• Title/Summary/Keyword: Gas permeation.

Search Result 382, Processing Time 0.025 seconds

A Study on the Gas Permeation Characteristics of Plasma Polymers (플라즈마 고분자에 대한 기체의 투과특성에 관한 연구)

  • Oh, Sae-Joong
    • Membrane Journal
    • /
    • v.4 no.4
    • /
    • pp.205-212
    • /
    • 1994
  • Gas permeation properties of simple gases(He, $H_2,\;CO_2,\;O_2,\;N_2,\;CH_4$) through plasma-polymerized films were investigated, and the chemical structure of the plasma polymers was analyzed by infrared spectra. The plasma-polymerized films were prepared by plasma polymerization of fluorine-containing aromatic compounds, and permeation measurements were made at $35^{\circ}C$, latm. The permeability coefficient of the plasma films decreased as the size of penetrant molecules increased. The plasma polymers showed higher $CO_2/CH_4$ selectivities than those of commonly used polymers, while $O_2/N_2$ selectivities were similar of slightly lower than those of common polymers. FT-IR spectra shows that the plasma polymers contain both aromatic and aliphatic structures.

  • PDF

GAS PERMEATION THROUGH GLASSY POLYMER MEMBRANES WITH HIGH GLASS-TRANSITION TEMPERATURE

  • Kumazawa, Hidehiro
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1993.10a
    • /
    • pp.13-20
    • /
    • 1993
  • The sorption equilibria and permeation rates for carbon dioxide in such glassy polymer membranes with high glass-transition temperature as polyimide, polyetherimide, polysulfone and polyethersulfone membranes, were measured. The sorption isotherms for these systems can be described well by the dual-mode sorption model, whereas the pressure dependences of the mean permeability coefficients are simulated better by a modified dual-mode mobility model than the conventional dual-mode mobility model in which the Henry's law and Langmuir populations execute four kinds of diffusive movement.

  • PDF

Gas permeation property of organic-inorganic hybrid membrane made by ion-beam irradiation

  • Kawakami, Hiroyoshi
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.90-93
    • /
    • 2004
  • In this study, we have reported an organic-inorganic hybrid membrane, which exhibits an asymmetric structure consisted of a carbonized skin layer and a polyimide porous substructure, to synthesize a novel gas separation membrane combining high gas permeability and selectivity. Both the gas permeability and selectivity of the carbonized layer significantly enhanced when compared with those determined in the control polyimide.

  • PDF

Carbon Molecular Sieve Membranes Dispersed with Nano Particles

  • H.Suda;Ha, K.raya
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.183-186
    • /
    • 2004
  • Nano particles-containing CMS membranes were prepared by pyrolysis of polyimides dispersed uniformly with precursors and their gas separation performances were examined, to elucidate the permeation mechanism and to further improve the gas separation performance. Consequently, it was suggested that the separation performance could be controlled by doping nano-particles in the CMS membranes, and that optimization of various factors, such as the size, content, and dispersion state of the nano particles would contribute for further improvement of the gas separation performance.

  • PDF

Gas Permeation Characteristics of the Prepared SiC Membrane through Polyimide Carbonization Treatmemt (폴리이미드의 탄화 처리에 의한 SiC 분리막의 가스투과 특성)

  • Choi, Ho-Sang;Hwang, Gab-Jin;Kang, An-Soo
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.66-70
    • /
    • 2005
  • For the application in HI decomposition reaction of thermochemical water-splitting IS process, the carbonized membranes using the polymer material (polyimide) were prepared, and SiC membrane was also prepared by SiO treatment on those carbonized membranes. The weight change by the carbonation of polyimide was about 50%, and the weight decreased with an increase of carbonation temperature. The gas permeance ($H_2$ or $N_2$) of carbonized membrane decreased with an increase of carbonation temperature led to the pore closing. The gas permeance ($H_2$ or $N_2$) of SiC membrane increased with an increase of SiO treatment concentration, and the gas permeation mechanism was changed from the activiation energy flow to Knudsen flow.

Effect of Non-ionic Additive on Morphology and Gas Permeation Properties of Polysulfone Hollow Fiber Membrane (비이온계 첨가제에 의한 폴리술폰계 중공사 막의 모폴로지 조절과 기체투과 특성)

  • Lee, Hye Jin;Koh, Mi Jin;Kim, Duek Ju;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.22 no.3
    • /
    • pp.224-233
    • /
    • 2012
  • To improve permeation performance of gas separation membrane, polysulfone hollow fiber membrane was prepared by wet-dry phase inversion method using Triton X-100 as non-ionic additive. And variation of gas permeation behavior by additive was investigated. Various spinning conditions such as air gap, concentration of polymer, dope tank temperature were controlled and these effects were studied. The morphology and gas permeation property of hollow fiber membranes were investigated using scanning electron microscope (SEM) and bubble flow meter respectively. We confirmed that the membranes added with Triton X-100 had a smooth external skin at various air gap length conditions. The macrovoids of these hollow fiber membranes were more developed with increase of air-gap from 4 to 90 cm and that induced higher permeance. The permeance of polysulfone membranes has the higher value at comparatively lower concentration polymer (30 wt% polysulfone) and lower concentration of additive (15 wt% Triton X-100). When temperature in dope tank was controlled, the membranes prepared at $100^{\circ}C$ showed low permeance because of volatilization of additive and solvent.

Evaluation of Pore Size of Porous Support using Modified Gas Permeation Method (수정된 기체투과법을 이용한 다공성 지지체의 기공크기 평가)

  • 박재구;김현중
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.6
    • /
    • pp.568-574
    • /
    • 2001
  • 수정된 기체투과법을 이용하여 다공성 지지체의 기공크기를 평가하였다. 본 연구에서의 수정된 기체투과법은 기공 내에서 유체흐름이 Hagen-Poiseiulle 법칙이 성립하는 영역으로 압력을 조절하여 투과유량을 측정하는 방법을 말한다. 수정된 기체투과법의 적합성 여부는 유체의 Reynolds number 및 기체분자의 평균자유행로를 통해 검토하였다. 다공성 지지체의 유량의 시간변화로부터 대표치를 결정하여 기공크기로 환산하였다. 본 방법에 의해 평가된 다공성 지지체의 기공크기는 30$\mu\textrm{m}$~80$\mu\textrm{m}$ 이었으며, 평균치는 50$\mu\textrm{m}$로 평가되었다. 한편 화상해석법과 비교.분석한 결과 수정된 기체투과법을 통해 평가된 기공은 내부채널의 가장 작은 부분을 나타내는 것으로 확인되었다.

  • PDF

Preparation and Permeation Characteristics of Alumina Composite Membranes by CVD and Evaporation-Oxidation Process (화학증착 및 증발-산화법에 의한 알루미나 복합분리막의 제조 및 투과특성)

  • 안상옥;최두진;현상훈;정형진;유광수
    • Journal of the Korean Ceramic Society
    • /
    • v.30 no.8
    • /
    • pp.678-684
    • /
    • 1993
  • Alumina composite membranes were prepared by chemical vapor deposition and evaporation-oxidation process. For CVD process, deposition was carried out using aluminum-tri-isopropoxide at 35$0^{\circ}C$, 2 torr by heterogeneous reaction, and for evaporation-oxidation process, alumina composite membranes were prepared by evaporation of aluminum and dry oxidation at 80$0^{\circ}C$. As deposition time increases, water flux and N2 gas permeability of the composite membranes prepared by both processes were reduced. Applying gas permeation model, permeability and cracking possibility of top layer were evaluated.

  • PDF

Gas Permeabilities of Plasma Polymerized Films : Temperature Dependence Study (플라즈마 고분자 필름의 기체투과도 : 온도의존성에 관한 연구)

  • 김학수;오세중
    • Membrane Journal
    • /
    • v.7 no.4
    • /
    • pp.183-190
    • /
    • 1997
  • Composite membranes were prepared by the deposition of pentafluoropyridine(PFP) or pentafluorotoluene(PFT) plasma films onto porous Celgard and nonporous poly(dimethylsiloxane) [PDMS] films. Gas permeation measurements for the composite membranes were made in the temperature range of 35$^{\circ}$C to 75 $^{\circ}$C and the solubilities in plasma polymers were measured using a Cahn Microbalance. The permeability coefficients of plasma polymers obeyed the Arrhenius relationship fairly wall. Activation energies for permeation in the plasma films increased with the size of penetrant molecules. The activation energy of plasma polymers was much lower than that of commonly used perfluoropolymers. This difference was proved to be attributable to the much lower heat of solutions of the plasma polymers compared to perfluoropolymers. The diffusion activation energies were comparable with each other.

  • PDF

Separation Permeation Characteristics of N2-O2 Gas in Air at Cell Membrane Model of Skin which Irradiated by High Energy Electron (고에너지 전자선을 조사한 피부의 세포막모델에서 공기 중의 O2-N2 혼합기체의 분리투과 특성)

  • Ko, In-Ho;Yeo, Jin-Dong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.261-270
    • /
    • 2019
  • The separation permeation characteristics of $N_2-O_2$ gas in air at cell membrane model of skin which irradiated by high energy electron(linac 6 MeV) were investigated. The cell membrane model of skin used in this experiment was a sulfonated polydimethyl siloxane(PDMS) non-porous membrane. The pressure range of $N_2$ and $O_2$ gas were appeared from $1kg_f/cm^2$ to $6kg_f/cm^2$. In this experiment(temperature $36.5^{\circ}C$), the permeation change of $N_2$ and $O_2$ gas in non-porous membrane by non-irradiation were found to be $1.19{\times}10^{-4}-2.43{\times}10^{-4}$, $1.72{\times}10^{-4}-2.6{\times}10^{-4}cm^3(STP)/cm^2{\cdot}sec{\cdot}cmHg$, respectively. That of $N_2$ and $O_2$ gas in non-porous membrane by irradiation were found to be $0.19{\times}10^{-4}-0.56{\times}10^{-4}$, $0.41{\times}10^{-4}-0.76{\times}10^{-4}cm^3(STP)/cm^2{\cdot}sec{\cdot}cmHg$, respectively. The irradiated membrane was significantly decreased about 4-10 times than membrane which was not irradiated. And ideal separation factor of $N_2$ and $O_2$ gas by non-irradiation was found to be from 1.32 to 0.42 and that of $N_2$ and $O_2$ gas by irradiation was found to be from 0.237 to 0.125. The irradiated membrane was significantly decreased about 4-5 times than membrane which was not irradiated. When the operation change(cut) and pressure ratio(Pr) by non-irradiation were about 0, One was increased to the oxygen enrichment and the other was decreased to the oxygen enrichment. The irradiated membrane was significantly decreased about 4-19 times than membrane which was not irradiated. As the pressure of $N_2$ and $O_2$ gas was increased, the selectivity was decreased. As separation permeation characteristics of $N_2-O_2$ gas in cell membrane model of skin were abnormal, cell damages were appeared at cell.