• Title/Summary/Keyword: Gas discharges

Search Result 119, Processing Time 0.03 seconds

Optimal Design of the Safety Valve by Response Surface Method (반응표면법을 이용한 안전밸브의 최적화)

  • Lee, Sang-Woo;Shin, Dae-Young;Byun, Cheol-Woong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.5
    • /
    • pp.551-556
    • /
    • 2007
  • High pressure storage of the agent gas in fire suppression system was composed of tank, main valve and safety valve, which prevents the fracture of the high pressure storage. The safety valve has circular thin plate as fracture plate that was destroyed over fracture pressure. When inner pressure of the storage is reached the fracture pressure, the safety valve discharges gas and degrades simultaneously the inner pressure of the storage. There are design variables such as flow path diameter, inner diameter of the plastic packing ring, thickness of plate and fillet radius. In this variables, thickness of plate is set to be a value of 0.2mm. The main effect of variables on the inner pressure, has been decided using factorial design and statistical analysis. Therefore, the relation of variables are expressed by regression equation. It is disclosed results that the difference of fracture pressures between the equation and experiment has $2{\sim}5%$. Finally, using response surface method, the optimal design of the safety valve could be decided with safety pressure of 25MPa, where the fracture occurs on circular thin plate.

Outbreaks of Strangles due to Capnophilic Streptococcus equi subsp equi in South Korea (호이산화탄소성 Streptococcus equi subspecies equi에 의한 선역의 발생)

  • Moon, Ja-Ho;Kim, Jeong-Hee;Takai, Shinji;Son, Won-Geun
    • Journal of Veterinary Clinics
    • /
    • v.32 no.1
    • /
    • pp.41-44
    • /
    • 2015
  • We reported an outbreak of clinical strangles in thoroughbred horses due to capnophilic Streptococcus equi subsp equi in South Korea. On three different farms, we isolated 17 S equi subsp equi isolates from 29 horses with or without abscesses in their lymph nodes. Of the 17 isolates, two isolates from clinical cases grew well in aerobic conditions, whereas 7/7 isolates from clinical cases and 8/22 isolates from the nasal discharges of horses did not. The latter 15 isolates were capnophilic, oxygen-sensitive, and $CO_2$-requiring S equi subsp equi, which could not grow in aerobic conditions, but which grew well in a $CO_2$ incubator with 5% $CO_2$, in anaerobic conditions using a GasPak, and with reduced oxygen tension in a candle jar. This study is the first report of a strangles outbreak caused by capnophilic S equi subsp equi in South Korea.

Fabrication and Characteristics of X-ray Position Detection Sensor (방사선 위치 검출센서의 제작 및 특성)

  • Park, Hyung-Jun;Kim, In-Su
    • Journal of IKEEE
    • /
    • v.19 no.4
    • /
    • pp.535-540
    • /
    • 2015
  • A microstrip gas chamber (MSGC), applied to digital radiography system, was designed and constructed. The microstrip electrodes were fabricated with Chrome(Cr.). by photolithography process on Silicon(Si) wafer and glass substrate. The width of anode and cathode electrodes was $10{\mu}m$, and $290{\mu}m$, respectively. The distance of the electrodes was $100{\mu}m$, and the active area was $50{\times}50mm^2$. And the number of anode was 80. The microstrip electrodes were damaged when discharges occurred over the 600 V of anode voltage. As the result of experiments. It detected the typical output signals of the pulse width, 20 ns, under the condition that the detecting gas was Ar(90%) + $CH_4$(10%), X-ray tube voltage was 42 kV, and tube current was 1 mA.

High Efficacy AC-PDP toward 10 lm/W

  • Choi, Kyung-Cheol;Lee, Seung-Tae;Shin, Nam-Hoon;Lee, Seong-Min;Song, Sang-Cheol;Yun, Jin-Bhum;Shin, Bhum-Jae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.7-12
    • /
    • 2006
  • The high efficacy concept, featuring in this study an auxiliary electrode and a 200 ${\mu}m$ coplanar gap, is applied to AC-PDPs with a stripe - type and a closed - type barrier rib, respectively. The roles of the pulses applied to the auxiliary electrode create additional excitation during the sustain period and reduce a discharge current that flows into the display cells. The efficacy of the proposed panel with the closed barrier rib has maximum values when the auxiliary pulse voltage is 50 volts and 80 volts for the Ne+4%Xe and Ne+20%Xe gas-mixtures, respectively. The maximum luminous efficacy is more than 10 lm/W in terms of the measurement of the discharges in VGA resolution ($540{\mu}m{\times}720{\mu}m$) and the green cells.

  • PDF

Effects of Neon Plasma Emission on Optical Properties of Phosphor Layers in Surface-Type Alternate Current Plasma Display Panel

  • Jang, Sang-Hun;Cho, Ki-Duck;Tae, Heung-Sik;Park, Lee-Soon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.171-174
    • /
    • 2000
  • This study uses neon and xenon gas mixture discharges to determine the effects of the neon plasma emission on the characteristics of visible emission from the stimulation of the red, green, blue(RGB) phosphor layers in a surface-type alternate current plasma display panel(AC PDP). With a mixture of less than 2% xenon to neon, it is found that the luminance changes in the visible emission of the phosphor layers are similar to those of the neon plasma emission. In the range of xenon mix ratio from 2 to 5%, the luminance of the red, green, blue(RGB) phosphor layers decreases with a decrease in the neon plasma emission intensity. However, with a mixture of above 5% xenon to neon, the luminance of the red, green, blue(RGB) phosphor layers increases regardless of a decrease in the neon plasma emission intensity. Furthermore, the color purity of the red, green, blue(RGB) phosphor layers improve as the neon plasma emission intensity decreases. Accordingly, it is concluded that the optical properties of the phosphor layers, including color purity and luminance, depend on the neon plasma discharge emission as well as the visible emission from the stimulation of the phosphor layers.

  • PDF

Control Method for DACS with Variable Burning Area (가변 연소면적 DACS의 압력 제어 기법)

  • Ki, Taeseok;Park, Iksoo;Heo, Jun-Young;Jin, Jungkun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.368-373
    • /
    • 2017
  • Control method for DACS with variable burning area is designed and the performance of the control method is analyzed by doing simulation at various conditions. DACS, which got solid propellant on board, is designed as end-burning type typically. End-burning type DACS has the merit of controlling pressure and thrust, but it discharges the combustion gas which does not using for getting thrust. Therefore, optimal design of propellant grain and burning area changes over time as a result. Variable burning area can be assumed as a disturbance and adaptive control method is useful for pressure control of DACS effected by disturbance.

  • PDF

High Performance AC-PDP Sustain Driver with Low switching Loss (낮은 스위칭 손실을 가지는 고성능 AC-PDP 구동 회로에 관한 연구)

  • Kang, Feel-Soon;Park, Sung-Jun;Park, Han-Woong;Kim, Cheul-U
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.50-56
    • /
    • 2002
  • When the plasma panel is used as a display, frequent discharging are made to occur by alternatively charging each side of the panel to a critical voltage, which causes repeated gas discharges to occur. In this paper, an efficient sustain driver is proposed to achieve a faster rise-time in order to be suitable to widely used ADS driving method. The proposed circuit increases an operational margin up to 20 % compared with conventional approaches improving the recovery efficiency regardless of the variation of panel capacitance. Thanks to the increased operational margin, the brightness decrease problem can be solved without a limitation to sustain pulse width. The principle of operation, and features are illustrated, and verified on a 7.5 inch diagonal panel at 200 kHz operating frequency - based on experimental prototype.

  • PDF

Discrimination of insulation defects in a Gas Insulated Switchgear (GIS) by use of a neural network based on a Chaos Analysis of Partial Discharge(CAPD) (카오스이론을 이용한 GIS 내부 절연결함 판별)

  • Lim, Yun-Seok;Lee, Dong-Il;Koo, Ja-Yoon;Kim, Jeong-Tae;Bang, Hang-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2223-2225
    • /
    • 2005
  • In this work, experimental investigation has been mainly done. For this purpose, UHF sensor has been designed and fabricated to detect the partial discharges produced from the 10 artificial defects introduced into the real scale 70kV GIS mock-up under the high voltage at the well shielded room. And also, in order to verify the applicability of the proposed method at the site, the proposed CAPD (chaos analysis of partial discharge) is combined with spectral analysis method in order to identify the nature of the above 10 defects. The PD pattern recognition of each defect has been fulfilled by applying self developed artificial neural network soft ware. The result shows that the recognition rate is reached to be 80% by newly proposed method while the traditional PRPD analysis method leads us to obtain 41%. In consequence, it can be pointed out that the proposed method seems likely to be applicable to the real GIS at the site.

  • PDF

A study on the UHF PD measuring technique for GIS with a metal flange around insulating spacer (스페이서에 Metal flange가 있는 GIS에서의 UHF PD 측정 기술 연구)

  • Kang, W.J.;Lee, C.J.;Kang, Y.S.;Park, J.B.;Lee, H.C.;Park, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1638-1640
    • /
    • 2003
  • In the recent years, UHF PD measuring technique for detecting partial discharges was proved the effective method for Gas Insulated Switchgear (GIS). However, in case of GIS with a metal flange around insulating spacer, UHF PD measurement using typical external UHF PD sensor is difficult. In this paper, a novel hole-type UHF PD sensor based on Archimedean spiral antenna theory has been proposed and realized. All spacers with metal flange have small hole in order to inject epoxy. Using the novel hole-type UHF PD sensor, it makes detection possible to PD signal that are emitted through the epoxy injection hole. Additionally, the measuring characteristic of UHF PD signals from several artificial defects in GIS and the novel ${\Phi}$-f-q pattern analysis technology are discussed.

  • PDF

Trend in Off-Line PD Monitoring with HVAC Testing (배전반 설비의 온라인 모니터링 및 진단의 동향)

  • Yun, Ju-Ho;Hong, Chang-Il;Hwang, Jong-Sun;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.529-530
    • /
    • 2007
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF