• Title/Summary/Keyword: Gas detection

Search Result 1,196, Processing Time 0.027 seconds

Sensing Characterization of Metal Oxide Semiconductor-Based Sensor Arrays for Gas Mixtures in Air

  • Jung-Sik Kim
    • Korean Journal of Materials Research
    • /
    • v.33 no.5
    • /
    • pp.195-204
    • /
    • 2023
  • Micro-electronic gas sensor devices were developed for the detection of carbon monoxide (CO), nitrogen oxides (NOx), ammonia (NH3), and formaldehyde (HCHO), as well as binary mixed-gas systems. Four gas sensing materials for different target gases, Pd-SnO2 for CO, In2O3 for NOx, Ru-WO3 for NH3, and SnO2-ZnO for HCHO, were synthesized using a sol-gel method, and sensor devices were then fabricated using a micro sensor platform. The gas sensing behavior and sensor response to the gas mixture were examined for six mixed gas systems using the experimental data in MEMS gas sensor arrays in sole gases and their mixtures. The gas sensing behavior with the mixed gas system suggests that specific adsorption and selective activation of the adsorption sites might occur in gas mixtures, and allow selectivity for the adsorption of a particular gas. The careful pattern recognition of sensing data obtained by the sensor array made it possible to distinguish a gas species from a gas mixture and to measure its concentration.

The NO$_2$ gas detection characteristics of the DDilithium phthalocyanine(Li$_2$Pc) LB Film depending on the Temperatures (Dilithium phthalocyanine(Li$_2$Pc) LB막의 온도에 따른 NO$_2$ 가스 탐지 특성에 관한 연구)

  • 조형근;김태완;김정수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.31-34
    • /
    • 1995
  • The NO$_2$ gas-deteotion characteristics were investigated using the functional organic Langmuir-Blodgett(LB) files of Dilithium phthalocyanines(Li$_2$Pc). The optimum conditions for a film deposition were obtained through a study of $\pi$-A isotherms, and the deposited film status was confirmed by the ellipsometry measurements. A propel number of layers for the gas-detection was proved to be 9 layers from a measurement of a measurement of change in the electrical conductivities when the films were exposed to the 200 ppm of the NO$_2$ gases. A response time, recovery time, and reproducibility were also studied. A proper temperature which was able to activate gas interaction between NO$_2$ gases and Li$_2$Pc LB films was around 150$^{\circ}C$ judging from the electrical conductivities in a temperature range of 20 to 200$^{\circ}C$. It was found that at 150\ulcorner there are increments of electrical conductivities by 65 tines, 30 seconds of response time and 60 seconds of recovery tine when the filmswere exposed to the gasses.

  • PDF

A study on the determination of residual Antibiotics and Synthetic Antibacterial Agents in Meat(III) Simultaneous Gas Chromatography/Mass Spectrometry Analysis of Erythromycin and Tylosin (식육중의 잔류 항생.항균제의 검정에 관한 연구(III) Macrolide계 항생물질인 Erythromycin과 Tylosin의 Gas Chromatography/Mass Spectrometry 동시분석)

  • 류재천;송윤선;양종순;서지원;김명수;박종세
    • Journal of Food Hygiene and Safety
    • /
    • v.8 no.1
    • /
    • pp.17-23
    • /
    • 1993
  • In an attempt to quantitate and qualitate residual antibiotics and antibacterial agents n meat simultaneously, we studied a gas chromatogrphy-mass spectrometry (GC/MS) analysis. For a simultaneous analysis of macrolide antibiotics such as erythromycin and tylosin in meat, the homogenization with MeOH, defatting with n-hexane, extraction with CHCl3, elution with CHCl3 : MeOH=2:1 from Sep-Pak silica cartridge, acid gydrolysis, back extraction with CHCl3, and quantitation by selected ion monitoring(SIM) mode after trimethylsilyl derivatization were performed. The recoveries of erythromycin and tylosin (CV,%) at 10 ppm fortification level were 90.59(4.89) and 45.91(0.20) , and the detection limits of those were 0.02 and 2.0 $\mu\textrm{g}$/g beef, respectively. From these results, the developed analytical method using GC/MS-SIM mode allows excellent detection and quantitation of residual macrolide antibiotics in meats, using complementary method with bio-assay.

  • PDF

Simultaneous Determination of Urinary Nicotine and Cotinine Using Gas Chromatography/Nitrogen-Selective Detection (기체 크로마토그래피/질소-선택적 검출을 이용한 소변 중 니코틴과 코티닌의 동시 분석)

  • 김희갑;박미진
    • Environmental Analysis Health and Toxicology
    • /
    • v.16 no.4
    • /
    • pp.181-188
    • /
    • 2001
  • A gas chromatographic method was established for the simultaneous determination of urinary nicotine and cotinine. The analytes in basified urine containing a sufficient amount of Na$_2$S0$_4$were extracted into dichloromethane by vigorous shaking. Into the transferred organic phase was added a small amount of acidified methanol (0.5 N HCI in methanol), followed by concentrating the mixture to dryness using a mild stream of nitrogen gas. The concentrate was reconstituted with methanol and the final solution analyzed using the gas chromatograph equipped with the nitrogen-phosphorus detector. The reproducibility tests showed coefficients of variation less than 11% for both compounds. The percent recovery for both analytes ranged from 88 to 103%. The estimated method detection limits for nicotine and cotinine were 0.60 and 5.1 ng/mL, respectively. Extraction efficiencies for both nicotine and cotinine apparently declined without the addition of Na$_2$S0$_4$into the urine. Moreover, the absence of methanolic HCI in the extract resulted in almost complete evaporation of nicotine and partial loss of cotinine during the concentration process, indicating that the formation of nicotine-HCI and cotinine-HCI species is prerequisite to the suppression of the loss of both compounds.

  • PDF

A Study of The $NO_2$ Gas Detect Properties of N-docosyl pyridinium(TCNQ) LB Film depending on Temperature (온도에 따른 N-docosyl pyridinium(TCNQ) LB막의 $NO_2$ 가스탐지 특성에 관한 연구)

  • Yoo, B.H.;Han, Y.J.;Cho, H.K.;Kim, H.S.;Lee, C.H.;Kim, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.231-233
    • /
    • 1994
  • We have studied a properly of N-docosyl pyridinium(TCNQ) Langmuir-Blodgett film at room temperature with the $NO_2$ gas-detection characteristics. As a result, we have found that their conductivities were increased by 6 times at 5 layers(about $250{\AA}$ thickness) LB film. However, their reproducibility was not able to be measured at room temperature. Therefore, we must find their working temperature which was able to activate gas-detection characteristics. The $NO_2$ gas response experiments under 200 ppm concentration in $50^{\circ}C$ show that :here are increment of electrical conductivity by 8 times and 100 seconds of response time, and 200 seconds of recovery times at $60^{\circ}C$.

  • PDF

Noise Reduction Algorithm For The Detection of Fine Ion Signals in Residual Gas Analyzer (잔류가스분석기의 질량 스펙트럼 검출 성능 향상을 위한 잡음제거 알고리즘)

  • Heo, Gyeongyong;Choi, Hun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.102-107
    • /
    • 2019
  • This paper proposes a method to improve the mass spectral detection performance of the residual gas analyzer. By improving the mode estimation method for setting the threshold value and improving the additive noise elimination method, it is possible to detect mass spectrums having low peak values of the threshold level difficult to distinguish from noise. Ion signal blocks for each mass index with noise removed by the improved method are effective for eliminating invalid ion signals based on the linear and quadratic fittings. The mass spectrum can be obtained from the quadratic fitted curves for the reconstructed ion signal block using only the valid ion signals. In addition, the resolution of the mass spectrum can be improved by correcting the error caused by the shift of the spectral peak position. To verify the performance of the proposed method, computer simulations were performed using real ion signals obtained from the residual gas analysis system under development. The simulation results show that the proposed method is valid.

A Survey on the Software Technology of Health Management System for Aircraft Gas Turbine Engine (항공기용 가스터빈 엔진의 건전성 관리를 위한 소프트웨어 발전 동향)

  • Park, Iksoo;Ki, Taeseok;Kim, Junghoe;Min, Seongki
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.5
    • /
    • pp.13-21
    • /
    • 2018
  • Technology trends of onboard and ground health management system software for aircraft gas turbine engines are surveyed. The software has changed from ground based software for fault detection and identification to a model based health identification technology for onboard software. This advanced algorithm is currently under development in a technically advanced country while domestic research is on the birth stage. This paper suggested that the optimal development plan of the software considering current technology state.

Application of a Gas Chromatography/Luminol Detection System for Peroxyacetyl Nitrate Airborne Measurement

  • Khang, Bumju;Ahn, Joon Young;Song, Dasol;Lee, Gangwoong
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.2
    • /
    • pp.105-113
    • /
    • 2013
  • We constructed and tested an airborne peroxyacetyl nitrate (PAN) monitoring system based on luminol chemiluminescence detection with fast gas chromatography. This system allowed for simultaneous measurement of PAN and nitrogen dioxide ($NO_2$) with a time resolution of <2 min. Actual sample masses within the fixed volume sample loop at various altitudes and temperatures were adjusted to standard atmosphere, using measured pressures and temperatures. The airborne PAN measurement system was evaluated during two field studies above the southern Korean Peninsula in August and October 2009. The detection limit based on the ISO approach was 0.035 ppbv PAN, well below the observed concentrations of 0.185-1.49 ppbv during these studies. Under these conditions, the PAN mixing ratios were positively correlated with $O_x$ ($O_x=O_3+NO_2$), with slopes varying between 0.014 and 0.033 and intercepts between 22.6 and 55.1 ppbv $O_x$. The intercepts corresponded roughly to background $O_x$ mixing ratios in central Europe; however, the slopes were above the range of slopes reported in other studies. We also enhanced the durability, safety, and ease of maintenance of the PAN monitoring system by redesigning the structure of the conventional luminol cell.

Development of Analytical Technology Using the HS-SPME-GC/FID for Monitoring Aromatic Solvents in Urine

  • Lee, Mi-Young;Chung, Yun Kyung;Shin, Kyong-Sok
    • Mass Spectrometry Letters
    • /
    • v.4 no.1
    • /
    • pp.18-20
    • /
    • 2013
  • Headspace solid phase micro-extraction gas chromatography/flame ionization detection (HS-SPME-GC/FID) method was compared with headspace gas chromatography/mass selective detection (HS-GC/MS). Organic solvent-spiked urine as well as urine samples from workspace was analyzed under optimal condition of each method. Detection limit of each compound by HS-SPME-GC/FID was $3.4-9.5{\mu}g/L$, which enabled trace analysis of organic solvents in urine. Linear range of each organic solvent was $10-400{\mu}g/L$, with fair correlation coefficient between 0.992 and 0.999. The detection sensitivity was 4 times better than HS-GC/MS in selected ion monitoring (SIM) mode. Accuracy and precision was confirmed using commercial reference material, with accuracy around 90% and precision less than 4.6% of coefficient of variance. Among 48 urine samples from workplace, toluene was detected from 45 samples in the range of $20-324{\mu}g/L$, but no other solvents were found. As a method for trace analysis, SPME HS GC/FID showed high sensitivity for biological monitoring of organic solvent in urine.

A Study on the Algorithm for Detection of Partial Discharge in GIS Using the Wavelet Transform

  • J.S. Kang;S.M. Yeo;Kim, C.H.;R.K. Aggarwal
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.4
    • /
    • pp.214-221
    • /
    • 2003
  • In view of the fact that gas insulated switchgear (GIS) is an important piece of equipment in a substation, it is highly desirable to continuously monitor the state of equipment by measuring the partial discharge (PD) activity in a GIS, as PD is a symptom of an insulation weakness/breakdown. However, since the PD signal is relatively weak and the external noise makes detection of the PD signal difficult, it therefore requires careful attention in its detection. In this paper, the algorithm for detection of PD in the GIS using the wavelet transform (WT) is proposed. The WT provides a direct quantitative measure of the spectral content and dynamic spectrum in the time-frequency domain. The most appropriate mother wavelet for this application is the Daubechies 4 (db4) wavelet. 'db4', the most commonly applied mother wavelet in the power quality analysis, is very well suited to detecting high frequency signals of very short duration, such as those associated with the PD phenomenon. The proposed algorithm is based on utilizing the absolute sum value of coefficients, which are a combination of D1 (Detail 1) and D2 (Detail 2) in multiresolution signal decomposition (MSD) based on WT after noise elimination and normalization.