• Title/Summary/Keyword: Gas detection

Search Result 1,207, Processing Time 0.028 seconds

A Study on the $NO_2$ Gas Detection Chracteristics of the Octa(2-ethylhexyloxy) Copper-Phthalocyanine LB Film Depending on the Film Thickness and Temperature (두께와 온도에 따른 Octa(2-ethylhexyloxy) Copper-phthalocyanine LB막의 $NO_2$ 가스 탐지 특성에 관한 연구)

  • Yim, Jun-Seok;Shin, Hyun-Man;Kim, Young-Kwan;Kim, Jung-Soo;Sohn, Byung-Chung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.105-109
    • /
    • 1996
  • It is well known that the metallo- phthalocyanine (MPcs) are sensitive to toxic gaseous molecules such as $NO_2$ and also chemically and thermally stable, Therefore, lots of MPcs have been studied for the potential chemical sensor for $NO_2$ gas using quartz crystal microbalance(QCM) or electrical conductivity. In this study, ultra-thin films of octa(2-ethylhexyloxy)copper-phthalocyanine were prepared by Langmuir-Blodgett method and characterized by using UV-VIS absortion spectroscopy and ellipsometry. Transfer condition, and characterization of LB films were investigated and preliminary results of current-voltage(I-V) characteristics of these films exposed to $NO_2$ gas as a function of film thickness and temperature were discussed.

Determination of Clotiazepam in the Plasma Using Gas Chromatography/Mass Spectrometry with an Ion-Trap Detector and its Application to Pharmacokinetics in Healthy Volunteers

  • Kwon, Oh-Seung;Kim, Seung-Yong;Chung, Youn-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.2
    • /
    • pp.123-129
    • /
    • 2006
  • A method determining the plasma concentration of clotiazepam was developed by using gas chromatography/mass spectrometry with an ion-trap detector and was validated for applying pharmacokinetics to human volunteers orally taken 5 mg dose of clotiazepam. The detection limit was 1 ng/ml and the limit of quantitation was 5 ng/mt. Intraday reproducibility and accuracy bias % were less than 8.2 and 10.2% with inter-day variations for those being within 7.0 and 13.8%, respectively. The recovery of clotiazepam was higher than 87%. The principal pharmacokinetic parameters were determined from the plasma concentration-time plot by non-compartmental or two-compartmental analysis. In non-compartmental analysis, the elimination half-life of 10.4 hr and the area under the curve of 651.3 ng hr/ml were determined, and the maximal concentration (158.6 ng/ml) in the plasma was obtained at 0.56 hr post-dose. The developed method can be appropriate to apply pharmacokinetics and bioequivalence of clotiazepam.

Simultaneous Determination of Alkoxyalcohols in Wet Wipes Using Static Headspace Gas Chromatography and Mass Spectrometry

  • Lee, Soojin;Pyo, Heesoo;Chung, Bong Chul;Kim, Haidong;Lee, Jeongae
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.11
    • /
    • pp.3280-3288
    • /
    • 2014
  • Alkoxyalcohols are used as solvents or preservatives in various consumer products such as wet wipes. The metabolites of alkoxyalcohols are known to be chronically toxic and carcinogenic to animals. Thus, an analytical method is needed to monitor alkoxyalcohols in wet wipes. The aim of this study was to develop a simultaneous analytical method for 14 alkoxyalcohols using headspace gas chromatography coupled with mass spectrometry to analyze the wet wipes. This method was developed by comparing with various headspace extraction parameters. The linear calibration curves were obtained for the method ($r^2$ > 0.995). The limit of detection of alkoxyalcohols ranged from 2 to $200ng\;mL^{-1}$. The precision of the determinative method was less than 18.20% coefficient of variation both intra and inter days. The accuracy of the method ranged from 82.86% to 119.83%. (2-Methoxymethylethoxy)propanol, 2-phenoxyethanol, and 1-phenoxy-2-propanol were mainly detected in wet wipes.

Simultaneous detection method for pesticide residues in meat by gas chromatograph-mass selective detector (Gas chromatograph-mass selective detector를 이용한 식육 중 잔류농약의 동시분석)

  • Hong In-Suk;Choi Yoon-Hwa;Kweon Taek-Boo;Lee Jung-Hark
    • Korean Journal of Veterinary Service
    • /
    • v.28 no.3
    • /
    • pp.285-294
    • /
    • 2005
  • This study was conducted to investigate the extraction method for the determination of organochlorine, organophosphorus and synthetic pyrethroid pesticide residues in beef fat by gas chromatography-mass selective detector(GC-MSD). Twenty one pesticide residues in fat were determined using a simple and rapid procedure based on solid- phase extraction(SPE) clean-up cartridges with octadecyl $(C_{18})-bonded$ porous silica, florisil, $10\%$ deactivated florisil. a tandem $C_{18}$ and florisil and a tandem $C_{18}$ and $10\%$ deactivated florisil. Solvent-solvent extraction using acetonitrile was not satisfied to eliminate fat interference for pesticide residue analysis by GC-MSD, and the recoveries of the method in fat ranged from 16.2 to $57.3\%$ except DDT$(83.2\%)$. The recoveries of SPE methods using a tandem $C_{18}$ and Florisil was $59.6\~123.8\%$ except fenitrothion $(135.2\%)$. the SPE method was verified the satisfactory performance of pre-treatment for pesticide residues analysis in fat by GC-MSD. The efficiency of florisil deactivated with $10\%$ water has been not proved significantly on recoveries of pesticide residues in fat.

Headspace Hanging Drop Liquid Phase Microextraction and Gas Chromatography-Mass Spectrometry for the Analysis of Flavors from Clove Buds

  • Jung, Mi-Jin;Shin, Yeon-Jae;Oh, Se-Yeon;Kim, Nam-Sun;Kim, Kun;Lee, Dong-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.2
    • /
    • pp.231-236
    • /
    • 2006
  • A novel sample pretreatment technique, headspace hanging drop liquid phase microextraction (HS-LPME) was studied and applied to the determination of flavors from solid clove buds by gas chromatography-mass spectrometry (GC-MS). Several parameters affecting on HS-LPME such as organic solvent drop volume, extraction time, extraction temperature and phase ratio were investigated. 1-Octanol was selected as the extracting solvent, drop size was fixed to 0.6 $\mu$L. 60 min extraction time at 25 ${^{\circ}C}$ was chosen. HS-LPME has the good efficiency demonstrated by the higher partition equilibrium constant ($K_{lh}$) values and concentration factor (CF) values. The limits of detection (LOD) were 1.5-3.2 ng. The amounts of eugenol, $\beta$-caryophyllene and eugenol acetate from the clove bud sample were 1.90 mg/g, 1.47 mg/g and 7.0 mg/g, respectively. This hanging drop based method is a simple, fast and easy sample enrichment technique using minimal solvent. HSLPME is an alternative sample preparation method for the analysis of volatile aroma compounds by GC-MS.

Selective 3,4-Dihydroxyphenylalanine Analysis in Human Urine as Ethoxycarbonyltert-butyldimethylsilyl Derivatives by Gas Chromatography-Mass Spectrometry

  • Paik, Man-Jeong;Nguyen, Duc-Toan;Yoon, Jae-Hwan;Cho, In-Seon;Shim, Woo-Young;Kim, Kyoung-Rae;Cho, Ki-Hong;Choi, Sang-Dun;Lee, Gwang
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.3
    • /
    • pp.977-980
    • /
    • 2011
  • A new analytical method for measurement of 3,4-dihydroxyphenylalanine (DOPA) in human urine was developed. DOPA from an aqueous solution was converted into an ethoxycarbonyl (EOC) derivative. A tertbutyldimethylsilyl (TBDMS) reaction under anhydrous conditions was then attempted for analysis by gas chromatography-mass spectrometry in selected ion monitoring mode. A new mass spectral data on DOPA as a tri-EOC/mono-TBDMS derivative was built. This method showed good linearity (r ${\geq}$ 0.999), precision (% relative standard deviation = 3.1-9.2), and accuracy (% relative error = -7.2-8.8), with a detection limit of 0.05 ng/mL. This selective and accurate method of DOPA analysis will be useful for biochemical monitoring of various neurological disorders including Parkinson's disease in biological fluids.

Development of a Validated Determination of Methylsulfonylmethane in Dietary Supplement by Gas Chromatography (기체크로마토그래피를 이용한 식이보충제에서 메틸설포닐메탄의 검증된 분석법 개발)

  • Park, Sang-Wook;Lee, Wonjae
    • KSBB Journal
    • /
    • v.30 no.4
    • /
    • pp.141-147
    • /
    • 2015
  • The convenient determination of methylsulfonylmethane (MSM) for a commercially available dietary supplement was developed using gas chromatography (GC)-flame ionization detector (FID). Chromatography was performed on a capillary column ($0.32mm\;I.D{\times}30m$, $0.25{\mu}m$) coated with dimethylpolysiloxane using diethylene glycol methyl ether as an internal standard. The performance characteristics of GC were evaluated in terms of selectivity, linearity, precision, accuracy, recovery, limit of detection (LOD) and limit of quantification (LOQ). The calibration curve was highly linear (the coefficient of determination: 0.9979) within the concentration range of $10.0{\sim}800.0{\mu}g/mL$ for MSM. The recoveries for three fortified concentrations were 96.7~97.1%, 96.6~97.3% and 96.8~97.2%, respectively. The LOD and LOQ of the method were $0.29{\mu}g/mL$ and $0.97{\mu}g/mL$, respectively. All obtained results were acceptable according to the guidelines of the Association of Official Analytical Chemists for dietary supplements. Thus, the validated analytical method using the GC-FID system is suitable for the determination of MSM in dietary supplement formulations for quality control.

Carbon Monoxide Sensor Based on a B2HDDT-doped PEDOT:PSS Layer

  • Memarzadeh, R.;Noh, Hui-Bog;Javadpour, S.;Panahi, F.;Feizpour, A.;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.8
    • /
    • pp.2291-2296
    • /
    • 2013
  • An efficient carbon monoxide (CO) sensor was developed based on poly(3,4-ethylenedioxy)thiophenepoly(styrenesulfonate) (PEDOT:PSS) modified with a new pyrimidine-fused heterocyclic compound, bis(2-hydroxyphenyl)dihydropyrido[2,3-d:6,5-d]dipyrimidine-tetraone (B2HDDT). B2HDDT remains stable in the polymer matrix through interactions with functional groups of the polymer. It created prominent sites that captured CO gas, and the experimental parameters, including the amount of doped B2HDDT in the PEDOT:PSS film, were optimized. The sensor probe was also examined to verify its reliability for detecting CO in the presence of atmospheric gases in a discriminating manner. NMR, AFM, and FT-IR spectra were obtained to evaluate the structure and morphology of the B2HDDT-doped PEDOT:PSS (PEDOT:PSS/B2HDDT) film. The content of 35 vol % B2HDDT (7.0 mM) in PEDOT:PSS provided the largest response factor (${\Delta}R/R_o$) for the CO gas. The sensor response was reproducible, with a relative standard deviation < 5% (n = 5). The detection limit was determined to be $0.44{\pm}0.05$ vol %.

Characteristics of Low-power Microwave Induced Plasma Emission Spectrum and Detection of $CO_2$ (저출력 마이크로파 유도 플라스마 방출스펙트럼의 특성과 $CO_2$ 분석)

  • Noh, Seung Man;Park, Chang Joon;Kim, Young Sang
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.4
    • /
    • pp.235-242
    • /
    • 1996
  • A surfatron-type microwave induced plasma (MIP) cavity has been constructed, which can be easily interfaced with a gas chromatograph. Various plasma gases such as He, Ar and N2 were used to generate the MIP and small amounts of CO2 gases were injected through the MIP to obtain characteristic spectrum of each plasma gas and to study feasibility of the MIP as a soft ionization source. Since He and Ar plasmas have high metastable state energy, it was not possible to detect sample gas in molecular state. With N2 plasma, however, a strong emission of molecular ions could be detected owing to its low metastable state energy.

  • PDF

A New Start-up Method for a Load Commutated Inverter for Large Synchronous Generator of Gas-Turbine

  • An, Hyunsung;Cha, Hanju
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.201-210
    • /
    • 2018
  • This paper proposes a new start-up method for a load commutated inverter (LCI) in a large synchronous gas-turbine generator. The initial rotor position for start-up torque is detected by the proposed initial angle detector, which consists of an integrator and a phase-locked loop. The initial rotor position is accurately detected within 150ms, and the angle difference between the real position and the detected position is less than 1%. The LCI system operates in two modes (forced commutation mode and natural commutation mode) according to operating speed range. The proposed controllers include a forced commutation controller for the low-speed range, a PI speed controller and a PI current controller, where the forced commutation controller is connected to the current controller in parallel. The current controller is modeled by Matlab/Simulink, where a six-pulse delay of the thyristor and a processing delay are considered by using a zero-order hold. The performance of the proposed start-up method is evaluated in Matlab/Psim at standstill and at low speed. To verify the feasibility of the method, a 5kVA LCI system prototype is implemented, and the proposed initial angle detector and the system performance are confirmed by experimental results from standstill to 900rpm.