• Title/Summary/Keyword: Gas hazardous test

Search Result 42, Processing Time 0.029 seconds

Performance Evaluation of Advance Warning System for Transporting Hazardous Materials (위험물 운송을 위한 조기경보시스뎀 성능평가)

  • Oh Sei-Chang;Cho Yong-Sung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.4 no.1 s.6
    • /
    • pp.15-29
    • /
    • 2005
  • Truck Shipment Safety Information, which is a part of the development of NERIS is divided into Optimal Route Guidance System and Emergency Response System. This research is for establishing an advance warning system, which aims for preventing damages(fire, explosion, gas-escape etc.) and detecting incidents that are able to happen during transporting hazardous materials in advance through monitoring the position of moving vehicles and the state of hazardous materials in real-time. This research is peformed to confirm the practical possibility of application of the advance warning system that monitors whether the hazardous materials transport vehicles move the allowed routes, finds the time and the location of incidents of the vehicles promptly and develops the emergency system that is able to respond to the incidents as well by using the technologies of CPS, CDMA and CIS with testing the ability of performance. As the results of the test, communication accuracies are 99$\%$ in freeway, 96$\%$ in arterial, 97$\%$ in hilly sections, 99$\%$ in normal sections, 96$\%$ in local sections, 99$\%$ in urban sections and 98$\%$ in tunnels. According to those results, the system has been recorded a high success rate of communication that enough to apply to the real site. However, the weak point appeared through the testing is that the system has a limitation of communication that is caused in the rural areas and certain areas where are fewer antennas that make communication possible between on-board unit and management server. Consequently, for the practical use of this system, it is essential to develop the exclusive en-board unit for the vehicles and find the method that supplements the receiving limitation of the GPS coordinates inside tunnels. Additionally, this system can be used to regulate illegal acts automatically such as illegal negligence of hazardous materials. And the system can be applied to the study about an application scheme as a guideline for transporting hazardous materials because there is no certain management system and act of toxic substances in Korea.

  • PDF

A Case Study of Bottom Liner Construction Using Composite Liner Technology in a Solid Waste Landfill (복합차수층 조성기술을 이용한 폐기물매립지 바닥차수층 시공사례)

  • Lee, Kyu-Jung;Lee, Nam-Hoon;Park, Soo-Young;Jeon, Won-Pyo;Lee, Chae-Young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.15 no.3
    • /
    • pp.90-96
    • /
    • 2007
  • Modern waste management units, so-called "landfills" protect human health and environment from hazardous leachate and gas. Accordingly, it must be constructed with a bottom liner system that includes a gas collection layer. Leachate is the contaminated liquid that drains from the waste material pollutes ground water. For this reason. bottom liner system must have durability and low hydraulic conductivity (in case of compacted clay liner, no more than $1{\times}10^{-7}cm/sec$ ). P county in Kangwon province constructed a solid waste landfill with bottom liner system. In this study. it is mainly introduced that the test results on construction and quality control of bottom liner system by "Multiple composite liner construction technology", which is selected for bottom liner system in P solid waste landfill.

  • PDF

Hazard Assessment of Combustion Gases from Interior Materials (주요 건축 내장재의 연소가스 유해성 평가)

  • Seo, Hyun Jeong;Son, Dong Won
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.49-56
    • /
    • 2015
  • Toxic gases from five types of interior building materials were investigated according to Naval Engineering Standard (NES) 713. The materials were plywood, indoor wall coverings (wood wall plate members and pine wood), reinforced Styrofoam insulation, laminate flooring, and PVC. Specimens were measured using an NES 713 toxicity test apparatus to analyze the hazardous substances in combustion gas from the materials. We used the US Department of Defense standard (MIL-DTL, Military Standard) to calculate the toxicity index of the combustion gas. Emissions of $CO_2$ from all specimens did not exceed the NES 713 limit of 100,000 ppm. The amount of CO gas emissions from reinforced Styrofoam insulation was 6,098 ppm. 25 ppm and 49 ppm of formaldehyde were released from the reinforced Styrofoam insulation and PVC flooring, respectively. These values were less than the limit of 400 ppm. The highest emissions were from $NO_X$ emitted by plywood and were above the limit of 250 ppm. The toxicity index of the specimens were calculated as 5.19 for plywood, 4.13 for PVC flooring, 2.35 for reinforced Styrofoam insulation, 2.34 for laminate flooring, and 1.22 for indoor wall coverings (pine wood). Our research helps us to understand the properties of these five interior materials by analyzing the combustion gas and explaining the toxicity of constituents and the toxicity index. Also, it would be useful for giving fundamentals to guide the safe use of interior materials for applications.

The Design and Implementation of a Real-Time FMD Cattle Burial Sites Monitoring System Based-on Wireless Environmental Sensors (u-EMS : 센서네트워크 기반의 가축매몰지 악취환경정보 실시간 모니터링 시스템 설계 및 구현)

  • Moon, Seung-Jin;Kim, Hong-Gyu;Park, Kyu-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.12B
    • /
    • pp.1708-1721
    • /
    • 2011
  • Recent outbreak of cattle diseases such as foot-and-mouth disease(FMD) requires constant monitoring of burial sites of mass cull of cattles. However, current monitoring system takes environmental samples from burial sites with period of between one and two weeks, which makes it impossible for non-stop management of hazardous bio-waste. Therefore, in this study, we suggest an improved real-time environmental monitoring system for such bio-hazardous sites based on wireless sensor networks, which makes constant surveillance of the FMD burial sites possible. The system consists mainly several wireless environmental monitoring sensors(i.e dust, Co2, VOC, NH3, H2S, temperature, humidity) nodes and GPS location tracking nodes. Through analysis of the relayed of the environmental monitoring data via gateway, the system makes it possible for constant monitoring and quick response for emergency situation of the burial sites. In order to test the effectiveness of the system, we have installed a set of sensor to gas outlets of the burial sites, then collected and analyzed measured bio-sensing data. We have conducted simulated emergency test runs and was able to detect and monitor the foul smell constantly. With our study, we confirm that the preventive measures and quick response of bio environmental accident are possible with the help of a real-time environmental monitoring system.

Development of Permanent Reference Electrode for Corrosion Monitoring of Underground Metallic Structures (지중 금속구조물 부식감시를 위한 영구매설용 기준전극 개발)

  • Ha, Y.C.;Bae, J.H.;Ha, T.H.;Lee, H.G.;Lee, J.D.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.532-534
    • /
    • 2004
  • The advancement of electronics and telecommunication technologies has forced the risk management system for underground metallic structures to evolve into the remote monitoring and control system. Especially, facilities such as gas pipelines, oil pipelines and water distribution lines might make hazardous effect on human safety without continuous monitoring and control. As a result, pipeline engineers have applied cathodic protection system to prevent the degradation of their facilities by corrosion and carried out a periodic monitoring of the pipe-to-soil (P/S) potentials at numberous test boxes along their pipelines. The latter action on a road in downtowns, however, is so much dangerous that the inspectors should be ready to suffer the threatening of their lives and maintenance. In order to minimize these social costs and hazards, a stand-alone type corrosion monitoring equipment which can be installed in test box, store the P/S data for given Belied and send the data by wired/wireless telecommunications is under development. In order to obtain the exact P/S data, however, a reference electrode should be located as close to the pipeline as possible. Actually, the measured potential by a conventional portable reference electrode contain inevitably an IR drop portion caused by the current flow from the cathodic protection rectifier or the subway railroad. To minimize this error, it is recommended that the reference electrode should be buried within 10 cm from the pipeline. In this paper, we describe the design parameters for fabricating the permanent type reference electrode and the characteristics of the developed reference electrode.

  • PDF

Emission Factor of Hazardous Air Pollutants in Gas-phase from Light Commersial Vehicle using PEMS on Real-road Driving (실도로 주행에서 PEMS를 이용한 소형 경유 상용차의 가스 상 유해대기오염물질 배출계수 연구)

  • Lim, Ji Hye;Han, Sang Woo;Kim, Jeong;Jang, Young Kee;Chon, Mun Soo;Hwang, Sung Chul;Kim, Joung Hwa;Jung, Sung Woon;Kim, Jeong Soo;Han, Jin Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.2
    • /
    • pp.191-206
    • /
    • 2018
  • In this study, the HAPs(Harzard Air Pollutants) emission factor level of Starex and Grand Carnival was tested using PEMS (Portable Emissions Measurement System) on real road driving. As a result of RDE (Real Driving Emission test), the overall vehicle speed pattern showed similar characteristics. The real-road driving test at constant speed revealed emission factor is inversely proportional relationship to constant speed. Results of accelerating with speed limit on the real-road were shown as followings; Uran (less than 45 km/h)>Rural (<45 km/h, less than 80 km/h)>Motorway (>80 km/h). Moreover, the sudden acceleration and deceleration in driving at high speed was the increasing factor to the HAPs emission factor. This tendency is considered to be influenced by the operating environment on real roads.

Development and Ergonomic Evaluation of Spring and Autumn Working Clothes for Livestock Farming Workers

  • Kim, Insoo;Lee, Kyung-Suk;Seo, Min-Tea;Chae, Hye-Seon;Kim, Kyung-Su;Choi, Dong-Phil;Kim, Hyo-Cher
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.5
    • /
    • pp.343-359
    • /
    • 2016
  • Objective:In this study, we designed working clothes for livestock farmers to wear in spring and autumn to improve their work efficiency, conducted a physiological test on their performance, and evaluated their comfort. Background: In recent years, livestock farming in Korea has expanded, yet farmers' safety and sanitation levels remain low in hazardous environments that include organic dust, toxic gas, and heat stress, as well as the risk of accidents. Furthermore, most livestock farmers wear ordinary or dust-resistant clothes that are unsuitable for rearing livestock and compromise their safety and health. Thus, it is important to design specialized working clothes for livestock farmers that are comfortable and that minimize their health and safety risks. Method: To this end, we examined the literature on livestock (poultry, swine, and cattle) farmers' safety and sanitation issues, designed appropriate working clothes, and tested them in terms of sensory feel, physiological response, and subjective comfort. Results: The respondents expressed satisfaction with the new working clothes. The results of a physiological test showed a decline in temperature and humidity inside the clothes, a lower pulse rate, and a lower oxygen intake compared to the measurements taken when famers wore their previous working clothes. This indicates a fall in heat stress and fatigue, which was mostly consistent with the results of the assessment of subjective comfort. Conclusion: The results of the analysis show an improvement in the comfort of the new working clothes compared to the dust-resistant clothes that are widely worn. Based on this study, the new working clothes need to be further tested and evaluated to improve the design. Application: This study is expected to contribute to designing better working clothes for livestock farmers.

Characteristics of a Wet Air Cleaning System for Removal of Air Pollutants (습식 공기청정장치의 공기오염물질 제거 특성)

  • Bae, Gwi-Nam;Kim, Yong Pyo;Baik, Nam Jun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.1
    • /
    • pp.21-31
    • /
    • 2000
  • Performance characteristics of a wet air cleaning system were investigated experimentally, and discussed in relation with physicochemical properties of the target pollutants. The system is composed of an air cleaner, a separator, and a medium filter. Removal efficiency of the system was measured for ambient particles and gaseous air pollutants: $SO_2$, NO, $NO_2$, HCHO, and $NH_3$. For particle removal test, particles were introduced into the system through a fan, and the particle size distribution was measured at three locations by using two laser particle counters. Particle removal efficiency for each system component was obtained from the particle size distribution. It was found that the separator primarily removed coarse particles greater than $5{\mu}m$ in diameter, and that the medium filter mainly removed fine particles less than $5{\mu}m$ in diameter. For gas removal test, air with gaseous air pollutant was injected into the outlet of the fan, and the concentration was measured both at the upstream of the air cleaner and at the downstream of the separator. It was found that the gaseous species with high Henry's law coefficients, such as $SO_2$, HCHO, and $NH_3$, showed high removal efficiency, but the gaseous species with low Henry's law coefficients, such as NO and $NO_2$, showed low removal efficiencies. It was also found that negative ions were generated from the air cleaner.

  • PDF

An Energy Characteristics of Carbonization Residue produced from Sewage Sludge Cake (하수슬러지 케익으로부터 생산한 탄화물의 에너지 특성)

  • Rhee, Seung-Whee
    • Korean Chemical Engineering Research
    • /
    • v.47 no.2
    • /
    • pp.230-236
    • /
    • 2009
  • Sewage sludge cake(SSC) is seriously concerned because ocean dumping, which is the cheapest treatment method now, will be banned in 2012. On the basis of this reason, recycling of SSC is emphasized to convert the treatment method. One of the method to recycling SSC could be carbonization process which also can be reduced greenhouse gas effectively. And carbonization residue of SSC produced by carbonization process can become a renewable energy source. However, carbonization process has not been evaluated by considering basic operating data such as heating value, yield and fuel ratio. In this study, the basic characteristics of SSC such as proximate analysis, elementary analysis and heating value are analyzed. In carbonization process, the effect of carbonization temperature and time on the residue of SSC are estimated. And the analysis is carried out to obtain basic properties of the residue of SSC. From the result of chemical composition of SSC residue, there is 27% of phosphate in SSC. Phosphate will take a role of reductant to convert from hazardous substance to non-hazardous material. As increased carbonization temperature and time, heating value and yield are decreased but fuel ratio(fixed carbon/volatile combustible) of the residue is increased. In the carbonization process, the optimum temperature and time in carbonization test for SSC can be decided by $250^{\circ}C$ and 15 min, respectively. However, the carbonization residue of SSC can not be deserved to use one of renewable energy sources because the heating value at the optimum condition is relatively low. Hence, it is desirable that SSC can be mixed with other organic waste to carbonize.

A Study on the Efficiency Estimation of Halogen free Fire Resistance Cable (저독성 내화전선 케이블의 성능평가에 관한 연구)

  • 윤헌주;홍진웅;유동일;윤재선;곽동일
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.18-23
    • /
    • 2002
  • Efficiency estimation of toxicity free resistance cable experiments were conducts to understand toxicity free fire ersistance polyolefin insulation material and smoke density characteristic and combustion gas corrosion analysis. A main cause of fire-growth and generating toxic gas when it burns, should be dealt with great care in life safety design. Similar patterned fire incidents such as, Inchon Live-Hof Pub Restaurant as, Sea-land Children Resort have proven that serious loss of lives were caused by hazardous gas generated fire resistance cable materials. In this paper, Referenced documents were ASTM E662 standard test method for specific Ds genalated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of 2.5$\pm40.04〔w/$\textrm{cm}^2$〕for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 25.2 to 37.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. Also, the fire gases was occurred carbon monoxide and decomposition than in polyolefin due to incomplete combustion of PVC which has high content of carbon in chemical compound.