• 제목/요약/키워드: Gas flow analysis

검색결과 1,666건 처리시간 0.028초

EFFECT OF THE DIFFERENTIAL PRESSURE BY THE BLOW-BY GAS FLOW ON THE PCV VALVE WITH A CRACK

  • Song, S.M.;Kwon, O.H.;Lee, Y.W.
    • International Journal of Automotive Technology
    • /
    • 제8권2호
    • /
    • pp.219-224
    • /
    • 2007
  • Recently, atmospheric contaminations has become worse due to the increased number of automobile. The PCV (Positive Crankcase Ventilation) valve acts as a flow control to allow re-combustion of blow-by gas by having it flow from a crankcase to an inlet manifold suction tube. Also, during the fabrication of the PCV valve, micro cracks may occur in the valve body and be extended under operation. The excessive stress distribution and crack initiation on the PCV valve body would bring an unstable blow-by gas flow rate control and would cause valve failure. The purpose of this study is to examine the crack affects on the stress and strain variations on the PCV valve according to the inlet and outlet manifold under differential pressures. From the results, we can explain the behavior of the crack extension for a safe condition of PCV valve.

진공상온분사(VKS) 공정에서의 비행입자 가속 기구 및 속도제어를 위한 가스 유량 효과에 관한 연구 (Research on Acceleration Mechanism of Inflight Particle and Gas Flow Effect for the Velocity Control in Vacuum Kinetic Spray Process)

  • 박형권;권주혁;이일주;이창희
    • 한국재료학회지
    • /
    • 제24권2호
    • /
    • pp.98-104
    • /
    • 2014
  • Vacuum kinetic spray(VKS) is a relatively advanced process for fabricating thin/thick and dense ceramic coatings via submicron-sized particle impact at room temperature. However, unfortunately, the particle velocity, which is an important value for investigating the deposition mechanism, has not been clarified yet. Thus, in this research, VKS average particle velocities were derived by numerical analysis method(CFD: computational fluid dynamics) connected with an experimental approach(SCM: slit cell method). When the process gas or powder particles are accelerated by a compressive force generated by gas pressure in kinetic spraying, a tensile force generated by the vacuum in the VKS system accelerates the process gas. As a result, the gas is able to reach supersonic speed even though only 0.6MPa gas pressure is used in VKS. In addition, small size powders can be accelerated up to supersonic velocity by means of the drag-force of the low pressure process gas flow. Furthermore, in this process, the increase of gas flow makes the drag-force stronger and gas distribution more homogenized in the pipe, by which the total particle average velocity becomes higher and the difference between max. and min. particle velocity decreases. Consequently, the control of particle size and gas flow rate are important factors in making the velocity of particles high enough for successful deposition in the VKS system.

셰일가스정 천이유동 생산자료분석의 기술적 고려사항 (Technical Consideration for Production Data Analysis with Transient Flow Data on Shale Gas Well)

  • 한동권;권순일
    • 한국가스학회지
    • /
    • 제20권1호
    • /
    • pp.13-22
    • /
    • 2016
  • 본 연구에서는 다단계 수압파쇄와 수평시추가 적용된 셰일가스정에서 생산자료의 유동형태에 따라 적절한 분석 방법과 궁극가채량을 산출하는 기법을 결정하는 방법을 정리한 흐름도를 제안하였다. 또한 1차 천이유동만이 나타나는 현장자료에 대해 생산천이유동 분석을 수행할 때 고려해야 하는 사항들을 제안하였다. log-log 그래프와 시간제곱근 그래프 분석을 통해 생산자료의 유동 특성을 분류할 수 있고, 이 결과, 1차 천이유동만이 나타나는 생산자료는 이 유동이 종료되는 시점을 정확히 예측하여 이 시점을 기준으로 생산성을 각각 예측하여야 한다. 이 시점은 미세탄성파 탐사자료 해석을 통해 균열자극부피의 면적을 계산함으로써 산출할 수 있다. 공저압력자료나 미세탄성파 탐사자료가 없다면 셰일가스정에 적절한 경험적 방법을 활용하여 생산성을 예측할 수 있다. 생산기간이 짧은 자료는 상대적으로 생산기간이 긴 인접 생산정의 자료를 활용하여 생산기간의 적절성을 평가한 후 필요하다면 생산초기 자료를 제외하고 분석하는 것이 정확도를 향상시킬 수 있다. 또한 미세탄성파 탐사자료 해석에 의해 산출된 SRV는 분석방법이나 분석자의 주관에 의해 과대, 과소 평가될 수 있기 때문에 파쇄 단계, 파쇄유체 주입량, 생산성 분석을 통한 적절성평가를 수행하여 필요한 경우, 저류층 시뮬레이션, 균열모델링, 생산천이분석을 통해 재산정하는 것이 필요하다.

Gas Chromatograph를 이용한 에틸렌 분석 기술 (Procedures for Analyzing Ethylene by Gas Chromatograph)

  • 이승구
    • 한국작물학회지
    • /
    • 제34권s01호
    • /
    • pp.33-39
    • /
    • 1989
  • Ethylene gas classified as one of five major plant hormones plays an important role in various plant metabolism. The precise analysis of ethylene production of plants or plant parts is a valuable research procedure because knowledge of ethylene production facilitates measures of the physiological activity within the tissue. This paper describes procedures for analyzing ethylene from plant tissues by gas chromatography and discusses problems associated with extracting gas samples either by introducing a vacuum to plant samples or by using a hypodermic syringe. Introduced are a continuous flow system for efficient analysis and an automated system for sampling, analyzing, calculating and recording ethylene production data.

  • PDF

OMACON형 LM-MHD 시스템에서의 에너지전환특성 시뮬레이션 (Simulation of Energy Conversion Characteristics of OMACON LM-MHD Systems)

  • 김창녕
    • 한국시뮬레이션학회논문지
    • /
    • 제6권2호
    • /
    • pp.1-14
    • /
    • 1997
  • The characteristics of the flow and energy conversion in OMACON liquid-metal MHD system are investigated. Numerical simulation of two-phase flow in the OMACON system without magnetic field was carried out by the Phoenics code and the energy conversion characteristics are studied in association with the fact that the mechanical energy loss at the nozzle of the OMACON system are to be converted into electrical energy. In this system, working fluid (gas) is injected through the mixer located at the bottom of the riser, and is mixed with hot liquid metal. Therefore in the riser two-phase flow is developed under the influence of the gravity. In this study, the interaction between the gas and liquid is considered by the use of IPSA(InterPhase Slip Algorithm) where standard drag coefficient has been used. It has been assumed that in the flow regime the liquid is continuous and the gas is dispersed. For the liquid and gas, the continuity equations, momentum equations and energy equations are solved respectively in association with void fraction in the flow field. In order to calculate the energy conversion efficiency, firstly the ratio of the mechanical energy loss of liquid metal flow at the nozzle to the input thermal energy is considered. Secondly flow pattern of liquid metal in the generator has been analyzed, and the characteristics of the conversion of the mechanical energy into the electrical energy has been investigated. For an representative case where Hartmann number is 540 and magnetic field is 0.35 T, the present analysis shows that the energy conversion efficiency is 0.653. This result is considered to be reasonable in comparison with published experimental results.

  • PDF

발전용 가스터빈 연소기의 천연가스 연소유동 해석 (Natural Gas Combustion Analysis in Power Generation Gas Turbine)

  • 김태호;최정열
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2005년도 제31회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.156-161
    • /
    • 2005
  • Two and Three dimensional numerical simulations have been carried out to understand the combustion characteristics of LNG-fueled gas turbine combustor for power generation. Focus of the study was given to the influences of different fuel composition of imported and domestic natural gases with the flow conditions selected from the gas turbine operation data. Reacting flow characteristics of the swirl stabilized natural gas combustor were understood from the comparison of the two-dimensional and three-dimensional results. The thermal influences of different natural gases were very small and the fuel composition and flow rate were considered to be tuned well.

  • PDF

발전용 희박예혼합 가스터빈 연소기 내부유동 특성 해석 (A Numerical Analysis of the Flow Characteristics in a Lean Premixed Gas Turbine Combustor for Power Generation)

  • 정재화;서석빈;안달홍;김종진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.847-852
    • /
    • 2000
  • Three dimensional CFD investigations are carried out to understand the complex flow field in a gas turbine combustor with multi-element fuel injectors. The gas turbine considered here is the GE7FA model which has aye fuel injectors in each combustor can and utilizes lean-premixed combustion to meet nitric oxide emission requirements. Detailed three-dimensional flow characteristics and fuel-air mixture formation process inside the fuel nozzle and gas turbine combustor including five swirl nozzle tips are analyzed using commercial FLUENT code.

  • PDF

유동 해석을 이용한 평판형 고체 산화물 연료전지의 성능 특성 분석 (I) - 등온 모델 - (Performance Predictions of the Planar-type Solid Oxide Fuel Cell with Computational Flow Analysis (I) - Isothermal Model -)

  • 현희철;손정락;이준식;노승탁
    • 대한기계학회논문집B
    • /
    • 제27권5호
    • /
    • pp.635-643
    • /
    • 2003
  • Parametric study for the analysis of performance characteristics of a planar -type solid oxide fuel cell(SOFC) using computational flow analysis is conducted. A planar -type SOFC, which is composed by two gas channels (fuel and ai.) and one set of anode-electrolyte-cathode assembly, is modeled as a two -dimensional isothermal case. Results of computational analysis of flow field including distributions of mass fractions in gas channels are used to the performance analysis of the fuel cell. Flow analysis makes it possible to consider current density distributions along the length of the cell in the process of performance analysis of the SOFC. As results of parametric study, it is found that the mole fraction of fuel at the inlet of fuel channel, operating pressure and temperature are closely related to the performance characteristics of SOFC.

Analysis of SLF Interruption Performance of Self-Blast Circuit Breaker by Means of CFD Calculation

  • Kim, Hong-Kyu;Chong, Jin-Kyo;Lee, Se-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.254-258
    • /
    • 2014
  • This paper presents the performance analysis results of a short line fault interruption of a gas circuit breaker, particularly a self-blast type breaker. Hot gas flow analysis was carried out using a CFD calculation combined with the arc model and nozzle ablation model. To evaluate the interruption performance, the index function was defined using the pressure in the heating chamber and the density above the arc region. The simulation and test results showed that the gas flow field and suitable choice of an interruption performance index can be used to predict the interruption characteristics and provide guidelines for designing self-blast breakers with a higher interruption capability.

간접 내부 개질형 용융탄산염 연료전지 anode 채널에서의 압력 강하 및 온도 조건 변경에 따른 유량 균일도에 관한 수치 해석적 연구 (Numerical analysis of the gas flow-rate uniformity in the anode flow channel of indirect internal reforming molten carbonate fuel cell (MCFC) under different pressure drop and temperature conditions)

  • 조준현;하태훈;김한상;민경덕;박종훈;장인갑;이태원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.127-130
    • /
    • 2009
  • The uniform gas distribution between anode channels of the indirect internal reforming type molten carbonate fuel cell (MCFC) is crucial design parameter because of the electric performance and the durability problems. A three-dimensional computational fluid dynamics (CFD) analysis is performed to investigate flow characteristics in the anode channels and manifold under different pressure drop and channel temperature conditions. The combined meshes consists of hexadral meshes in the channels and polyhedral meshes in the manifold are adopted and chemical reactions inside the MCFC system are not included because of computational difficulties associated with the size and geometric complexity of the system. Results indicate that the uniformity in flow-rate is in the range of $\pm$ 0.048 % between the anode channels when the pressure drop of anode channel is about 150 Pa. A gas flow-rate uniformity decreases as the pressure drop of anode channels decreases and as the temperature difference between indirect internal reforming (IIR) channels and anode channels increases.

  • PDF