• Title/Summary/Keyword: Gas detection

Search Result 1,196, Processing Time 0.029 seconds

$NO_2$Gas Detection Characteristics of Octa-dodecyloxy Copper-phthalocyanine Langmuir-Blodgett(LB) Films

  • Koo, Ja-Ryong;Kim, Young-Kwan;Kim, Jung-Soo
    • Electrical & Electronic Materials
    • /
    • v.11 no.10
    • /
    • pp.78-80
    • /
    • 1998
  • Metallo-phthalocyanines(MPcs) are very sensitive to toxic molecules such as electron affinitive NO2 gas and also chemically and thermally stable since losts of MPcs have been studied for the potential chemcial gas sensors for $NO_2$ using their electrical conductivity. In this study, thin films of octa-dodecyloxy copper -phthalocyanine were prepared by Langmuir-Blodgett(LB) method and characterized by using UV/Vis absorption spectroscopy, and ellipsometry. It was found that the proper transfer surface pressure for the film deposition was 25mN/m and the limiting area per molecule was $112\AA$/molecule. The film thickness of one layer was $64\AA$. Current-voltage(I-V) characteristics of these films were investigated as a function of film thickness.

  • PDF

The Sensing Characteristics of $WO_3$ Thin Films for $NO_x$ Gas Detection with the Change of Deposition Methods (증착방법에 따른 $NO_x$가스 감지용 $WO_3$박막센서의 특성 변화 연구)

  • 김태송;김용범;유광수;성기숙;정형진
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.4
    • /
    • pp.387-393
    • /
    • 1997
  • In order to apply WO3 thin films to the semiconducting NOx gas sensors as a sensing material, which have been expected to show good electrical properties, such as large sensitivity, rapid responsibility, and high selectivity, the fabrication method and their sensing characteristics were studied. The variations of surface morphologies, crystallographic orientations and crystallinity with the WO3 thin film growing methods thermal evaporation and DC sputtering methods were investigated by using scanning electron microscopy (SEM) and X-ray diffraction(XRD) analysis. As a result of sensitivity (Rgas/Rair) measurements for the 5 ppm NO2 test gas, the sensitivity values were 113 for the sputtered films and 93 for the evaporated films. It was also observed that the recovery rate of a sensing signal after measuring sensitivity was faster in the sputtered films than in the evaporated films.

  • PDF

Detection of Abnormal Signals in Gas Pipes Using Neural Networks

  • Min, Hwang-Ki;Park, Cheol-Hoon
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.669-670
    • /
    • 2008
  • In this paper, we present a real-time system to detect abnormal events on gas pipes, based on the signals which are observed through the audio sensors attached on them. First, features are extracted from these signals so that they are robust to noise and invariant to the distance between a sensor and a spot at which an abnormal event like an attack on the gas pipes occurs. Then, a classifier is constructed to detect abnormal events using neural networks. It is a combination of two neural network models, a Gaussian mixture model and a multi-layer perceptron, for the reduction of miss and false alarms. The former works for miss alarm prevention and the latter for false alarm prevention. The experimental result with real data from the actual gas system shows that the proposed system is effective in detecting the dangerous events in real-time with an accuracy of 92.9%.

  • PDF

Development of Inspection Gauge System for Gas Pipeline

  • Han, Hyung-Seok;Yu, Jae-Jong;Park, Chan-Gook;Lee, Jang-Gyu
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.370-378
    • /
    • 2004
  • An autonomous pipeline inspection gauge system has been developed for determining position, orientation, curvature, and deformations such as dents and wrinkles of operating pipelines by Korea Gas Company and Seoul National University. The most important part of several subsystems is the Strapdown Inertial Measurement Unit (SIMU), which is integrated with velocity and distance sensors, weld detection system, and digital recording device. The Geometry Pipeline Inspection Gauge (GeoPIG) is designed to operate continuously and autonomously for a week or longer in operating gas pipelines. In this paper, the design concepts, system integration, and data processing/analysis method for the PIG will be presented. Results from the recent experiment for a 58 kilometer gas pipeline will be discussed.

Analysis of Antioxidants in Fatty Foods Using Gas Chromatography/Mass Spectrometry (식품 중 Gas Chromatography/Mass Spectrometry를 이용한 산화방지제의 분석에 관한 연구)

  • 이정애;노동석
    • Journal of Food Hygiene and Safety
    • /
    • v.12 no.3
    • /
    • pp.210-216
    • /
    • 1997
  • The prevention of oxidative degradation in fats and oils is largely controlled by the use of synthetic phenolic antioxidants. Antioxidants, BHA: 2-&-3-tert-butyl-4-hydroxyanisol, BHT: 3,5-di-tert-butyl-4-hydroxytoluene, TBHQ: tert-butylhydroquinone, PG: propyl gallate, PTG: pentyl gallate, OG:octyl gallate, were extracted from fatty foods with hexane and from hexane layer to presaturated acetonitrile with hexane. The polar phenolic hydroxyl groups of antioxidants were silylated with MSTFA and injected to Gas Chromatography/Mass Spectrometry. The calibration plots were linear in the investigated range, 0.1~10.0 $\mu\textrm{g}$/g. The limit of detection for 6 phenolic antioxidants was 0.1 $\mu\textrm{g}$/g. Recoveries and reproducibilities from samples fortified at 1.0 $\mu\textrm{g}$/g were in the range of 70~90% and 0.5~13%, respectively. The simultaneous determination of phenolic antioxidants in fatty foods using GC/MS-SIM mode and macro program was described.

  • PDF

Peculiarities of gas sensing characteristics of SnO2-based sensors modified by SnO2-Au nanocomposites synthesized by SILD method

  • Korotcenkov, Ghenadii;Cho, Beong-Ki;Tolstoy, Valery;Gulina, Larisa B.;Han, Sang-Do
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.417-422
    • /
    • 2009
  • The problems associated with the synthesis, characterization and application of $SnO_2$-Au nanocomposites for the optimization of conductometric gas sensors have been discussed in this report. Nanocomposites have been synthesized on the surface of $SnO_2$ films using successive ionic layer deposition(SILD) method. It has been shown that the proposed approach to surface modification of metal oxide films is an excellent method for the optimization of the operating characteristics of $SnO_2$-based gas sensors, being developed for the detection of reducing gases as well as ozone.

A Study on Concentration Detection Technology of Air Mixing Gas according to Temperature Variation for Refrigerator Foam System (온도변화에 따른 냉장고 발포시스템용 에어믹싱가스 농도검출기술에 관한 연구)

  • Koo, Yeong-Mok;Yang, Jun-Suk;Jo, Sang-Young;Kim, Min-Seong;Noh, Chun-Su
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.19 no.2
    • /
    • pp.95-100
    • /
    • 2016
  • This study proposes the temperature compensation algorithm using thermopile detector for non-dispersive infrared Nitrogen gas sensor. From the output voltage of thermistor that is attached onto the infrared detector, the ambient temperature was extracted. The effects of temperatures on the properties of sensor module characteristics of narrow bandpass filter, optical cavity and infrared lamp, and air mixing gas have been introduced in order to implement the temperature compensation algorithm.

Investigation Between Gas in Oil Analysis and the Source of Trouble in Transformer (변압기 절연유 가스분석과 고장원인 검토)

  • Kweon Dong-Jin;Kwak Joo-Sik;Eun Jong-Young;Min Byeong-Moon;Yu Dong-Gyon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.8
    • /
    • pp.343-349
    • /
    • 2005
  • The gas in oil analysis of transformer is the most widely used technology for diagnosis of transformer in the world. It has brought excellent results to prevention of transformer failure. The criteria for maintenance and judgement, however, is still required continuous supplement to improve the accuracy of the diagnosis on the basis of accumulated data of gas analysis and investigations in the transformer In this study, the relationship between the detection rate of the defects and the source of troubles are analyzed according to the investigation in the transformer, which was conducted by KEPCO in 2004. As a result, the validity of the criteria being used at present was examined thoroughly.

Measurement of the Ionization Coefficient in Gases by the Luminous-flux Method (광속법을 이용한 기체의 전이계수 측정)

  • 백용현;하성철;이복희;김희택;김정섭
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.7
    • /
    • pp.289-296
    • /
    • 1985
  • The Townsend primary ionization coefficient a was measured by the luminous-flux method using the fact that the intensity of radiant light is proportional to electron density in the townsend discharge domain. The ranges of measurements were 15for He gas and 10

  • PDF

Development of Real Time Monitoring System for third party damage Detection Using Wireless Data Communicating (무선데이타 통신을 이용한 실시간 타공사 감시 시스템 개발)

  • Park S.S.;Cho S.H.;Yoo H.R.;Kim D.K.;Jeon K.S.;Park D.J.;Koo S.J.;Rho Y.W.
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.3 s.11
    • /
    • pp.59-64
    • /
    • 2000
  • The real time monitoring system is developed to detect third party damage imposed on natural gas pipeline and to estimate a damage position in section of pipeline in need of monitoring the third party damage. The monitoring system uses wireless data communication in order to build up data communication network. The availability of monitoring system was evaluated through full scale field damage test at Masan's submarine gas pipeline. It was turned out that the estimation error was one percentage of the propagation speed of damage sound in the gas pipeline.

  • PDF