin-Hee;Lee, Jai-Hoon;Park, Seung-Shik
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.2
    • /
    • pp.191-202
    • /
    • 2007
  • We developed an in-situ analyzer to understand the HONO levels in indoor environments. The in-situ measurement system utilizes a diffusion scrubber and luminol chemiluminescence to measure the HONO concentration with time resolution of 4-minute. Concentrations of NO, $NO_{2}$, and HONO were determined at an indoor air of an apartment for 9 days using the developed in-situ analyzer. Indoor HONO concentrations were highly elevated when a gas range was operated. Enhancements of the indoor NO, $NO_{2}$, and HONO concentrations during combustion indicate that the observed indoor HONO was formed by direct emission. In addition to the direct emission, the indoor HONO was partially generated from heterogeneous reactions of $NO_{2}$ on indoor surfaces, which was supported by strong relationships between peak NO, $NO_{2}$, and HONO concentrations, high HONO/$NO_{2}$ ratio and a weak correlation between NO and HONO concentrations. Additionally, three combustion experiments during the whole measurement period were performed to investigate the effects of unvented and vented gas burning on the HONO, NO, and $NO_{2}$ concentrations and their decay. The decay rate of the HONO concentration was significantly less than the NO and $NO_{2}$ decay rates for all the experiments, indicating that the lifetimes of trace nitrogen species in indoor environment varied in the order approximately HONO>$NO_{2}$>NO.

Experiments for Pressure Drop of Scrubbing Layer in a Scrubber System (스크러버 내 충진층에서의 압력강하 특성에 관한 실험적 연구)

  • Yong-Shik Han;Kyu Hyung Do;Kyungyul Chung;Byungil Choi;Hwalong You;Changhyun Kim;Minchang Kim;Taehoon Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.3
    • /
    • pp.186-192
    • /
    • 2023
  • According to the regulation on the pollution of the marine environment, SOx emission from ships has to be reduced. A SOx scrubbing system installed in a funnel of a ship is considered in order to reduce SOx emission. A scrubbing layer with a porous material is present in the funnel to increase the contact area between exhaust gas and water. In this study, experiments on the pressure drop characteristics in the scrubbing layer are conducted to investigate the effect of the scrubber on the engine load. The pressure drop according to flow rate of air instead of exhaust gas was measured for fillers such as sphere, pall ring and saddle in the scrubbing layer. First of all, porosity is experimentally measured for the three types of filler and it is confirmed that the porosity of the saddle-type filler was the largest. The pressure drop according to the change in air flow rate was measured for the three types of fillers in the scrubbing layer. As a result, the pressure drop was the smallest in the scrubbing layer with the saddle-type filler which has the largest porosity. In addition, the effect of spraying water flowing counter flow against air flow is experimentally examined. It is known that the pressure drop is increased because the air flow space is reduced when water is sprayed. In the case of the saddle, the pressure drop is about 1.5 to 2 times greater than that when only air flows at the optimum exhaust gas-water injection ratio.