• Title/Summary/Keyword: Gas exchange

Search Result 648, Processing Time 0.035 seconds

Adsorption Properties of SO$_2$ Using Fibrous Strong-base Anionic ion Exchange Scrubber (강염기성 음이온교환 섬유 스크러버를 이용한 SO$_2$의 흡착특성)

  • 황택성;최재은;강경석
    • Polymer(Korea)
    • /
    • v.26 no.5
    • /
    • pp.661-669
    • /
    • 2002
  • The purpose of this research is to absorb and remove sulfur dioxide existing in the air by using ion exchange non-woven fabric. So we found out very appropriate condition of anionic exchange fabric scrubber by measuring amount of SO$_2$ adsorption under the atmosphere that concentration, velocity, and humidity was 100∼200 ppm, 0.6∼1.0 m/sec, and 30∼90 RH%, respectively. Ion exchange capacity of ion exchanger showed the maximum value, 3.75 meq/g at pH 4, and adsorption equilibrium time was the maximum value, 30 h when gas velocity was 0.6 m/sec, moreover, at 80$\^{C}$, adsorption equilibrium time tended to decrease more than 10 h. When concentration was 200 ppm, while reaction speed between SO$_2$ and ligand of fibrous ion exchanger was getting faster, adsorption break point had a tendency to get faster as well. In addition, when relative humidity in the scrubber was 90%, adsorption efficiency was 7.6%/h that seemed to be 30% higher than 4.6%/h coming from the condition that relative humidity had been 30%, and it was totally absorbed under 5 wt% NaOH solution in 5 minutes.

Occurrence of Saprolegnia diclina Associated with Fungal Gill disease at snake fishes Culture farm (가물치 양식어장(養殖漁場)에서 진균성새병(眞菌性鰓病)과 관련된 Saprolegnia diclina의 발생상황(發生狀況))

  • Min, Hong-Kyu;Chun, Soon-Bai;Bai, Suk
    • Journal of fish pathology
    • /
    • v.4 no.2
    • /
    • pp.95-100
    • /
    • 1991
  • Saprolegnia diclina, which was the pathogen causing death in snake fishes(Channa argus) at culture farm, was investigated using scanning electron microscope. It was found that Saprolegnia diclina infection caused snake fishes to fail gas change in the gills. Cell lysis as well as edematous disease and hyperplasia as a result of Saprolegnea diclina attachment on the surface of gills were observed. The granules, the mean diameters of which ranged from 6 to $7\;{\mu}m$, attaching on the surface of gills were found to be secondary zoospores of Saprolegnia diclina. The failures of gas exchange in the gill cells and circulation as a result of the osmotic dilution of the blood were supposed to be the main cause of death.

  • PDF

Modeling of Water Transport in Porous Membrane for PEMFC Humidifer (PEMFC 가습기 용 다공성 중공사막의 물전달 모델링)

  • Hwang, Jun Y.;Park, J.Y.;Kang, K.;Kim, J.H.;Kim, K.J.;Lee, M.S.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.96.2-96.2
    • /
    • 2011
  • Water transport through the microporous membrane was modeled considering capillary condensation as well as capillary flow in porous media as a function of pore diameter and relative humidity at the surface. The present model was adopted by the numerical simulation of non-isothermal, non-homogenous flow in a shell and tube typed gas to gas membrane humidifier for PEMFC (proton exchange membrane fuel cell) and the result shows good agreement with experimental data.

  • PDF

A Numerical Study on Fuel Concentration Distribution in a FBC (유동층 연소로내 연료농도분포의 수치적 연구)

  • Lee, D.I;Park, S.H.;Shin, D.S.
    • Journal of the Korean Society of Combustion
    • /
    • v.3 no.1
    • /
    • pp.41-48
    • /
    • 1998
  • A numerical study on combustion in a fluidized bed is based on three dimensional mixing and dispersion phenomena in the bed owing to the bubble growth in the vertical direction. As fluidizing velocities increase, bubble diameters increase, which activates the fuel dispersion in the bed. The combustion rates, however, reduce due to the decrease of gas exchange rates between bubble and emulsion phases. Fuel distributions in the bed are dependent on fluidizing velocities, equivalence ratios, fuel particle diameters, fuel feeding points, and the number of fuel feeders.

  • PDF

A Study on the Design of High-Frequency Jet Ventilator Using PLL system (위상동기루프 방식을 이용한 고빈도 JET환기장치의 설계에 관한 연구)

  • Lee, Joon-Ha;Chung, Jae-Chun
    • Journal of Yeungnam Medical Science
    • /
    • v.6 no.2
    • /
    • pp.63-70
    • /
    • 1989
  • This paper describes to design and to examine the mechanical characteristics of high frequency jet ventilator. The device consists of Phase lock loop(PLL) system, solenoid valve driving control part and Air regulating system. This study is carried out by changing several factors such as endotracheal tube(E.T. tube)diameter, injector cannula diameter, 1%, and frequency(breaths/mim.) having direct effects on the gas exchange as well as parameters of the entrained gas by venturi effects, so as to measure the tidal volume and minute volume. This system characteristics were as follows : 1) Frequency : 6-594bpm 2) Inspiration time : 1-99% 3) Variance of input air pressure : 1-30PSI.

  • PDF

The Effect of Operating Conditions on the Heat-flow Characteristics and Reforming Efficiency of Steam Reformer with Combustor (연소기가 장착된 수증기 개질기에서 운전조건이 열유동 특성 및 개질효율에 미치는 영향)

  • Kim, Ji-Seok;Lee, Jae-Seong;Kim, Ho-Young
    • Journal of the Korean Society of Combustion
    • /
    • v.16 no.1
    • /
    • pp.36-45
    • /
    • 2011
  • The heat-flow characteristics and reforming efficiency of steam reformer with combustor are numerically investigated at various operating conditions. SCR(Steam to Carbon Ratio) and GHSV(Gas Hourly Space Velocity) are adopted as important operating conditions. User-Defined-Function(UDF) was used to simultaneously calculate reforming and combustion reaction. Numerical results show that hot burned gas rise by a buoyant force and heat exchange between reforming reactors and cocurrent flow occurs in the combustion region. The results also indicate that an increase of SCR leads to decrease the mole fraction of hydrogen at the reactor outlet. As GHSV increases, conversion rate decreases.

Fabricability of Reaction-sintered SiC for Ceramic Heat Exchanger Operated in a Severe Environment (원자력 극한환경용 세라믹 열교환기 소재로서 반응소결 SiC 세라믹스 제작성)

  • Jung, Choong-Hwan;Park, Ji-Yeon
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.1
    • /
    • pp.52-56
    • /
    • 2011
  • Silicon carbide (SiC) is a candidate material for heat exchangers for VHTR (Very High Temperature Gas Cooled Reactor) due to its refractory nature and high thermal conductivity. This research has focused on demonstration of physical properties and mock-up fabrication for the future heat exchange applications. It was found that the SiC-based components can be applied for process heat exchanger (PHE) and intermediate heat exchanger (IHX), which are operated at $400{\sim}1000^{\circ}C$, based on our examination for the following aspects: optimum fabrication technologies (design, machining and bonding) for compact design, thermal conductivity, corrosion resistance in sulfuric acid environment at high temperature, and simulation results on heat transferring and thermal stress distribution of heat exchanger mock-up.

Dry-out conditions of free-breathing PEMFC with dry $H_2$ gas (자연급기 무가습 연료전지의 Dry-out조건)

  • Park, Sang-Kyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.225-230
    • /
    • 2006
  • This study investigates drying condition when a small fan is added to a operating the free-breathing proton exchange membrane fuel cells (PEMFCs) with dry $H_2$ and Air. Polarization tests were conducted on PEMFCs at cell temperatures between 30 and $50^{\circ}C$ under dry operation. In the results, the cell performance strongly depended on the cell temperature and the cathode gas stoichiometric flow rates. The cell performance increases as cell temperature decreases from 50 to $30^{\circ}C$. In the domain where the stoichiometry of air is quite large, reduction of the concentration overpotential compensated the increased internal resistance due to drying. The maximum performance was obtained at the small air flow rate beyond which flooding occurs. This indicates that the fan should be operated in the stoichiometry domain with a well designed cell structure to avoid flooding.

The effects of gas flow in intake and exhaust system on volumetric efficiency (흡배기계의 가스유동이 체적효율에 미치는 영향)

  • 조진호;김병수
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.57-65
    • /
    • 1988
  • The study of unsteady gas exchange processes in the intake and exhaust systems of four-cylinder, four-stroke cycle internal combustion engine is described in this paper. The calculation model for the intake and exhaust systems is established and solved by the characteristic method for the equations defining these systems. A constant pressure theory is used for modeling branches of intake and exhaust manifolds. The relationship between the volumetric efficiency and the intake, exhaust pressure variation is clarified by simulation of these systems. It is found that the volumetric efficiency mainly depends on the intake pressure during the short period before the intake valves is closed, that the volumetric efficiency is influenced a little by intake chamber volume in the intake and exhaust system.

  • PDF

High Frequency Jet Ventilation via Cricothyroid Membrane Puncture under Microlaryngoscopic Surgery (미세 후두현미경술시 윤상갑상막천자를 통한 고빈도 제트환기법)

  • 양훈식;김용주;김춘길
    • Korean Journal of Bronchoesophagology
    • /
    • v.1 no.1
    • /
    • pp.109-115
    • /
    • 1995
  • High frequency Jet ventilation (HFJV) via cricothyroid membrane puncture contols frequency of ventilation as 20-200/min and persuits adequate gas exchange. HFJV was known to have advantages such as improvement of PaO$_2$, lesser barotrauma, stable hemodynamic effects, good operative field and lesser movement of head. The purpose of this study was to clarify the advantages of HFJV in cases of microlaryngeal surgery which operating time was expected even within 30 minutes. Twenty-eight patients were divided two groups : 1)control group : general endotracheal Intubation anesthesia. 2)experimental group : HFJV via cricothyroid membrane puncture with intravenous anesthesia, frequency 40/min, I/E ratio 40%, driving pressure 40 psi. We analyzed blood pressure, arterial blood gas, score of general condition and recovery time after operation. In conclusion, HFJV via cricothyroid membrane puncture had a good score of general condition and rapid recovery of consciousness, although some accumulation of P$CO_2$and elevation of blood pressure.

  • PDF