• 제목/요약/키워드: Gas circuit breaker

검색결과 145건 처리시간 0.043초

Gas 색연(絶綠) 개폐장치(開閉裝置)의 철공진(鐵共振) 제어대책(制御對策)에 관한 연구(硏究) (A Study on the Elimination of Temporary overvoltage Due to Ferroresonance at Gas Insulated Switchgear)

  • 김승규;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 영호남학술대회 논문집
    • /
    • pp.216-221
    • /
    • 2000
  • This paper describes the analysis results on the PT ferroresonance at 154 kV GIS (gas Insulated substation by EMTP(Electro- magnetic Transient Program). We had simulated the PT ferroresonance between a potential transformer(PT) and an open circuit breaker's grading capacitance. The ferroresonance leads to very large power frequency overvoltages on PT bus and subsequent insulation failure. The large power can be supplied to the PT by the high voltage on the opened circuit due to the grading capacitance and equivalent capacitance of the buses during the ferroresonance. The damping circuit connected on the secondary winding were considered in the model. The actual countermeasure include a saturable inductor and a resistor series-mounted, but the 2 ohms of damping resistance was used in the computationl model.

  • PDF

가스차단기의 소전류 차단성능 향상을 위한 유동해석 (Flow Analysis of Gas Circuit Breakers for Developing the Small Current Interruption Performance)

  • 이종철;최종웅;강성모;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1961-1965
    • /
    • 2003
  • The flow analysis is needed to verify the physical phenomena through interruption processes for improving the capacity and the reliability of gas circuit breakers. Moreover the small current interruption performance of GCBs could be predicted by coupling the flow characteristics with the electric field one. In this paper, the unsteady flow characteristics and the traveling trajectory are depicted with a commercial CFD code, PHOENICS, programmed for moving motion of objects. In order to validate computational results, the measured pressure data in cylinder and in front of arcing contact are compared with the test results of small current interruption.

  • PDF

저압 배선용차단기 절연회복특성 파악을 위한 절연회복전압 측정기법 연구 (Study on Measurement Method of Dielectric Recovery Voltage to analysis Dielectric Recovery Characteristic of Molded Case Circuit Breaker)

  • 송태헌;조영만;고광철
    • 조명전기설비학회논문지
    • /
    • 제29권8호
    • /
    • pp.49-54
    • /
    • 2015
  • Molded Circucit Breaker(MCCB) is a most widely used device to protect loads from the over-current in low power level distribution system. When the MCCB interrupts the over-current, the arc discharge occurred between fixed contact and moving contact to create hot gas. By the Lorentz force due to arc current, the occurred arc is bent to the grids. The grids extend and cool and divide it for arc extinguish. In the majority cases, the MCCB protects loads by interrupting the over-current successfully but in some cases the re-ignition is occurred by hot-gas created during process of interruption. The re-ignition arises when the recovery voltage(RV) is more higher than the recovery strength between contacts and it leads to interruption fault. Therefore to find out the dielectric recovery characteristics of protecting device has a great importance for preventing interruption fault. In this paper, we studies measurement method of the dielectric recovery characteristics considering inherent attribute of the MCCB. To measure the dielectric recovery characteristic of MCCB, we makes an experiment circuit for applying the over-current and the randomly recovery voltage. The measurement methode to find out the dielectric recovery voltage of the MCCB was established and the result was based on experiment results.

CFD-CAD 통합해석을 이용한 전력기기 온도상승 예측 (Prediction of temperature rise of Electric Switching Device Using CFD-CAD Integrated Analysis)

  • 안희섭;이종철;최종웅;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.808-810
    • /
    • 2002
  • Higher current-rating and improved thermal performance are being sought for existing medium-voltage vacuum circuit breakers(VCB) in order to meet market needs which require to be compact and downsized. In this paper, thermal performance of medium voltage vacuum circuit breaker was investigated through experiments and numerical analysis. We changed several major parameters of current-rating and heat sink affecting on thermal behaviors in the breaker and observed the results. To predict the temperature distribution in complex three-dimensional (3-D) VCB components and gas, the commercial package was used to simulate conjugate heat transfer. Although some assumptions and simplifications were introduced to simulate the model, results from the computational model were in good agreement with actual temperature rise measurements obtained from experiments.

  • PDF

측정 위치에 따른 GIS에서 VFTO 상승률 분석 (Analysis of Rate-of-rise of VFTO in GIS according to Measurement Point)

  • 오윤식;서훈철;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.519-520
    • /
    • 2011
  • In Gas Insulated Substation(GIS), Very Fast Transient Overvoltages(VFTOs) are generated by the switching operation of disconnector or circuit breaker and it is propagated to each component of GIS. Each component of GIS is modeled by lumped line model and distributed line model based on equivalent circuits. The various cases which can be operated and the various closing point-on-wave are considered. In this paper, magnitude and rate-of-rise of VFTO are simulated and analyzed by comparing the simulation results. Measurements are performed at transformer and circuit breaker.

  • PDF

154kV 전력계통 가스차단기(GCB) 소손원인 조사분석 (Damage Cause Analysis for GCB of 154kv Power Plant)

  • 이은춘;신강욱;홍성택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.425-427
    • /
    • 2000
  • The purpose of this study is to find the cause of the damage to the GCB(Gas Circuit Breaker), since the GCB of the 154kV power plant at the Hap-Cheon Dam has already been damaged twice. We researched the characteristics of this class of circuit breaker and the possible causes for this type of damage to the GCB using the FTA(Fault Tree Analysis) Method. We studied the optimal maintenance method of the GCB, the stability analysis and power serge protection of Hap-Cheon Dam, and the power serge and fault list of the power transmission line to help prevent a reoccurrence of the problem.

  • PDF

대전류 영역에서의 가스차단기 내의 아크의 자발적인 흐름현상에 따른 에너지 전달의 수치적 해석 (The Study on the Self-Flow Generation Phenomena in a Gas Circuit Breaker)

  • 최재원;최승길;강형부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1837-1839
    • /
    • 1997
  • This study presents the energy transfer of thermal arc in the circuit breaker with self-generation flow without puffer action. The phenomenon of pressure increase in the cylinder which encloses fixed contact was focused on and rising current stage was considered. Temperature and velocity of arc plasma were calculated by using energy balance equation and the amount of energy transfer due to convective flow was calculated.

  • PDF

하이브리드 아크모델을 이용한 초고압 가스차단기의 아크특성 해석 (Analysis of arc characteristics of EHV class GCB using hybrid arc model)

  • 박경엽;송기동;신영준;장기찬;송원표;권기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.94-96
    • /
    • 1997
  • A mathematical model (hybrid arc model) for arc behaviour in an $SF_6$ puffer gas-blast circuit-breaker has been developed. It has adopted the advantages of integral method and differential method. The method has been applied to model puffer circuit breaker of Noeske et al and good agreement of critical RRRV(Ratio of Rise of Recovery Voltage) has been obtained. Axial or radial distributions of temperature, electric field and arc radius are also presented and analyzed.

  • PDF

25.8kV 2000A GCB용 개스붓싱 개발 (The Development of Gas Bushing for 25.8kV/2000A GCB)

  • 김정배;송원표;이철현;노철옹;최진용;장원율
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1385-1387
    • /
    • 1994
  • For the development of the 25.8kV outdoor GCB (Gas - Circuit - Breaker), which have a surge surpression performance in closing & opening of circuit and a high reliability performance, we have developed the 25.8kV gas bushing first of all in KOREA. After manufacturing of 25.8kV/2000A gas bushing, we carried out the dimension & visual test and electrical & mechanical test and we have got the favorable test-results. And it was put together real outdoor GCB, and then we carried out type test at KERI and have confirmed the performance of this bushing.

  • PDF

직렬-복합소호형 모델 가스차단기의 차단성능평가 (Estimation of Interruption Capability of a Serial-Hybrid Type Model Gas Circuit Breaker)

  • 송기동;정진교;박경엽
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권9호
    • /
    • pp.538-544
    • /
    • 2004
  • This paper presents the interruption capability of serial-hybrid type GCB (gas circuit breaker) compared with that of puffer type. First a puffer type model interrupter which has the stroke length of 80 mm has been designed and manufactured. And also, a serial-hybrid type interrupter which has the same design parameters as the puffer type interrupter except the serially arranged thermal-expansion chamber and puffer cylinder has been fabricated. Using a simplified synthetic test facility, the critical interruption capabilities of the two GCBs have been estimated. The critical di/dt, the critical dV/dt of ITRV (initial transient recovery voltage) and the minimum arcing time of the puffer type model GCB were 10.7 A/${\mu}\textrm{s}$, 5.5 kV/${\mu}\textrm{s}$, and 15.0 ms respectively. In the case of serial-hybrid type model GCB, each of the values was 16.6A/${\mu}\textrm{s}$, 11.5 kV/${\mu}\textrm{s}$ and 13.0 ms. As a conclusion of this work, it has been quantitatively confirmed that the hybrid type interrupter can obtain the sufficient interruption capability at the operating force which is so low that puffer type interrupter has not the interruption capability.