• Title/Summary/Keyword: Gas path

Search Result 318, Processing Time 0.022 seconds

Application of DFB Diode Laser Sensor to Reacting Flow (II) - Liquid-Gas 2-Phase Reacting Flow -

  • Park, Gyung-Min;Masashi Katsuki;Kim, Duck-Jool
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.139-145
    • /
    • 2003
  • Diode laser sensor is conducted to measure the gas temperature in the liquid-gas 2-phase counter flow flame. C$\_$10/H/ sub 22/ and city gas were used as liquid fuel and gas fuel, respectively. Two vibrational overtones of H$_2$O were selected and measurements were carried out in the spray flame region stabilized the above gaseous premixed flame. The path-averaged temperature measurement using diode laser absorption method succeeded in the liquid fuel combustion environment regardless of droplets of wide range diameter. The path-averaged temperature measured in the post flame of liquid-gas 2-phase counter flow flame showed qualitative reliable results. The successful demonstration of time series temperature measurement in the liquid-gas 2-phase counter flow flame gave us motivation of trying to establish the effective control system in practical combustion system. These results demonstrated the ability of real-time feedback from combustor inside using the non-intrusive measurement as well as the possibility of application to practical combustion system. Failure case due to influence of spray flame was also discussed.

Fluid Dynamics Analysis and Experimental Trial to Improve the Switching Performance of Eco-friendly Gas Insulated Switch (친환경 가스개폐기 개폐성능 향상을 위한 유동해석 및 실험)

  • Yu, Lyun;Ahn, Kil-Young;Kim, Young-Geun;Cho, Hae-Yong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.9
    • /
    • pp.42-49
    • /
    • 2022
  • An underground electric switch is a high-voltage switch used in distribution network systems for a reliable power supply. Many studies are being conducted to expand the switch to use an eco-friendly gas using dry air instead of SF6 gas to reduce greenhouse gas emissions. In this study, a flow analysis model was established to improve the performance of an eco-friendly gas switch. The results were compared and reviewed through experiments. For the optimal arc grid design applied to the switch, the flow characteristics based on the flow path configuration and the changes in arcing time for each configuration were compared. Flow analysis can predict the switch flow distribution, and a comparative review of the flow path configurations of various methods is possible.

Transmission Path Analysis of Noise and Vibration in a Rotary Compressor by Statistical Energy Analysis

  • Hwang, Seon-Woong;Jeong, Weui-Bong;Yoo, Wan-Suk;Kim, Kyu-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.11
    • /
    • pp.1909-1915
    • /
    • 2004
  • The hermetic rotary compressor is one of the most important components of an air conditioning system since it has a great effect on both the performance and the noise and vibration of the system. Noise and vibration occurs due to gas pulsation during the compression process and to unbalanced dynamic force. In order to reduce noise and vibration, it is necessary to identify their sources and transmission path and effectively control them. Many approaches have been tried in order to identify the noise transmission path of a compressor. However, identification has proven to be difficult since the characteristics of compressor noise are complicated due to the interaction of the compressor parts and gas pulsation. In this study, the statistical energy analysis has been used to trace the energy flow in the compressor and to identify the transmission paths from the noise source to the exterior sound field.

The improvement method for power plant boiler temperature nonuniformity of heat transfer tube bank flow path (발전용 보일러 전열 튜브 유로내 온도분포 불균일 개선기법)

  • Jung, Hoon;Kim, Bum-Shin;Jang, Suck-Won;Ahn, Yeon-Shik;Park, Gun-Bok;Whang, Jung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.837-841
    • /
    • 2001
  • Almost all power plant boiler has temperature distribution nonuniformity problem in heat transfer tube flow path. It can cause hot spot damage of superheated or reheated heat transfer section and reduce maintenance schedule when nonuniformity is severe. There are two solutions for improvement temperature nonuniformity. one is change of gas flow distribution of gas path and the other is contorl steam flow in tube bank. Of course, first method is very difficulty to apply but second method is'nt. In this paper, control steam flow is used to solve temperature nonuniformity of power plant boiler.

  • PDF

A Study on Remote Analysis of Fire Gas Using Open Path FT-IR (개방형 적외선분석기를 사용한 원거리 화재발생가스 측정에 관한 연구)

  • Cho, Nam-Wook;Lee, In-Gu;Lee, Jong-Cheon
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.39-45
    • /
    • 2013
  • The gas generated from the fire which is continuous until material is completely burned. We can analyze usual gas using chromatography analysis but it can not be applicated to analyze for the gas from the fire because which gas is enormously generated. Besides, chromatography analysis has the disadvantage that it can not continuously analyze the sample's representativness, gas from the fire, Fourier transform infrared spectroscopy, FT-IR, has been utilized for effective combustion gas analysis method in small-scale combustion and on-line analysis has been attempted continuously. However, continuous sampling of 3.5l/min can not be representativness of sample if the gas caused by a massive fire and space. And the gas sampling is practically impossible in such a case. In this study, we attempted remote analysis while overcoming the disadvantages of the current gas analysis by using an Open-Path Infrared Analyzer without pre-treatment of the sampling. For the remote analysis, quantitative analysis method was established regarding each combustion toxic gases. And we measured the gases from the fire that occurs in the real case.

Study on Acquisition Method for GAS-CP-CDMA (Cyclic-Prefix Code Division Multiple Access using Good-Autocorrelation-Sequence) (GAS-CP-CDMA 동기 포착 방법 연구)

  • Lee, Seong-Min;Kim, Young-Je;Kim, Whan-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.11A
    • /
    • pp.1087-1094
    • /
    • 2008
  • In this paper, we propose the acquisition method of the Cyclic-Prefix CDMA using Good-Autocorrelation-Sequence (GAS-CP-CDMA) system. The sequences for GAS-CP-CDMA are m-sequence and constant amplitude zero autocorrelation code (CAZAC) with good autocorrelation property. The GAS-CP-CDMA system is proposed for interference cancellation in multi-user and -path environment in co-cell. However, the reliable initial acquisition in multi-path fading channel and multi-user system environment is crucial. In this paper, non-coherent power detector and threshold value are used for discriminating signal acquisition. The sequence used for computer simulation is CAZAC. The simulation results show proper threshold value depends on the number of users. Through the computer simulation, we draw setting up method of the optimum threshold value for the GAS-CP-CDMA system.

Percolation Approach to the Morphology of Rigid-Flexible Block Copolymer on Gas Permeability

  • 박호범;하성룡;이영무
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.69-70
    • /
    • 1997
  • Polyimides and related polymers, when synthesized from aromatic monomers, have generally rigid chain structures resulting in a low gas permeability. The rigidity of polymer chains reduces the segmental motion of chains and works as a good barrier against gas transport. To overcome the limit of use as materials of gas separation membranes due to low gas permeability, block copolymers with the incorporation of flexible segments like siloxane linkage and ether linkage have been studied. These block copolymers have microphase-separated structures composed of microdomains of flexible poly(dimethylsiloxane) or polyether segments and of rigid polyimides segments. In case of rigid-flexible block copolymers, the characteristics of both phases for gas permeation are of great difference. The permeation of gas molecules occurs favorably through microdomains of flexible segments, whereas those of rigid segments hinder the permeation of gas molecules. Accordingly the increase of content of flexible segments in a rigid polymer matrix will increase the gas permeability of the membrane linearly. However, this prediction does not satisfy enough many experimental results and in particular the drastic increase of the permeability is observed in a certain volume fraction. It was proposed that the gas transport mechanism is dominated by diffusion rather than gas solubility in a certain content of flexible phase if solution-diffusion mechanism is adopted. However, the transition from solubility-dependent to diffusion-dependent cannot be explained by the understanding of mechanism itself. Therefore, we consider an effective chemical path which permeable phase can form in a microheterogenous medium, and percolation concept is introduced to describe the permeability transition at near threshold where for the first time a percolation path occurs. The volume fraction of both phases is defined as V$_{\alpha}$ and V$_{\beta}$ in block copolymers, and the volume of $\beta$ phase in the threshold forming geometrically a traversing channel is defined as V$_{\betac}$. The formation mechanism of shortest chemical channel is schematically depicted in Fig. 1.

  • PDF

A Development of EMAS (Easy Maintenance Assistance Solution) for Industrial Gas Turbine (산업용 가스터빈을 위한 정비지원 시스템 개발에 관한 연구)

  • Kang, Myoungcheol;Ki, Jayoung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.3
    • /
    • pp.91-100
    • /
    • 2017
  • The solution was developed for the maintenance decision support of combined cycle power plant gas turbine. The developed solution was applied to MHI501G gas turbine and is, in present, on the process of field test at GUNSAN combined cycle power plant, South Korea. The developed solution provides the calculated result of optimal overhaul maintenance period through following modules: Real Time Performance Monitoring, Model-Based Diagnostics, Performance Trend Analysis, Optimal Overhaul Maintenance Interval, Compressor Washing Period Management, and Blade Path Temperature Analysis. Model-Based Diagnostics module analyzed the differences between the data of gas turbine performance model and the online measurement. Compressor washing management module suggests the optimal point of balancing between the compressor performance and the maintenance cost.

Atmospheric Pressure Plasma Research Activity in Korea

  • Uhm, Han S.
    • Journal of the Korean institute of surface engineering
    • /
    • v.34 no.5
    • /
    • pp.367-377
    • /
    • 2001
  • Plasma is generated by electrical discharge. Most plasma generation has been carried out at low-pressure gas typically less than one millionth of atmospheric pressure. Plasmas are in general generated from impact ionization of neutral gas molecules by accelerated electrons. The energy gain of electrons accelerated in an electrical field is proportional to the mean free path. Electrons gain more energy at low-pressure gas and generate plasma easily by ionization of neutrals, because the mean free path is longer. For this reason conventional plasma generation is carried out at low pressures. However, many practical applications require plasmas at high-pressure. In order to avoid the requirement for vacuum pumps, researchers in Korea start to develop plasmas in high-pressure chambers where the pressure is 1 atmosphere or greater. Material processing, environmental protection/restoration and improved energy production efficiency using plasmas are only possible for inexpensive bulk plasmas. We thus generate plasmas by new methods and plan to set foundations for new plasma technologies for $21^{st}$ / century industries. This technological research will play a central role in material processing, environmental and energy production industries.

  • PDF

FEM/BEM Modeling of the Top Cap of Scroll Compressors for Analysis of Noise Radiation (스크롤 압축기 상부 캡의 방사 소음 해석을 위한 유한 요소/경계 요소 모델링)

  • Ahn, Jae-Hong;Song, Jae-Soo;Kim, Sung-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.346-350
    • /
    • 2000
  • In scroll compressors, there are two major noise sources. Sturctural path: excitation of the compressor housing by unbalance forces and forces generated by compression cycle. Gas cavity path: excitation of top cap by discharge gas pulsation. In this study, in order to analyze the radiated noise generated by the discharge gas pulsation, FEM/BEM model of the top cap is established. Measured pressure of discharge pulsation is introduced in the FEM model as the excitation and vibration response is calculated. Radiated sound pressure is then obtained by BEM method based on this vibration response. Results are compared with the measured data. It is shown that the trend of the noise radiation can be predicted in this approadch.

  • PDF