• Title/Summary/Keyword: Gas liquid chromatography

Search Result 500, Processing Time 0.027 seconds

Analysis of Benzophenone in Sediment and Soil by Gas Chromatography/Mass Spectrometry (기체크로마토그래피/질량분석기에 의한 저질 및 토양시료 중 벤조페논의 분석법 연구)

  • 권오승;김은영;류재천
    • Environmental Analysis Health and Toxicology
    • /
    • v.16 no.3
    • /
    • pp.121-126
    • /
    • 2001
  • Analytical method of benzophenone (BP) in sediment and soil was developed by gas chromatography/mass selective detector/selected ion monitoring (GC/MSD/SIM). The ultrasonic extraction of US EPA (method 3550B) method and liquid-liquid extraction for sediment and soil samples were used for the analysis of BP from sediment and soil. BP was extracted with n-hexane. Organic layer was washed with 5% sodium chloride solution. 1∼2 l of the concentrated solution of organic layer was applied to GC/MSD. The retention time of BP peak was 11.10 min. Recovery (%) of BP by ultrasonication from sediment and soil samples was 96.0∼100.6% and 40.0∼83.0%, respectively. Recovery of BP by liquid-liquid extraction was 51∼59% in soil samples. The detection limit of BP in sediment and soil samples were determined to 0.1 ng/g.

  • PDF

Simultaneous Gas Chromatographic Analysis of Ethanol and Acetic Acid in Vinegar (식초의 에탄올 및 초산 함량의 동시분석)

  • Yoon, Hee-Nam
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.1247-1251
    • /
    • 1998
  • A method is developed for simultaneously determining ethanol and acetic acid in vinegars by quantitative packed-column gas chromatography. Vinegars were filtrated and directly chromatographed on a $2\;m{\times}2\;mm$ stainless steel column packed with Tenax-GC, 80/100. Ethanol, isopropy alcohol as an internal standard, and acetic acid were completely separated within 20 min of running time without any interfering peaks. The accuracy of packed column gas solid chromatography (PCGSC) was discussed compared to the analytical data by titration, high performance liquid chromatography and capillary column gas liquid chromatography (CCGLC).

  • PDF

The study on the analysis of α-naphthylamine in urine (요중 알파나프틸아민 분석에 관한 연구)

  • kim, Choon Sung;Roh, Jae Hoon;Bae, Mun Joo;Kim, Chi Nyon;Lim, Nam Gu;Won, Jong Uk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.1
    • /
    • pp.49-59
    • /
    • 1997
  • This study was performed to analyze the purity of technical grade ${\alpha}$-naphthylamine, to establish optimal analytical condition of ${\alpha}$-naphthylamine in urine and to determine the urine sample of workers exposed to ${\alpha}$-naphthylamine. The purity of technical grade ${\alpha}$-naphthylamine were $96.5{\pm}2.38%$, $94.1{\pm}0.97%$, $97.0{\pm}0.02%$ by gas chromatography-mass selective detector. To analyze ${\alpha}$-naphthylamine in urine, high performance liquid chromatography-electrochemical detector and gas chromatography-electron capture detector operating conditions have been optimized by preliminary expriment. In high performance liquid chromatography-electrochemical detector, the mobile phase was consisted of acetonitrile(35%) and water(65%), and the flow rate was maintained at 1.0ml per minute. Optimal detective condition was 9.0V(10nA/V) of electrochemical detector. The recovery of sep-pak treatment method was highly estimated as pretreatment of ${\alpha}$-naphthylamine in urine. The free amine was isolated by gas chromatography-electron capture detector after basic hydrosis, sep-pak treatment, toluene elution and HFBA(heptafluoro-butyric anhydride) derivatization of urine. The recovery of ${\alpha}$-naphthylamine in urine was $98.73{\pm}3.29%$ by gas chromatography-electron capture detector. The sensitivity was more higher than that of high performance liquid chromatography-electrochemical detector. Urinary ${\alpha}$-naphthylamine was detected in only one worker among nine workers. The level of ${\alpha}$-naphthylamine in urine was 6.42 ng/ml.

  • PDF

On the Pyrolysis of Polymers III. Identification of Gases from Rubber Pyrolysis by Gas Chromatography (高分子物質의 熱分解에 關한 硏究 (第3報) 合成고무類의 熱分解生成物의 Gas Chromatography에 의한 檢索과 合成고무 確認에의 利用)

  • Chwa-Kyung Sung
    • Journal of the Korean Chemical Society
    • /
    • v.7 no.2
    • /
    • pp.115-121
    • /
    • 1963
  • Aliphatic hydrocarbon gases from rubber pyrolysis have been identified by gas chromatography with tetraethyleneglycol dimethylether column. Rubbers used in this work are polyisoprene, SBR, NBR, polybutadiene, buthyl rubber, polychloroprene and polyurethane rubber. The chromatogram is characteristic for each polymer. Author proposes a method of identification of synthetic rubbers by gas chromatograph of pyrolyzed gas. Sample is pyrolyzed at $450^{\circ}C$ under nitrogen or more effectively helium and gaseous portion, which eliminated liquid condensate, is passed to the column. The appearance of exclusively large peak of isoprene, isobutylene and carbon dioxide shows the presence of polyisoprene, polyisobutylene and polyurethane, respectively. Large peak of butadiene will appear in case of polybutadiene, SBR and NBR, but SBR can be identified through the styrene peak in gas chromatogram of liquid pyrolyzate and NBR can be identified by the evolution of hydrogen cyanide during pyrolysis. Polychloroprene is identified by the evolution of hydrogen chloride. This method could be applied to the identification of copolymer or polymer blend.

  • PDF

Comparison of Liquid Chromatography-Mass/Mass Spectrometry (MS) and Gas Chromatography-MS for Quantitative Analysis of Indole-3-acetic acid and Indole-3-butyric acid from the Concentrated Liquid Fertilizer (Liquid Chromatography-Mass/Mass Spectrometry (MS)와 Gas Chromatography-MS를 이용한 농축 액상 비료제품 중 Indole-3-acetic acid 및 Indole-3-butyric acid 정량분석능 비교)

  • Kim, Jin Hyo;Park, Jong Min;Choi, Geun-Hyoung;Park, Yun-Ki;Im, Geon-Jae;Kim, Doo-Ho;Kwon, Oh-Kyung
    • Journal of Applied Biological Chemistry
    • /
    • v.56 no.1
    • /
    • pp.53-57
    • /
    • 2013
  • In here, we investigated the quantitative analysis method of indole-3-acetic acid (IAA) and indole-3-butyric acid (IBA) with liquid chromatography-mass/mass spectrometry (LC-MS/MS) or gas chromatography-MS. Two ways of clean-up process were investigated for LC-MS/MS instrumental analysis of IAA, but both a simple dilution and hydrophile-lipophile balance (HLB) solid phase extraction (SPE) were not met the optimal recovery rates for quantitative analysis. On the other hand, the clean-up method for GC-MS was finally optimized through HLB-SPE from 250-folds diluted sample and methylation with trimethylsilyl chloride in methanol for 4 h. The limit of detection for methyl ester of IAA and IBA were both 1.4 mg/L, and recovery rates showed 93-107% from the concentrated liquid fertilizer.

Determination of Dienestrol in Dienestrol Cream by Gas Liquid Chromatography (Gas Liquid Chromatography에 의한 Dienestrol Cream 중의 Dienestrol 정량)

  • 백남호;박만기;염정록
    • YAKHAK HOEJI
    • /
    • v.23 no.1
    • /
    • pp.7-10
    • /
    • 1979
  • A gas chromatographic determination of dienestrol in dienestrol cream has been studied. Dienestrol cream was dissolved in pyridine and silylation was done by using N, O-bis (trimethylsilyl) trifluoroacetamide. The derivative was injected into 3% silicone OV-17 column for chromatographic estimation. The dienestrol peak was found to be well separated from the other components of the cream. The detection limit was obtained to be $5.6{\times}10^{11}$ mol of dienestrol for this method. As there is no need for prior separation procedure, this experiment is extremely simple and less time consuming as compared to the conventional methods for estimation of dienestrol in cream.

  • PDF

Determination of Ethambutol by Gas liquid Chromatography (Gas-liquid Chromatography에 의한 Ethambutol의 정량)

  • 이왕규;강길종;박만기
    • YAKHAK HOEJI
    • /
    • v.19 no.4
    • /
    • pp.240-245
    • /
    • 1975
  • The quantitative analysis of ethambutol.2HCl as well as commercial ehambutol preparations was undertaken by gas-liquid chromatography by finding optimum conditions, such as the use of internal standard, stability of an ethambutol-2HCl-caffeine standard solution, and the effect of column temperature, N, O-bis-(trimethylsily) acetamide [B.S.A.] concentrations and other substances present in the preparations. Under the chromatiographic conditions, an ethambutol-2HCl. caffeine standard, 9 min, 30sec. The relative molar response of ethambutol.2HCl and caffeine studied was 2.08. Ethambutol.2HCl could be quantitated up to 1$\times$10$^{-8}$ moles. the possible decomposition of B.S.A. due to the moisture when tested and the incoplete reaction for silylation could be minimized.

  • PDF

Quantitative analysis of lee Amino Acids in Human Blood Seum by Gas-Liquid Chromatography

  • Seo, Bae-Seok;Kim, Ui-Rak;Lee, Kyu-Yong
    • Nuclear Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.3-8
    • /
    • 1975
  • The quantitative analysis of various kinds of free amino acids contained in blood serum of patients with chronic mandible ostities, epidermic hemorrhagic fever, chronic renal failure and liver cirrhosis were measured with the gas-liquid chromatography (G. L. C.). The results compared with the quantity of free amino acids of healthy persons. It was found that the quantity of free amino acids were differently contained in blood serum in accordance with kinds of patients.

  • PDF