• Title/Summary/Keyword: Gas cooler

Search Result 158, Processing Time 0.027 seconds

Performance Analysis of a Carbon Dioxide(R744) Two-Stage Compression and One-Stage Expansion Refrigeration Cycle ($CO_2$용 2단압축 1단팽창 냉동 사이클의 성능 분석)

  • Roh, G.S.;Son, C.H.
    • Journal of Power System Engineering
    • /
    • v.13 no.6
    • /
    • pp.70-75
    • /
    • 2009
  • In this paper, cycle performance analysis of R744($CO_2$) two-stage compression and one-stage expansion refrigeration system is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include superheating degree, compressor efficiency, gas cooling pressure, mass flowrate ratio, outlet temperature of gas cooler and evaporating temperature in the carbon dioxide two-stage refrigeration cycle. The main results were summarized as follows : The cooling capacity of two-stage compression and one-stage expansion refrigeration system increases with the increasing superheating degree, compressor efficiency and gas cooling pressure, but decreases with the increasing mass flowrate ratio and evaporating temperature. The compression work of two-stage compression and one-stage expansion refrigeration system increases with the increasing superheating degree, outlet temperature of gas cooler, gas cooling pressure and evaporating temperature, but decreases with the increasing compressor efficiency and mass flowrate ratio. The COP of two-stage compression and one-stage expansion refrigeration system increases with the increasing compressor efficiency, but decreases with the increasing superheating degree, gas cooling pressure, mass flowrate ratio and evaporating temperature. Therefore, superheating degree, compressor efficiency, gas cooling pressure, mass flowrate ratio, outlet temperature of gas cooler and evaporating temperature of R744($CO_2$) two-stage compression and one-stage expansion refrigeration system have an effect on the cooling capacity, compressor work and COP of this system.

  • PDF

Performance Characteristics of Natural Gas Liquefaction Process using Liquid-gas Heat Exchanger (액-가스 열교환기를 적용한 천연가스 액화공정 성능 특성)

  • Yoon, Jung-In;Yoo, Sun-Il;Oh, Seung-Taek;Lee, Ho-Saeng;Lee, Sang-Gyu;Choi, Keun-Hyung
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.6
    • /
    • pp.44-48
    • /
    • 2009
  • In this paper, two different types of natural gas liquefaction cycle with 2 staged compression were designed and simulated to develop liquefaction process which is the core technology in the Industry of natural gas liquefaction plant. These include the cascade cycle with inter-cooler which is consisted of propane, ethylene and methane cycle. One of these is that liquid-gas heat exchanger is applied to between methane and ethylene cycles, and another is that liquid-gas heat exchanger is added to between ethylene and propane on the above process. Also, these cycles are compared with two staged cascade process using an inter-cooler. The COP of process2 is shown about 14.0% higher than that of process1, respectively. Also, the yield efficiency of LNG improved comparing with process1 with 11.5% lower specific power.

  • PDF

Effect of Two staged Inter-cooler on Efficiency of LNG Liquefaction Process (LNG 액화 사이클 효율에 미치는 2단 압축 인터쿨러의 영향)

  • Yoo, Sun-Il;Oh, Seung-Taek;Lee, Ho-Saeng;Yoon, Jung-In;Choi, Keun-Hyung;Lee, Sang-Gyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.1
    • /
    • pp.46-52
    • /
    • 2010
  • In this study, several types of natural gas liquefaction processes using two staged Inter-cooler are simulated and designed to secure a competitiveness in the industry of natural gas liquefaction plant. These processes are based on basic cascade process, and all of these are improved with two staged compressors type. One of types is applied Inter-cooler to each cycle such as propane, ethylene, methane, the other type is applied Inter-cooler to whole cycle. These processes are compared characteristics of performance with basic process. Cascade process with two staged Inter-cooler in the whole cycle is on the top ranked with increment ratio of COP about 13.7 ~ 20.5%, and yield efficiency of this process are improved comparing with the basic process by 23.8% ~ 35% lower specific power, respectively.

Application of Foil Gas Bearing to the 38kW, 100000 RPM Class High Speed Motor (38kW, 100000 RPM 고속모터에 대한 포일 가스 베어링 응용 개발)

  • Kim, Kyeong-Su;Park, Ki-Cheol;Kim, Seung-Woo;Lee, In
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.127-131
    • /
    • 2003
  • Foil gas bearing is a noncontact bearing operated by coupled interaction between hydrodynamic pressure of viscous fluid and elastic deformation of foil structure. It has valuable advantages, such as low power loss, long life, oilless environment and low vibration, over conventional bearings for the high speed applications. A high speed BLDC motor adopting the foil bearing has been developed. It is designed to have 38㎾ power at 100,000 RPM for a cryogenic cooler whose operating fluid is neon. In this paper, structural development details especially for the foil gas bearing and rotordynamics are presented.

  • PDF

Heat Transfer Characteristics of Carbon Dioxide in a Inclined Helical Coil Type Heat Exchanger with Inner Diameter Tube of 4.55 mm (내경 4.55 mm의 경사진 헬리컬 코일형 열교환기내 이산화탄소의 열전달 특성에 관한 연구)

  • Son, Chang-Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.1-6
    • /
    • 2007
  • The heat transfer coefficient and pressure drop during gas cooling process of $CO_2$ (R-744) in inclined helical coil copper tubes were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube, which is specified as the inner diameter of 4.55 mm. The refrigerant mass fluxes were varied from 200 to $600kg/m^2s$ and the inlet pressures of gas cooler were done 7.5 to 10.0 (MPa). The heat transfer coefficients of $CO_2$ in the inclined helical coil tubes increase with the increase of mass flux and gas cooling pressure of $CO_2$. The pressure drop of $CO_2$ in the gas cooler shows relatively good coincidence with those predicted by Ito's correlation developed for single-phase in a helical coil tube. The local heat transfer coefficient of $CO_2$ is well coincident with the correlation by Pitla et al. However, at the region near pseudo-critical temperature, the experiments indicate higher values than the Pitla et al. correlation.

  • PDF

The heat transfer characteristics of supercritical $CO_2$ in a horizontal tube (수평관내 $CO_2$의 초임계 영역내 열전달에 관한 연구)

  • Oh Hoo-Kyu;Lee Dong-Geon;Son Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.526-532
    • /
    • 2005
  • The cooling heat transfer coefficient of $CO_2$(R-744) in a horizontal tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump. a mass flow meter. a pre-heater and gas cooler(test section). The test section consists of a smooth, horizontal stainless steel tube of 7.75 mm inner diameter. The experiments were conducted at mass flux of 200 to $400\;kg/m^{2}s$ and the inlet cooling pressure of 7.5 MPa to 10.0 MPa. The variation of heat transfer coefficient tends to decrease as cooling pressure of $CO_2$ increases. The heat transfer coefficient with respect to mass flux increases as mass flux increases. The pressure drop of $CO_2$ in the gas cooler shows a relatively good agreement with that predicted by Blasius's correlation. The local heat transfer coefficient of $CO_2$ agrees well with the correlation by Bringer-Smith.

Evaluation of Structural Integrity and Heat Exchange Efficiency for Dimpled Tube Type EGR Cooler (딤플 튜브형 EGR Cooler 구조건전성 및 열효율 평가)

  • Seo, Young-Ho;Lee, Hyun-Min;Park, Jung-Won;Ku, Tae-Wan;Kim, Jeong;Kang, Beom-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.554-559
    • /
    • 2008
  • Most of vehicle manufacturers have applied exhaust gas recirculation (EGR) system to the development of diesel engines in order to obtain the high thermal efficiency without $NO_X$ and Particulate Matter (PM) emitted from the engine. EGR system, which reflow a cooled exhaust gas from vehicles burning diesel as fuel to a combustion chamber of engine, has been used to solve this problem. In order to confirm the safety of the EGR system, finite element analysis was carried out. The safety of EGR system against temperature variation in the shell and tubes was evaluated through the thermal and structural analysis, and the modal analysis using ANSYS was also performed. Finally, the performance of EGR system was verified through the experiment and numerical simulation using effectiveness-NTU method. Program for the estimation of the heat exchange efficiency of the EGR system with regard to the dimpled tube shape was developed.

  • PDF

Effects of Operating Parameters on Cooling Performance of a Transcritical $CO_2$ Mobile Air-Conditioning System (운전조건 변화가 $CO_2$ 자동차 에어컨 시스템의 냉방성능에 미치는 영향에 대한 실험적 연구)

  • Lee, Jun-Kyoung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.4
    • /
    • pp.67-75
    • /
    • 2007
  • This paper deals with the research for the effects of the operating parameters that could be used for a transcritical $CO_2$ mobile air-conditioning system on the cooling performance. The experimental conditions of the performance tests for a system and components such as a gas cooler and an evaporator were suggested to compare the performance of each with the standardized test conditions. And this research presents experimental results for the performance characteristics of a $CO_2$ mobile air conditioning system with various operating conditions such as different gas cooler inlet pressures and frontal air velocities/temperatures passing through an evaporator and a gas cooler. Experimental results show that the cooling capacity was more than 5kW and coefficient of performance (COP) was more than 2.1, also. Therefore, we checked that the mobile air-conditioning system using $CO_2$ has good performance compared to that using HFC-134a.

Experimental Studies on the Performance Characteristics of Heat Exchangers of $CO_2$ Air Conditioning System for Vehicle (자동차용 $CO_2$ 에어컨 시스템 열교환기 성능 특성에 관한 실험적 연구)

  • Kim, Sung-Chul;Lee, Dong-Hyuk;Won, Jong-Phil
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.1
    • /
    • pp.146-153
    • /
    • 2009
  • The performance characteristics of heat exchangers which consist of a gas cooler, an evaporator and an internal heat exchanger have been investigated at various operating conditions of $CO_2$ air conditioning system by experiments. The heat exchangers were designed for use in the vehicle $CO_2$ air conditioning system, when considering the characteristics of heat transfer and high pressure as $CO_2$ refrigerant. This paper studied the performance of heat exchangers at various compressor speeds and expansion valve openings, and quantified the heat transfer rates and pressure drops. Heat transfer rates at the gas cooler and the evaporator were 6.9 kW and 5.2 kW, respectively, when the compressor speed was 4000 rpm and refrigerant vapor quality at the evaporator outlet was 0.98. Therefore, this paper carried out that the heat exchangers were analyzed to achieve superior performance for the vehicle transcritical $CO_2$ cycle.

Performance Characteristics of Water-Chilling Heat Pump Using CO2 on the Variation of Secondary Fluid Conditions (2차 유체 조건 변화에 대한 CO2용 수냉식 열펌프의 성능 특성에 관한 연구)

  • Son, Chang-Hyo;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.543-551
    • /
    • 2007
  • The performance characteristics of water-chilling heat pump using $CO_2$ with respect to variation of inlet temperature and mass flow rate of secondary fluid was investigated experimentally. An experimental apparatus is consisted of a compressor, a gas cooler, an expansion valve, an evaporator and a liquid receiver. All heat exchangers used in the test rig are counter-flow-type heat exchangers with concentric dual tubes, which ate made of copper. The gas cooler and the evaporator consist of 6 and 4 straight sections respectively arranged in parallel, each has 2.4 m length. The experimental results were summarized as the followings : As inlet temperature of secondary fluid in the gas cooler increases from $10^{\circ}C$ to $40^{\circ}C$, the compressor work, heating capacity and heating COP were varied to 37.8%, -13%, -35.9%, respectively. The heating capacity, compressor work, heating COP were turned into 23.3%, 6.42%, 13.1%, respectively when ass flow rate of secondary fluid in the evaporator increases from 70 g/s to 150 g/s. The above tendency is similar with performance variation with respect to temperature variation of secondary fluid in the conventional vapor compression cycle.