• 제목/요약/키워드: Gas loop

검색결과 232건 처리시간 0.024초

내부순환반응기의 Scale-up에 따른 동력학적 특성의 변화 (Dynamic Behavior of an Internal Loop Reactor during Scale-up)

  • 최윤찬;박영식
    • 한국환경과학회지
    • /
    • 제6권1호
    • /
    • pp.25-31
    • /
    • 1997
  • The variations of gas hold-up, overall volumetric oxygen mass transfer coefficients and liquid circulation velocity in an internal loop reactor were investigated to manifest scale-up effect. The relationship between superficial gas velocity and gas hold-up were found as Ugr = 0.045 $\varepsilon$r in the pilot-scale and Ugr = 0.056 $\varepsilon$r in the bench-scale reactor. The overall volumetric oxygen mass tractsfer coefficient, KLa was slightly increased in the pilot-scale than in the bench-scale reactor. Flow regime was changed from the bubble flow to the churn-turbulent flow when the superficial gas velocity reached to 3.5 - 4 cm/sec in the pilot-scale.

  • PDF

터보펌프+가스발생기 폐회로 연계시험 특성 연구 (Study on the Characteristics of Turbopump+Gas generator Closed-loop coupled test)

  • 김승한;남창호;김철웅;설우석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.38-41
    • /
    • 2009
  • 액체산소/케로신 추진제 액체로켓엔진 개발기술 확보를 위해, 연소기를 제외한 터보펌프, 가스발생기 등의 30톤급 엔진 주요 구성품을 이용한 터보펌프+가스발생기 폐회로 연계시험을 수행하였다. 연소기를 유량제어 요소로 모사한, 엔진시스템 모사조건에서 터보펌프+가스발생기 폐회로 연계시험기의 예냉 절차, 시동 특성, 정격조건 작동 및 정지가 성공적으로 수행되었다. 터보펌프와 가스발생기의 작동성을 검증하였다. 연계시험기의 터보펌프 회전수 및 혼합비 피드백 제어를 위한 제어시스템도 검증되었다. 본 폐회로 연계시험 결과는 액체로켓엔진 선행 기술 개발에 활용될 것이다.

  • PDF

터보펌프 조립체-가스발생기 연계 개회로 시험에서의 시동특성 분석 (Analysis of Startup Characteristics for Turbo Pump Unit-Gas Generator Open Loop Test)

  • 문윤완;김승한;설우석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제31회 추계학술대회논문집
    • /
    • pp.15-18
    • /
    • 2008
  • 본 연구에서는 터보펌프 조립체-가스발생기 연계시험 중 개회로 시험에 대한 시동 특성을 분석하였고 수치적으로 해석하였다. 시험에서 터빈의 시동 및 구동은 수소 기체로 수행하였고 그에 따른 가스발생기 점화 및 연소압의 발달을 살펴보았고 해석도 동일한 조건으로 수행하여 결과를 비교하였다. 회전수의 발달 특성은 시험과 잘 일치하는 것을 볼 수 있었고 가스발생기 연소압 발달 특성의 경우 정성적인 기울기가 일치하는 것을 볼 수 있었다.

  • PDF

터보펌프 조립체-가스발생기 연계 폐회로 시험에서의 시동특성 분석 (Analysis of Startup Characteristics for Turbo Pump Unit-Gas Generator Closed Loop Test)

  • 문윤완;김승한;설우석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년도 제31회 추계학술대회논문집
    • /
    • pp.19-22
    • /
    • 2008
  • 본 연구에서는 터보펌프 조립체-가스발생기 연계시험 중 폐회로 시험에 대한 시동 특성을 분석하였고 수치적으로 해석하였다. 시험에서 터빈의 시동은 수소 기체로 수행하였고 구동은 가스발생기에서 연소로 발생하는 연소 기체로 작동하였다. 그에 따른 가스발생기 점화 및 연소압의 발달을 살펴보았고 해석도 동일한 조건으로 수행하여 결과를 비교하였다. 회전수의 발달 특성은 시험과 잘 일치하는 것을 볼 수 있었고 가스발생기 연소압 발달 특성의 경우 정성적으로 일치하는 것을 볼 수 있었다.

  • PDF

소형가스루프 시험조건에서 중형 공정열교환기 시제품의 고온구조해석 (High-Temperature Structural Analysis on the Medium-Scale PHE Prototype under the Test Condition of Small-Scale Gas Loop)

  • 송기남;홍성덕;박홍윤
    • 한국압력기기공학회 논문집
    • /
    • 제8권1호
    • /
    • pp.33-38
    • /
    • 2012
  • A PHE (Process Heat Exchanger) in a nuclear hydrogen system is a key component required to transfer heat energy of $950^{\circ}C$ generated in a VHTR (Very High Temperature Reactor) to a chemical reaction that yields a large quantity of hydrogen. Korea Atomic Energy Research Institute has established a small-scale gas loop for the performance test on VHTR components and recently has manufactured a medium-scale PHE prototype made of Hastelloy-X. A performance test on the PHE prototype is scheduled in the gas loop. In this study, high-temperature structural analysis modeling, and macroscopic thermal and structural analysis of the medium-scale PHE prototype by imposing the established displacement boundary constraints in the previous research were carried out under the gas loop test condition. The results obtained in this study will be compared with performance test results.

엔진 폐열 회수를 위한 랭킨 스팀 사이클 설계 및 HT Boiler의 성능 평가 (Design of Rankine Steam Cycle and Performance Evaluation of HT Boiler for Engine Waste Heat Recovery)

  • 허형석;배석정;이동혁;이헌균;김태진
    • 한국자동차공학회논문집
    • /
    • 제20권2호
    • /
    • pp.21-29
    • /
    • 2012
  • A dual loop waste heat recovery system with Rankine steam cycles for the improvement of fuel efficiency of gasoline vehicles has been investigated. A high temperature loop (HT loop) only recovers the heat of the exhaust gas. A low temperature loop (LT loop) recovers the residual heat from the HT loop, the coolant heat and the remaining exhaust gas heat. The two separate loops are coupled with a heat exchanger. This paper has dealt with a layout of the dual loop system, the review of the working fluids, and the design of the cycle. The design point and the target heat recovery of the HT boiler, a core part of a HT loop, have been presented. The prototype of the HT boiler was evaluated by experiment. For the performance evaluation of the HT boiler, inlet temperature of the HT boiler working fluid was set equal to the temperature degree of sub-cool of $5^{\circ}C$ at the condensing pressure. The exit condition was the degree of super-heat set at $5^{\circ}C$. The characteristics of the HT boiler such as heat recovery and pressure drops of fluids were evaluated with varying flow rates and inlet temperatures of exhaust gas under various evaporating pressure conditions.

Gas turbine Control using Neural-Network 2-DOF PID Controller

  • Kim, Dong-Hwa
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1998년도 춘계학술대회 학술발표 논문집
    • /
    • pp.61-66
    • /
    • 1998
  • Since a gas turbine is made use of generating electricity for peak time, it is a very important to operate a peak time load with safety. The main components of a gas turbine are the compressor, the combustion chamber and the turbine. So, there also must be modeled a component of gas turbines for the control with safety but it is not easy. In this paper we acquire a transfer function based on the operations data of Gun-san gas turbine and study to apply Neural-Network 2-DOF PID controler to control loop of gas turbine to reduce phenomena caused by integral and derivative actions through simulation. We obtained satisfactory results to disturbances of subcontrol loop such as, fuel flow, air flow, turbine extraction temperature.

  • PDF

헬륨가스루프 시험용 공정열교환기에 대한 고온구조해석 모델링(II) (High-Temperature Structural Analysis Model of the Process Heat Exchanger for Helium Gas Loop (II))

  • 송기남;이형연;김찬수;홍성덕;박홍윤
    • 대한기계학회논문집A
    • /
    • 제34권10호
    • /
    • pp.1455-1462
    • /
    • 2010
  • 초고온가스로에서 생성된 $950^{\circ}C$ 정도의 초고온 열을 이용하여 수소를 경제적이며 또한 대량으로 생산하기 위한 시스템이 원자력수소생산시스템이며, 이 시스템에서 공정열교환기는 초고온 열과 황-요오드 공정을 통해 수소를 생산하는 핵심 기기이다. 한국원자력연구원에서는 초고온가스로에 사용될 기기에 대한 성능시험을 위해 헬륨가스루프를 구축하고 공정열교환기 시제품을 제작하였다. 본 연구는 공정열교환기 시제품을 헬륨가스루프에서 시험하기 전에 미리 공정열교환기 시제품의 고온 구조건전성을 평가하기 위한 작업의 일환으로 공정열교환기 시제품에 대한 고온구조해석 모델링, 열해석 및 열팽창해석 결과들을 정리한 것이다. 해석 결과는 공정열교환기 시제품 성능시험 장치 설계에 반영할 것이다.

지식 기반 접근법과 Loop 검증을 이용한 부호운향그래프 자동합성에 관한 연구 (A Study on the Automatic Synthesis of Signed Directed Graph Using Knowledge-based Approach and Loop Verification)

  • 이성근;안대명;황규석
    • 한국가스학회지
    • /
    • 제2권1호
    • /
    • pp.53-58
    • /
    • 1998
  • 화학공정 변수간의 관계를 표현하는 방법으로, 지식기반 접근법을 이용하여 부호유향그래프(signed directed graph, SDG)를 자동합성하였다. SDG의 자동합성은 지식베이스를 이용한 추론과정 및 Loop 검증의 두 단계를 거쳐 수행된다. 먼저, 공정내 장치를 중심으로 장치간의 결합관계를 Topology로 표현하고, Topology 정보를 이용한 공정 변수관계 표현 및 지식베이스의 공정경향 데이타를 문자 패턴 매칭하여 Primary-SDG를 자동으로 합성한다. 생성된 Primary-SDG를 Loop 검증기의 추론을 통하여 검증, 수정하여 SDG를 자동합성하였다.

  • PDF

초임계 영역내 $CO_2$ 냉각 열전달과 압력강하 분석 (Analysis of Heat Transfer and Pressure Drop During Gas Cooling Process of Carbon Dioxide in Transcritical Region)

  • 손창효;이동건;정시영;김영률;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권1호
    • /
    • pp.65-74
    • /
    • 2004
  • The heat transfer coefficient and pressure drop of $CO_2$(R-744) during gas cooling Process of carbon dioxide in a horizontal tube were investigated experimentally and theoretically. The experiments were conducted without oil in the refrigerant loop. The main components of the refrigerant loop consist of a receiver. a variable-speed pump. a mass flowmeter, an evaporator. and a gas cooler(test section). The main components of the water loop consist of a variable-speed Pump. an constant temperature bath. and a flowmeter. The gas cooler is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus The test section consists of smooth, horizontal stainless steel tube of 9.53 mm outer diameter and 7.75 mm inner diameter. The length of test section is 6 m. The refrigerant mass fluxes were 200 ~ 300 kg/($m^2{\cdot}s$) and the inlet pressure of the gas cooler varied from 7.5 MPa to 8.5 MPa. The main results were summarized as follows : The predicted correlation can evaluated the R-744 exit temperature from the gas cooler within ${\pm}10%$ for most of the experimental data, given only the inlet conditions. The predicted gas cooley capacity using log mean temperature difference showed relatively food agreement with gas cooler capacity within ${\pm}5%$. The pressure drop predicted by Blasius estimated the pressure drop on the $CO_2$ side within ${\pm}4.3%$. The predicted heat transfer coefficients using Gnielinski's correlation evaluated the heat transfer coefficients on the $CO_2$ side well within the range of experimental error. The predicted heat transfer coefficients using Gao and Honda's correlation estimated the heat transfer coefficients on the coolant side well within ${\pm}10\;%$. Therefore. The predicted equation's usefulness is demonstrated by analyzing data obtained in experiments.