• 제목/요약/키워드: Gas hold-up

검색결과 27건 처리시간 0.025초

충전탑에서 수력학적 거동의 수학적 해석 연구 (A Study on the Mathematical Interpretation o Hydraulic Behaviour in Packing Tower)

  • 김석택
    • 한국대기환경학회지
    • /
    • 제17권1호
    • /
    • pp.51-56
    • /
    • 2001
  • This study was carried out to interpret mathematically hydraulic behaviour in packing tower which packed 50 mm plastic Hiflow-ring with a dimension of 300 mm wide and 1,400 mm high. In view of energy saving, the recent packing. 50 mm plastic Higlow-ring was superior to conventional packings because of low pressure drop in high loads. As relative error between numerically predicted and experimentally obtained values was less then 6% in the loading and flooding point, it found that therir results appeared to be adequate. Comparison of hose two values in both dry and wet packing conditions. relative errors amount to 3.96 and 5.6%, respectively. In order to evaluate the operating characteristics of packing, the type, size, and material for packings must be estimated in various system and loads. This study is able to calculated pressure drop, hold-up, gas and liquid loads using mathematical interpretation. For these calculation, the specific constants of each packings must be calculated first all. The method of mathematical interpretation in this study turned out to be superior to the existing methods because of reduced errors at loading and flooding point.

  • PDF

고로하부 액체유동에 대한 수치해석 사례 - 냉간유동 (Numerical Simulation of the Liquid Flow in the Lower Part of the Blast Furnace - A Cold Flow Case)

  • 진홍종;최상민;정진경
    • 한국연소학회지
    • /
    • 제13권2호
    • /
    • pp.33-41
    • /
    • 2008
  • The high permeability of the gas in the molten iron of the dripping zone of the blast furnace is a major factor in achieving the stable operation of a furnace with high productivity. Basic studies of the liquid flow behavior in a packed bed are necessary to grasp the effect of various operational changes on conditions in the dropping zone. Molten iron and slag together playa critical role in the lower zone, transporting mass and energy, while impairing and redistributing the gas flow. In turn, molten iron and slag undergo physical and chemical changes, and are redistributed radially as they descend to the hearth. In this research, mathematical formulations are derived for the gas and the liquid. The solid phase is fixed with constant porosity. The information for the molten iron and slag includes the hold-up, velocity, pressure, and information related to the areas of interaction between the gas and the liquid, and the solid and the liquid. Predictable results include the velocity, pressure and temperature distribution. Additional parameters include the packed particle size and the air blast rate.

  • PDF

오일-질소가스 혼합유체를 이용한 고온 오일플러싱 시스템 공정설계에 관한 연구 (A Study on Process Design of Hot Oil Flushing System Using Oil-Nitrogen Gas Mixing Fluid)

  • 이윤호;최부홍
    • 해양환경안전학회지
    • /
    • 제23권5호
    • /
    • pp.541-548
    • /
    • 2017
  • 본 연구에서는 해양플랜트설비 건조 현장에서 사용되고 있는 기존 고온 오일 플러싱 장비에 대한 성능개선을 위해 기존의 플러싱 장치에 사용되던 오일에 질소가스를 혼합한 고온 오일 플러싱 시스템에 대하여 국제표준화기구 코드(ISO code)를 기준으로 이론적 연구를 수행하였다. 연구를 위해 오일-질소가스 혼합유체 플러싱 시스템 공정을 설계 후 청정성능에 영향을 주는 혼합유체의 혼합비율, 온도, 레이놀즈수 및 액상분율 등에 대한 공정모사 결과도 분석하였다. 그 결과 관 직경과 가스상의 체적분률이 일정한 상태에서 혼합유체의 체적유량이 증가될수록 수평 유압배관 입출구의 액상분율 차이 ${\Delta}{\alpha}_L$ 값은 증가하게 되고 배관길이 방향의 위치에 따라 오일과 질소가스 기포 사이의 상분포가 달라짐을 확인했다. 이러한 상분포의 변화는 오일-질소가스 혼합유체 플러싱 시스템의 청정성능에도 커다란 영향을 줄 것으로 예상된다.

표면특성에 따른 물맺힘 특성이 가스흡착성에 미치는 영향 (The Effect on Gas Adsoption Efficiency for Various Surface Characteristics)

  • 허경욱;신종민
    • 설비공학논문집
    • /
    • 제14권8호
    • /
    • pp.671-675
    • /
    • 2002
  • The gas adsorption efficiency for various surfaces with three different characteristics has been reviewed. The dimethyl disulfide gas has been used to investigate characteristics of gas adsorption for different surface characteristics such as plasma treated, lacquer coated and untreated. Three different surfaces were evaluated in dry conditions initially and tested at wet surface conditions with spraying water to evaluate the gas adsorption efficiency which usually occurred at defrost cycles. The results show that the gas adsorption of the plasma treated sample has better performance than others. The lacquer coated and untreated samples showed the similar result, but the lacquer coated sample showed a slightly better performance.

A New Start-up Method for a Load Commutated Inverter for Large Synchronous Generator of Gas-Turbine

  • An, Hyunsung;Cha, Hanju
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.201-210
    • /
    • 2018
  • This paper proposes a new start-up method for a load commutated inverter (LCI) in a large synchronous gas-turbine generator. The initial rotor position for start-up torque is detected by the proposed initial angle detector, which consists of an integrator and a phase-locked loop. The initial rotor position is accurately detected within 150ms, and the angle difference between the real position and the detected position is less than 1%. The LCI system operates in two modes (forced commutation mode and natural commutation mode) according to operating speed range. The proposed controllers include a forced commutation controller for the low-speed range, a PI speed controller and a PI current controller, where the forced commutation controller is connected to the current controller in parallel. The current controller is modeled by Matlab/Simulink, where a six-pulse delay of the thyristor and a processing delay are considered by using a zero-order hold. The performance of the proposed start-up method is evaluated in Matlab/Psim at standstill and at low speed. To verify the feasibility of the method, a 5kVA LCI system prototype is implemented, and the proposed initial angle detector and the system performance are confirmed by experimental results from standstill to 900rpm.

역류식 충전탑에서 Raschig Super-ring Random Packing의 수력학적 특성에 대한 연구 (A Study on the Hydraulic Characteristics of Rashig Super-Ring Random Packing in a Counter-Current Packed Tower)

  • 강성진;임동하
    • 청정기술
    • /
    • 제26권2호
    • /
    • pp.102-108
    • /
    • 2020
  • 오늘날 석유화학, 정밀화학, 대기오염 방지산업 등에서 증류, 흡수, 추출, 탈거 등 물질분리 단위공정으로 주로 충전탑을 사용해 왔다. 충전탑은 가스-액체, 가스-가스 시스템에서의 물질들과의 접촉에 의해 운전되어 진다. 이러한 충전탑은 낮은 압력손실, 경제적 효율, 고온성 액체물질 적용, 유지보수 용이, 유해가스 처리 등의 운영에서 장점들을 가진다. 충전탑의 성능은 충진물을 통해 가스와 액체를 고르게 분산함으로써 우수한 성능을 보이며, 이는 충전탑 설계에 있어 중요한 인자로 고려되어진다. 본 실험에서는 충진물에 대한 액체부하 및 가스용량인자에 따른 건조압력손실, 수력학적 압력손실, 액체함량 변화에 대한 기하학적 특성에 대하여 연구하였다. 결과로부터 설계인자와 운전조건 등의 유해가스 처리에 필요한 인자를 도출하였다. 임의 충진물인 raschig super-ring에 대한 건조압력손실을 측정한 결과, 가스용량인자가 증가할수록 일정하게 선형적으로 증가하였고, 가스용량인자가 0.630 ~ 3.448 kg-1/2 m-1/2 S-1에서 건조압력손실은 1.892 ~ 47.312 mmH2O m-1로 기존 산업현장에서 보편적으로 사용되는 35 mm pall-ring보다도 낮은 압력손실을 보였다. 그리고 raschig super-ring에 대한 수력학적 압력손실을 측정한 결과, 고유 액체부하에 대하여 가스용량인자가 증가할수록 압력손실도 함께 증가함을 확인하였고, 액체부하 변화에 따른 가스용량인자가 1.855 ~ 2.323 kg-1/2 m-1/2 S-1으로 20% 증가할 때, 압력손실은 약 17% 증가하는 것으로 나타났다. 마지막으로, 충진물 체적에 관한 액체함량은 가스용량인자에 의존된 액체부하 매개변수로서 액체부하 변화에 따른 가스용량인자 약 3.84 kg-1/2 m-1/2 S-1까지는 거의 일정한 액체함량을 보였으나, 그 이상에서는 급격하게 증가하였다.

점적상 반응기에서 액상흐름의 체류시간 분포 및 물질전달 (Residence Time Distributions of Liquid pbase Flow and Mass Transfers in the Trickle Bed Reactor)

  • 김기창
    • 산업기술연구
    • /
    • 제6권
    • /
    • pp.19-31
    • /
    • 1986
  • The residence time distribution of liquid flow in a 4.0cm diameter column packed with porous $Al_2O_3$ spheres of 0.37cm diameter were measured with pulse injections of a tracer under cocurrent trickling flow conditions. The mean residence time of liquid flow and liquid hold-up calculated by the transient curve of tracer were unaffected by gas flow rates under experimental ranges of liquid flow rates from 2.4 to $4.5(kg/m^2\;sec)$ and gas flow rates from 0 to $0.13(kg/m^2\;sec)$. The axial dispersion coefficient of liquid stream and apparent diffusivity of tracer in a micropore of solid particle were estimated from the response curve of tracer. The calculated Peclet No. were increased in ranges of 68-to 82 with a increasing of liquid mass velocity, and the external effective contacting efficiency between liquid and solid which can be expressed. by $(D_i)_{app}/D_i$ varied in ranges of 0.54 to 0.68 depending on the liquid flow rates. The gas to liquid(water) volumetric mass transfer coefficient were determined from desorption experiments with oxygen at $25^{\circ}C$ and 1 atm. The measured mass transfer coefficients were increased with liquid flow rates and the effect of gas flow rates on the mass transfer coefficient was insignificant.

  • PDF

도서관자료(圖書館資料) 보존(保存)에 관한 연구(硏究) (A Study on the Conservation of Library Materials)

  • 권기원
    • 한국비블리아학회지
    • /
    • 제6권1호
    • /
    • pp.179-213
    • /
    • 1984
  • The history of recording and conserving for maintenance the human's memory from ancient times to modern's has brought about a lot of changing process of the recorded information media with developing in culture, and each society has made important recorded materials in his library as essentially the social apparatus. But most of them that were damaged by factors of the natural disaster, humidity, temperature, light, fungi and insects in the library, and were resulted in deterioration and losing the numerous materials. For removing the inevitable phases repeated, there are studying for counterplan of the fundamental environment factors about preservation, restoration and chemical research of materials in advanced countries, but I get a few researches about protecting the cultural properties. Therefore I research the survey of the actual conditions on 72 university libraries centering around them, and then I have researched the collection rate 81 percent, 58 university libraries. (local : 35, in seoul : 23) As the result of this research, I propose the model of the environment factors of conserving the library materials. 1) To apply the equipment of processing the radiant energy to the new construction and buildings. 2) To remove factors that occur fungi and insects by facilities being controlled relative humility, temperature, and to equip the ventilation arrangement in the library. 3) To shelve all acquired and bound materials after proceeding the vacuum fumigator. 4) Those who want to enter into the library stack were surely taken in sterilzing their hands and shoes, and must put on the gown. 5) To use the vacuum dusting thing (machine) for removing the dust without spreading out the floor of the library at any time. 6) To set up the gas automatic fire extinguisher worked by smoke sensor. 7) To assist the research into the preservation, natures and environment of recorded materials, and to supply financial funds for librarian. 8) To hold regularly the workshop be able to educate the methods of preservation materials by the constant system. (Library Association) 9) To add to responsibilities on certification of preservation materials for librarian. 10) To hold the constant committee system in each library. 11) To keep up with the ideal environment (humidity, temperature, light, ventilation, etc.) of preservation materials in the arrangement room, and to put on the gown.

  • PDF

내부 삽입물을 적용한 유동층 반응기에서 WGS 촉매의 CO 전화율에 미치는 조업변수들의 영향 (Effects of Operating Variables on CO Conversion of WGS Catalyst in a Fluidized Bed Reactor Equipped with Bed Insert)

  • 박지혜;이동호;박영철;문종호;이영우;류호정
    • 한국수소및신에너지학회논문집
    • /
    • 제25권2호
    • /
    • pp.209-217
    • /
    • 2014
  • To enhance the performance of SEWGS system by holding the WGS catalyst in a SEWGS reactor, a spring type bed insert was developed. In this study, effects of operating variables such as steam/CO ratio, gas velocity, syngas concentration on CO conversion were investigated in a fluidized bed reactor using the spring type bed insert to hold the WGS catalyst as tablet shape. CO conversion increased initially as the steam/CO ratio increased. But further increment of the steam/CO ratio caused decreasing of CO conversion because of increment of gas velocity and decrement of syngas concentration. Moreover, CO conversion decreased as the gas velocity increased and the syngas concentration decreased at the same steam/CO ratio. Continuous operation up to 48 hours (2 days) was carried out to check reactivity decay of WGS catalyst supported by spring type bed insert. The average CO conversion was 99.04% and we could conclude that the WGS reactivity at those conditions was maintained up to 48 hours.

4각 순환유동층의 수력학적 특성 (Hydrodynamic Characteristics of the Rectangular Type Circulating Fluidized Bed)

  • 현상열;이관석
    • 열처리공학회지
    • /
    • 제10권4호
    • /
    • pp.232-236
    • /
    • 1997
  • A rectangular type circulating fluidized bed (CFB) with an internal nozzle and two partition walls was proposed. In this modified CFB, an internal nozzle and two slanted partition walls were additionally set in the riser. This cold mode apparatus was made of acrylic resin; the riser was 1500mm high and $1000{\times}1000mm^2$ in the cross sectional area, the internal nozzle was 200mm high and 10mm in the inner diameter, and the partition wall was 7mm thick. Glass beads of $91{\mu}m$ in the mean diameter were employed as bed materials. In the cold mode by using the proposed CFB with an internal nozzle, it was possible to change the particle hold up by changing the gas flow ratio of the nozzle to the total(Qn/Qt). It was found that the inflection point which devided the bed structure between the dense and the dilute phase in the riser varied with Qn/Qt.

  • PDF