• Title/Summary/Keyword: Gas diagnosis

Search Result 392, Processing Time 0.023 seconds

Radiation Shielding to Minimize Image Information Loss (영상 정보 손실을 최소화하는 방사선 차폐체 연구)

  • Su-han Jang;Sang-Hyeun Park;Myeong-Sik Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.449-457
    • /
    • 2023
  • Shielding for reducing exposure dose can make the diagnosis limited. The purpose of this study is to increase the efficiency of radiation protection and minimize the loss of image information by producing the shielding made of the water and the contrast medium which has different proportion and finding out the ideal proportion of them. Each shielding materials were made of water and water-soluble iodine contrast medium with the different proportion. The attenuation rate of absorbed dose was evaluated by the shielding materials in the plastic contents for measuring the efficiency of the radiation protection. As a result, the higher ratio of the contrast medium, the more efficient it is for radiation attenuation. The anatomical structure was observed most properly in case of the solution with 20 ml of the contrast medium and most difficultly in case of more than 60 ml of the contrast medium. In case of the signal intensity between skeleton and gas, the difference of average value had a significant as p < 0.001. Shielding with contrast medium attenuates less than the conventional shielding but in the examination for the sensitive part to radiation, it can be used to minimize the loss of the image information and reduce the exposure dose.

Diagnostic Accuracy and Safety of Medical Thoracoscopy (내과적 흉강경 검사의 진단적 유용성과 안전성)

  • Yang, Jung Kyung;Lee, Jung-Ho;Kwon, Mi-Hye;Jeong, Ji Hyun;Lee, Go Eun;Cho, Hyun Min;Kim, Young Jin;Jung, Sung Mee;Choi, Eu Gene;Son, Ji Woong;Na, Moon Jun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.3
    • /
    • pp.261-267
    • /
    • 2007
  • Background: The causes of the pleural effusion are remained unclear in a the substantial number of patients with exudative effusions determined by an examination of the fluid obtained via thoracentesis. Among the various tools for diagnosing exudative pleural effusions, thoracoscopy has a high diagnostic yield for cancer and tuberculosis. Medical thoracoscopy can also be carried out under local anesthesia with mild sedation. The aim of this study was to determine diagnostic accuracy and safety of medical thoracoscopy. Methods: Twenty-five patients with exudative pleural effusions of an unknown cause underwent medical thoracoscopy between October 2005 and September 2006 in Konyang University Hospital. The clinical data such as age, gender, preoperative pulmonary function, amounts of pleural effusion on lateral decubitus radiography were collected. The vital signs were recorded, and arterial blood gas analyses were performed five times during medical thoracoscopy in order to evaluate the cardiopulmonary status and acid-base changes. Results: The mean age of the patients was 56.8 years (range 22-79). The mean depth of the effusion on lateral decubitus radiography (LDR) was 27.49 mm. The medical thoracoscopic pleural biopsy was diagnostic in 24 patients (96.0%), with a diagnosis of tuberculosis pleurisy in 9 patients (36%), malignant effusions in 8 patients (32%), and parapneumonic effusions in 7 patients (28%). Medical thoracoscopy failed to confirm the cause of the pleural effusion in one patient, who was diagnosed with tuberculosis by a pericardial biopsy. There were no significant changes in blood pressure, heart rate, acid-base and no major complications in all cases during medical thoracoscopy (p>0.05). Conclusions: Medical thoracoscopy is a safe method for patients with unknown pleural effusions with a relatively high diagnostic accuracy.

Determination of homogentisic acid in human plasma by GC-MS for diagnosis of alkaptonuria (GC-MS를 이용한 혈장 중 호모겐티식산의 분석;알캅톤뇨증의 진단)

  • Thapa, Maheshwor;Yu, Jundong;Lee, Wonjae;Islam, Fokhrul;Yoon, Hye-Ran
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.323-330
    • /
    • 2015
  • Alkaptonuria, a rare inherited metabolic disease, is characterized by a lack of homogentisate dioxygenase and accumulation of homogentisic acid (HGA), leading to homogentisic aciduria, arthritis, and ochronosis. In this study, a rapid analytical method, without an expensive and tedious solid phase extraction step, was developed to quantify HGA in plasma using GC-MS. HGA-spiked pooled plasma samples were subjected to liquid-liquid extraction (LLE) with ethyl acetate, followed by trimethylsilyl derivatization (TMS) and GC-MS quantification using selected ion monitoring. The formation of TMS derivative of the 1 carboxylic and 2 hydroxyl functional groups was performed by reacting BSTFA (with 10% TMCS) for 5 min at 80 ℃. For selected ion monitoring, quantification and confirmation ions were determined based on specific ions (m/z 384, m/z 341 and m/z 252) of the TMS derivative of HGA. Calibration curves of pooled normal plasma specimens showed a linear relationship in the range of 1-100 ng/µL. The precision and accuracy were within a relative standard deviation (RSD) of 1 to 15% and a bias of -5 to 25%. Recoveries were obtained in the range of 99-125% and 95-115% for intra-day and inter-day assay, respectively, at 2, 20 and 80 ng/µL. The limit of detection (LOD) and limit of quantification (LOQ) were 0.4 ng/µL and 4 ng/µL, respectively. No homogentisic acid was excreted from normal Korean plasma samples. Collectively, the results from the present study suggest that this method could be useful for routine diagnosis and therapeutic monitoring of alkaptonuria patients with excellent sensitivity and rapidity.

Echocardiographic Diagnosis of Pulmonary Arterial Hypertension in Chronic Lung Disease with Hypoxemia (만성 저산소성 폐질환의 폐동맥 고혈압에 대한 심초음파 검사)

  • Chang, Jung-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.846-855
    • /
    • 1999
  • Background : Secondary pulmonary hypertension is an important final endpoint in patients with chronic hypoxic lung disease, accompanied by deterioration of pulmonary hemodynamics. The clinical diagnosis of pulmonary hypertension and/or cor pulmonale could be difficult, and simple noninvasive evaluation of pulmonary artery pressures has been an relevant clinical challenge for many years. Doppler echocardiography might to be a more reliable method for evaluating pulmonary hemodynamics in such patients in terms of the accuracy, reproducibility and easiness for obtaining an appropriate echocardiographic window than M-mode echocardiography. The aim of this study was to assess echocardiographic parameters associated with pulmonary arterial hypertension, defined by increasing right ventricular systolic pressure(RVSP), calculated from trans-tricuspid gradient in patients with chronic hypoxic lungs. Method : We examined 19 patients with chronic hypoxic lung disease, suspected pulmonary hypertension under the clinical guidelines by two dimensional echocardiography via the left parasternal and subcostal approach in a supine position. Doppler echocardiography measured RVSP from tricuspid regurgitant velocity in continuous wave with 2.5MHz transducer and acceleration time(AT) on right ventricular outflow tract in pulsed wave for the estimation of pulmonary arterial pressure. Results : On echocardiography, moderate to severe degree of pulmonary arterial hypertension was defined as RVSP more than 40mmHg, presenting tricuspid regurgitation. Increased right ventricular endsystolic diameter and shortened AT were noted in the increased RVSP group. Increased RVSP was correlated negatively with the shortening of AT. Other clinical data, including pulmonary functional parameters, arterial blood gas analysis and M mode echocardiographic parameters were not changed significantly with the increased RVSP. Conclusion : These findings suggest that shortened AT on pulsed doppler can be useful when quantifying pulmonary arterial pressure with increased RVSP in patients with chronic lung disease with hypoxemia. Doppler echocardiography in pulmonary hypertension of chronic hypoxic lungs is an useful option, based on noninvasiveness under routine clinical practice.

  • PDF

Correlation between High-Resolution CT and Pulmonary Function Tests in Patients with Emphysema (폐기종환자에서 고해상도 CT와 폐기능검사와의 상관관계)

  • Ahn, Joong-Hyun;Park, Jeong-Mee;Ko, Seung-Hyeon;Yoon, Jong-Goo;Kwon, Soon-Seug;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Moon, Hwa-Sik;Park, Sung-Hak;Song, Jeong-Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.3
    • /
    • pp.367-376
    • /
    • 1996
  • Background : The diagnosis of emphysema during life is based on a combination of clinical, functional, and radiographic findings, but this combination is relatively insensitive and nonspecific. The development of rapid, high-resolution third and fourth generation CT scanners has enabled us to resolve pulmonary parenchymal abnormalities with great precision. We compared the chest HRCT findings to the pulmonary function test and arterial blood gas analysis in pulmonary emphysema patients to test the ability of HRCT to quantify the degree of pulmonary emphysema. Methods : From october 1994 to october 1995, the study group consisted of 20 subjects in whom HRCT of the thorax and pulmonary function studies had been obtained at St. Mary's hospital. The analysis was from scans at preselected anatomic levels and incorporated both lungs. On each HRCT slice the lung parenchyma was assessed for two aspects of emphysema: severity and extent. The five levels were graded and scored separately for the left and right lung giving a total of 10 lung fields. A combination of severity and extent gave the degree of emphysema. We compared the HRCT quantitation of emphysema, pulmonary function tests, ABGA, CBC, and patients characteristics(age, sex, height, weight, smoking amounts etc.) in 20 patients. Results : 1) There was a significant inverse correlation between HRCT scores for emphysema and percentage predicted values of DLco(r = -0.68, p < 0.05), DLco/VA(r = -0.49, p < 0.05), FEV1(r = -0.53, p < 0.05), and FVC(r = -0.47, p < 0.05). 2) There was a significant correlation between the HRCT scores and percentage predicted values of TLC(r = 0.50, p < 0.05), RV(r = 0.64, p < 0.05). 3) There was a significant inverse correlation between the HRCT scores and PaO2(r = -0.48, p < 0.05) and significant correlation with D(A-a)O2(r = -0.48, p < 0.05) but no significant correlation between the HRCT scores and PaCO2. 4) There was no significant correlation between the HRCT scores and age, sex, height, weight, smoking amounts in patients, hemoglobin, hematocrit, and wbc counts. Conclusion : High-Resolution CT provides a useful method for early detection and quantitating emphysema in life and correlates significantly with pulmonary function tests and arterial blood gas analysis.

  • PDF

Clinical Differential Diagnosis of Usual Interstitial Pneumonia from Nonspecific Interstitial Pneumonia (통상성 간질성 폐렴과 비특이성 간질성 폐렴의 임상적 감별 진단)

  • An, Chang-Hyeok;Koh, Young-Min;Chung, Man-Pyo;Suh, Gee-Young;Kang, Soo-Jung;Kang, Kyeong-Woo;Ahn, Jong-Woon;Lim, Si-Young;Kim, Ho-Joong;Han, Jeung-Ho;Lee, Kyung-Soo;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.6
    • /
    • pp.932-943
    • /
    • 2000
  • Background : Nonspecific interstitial pneumonitis (NSIP) is most likely to be confused with usual interstitial pneumonitis (UIP). Unlike patients witþ UIP, the majority of patients with NSIP have a good prognosis, with most patients improving after treatment with corticosteroids. Therefore it is clinically important to differentiate NSIP from UIP. Up to now, the only means of differentiating these two diseases was by means of surgical lung biopsy. American Thoracic Society (ATS) proposed a clinical diagnostic criteria for UIP to provide assistance to clinicians in its diagnosis without surgical lung biopsy. This study is aimed to investigate whether there were clinical and radiological differences between NSIP and UIP, and the usefulness of ATS clinical diagnostic criteria for UIP in Korea. Methods : We studied 60 patients with UIP and NSIP confirmed by surgical lung biopsy. Clinical manifestations, pulmonary function test, arterial blood gas analysis, bronchoalveolar lavage (BAL), and high resolution computed tomography (HRCT) were evaluated and analyzed by Chi-square test or t-test. The clinical criteria for UIP proposed by ATS were applied to all patients with idiopathic interstitial pneumonia. Results : Forty-two patients with UIP and 18 with NSIP were pathologically identified. Among the 18 patients with NSIP (M : F=1 : 17), the mean age was 55.2$\pm$8.4 (44~73) yr. Among the 42 patients with UIP (M : F=33 : 9), the mean age was 59.5$\pm$7.1 (45~74) yr (p=0.046). Fever was more frequent in NSIP (39%) (p=0.034), but clubbing was frequently observed in UIP (33%) (p=0.023). BAL lymphocytosis was more frequent (23%) (p=0.0001) and CD4/CD8 ratio was lower in NSIP (p=0.045). On HRCT, UIP frequently showed honeycomb appearance (36 of 42 patients) though not in NSIP (p=0.0001). Six of 42 UIP patients (14.3%) met the ATS clinical criteria for IPF, and 3 of 16 NSIP patients (18.8%) met the diagnostic criteria. Conclusion : Being a relatively young female and having short duration of illness, fever, BAL lymphocytosis, low CD4/CD8 ratio with the absence of clubbing and honeycomb appearance in HRCT increase the likelihood of the illness being NSIP. The usefulness of ATS clinical diagnostic criteria for UIP may be low in Korea.

  • PDF

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Etiologies and Prognostic Factors of Chronic Cor Pulmonale (만성 폐성심의 원인 질환 빛 예후 인자에 관한 연구)

  • Park, Yoong-In;Kim, Sang-Hyun;Ha, Jae-Kyung;Kim, Seong-Ho;An, Byoung-Jae;Bae, Woo-Hyung;Lee, Hyeon-Gook;Chun, Kook-Jin;Hong, Taek-Jong;Park, Soon-Kew;Shin, Yung-Woo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.5
    • /
    • pp.609-617
    • /
    • 1999
  • Background: The aims of this study were to assess the etiologies, survival and prognostic factors of patients with chronic cor pulmonale visited Pusan National University Hospital. Methods : This study included 103 patients with chronic cor pulmonale. There were 67 men and 36 women. The diagnosis of chronic cor pulmonale was primarily based on the presence of underlying lung disorder and echocardiographic finding of enlarged or hypertrophied right ventricle. Other clinical data including patients' symptoms and signs, findings of arterial blood gas analysis, hematologic and biochemical laboratory and pulmonary function test were assessed. Results: The most common underlying lung disorder was pulmonary tuberculosis(59.2%) and chronic obstructive pulmonary disease was the next(28.2%). The survival rate was 57% in one year, 45% in two years, and 34% in three years. The prognostic factors were maximal voluntary ventilation(MVV), forced vital capaoity(FVC), $FEV_1$ serum Na, vital capacity(VC), serum albumin and peak expiratory flow(PEF) in univariate analysis. And in multivariate analysis, serum albumin(p=0.0144) and VC(p=0.0078) were statistically significant. Conclusion: Pulmonary tuberculosis was the most important underlying lung disorder in chronic cor pulmonale. The survival rate was 57% in one year, 45% in two years, and 34% in three years. Serum albumin (p=0.0144) and VC(p=0.0078) were statistically significant prognostic factors.

  • PDF

A Study of Acute Gastroenteritis in Neonates Transfered from Postpartum Care Centers (산후조리원에서 전원되어 입원한 신생아 급성 장염 환자들에 대한 임상적 고찰)

  • Kim, Jong Suh;Lee, Hae Sung;Choi, Jung Hwan;Shin, Yoon Jung;Koo, Mi Lim;Kim, Sung Sin;Kim, Heui Suck;Kim, Eun Ah;Yoon, Sin Won;Kwon, Jae Hoon;Yoon, Sin Won;Kim, Jong Hoon;Sin, Sun Heui;Koo, Sung Kyung;Yang, Sung;Yoo, Sin;Ahn, Young Min;Kim, Eun Mi;Lee, Dong Hwan
    • Pediatric Infection and Vaccine
    • /
    • v.10 no.2
    • /
    • pp.186-192
    • /
    • 2003
  • Purposes : Recently, acute gastroenteritis broke out among the neonates transferred from postpartum care centers located in Seoul, and Gyeounggi area. Thus, we researched the cause, progress and characters of the disease by analyzing the cases from 9 hospitals in Seoul and Gyeounggi area. Methods : We conducted retrospective study of 33 neonates transferred from postpartum care centers from October 2001 to July 2002 : we divided the neonates into 2 groups. The severe group had any of following 5 conditions : blood pH <7.20, respiratory difficulty, mechanical ventilation, shock, and disseminated intravascular coagulation. And the rest were classified into the moderate group. Results : The severe group was significantly more aged than the moderate group(P= 0.005). Weight loss was significantly severe in the severe group(P=0.0512). In blood gas analysis, bicarbonate was less in the severe group than the moderate group(P=0.032). In the virus examination, rotavirus was detected in 7 cases, and astrovirus was detected in 1 case. In the severe group, 4 neonates were dead. Conclusion : In acute gastroenteritis of neonates, early diagnosis and treatment are important. Thus, the legislation of postpartum care center is needed, and the medical specialists should be stationed in postpartum care center. We assume that the severe group had severe conditions because they were treated comparatively late. However, to find out the cause of the disease and to cope with it, the nationwide epidemiologic study on acute gastrenteritis of neonates is needed.

  • PDF

The Flow-rate Measurements in a Multi-phase Flow Pipeline by Using a Clamp-on Sealed Radioisotope Cross Correlation Flowmeter (투과 감마선 계측신호의 Cross correlation 기법 적용에 의한 다중상 유체의 유량측정)

  • Kim, Jin-Seop;Kim, Jong-Bum;Kim, Jae-Ho;Lee, Na-Young;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.13-20
    • /
    • 2008
  • The flow rate measurements in a multi-phase flow pipeline were evaluated quantitatively by means of a clamp-on sealed radioisotope based on a cross correlation signal processing technique. The flow rates were calculated by a determination of the transit time between two sealed gamma sources by using a cross correlation function following FFT filtering, then corrected with vapor fraction in the pipeline which was measured by the ${\gamma}$-ray attenuation method. The pipeline model was manufactured by acrylic resin(ID. 8 cm, L=3.5 m, t=10 mm), and the multi-phase flow patterns were realized by an injection of compressed $N_2$ gas. Two sealed gamma sources of $^{137}Cs$ (E=0.662 MeV, ${\Gamma}$ $factor=0.326\;R{\cdot}h^{-1}{\cdot}m^2{\cdot}Ci^{-1}$) of 20 mCi and 17 mCi, and radiation detectors of $2"{\times}2"$ NaI(Tl) scintillation counter (Eberline, SP-3) were used for this study. Under the given conditions(the distance between two sources: 4D(D; inner diameter), N/S ratio: $0.12{\sim}0.15$, sampling time ${\Delta}t$: 4msec), the measured flow rates showed the maximum. relative error of 1.7 % when compared to the real ones through the vapor content corrections($6.1\;%{\sim}9.2\;%$). From a subsequent experiment, it was proven that the closer the distance between the two sealed sources is, the more precise the measured flow rates are. Provided additional studies related to the selection of radioisotopes their activity, and an optimization of the experimental geometry are carried out, it is anticipated that a radioisotope application for flow rate measurements can be used as an important tool for monitoring multi-phase facilities belonging to petrochemical and refinery industries and contributes economically in the light of maintenance and control of them.