Effects of Gas Injection on the Heating Performance of a Two-Stage Heat Pump Using a Twin Rotary Compressor with Refrigerant Charge Amount

  • Heo, Jae-Hyeok;Jeong, Min-Woo;Jeon, Jong-Ug;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권3호
    • /
    • pp.77-82
    • /
    • 2008
  • For heat pumps used in a cold region, it is very important to obtain appropriate heating capacity. Several studies using a variable speed compressor and an additional heater have been performed to enhance heating capacity at low ambient temperatures. However, for outdoor temperature conditions below $-15^{\circ}C$, it is still difficult to obtain enough heating capacity above the rated value. In recent studies, the application of gas injection technique into a two-stage heat pump yielded noticeable heating performance improvement at low temperature conditions. In this study, the heating performance of a two-stage gas injection heat pump with a rated capacity of 3.5 kW was measured and analyzed by varying refrigerant charge amount and EEV opening at the standard heating condition. The heating performance of the two-stage gas injection heat pump was compared with that of a two-stage non-injection heat pump. The heating capacity and COP of the two-stage gas injection heat pump were improved by 2-10% at the optimal charging condition over those of the two-stage non-injection heat pump.

기액분리기를 적용한 가스 인젝션 히트펌프의 성능 향상에 관한 실험적 연구 (The Performance Improvement of a Gas Injection Heat Pump with a Flash Tank)

  • 손길수;김동우;최성경;김용찬
    • 설비공학논문집
    • /
    • 제29권6호
    • /
    • pp.297-305
    • /
    • 2017
  • Air-source heat pumps are widely used in residential heating systems. However, the decrease in the capacity of the heat pump is unavoidable when operating at very low and high ambient temperatures. The vapor injection technique is considered a promising technology to overcome this problem. Recent research on vapor injection cycles have mainly adopted a scroll compressor with an internal heat exchanger at severe operating conditions. This study measured the COP and EER of a gas injection heat pump using a flash tank with an inverter-driven rotary compressor at severe operating conditions. Compared to non-injection heat pumps, the heating capacity and COP of the gas injection heat pump improved up to 15% and 2.9%, respectively, at outdoor temperatures of $-10^{\circ}C$ to $7^{\circ}C$. The cooling capacity of the gas injection heat pump was 11% higher than the non-injection heat pump at an outdoor temperature of $35^{\circ}C$. At the same time, the EER of the gas injection heat pump was similar to that of the non-injection heat pump.

R134a 냉매용 초임계 히트펌프의 성능 특성 (Performance Characteristics of R134a Supercritical Heat Pump)

  • 최인수
    • 동력기계공학회지
    • /
    • 제18권4호
    • /
    • pp.60-65
    • /
    • 2014
  • In this paper, cycle performance analysis for heating capacity, compression work and COP of R134a supercritical heat pump is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include superheating degree, pressure and outlet temperature of gas cooler, compressor efficiency and evaporating temperature in the R134a supercritical heat pump system. The main results were summarized as follows : Superheating degree, pressure and outlet temperature of gas cooler, compressor efficiency and evaporating temperature of R134a heat pump system have an effect on the heating capacity, compression work and COP of this system. With a thorough grasp of these effect, it is necessary to design the supercritical heat pump using R134a. The prediction for COP of R134a supercritical heat pump have been proposed through multiple regression analysis.

공동주택의 공기열원 히트펌프 적용가능성 검토를 위한 운전성능 및 탄소배출량 평가 (Evaluation of Operational Performance and Carbon Emissions for the Feasibility of Air Source Heat Pump Application in Residential Buildings)

  • 김준석;김종수;전용석
    • 한국지열·수열에너지학회논문집
    • /
    • 제20권2호
    • /
    • pp.24-36
    • /
    • 2024
  • This study analyzed the feasibility of the air source heat pump in residential buildings based on operational performance and carbon emissions. The operational performance and carbon emissions were compared between a gas boiler and an air source heat pump by calculating the annual heating and hot water load based on the 21A and 36A models for actual residential buildings. For the operational performance of the air source heat pump, the lowest (2.3) and highest COP (5.9) were attained during the winter and summer seasons, respectively. The carbon emissions depend on the amount of energy consumed during operations. An air source heat pump consumed 65.10% and 65.4% less energy per year in the 21A and 36A models, respectively compared to the existing gas boiler. Consequently, for air source heat pump carbon emissions were also reduced by 13.3% and 15.1% per year for the 21A and 36A models, respectively. It shows the effectiveness of applying an air source heat pump compared to an existing gas boiler.

캘리포니아 표준테스트 방법을 사용한 전기냉방기기의 가스냉방기기 대체에 따른 편익비용분석 (Benefit-Cost Analysis in Accordance with Replacement of Electrical Cooling System by Gas Cooling System using the California Standard Test)

  • 박래준;송경빈;원종률
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1774-1781
    • /
    • 2012
  • There are some efforts to improve the performance of electrical heat pump(EHP) and replace it with an alternative cooling equipment such as gas engine-driven heat pump(GHP), a gas cooling equipment, in order to solve the problem of summer electricity supply through reducing the summer electricity peak. This paper analyzes cost-benefit in accordance with replacement of electrical cooling system by gas cooling system using california standard test and sensitivity analysis of some scenarios.

건축물 냉.난방 시스템에 따른 에너지 소비 특성 -서울 소재 A 대학교 건축물을 중심으로- (The Energy Consumption Characteristics of Building Accordance with Air-Conditioning and Heating System)

  • 박강현;차정훈;김수민
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.333-337
    • /
    • 2011
  • Central control air-conditioning systems are being replaced with individually controlled air-conditioning system in the university. The amount of growth of electricity consumption is due to the increasing demand of electric heat pump. In winter and summer, the energy consumption showed a tendency to increase. On the other hand, showed less energy in spring and autumn. Increase the amount of electricity than the degree of decline in gas consumption was higher. Can be considered as transitional phenomena. Because electric heat pump, gas driven heat pump and the absorption chiller-heater are used at the same time in some of the buildings.

  • PDF

장벽 방전형 공기 펌프의 이온풍 발생에 미치는 방전전극 형상의 영향 (Effect of Discharge Electrode Shape of a Barrier Discharge Type Gas Pump on Ionic Wind Generation)

  • 황덕현;문재덕
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.994-998
    • /
    • 2009
  • Existing cooling technologies no longer provide adequate heat dissipation due to excessive heat generation caused by the growing component density on electronic devices. An ionic gas pump can be used for the thermal management of micro-electronic devices, since the size of pump can be reduced to a micrometer scale. In addition, the gas pump allows for gas flow control and generation without moving parts. This ideal property of gas pump gives rise to a variety of applications. However, all these applications require maximizing the wind velocity of gas pump. In this study a barrier discharge type gas pump, with a needle-shaped corona electrode instead of a plate-shaped corona electrode, has been investigated by focusing on the corona electrode shape on the wind velocity and wind generation yield. As a result, the enhanced wind velocity and wind generation yield of 1.76 and 3.37 times were obtained with the needle-shaped corona electrode as compared with the plate-shaped corona electrode of the proposed barrier discharge type gas pump.

냉매 충전량에 따른 CO2용 수냉식 열펌프의 성능 특성에 관한 연구 (Performance Characteristics of Water-Chilling Heat Pump Using CO2 on Variation of Refrigerant Charge Amount)

  • 손창효;유태근;장승일;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.558-566
    • /
    • 2007
  • The performance characteristics of water-chilling heat pump using $CO_2$ with respect to variation of refrigerant charge amount was investigated experimentally. An experimental apparatus is consisted of a compressor, a gas cooler, an expansion valve, an evaporator and a liquid receiver. All heat exchangers used in the test rig are counter-flow-type heat exchangers with concentric dual tubes, which are made of copper. The gas cooler and the evaporator consist of 6 and 4 straight sections respectively arranged in parallel, each has 2400 mm length. The experimental results summarize as the followings : As the refrigerant charge ratio of $CO_2$ heat pump system increases, the discharge pressure and compressor ratio increases, but mass flow rate of refrigerant decreases. Also the compressor work increases with the increase of refrigerant charge ratio. However, the heating and cooling capacity of $CO_2$ heat pump decreases as the refrigerant charge ratio increases. The maximum heating COP of $CO_2$ heat pump system presented at 0.25 refrigerant charge ratio. It is possible to confirm the optimum charge ratio of $CO_2$ heat pump system by the viewpoint of heating COP.

A Third-order Simulation Model of a Vuilleumier Cycle Heat Pump

  • Kang, Young-Goo;Jeong, Eun-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.80-92
    • /
    • 1998
  • A third-order simulation model of a Vuilleumier{VM) heat pump has been developed. This model takes into account the major losses such as the heat conduction losses through regenerators and displacers, the pumping losses and the wall-to-gas heat transfer losses in active volumes, in addition to the heat exchanger and regenerator losses. The working volume was divided into 12 control volumes and the conservation equations of mass and energy were applied to each control volume. Pressure drops were considered in regenerators only. Thermodynamic behavior of the working gas in a VM heat pump was investigated and effects of the major losses and operating conditions on the performance of a VM heat pump were shown.

  • PDF

냉방기기 사용량과 특성을 고려한 가스냉방기기의 전력대체 효과 분석 (Analysis of Electric Substitution Effects by the Gas Consumption and Characteristics of Gas Cooling System)

  • 박래준;송경빈
    • 전기학회논문지
    • /
    • 제61권5호
    • /
    • pp.669-675
    • /
    • 2012
  • Recently, the amount of electrical heat pump(EHP), a electrical conditioning equipment, is sharply increasing due to the luxury and multi-story trend of building. Accordingly, the cooling load that occupying substantial part of summer electric consumption has increased dramatically, making difficulties in domestic supply of electricity in summer. There are some efforts to replace it with an alternative cooling equipment such as gas heat pump(GHP), a gas cooling equipment, in order to solve the problem of summer electricity supply through reducing the summer electricity peak. It is rare, however, to find studies on the actual effects of GHP on the reduction of summer electricity peak. This study, therefore, estimated the effects of the GHP on the summer electricity peak by the gas consumption and characteristics of gas cooling systems. In addition, electric substitution effects by gas cooling systems were analyzed through case studies in the summer of 2010.