• 제목/요약/키워드: Gas discharge

검색결과 1,513건 처리시간 0.031초

에어커튼형 레인지후드의 슬롯 토출 각도 변화와 배기 효율 (Effect of Slot Discharge-Angle Change on Exhaust Efficiency of Range Hood System with Air Curtain)

  • 성순경
    • 설비공학논문집
    • /
    • 제27권9호
    • /
    • pp.468-474
    • /
    • 2015
  • When oil is used for cooking in detached or apartment houses, large amounts of oil-mist, smoke, and particulate substances are generated and dispersed into the indoor-air environment. These pollutants diffuse into the surroundings and spread their odor while rising fast at a high temperature due to the heat energy from the gas range. Although the exhaust gas is discharged from the exhaust hood, which is installed on the top of a gas range to remove the diffuse pollutants, the exhaust conditions can vary greatly because they depend on the shape of the exhaust hood and the discharge rate. In this paper, the air that is required for the gas-exhaustion process is supplied by an air curtain that surrounds the kitchen hood, and the pollutant-capturing efficiency varies depending on the angle of the discharge grills; the pollutant-capturing efficiency was studied using a numerical-analysis method. The results indicate that the pollutant-capturing efficiency is not significantly changed by a change of the discharge-grill angle at a low air-discharge rate; however, at a high air-discharge rate, the efficiency value increases with an increase of the discharge-grill angle, whereby the best value occurs at 30 degrees and the efficiency decreases above this angle. Below 30 degrees, the effect of the discharge rate on the capturing efficiency is more than that of the discharge-grill angle.

불평등전장에서 $SF_6$ 기체의 뇌임펄스 절연파괴특성 (Characteristics of lightning impulse breakdowns in inhomogeneous $SF_6$ gas gap)

  • 이복희;최휘성;오성균;이봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1921-1923
    • /
    • 2004
  • V-p characteristics and the discharge luminous characteristics in inhomogeneous $SF_6$ gas gap under the positive and negative lightning impulse voltages are presented. The test gap was composed of the plane-to-plane with a needle-shaped protrusion. The applied voltage and the predischarge current were measured by the electric field sensor and the shunt of 50 ${\Omega}$, respectively. The light emission signals were observed by a photomultiplier tube, and a high-speed camera. In a consequence, the dielectric strengths of $SF_6$ gas gap under positive lightning impulse voltages were independent of the gas pressure. In the presence of the positive polarity, the branches of discharge channel were created and the directions of the discharge paths were random. On the other hands, the discharge paths of the negative polarity were more thicker and brighter.

  • PDF

침출수 무배출식 모형매립조를 이용한 도시폐기물 분해특성 (Decomposition Characteristics of Municipal Solid Wastes in Lysimeter Without Leachate Discharge)

  • 류돈식;이해승;이찬기
    • 환경위생공학
    • /
    • 제15권2호
    • /
    • pp.49-57
    • /
    • 2000
  • The objective of this study is to find solid waste decomposition in landfill without leachate discharge. This study was observed variation of landfill gas production rate and leachate for stabilization assessment, and using four sets of lysimeter as experimental apparatus. Soild waste decomposition was accelerated in without leachate discharge system by sufficient moisture for methane bacteria. And gas production rate was between 54.2ℓ/kg VS∼335.9ℓ/kg VS in each lysimeter. Generation time of methane gas was showed different in each lysimeter, but it was much faster than literature research. The time of stabilization phase were began as follows : L-1 400 day, L-2 350 day, L-3 170 day and L-4 70 day respectively. Decreasing times of BOD/COD ratio and C/N ratio were necessary more than literature research because organic matter was not discharge such as wash out.

  • PDF

Xe 가스 첨가에 따른 방전 특성 시뮬레이션 분석 (A Simulation Analysis of the Discharge Characteristics with the Xe Gas Contents)

  • 유일;손영주;이영민;옥정우;남춘우;이돈규
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1650-1655
    • /
    • 2012
  • AC-PDPs have recently achieved good performance and their image quality can sufficiently compete with the LCD TV. However, it is necessary more effort to improve the luminance and luminous efficacy in the PDP technology. The gas mixture ratio plays a very important role in discharge characteristics, but the mechanism of gas discharge is complex and complicated. In this paper, we investigate the mechanism of gas discharge with Ne+Xe miture ratio through zero and two dimensional fluid simulation.

열펌프 압축기의 내부 액분사 효과에 대한 수치해석적 연구 (A Numerical Study of Liquid Injection into the Compressor Cylinder of a Heat Pump)

  • 허재경;방광현
    • 설비공학논문집
    • /
    • 제15권5호
    • /
    • pp.397-405
    • /
    • 2003
  • Heat and fluid flow in a compressor into which liquid refrigerant is injected for the purpose of reducing discharge gas temperature in a heat pump system has been numerically studied. A mechanistic approach encompassing liquid jet breakup and droplet evaporation has been performed to investigate the effects of liquid injection on the spacial and temporal variation of the gas temperature and pressure inside the compressor cylinder. Various parameters, such as liquid injection mass, time, duration and droplet size, are considered in the present study to elucidate the flow field inside the compressor. As the injection mass is increased, discharge gas temperature is decreased, while the pressure is increased due to the added mass of the injection. For the injected liquid mass corresponding to 15% of the total vapor mass in the cylinder, the discharge gas temperature drops by 22.4 K. It is observed that the droplet size plays a major role in the evaporation rate of the droplets that determines the degree of the discharge temperature drop.

실제기체 효과를 고려한 수소기체의 임계노즐 유동에 관한 연구 (Study on the Critical Nozzle Flow of Hydrogen Gas with Real Gas Effects)

  • 김재형;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3003-3008
    • /
    • 2007
  • Critical nozzle has been frequently employed to measure the flow rate of various gases, but hydrogen gas, especially being at high-pressure condition, was not nearly dealt with the critical nozzle due to treatment danger. According to a few experimental data obtained recently, it was reported that the discharge coefficient of hydrogen gas through the critical nozzle exceeds unity in a specific range of Reynolds number. No detailed explanation on such an unreasonable value was made, but it was vaguely inferred as real gas effects. For the purpose of practical use of high-pressure hydrogen gas, systematic research is required to clarify the critical nozzle flow of high-pressure hydrogen gas. In the present study, a computational fluid dynamics(CFD) method has been applied to predict the critical nozzle flow of high-pressure hydrogen gas. Redlich-Kwong equation of state that take account for the forces and volume of molecules of hydrogen gas were incorporated into the axisymmetric, compressible Navier-Stokes equations. A fully implicit finite volume scheme was used to numerically solve the governing equations. The computational results were validated with some experimental data available. The results show that the coefficient of discharge coefficient is mainly influenced by the compressibility factor and the specific heat ratio, which appear more remarkable as the inlet total pressure of hydrogen gas increases.

  • PDF

고압수소 유량계측용 임계노즐 유동의 수치해석적 연구 (A Computational Work of Critical Nozzle Flow for High-Pressure Hydrogen Gas Mass Flow Measurement)

  • 이준희;김희동;박경암
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.227-230
    • /
    • 2006
  • The method of mass flow rate measurement using a critical nozzle is well established in the flow satisfying ideal gas law. However, in the case of measuring high-pressure gas flow, the current method shows invalid discharge coefficient because the flow does not follow ideal gas law. Therefore an appropriate equation of state considering real gas effects should be applied into the method. The present computational study has been performed to give an understanding of the physics of a critical nozzle flow for high-pressure hydrogen gas and find a way for the exact mass flow prediction. The two-dimensional, axisymmetric, compressible Navier-Stokes equations are computed using a fully implicit finite volume method. The real gas effects are considered in the calculation of discharge coefficient as well as in the computation. The computational results are compared with the previous experimental data and predict well the measured mass flow rates. It has been found that the discharge coefficient for high-pressure hydrogen gas can be corrected properly adopting the real gas effects.

  • PDF

수처리용 유전체장벽 플라즈마 반응기에 대한 기초 연구 (A Basic Study of Plasma Reactor of Dielectric Barrier Discharge for the Water Treatment)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제20권5호
    • /
    • pp.623-630
    • /
    • 2011
  • This study investigated the degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical) by using dielectric barrier discharge (DBD) plasma. The DBD plasma reactor of this study consisted of a quartz dielectric tube, titanium discharge (inner) and ground (outer) electrode. The effect of shape (rod, spring and pipe) of ground electrode, diameter (9~30 mm) of ground electrode of spring shape and inside diameter (4~13 mm) of quartz tube, electrode diameter (1~4 mm), electrode materials (SUS, Ti, iron, Cu and W), height difference of discharge and ground electrode (1~15.5 cm) and gas flow rate (1~7 L/min) were evaluated. The experimental results showed that shape of ground electrode and materials of ground and discharge electrode were not influenced the RNO degradation. The thinner the diameter of discharge and ground electrode, the higher RNO degradation rate observed. The effect of height gap of discharge between ground electrode on RNO degradation was not high within the experimented value. Among the experimented parameters, inside diameter of quartz tube and gas flow rate were most important parameters which are influenced the decomposition of RNO. Optimum inside diameter of quartz tube and gas flow rate were 7 mm and 4 L/min, respectively.

플라즈마 방전 클러스터를 이용한 플렉시블 백라이트 유닛 연구 (A Study of Flexible BLU Using Plasma Discharge Ouster)

  • 유시홍;구교욱;이성의
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.324-325
    • /
    • 2008
  • In this Study, We fabricated a plasma discharge cluster with external electrodes which can be applied to flexible backlight in a polymer substrate and investigated the discharge characteristics. The Sealing process was progressed in vacuum chamber, which enable to fabricate plasma discharge cluster. The results of discharge characteristics show that the static memory margin of plasma discharge cluster was increased, as Ne/Xe(5%) gas pressure was increased. also, When gas pressure was 100torr at 600um of electrode gap, we have obtained high luminance of a plasma discharge cluster.

  • PDF

AC-PDP의 방전갭과 가스압력에 따른 Xe-Kr-Ne mixture gas 방전특성 연구 (A research on the discharge characteristics of Xe-Kr-Ne mixture gas in discharge gap and gas pressure of ac-PDP)

  • 한문기;하창승;이돈규;이해준;이호준;박정후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.171-172
    • /
    • 2007
  • PDP의 luminous efficacy의 향상을 위해서는 동작가스의 연구가 매우 중요하다. 본 논문에서는 bolsig simulator를 사용하여 여러 비율의 Xe+Kr+Ne 3원가스 시뮬레이션을 통하여 각 가스입자들에 전달되는 이온화에너지, 여기에너지를 조사하였다. 실험에서 short discharge gap과 long discharge gap을 가진 7인치 테스트 패널 2개를 사용하여 가스압력과 Xe+Kr+Ne 혼합비를 변화시켜가며 discharge voltage, luminance, luminous efficacy를 측정하여, 방전특성을 연구하였다.

  • PDF