• Title/Summary/Keyword: Gas chromatography-mass spectrometer

Search Result 106, Processing Time 0.026 seconds

Determination of N-nitrosamines in Water by Gas Chromatography Coupled with Electron Impact Ionization Tandem Mass Spectrometry (EI-GC/MS/MS를 이용한 니트로사민류의 수질분석)

  • Lee, Ki-Chang;Park, Jae-Hyung;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.11
    • /
    • pp.764-770
    • /
    • 2014
  • This study assessed analysis of N-nitrosamines by separation, identification, and quantification using a gas chromatography (GC) mass spectrometer (MS) with electron impact (EI) mode. Samples were pretreated by a automated solid phase extraction (SPE) and a nitrogen concentration technique to detect low concentration ranges. The analysis results by EI-GC/MS (SIM) and EI-GC/MS/MS (MRM) on standard samples with no pretreatment exhibited similar results. On the other hand, the analysis of pretreated samples at low concentrations (i.e. ng/L levels) were not reliable with a EI-GC/MS due to the interferences from impurity peaks. The method detection limits of eight (8) N-nitrosamines by EI-GC/MS/MS analysis ranged from 0.76 to 2.09 ng/L, and the limits of quantification ranged from 2.41 to 6.65 ng/L. The precision and accuracy of the method were evaluated using spiked samples at concentrations of 10, 20 and 100 ng/L. The precision were 1.2~13.6%, and the accuracy were 80.4~121.8%. The $R^2$ of the calibration curves were greater than 0.999. The recovery rates for various environmental samples were evaluated with a surrogate material (NDPA-$d_{14}$) and ranged 86.2~122.3%. Thus, this method can be used to determine low (ng/L) levels of N-nitrosamines in water samples.

Characteristics of PM2.5 Carbonaceous Aerosol using PILS-TOC and GC/MS-TD in Seoul (PILS-TOC 및 GC/MS-TD를 이용한 서울시 대기 중 초미세먼지(PM2.5) 유기탄소의 특성 분석)

  • Park, Da-Jeong;Ahn, Joon-Young;Shin, Hye-Jung;Bae, Min-Suk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.5
    • /
    • pp.461-476
    • /
    • 2014
  • Continuous Water-Soluble Organic Carbons (WSOC) by the Particle Into Liquid Sampler - Total Organic Carbon (PILS-TOC) analyzer were measured at the Seoul intensive monitoring site from June 17 through July 5 in 2014. In addition, the 24 hour integrated PM2.5 collected by Teflon and Quartz filters were analyzed for water soluble ions by Ion chromatography (IC), WSOC by TOC from water extracts, organic carbon (OC), elemental carbon (EC) by carbon analyzer using the thermal optical transmittance (TOT) method, and mass fragment ions (m/z) related to alkanes and PAHs (Poly Aromatic Hydrocarbons) by Gas Chromatography-Mass Spectrometer-Thermal Desorption (GC/MS-TD). Based on the statistical analysis, four different Carbonaceous Thermal Distributions (CTDs) from OCEC thermal-gram were identified. This study discusses the primary and secondary sources of WSOC based on the Classified CTD, organic mass fragments, and diurnal patterns of WSOC. The results provide knowledge regarding the origins of WSOC and their behaviors.

Development of chemical ionization method in a GC-TOF mass spectrometer for accurate mass and isotope ratio measurement (Accurate mass 및 isotope ratio 측정을 위한 GC-TOF 질량분석기에서의 화학적 이온화방법)

  • Chung, Joo-Hee;Na, Yun-Cheol;Hwang, Geum-Sook;Shin, Jeoung-Hwa;Ahn, Yun-Gyong
    • Analytical Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.15-23
    • /
    • 2011
  • An accurate mass and isotope ratio were determined using a gas chromatography/time of flight mass spectrometer in CI positive mode for the identification of unknown metabolites. High mass tune was used to improve the ion intensity of $[M+H]^+$. Chromatographic resolution and dynamic range enhancement were performed to obtain more reliable accurate masses and correct isotope abundance ratios. Average absolute errors of mass and isotope ratios for 24 reference metabolite -TMS (trimethylsilyl) derivatives were 6.8 ppm, 1.5% of (M+1/M ratio) and 1.7% of (M+2/M ratio), respectively. The correct formulas of twenty one compound were retrieved within top-2 hit from the heuristic algorithm for elemental composition using each accurate mass and isotope abundance ratio.

Analytical Methods of Levoglucosan, a Tracer for Cellulose in Biomass Burning, by Four Different Techniques

  • Bae, Min-Suk;Lee, Ji-Yi;Kim, Yong-Pyo;Oak, Min-Ho;Shin, Ju-Seon;Lee, Kwang-Yul;Lee, Hyun-Hee;Lee, Sun-Young;Kim, Young-Joon
    • Asian Journal of Atmospheric Environment
    • /
    • v.6 no.1
    • /
    • pp.53-66
    • /
    • 2012
  • A comparison of analytical approaches for Levoglucosan ($C_6H_{10}O_5$, commonly formed from the pyrolysis of carbohydrates such as cellulose) and used for a molecular marker in biomass burning is made between the four different analytical systems. 1) Spectrothermography technique as the evaluation of thermograms of carbon using Elemental Carbon & Organic Carbon Analyzer, 2) mass spectrometry technique using Gas Chromatography/mass spectrometer (GC/MS), 3) Aerosol Mass Spectrometer (AMS) for the identification of the particle size distribution and chemical composition, and 4) two dimensional Gas Chromatography with Time of Flight mass spectrometry (GC${\times}$GC-TOFMS) for defining the signature of Levoglucosan in terms of chemical analytical process. First, a Spectrothermography, which is defined as the graphical representation of the carbon, can be measured as a function of temperature during the thermal separation process and spectrothermographic analysis. GC/MS can detect mass fragment ions of Levoglucosan characterized by its base peak at m/z 60, 73 in mass fragment-grams by methylation and m/z 217, 204 by trimethylsilylderivatives (TMS-derivatives). AMS can be used to analyze the base peak at m/z 60.021, 73.029 in mass fragment-grams with a multiple-peak Gaussian curve fit algorithm. In the analysis of TMS derivatives by GC${\times}$GC-TOFMS, it can detect m/z 73 as the base ion for the identification of Levoglucosan. It can also observe m/z 217 and 204 with existence of m/z 333. Although the ratios of m/z 217 and m/z 204 to the base ion (m/z 73) in the mass spectrum of GC${\times}$GC-TOFMS lower than those of GC/MS, Levoglucosan can be separated and characterized from D (-) +Ribose in the mixture of sugar compounds. At last, the environmental significance of Levoglucosan will be discussed with respect to the health effect to offer important opportunities for clinical and potential epidemiological research for reducing incidence of cardiovascular and respiratory diseases.

Introduction of Korea Oil Identification System(KOIS) (우리나라의 해상유출물질 감식.분석기법 연구)

  • Lee, Y.S.;Lee, S.J.;Kim, C.S.;Oh, H.J.;Kim, H.G.
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.05a
    • /
    • pp.85-92
    • /
    • 2006
  • Crude oil is complex mixture if thousands of different organic compound formed from a variety of organic materials that are chemically converted under differing geological conditions over long periods of time. Also oil composition varies according to crude source, refining, processing, handling and storage. The oil fingerprint method is application if specific knowledge of petrochemicals and use if sophisticated analytical equipment and techniques to identify the source(s) if oil pollution. KCG currently utilizes four primary analytical techniques: Gas Chromatography (GC), Fluorescence Spectroscopy(FL), Infrared Spectroscopy(IR) and Gas Chromatography mass spectrometer(GC/MS). Of all these techniques, GC technique are most widely used Gas Chromatography is used as a primary analytical method because high reliableness, high separating efficiency and repeatability.

  • PDF

Isolation and Identification of Fungal Strains Producing Gibberellins from the Root of plants (식물뿌리내부에 존재하는 지베렐린 생산균 분리와 동정)

  • Rim, Soon-Ok;Lee, Jin-Hyung;Khan, Sumera Afzal;Lee, In-Jung;Rhee, In-Koo;Lee, Kyung-Soo;Kim, Jong-Guk
    • Microbiology and Biotechnology Letters
    • /
    • v.35 no.4
    • /
    • pp.357-363
    • /
    • 2007
  • 249 fungal strains were isolated from the roots of 26 plants, and the production of GAs was spectrophotometric ally examined. As a result 76 fungal strains were shown to produce GAs. Bioassay of culture broth from seventy six fungal strains producing GAs was carried out with waito-c rice, that is dwarf rice. The seventy six fungi with GAs-producing activity were incubated for seven days in 40 mL of Czapek's liquid medium at $30^{\circ}C$ and 180 rpm, and the culture broth of fungi were treated on the 2-leaf rice sprout. Fifteen of these showed plant growth promoting activity and the amount of each GAs in the medium was measured by Gas chromatographymass spectrometer (GC-MS). Nine of these fungi were also identified by genetic analysis of the nucleotide sequences in the internal transcribed spacer region of the ribosomal DNA.

GC/MS and its applications for the analysis of cosmetic produtcts (GC/MS와 화장품 분석의 응용)

  • 노경원
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.19 no.1
    • /
    • pp.1-19
    • /
    • 1993
  • Gas chromatography serves to separate the mixtures into its components, and mass spectrometer is used to analyzing of unknown compounds. But there are many problems the identification of horn compounds using by GC only. As this reason GC/MS a very powerful analyzing technique. Mass spectrometer consists of 1) inlet stem 2) ion source 3) Bass filter 4) detectors and 5) data system. There are two analyzing modes in the GC/MS, those are scan and SIM(selected ion mom toping) modes. Scan mode is used when analyzing unknown compounds and SIM mode al lows the mass spectrometer to detect specific compound with very high sensitivity. As GC/MS applications for the analysis of cosmetic products, volatile compounds in lotion, earn foundation and hair color, and carbon distribution of fatty acids in soap were performed. Also as a new sample pre-treatment technique, head space sampler/GC/MS introduced in order to analyze the volatile compounds in a toothpaste.

  • PDF

Estimation of Beef Freshness with Electronic Nose (전자코를 이용한 쇠고기의 신선도 예측)

  • 김기영;이강진;최규홍;최동수;손재룡
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.07a
    • /
    • pp.394-399
    • /
    • 2002
  • 국민소득의 증대와 함께 소비자의 고품질 농축산물에 대한 수요와 관심이 날로 증가하고 있다 이에 따라 안전하며 고품질인 농축산물을 소비자에게 공급하기 위하여 안전한 농축산물의 생산, 신선도 유지를 위한 유통구조의 개혁, 품질 및 안전성 평가기술개발을 위한 노력이 보다 더 요구되고 있다. 소비자가 믿고 구매하기 위해서는 농축산물에 대한 품질보증이 필수적이며 이를 위해서는 신속하고 정확한 품질 및 유해물질의 판정기술 개발이 필요하다. 많은 농축산물에 있어서 주요 품질인자인 숙도 및 신선도의 변화는 휘발성 화학물질로 이루어진 냄새의 변화로 나타나므로 이를 측정하여 품질 및 안전성을 간접적으로 판정할 수 있다 기존의 냄새에 의한 품질 판정은 판별전문가에 의한 관능평가법 또는 GC(Gas Chromatography)나 GC/MS(Gas chromatograph mass spectrometer)에 의하여 주로 이루어져 왔다. 하지만, 관능평가법의 경우 판별전문가의 개인적인 차이, 피로, 건강상태 등에 따라 판정의 객관성이 떨어질 우려가 있고, GC나 GC/MS를 이용할 경우 냄새분석에 많은 시간과 노력이 소요되는 문제점이 있다. (중략)

  • PDF

Determination of dichloroacetic acid and trichloroacetic acid in fresh-cut salads using gas chromatography-mass spectrometry (GC-MS를 이용한 신선편의 샐러드 중 dichloroacetic acid와 trichloroacetic acid의 분석)

  • Kim, Hekap;Lee, Seong-gyun;Yun, A-hyeon
    • Korean Journal of Food Science and Technology
    • /
    • v.51 no.1
    • /
    • pp.12-17
    • /
    • 2019
  • Dichloroacetic acid (DCAA) and trichloroacetic acid (TCAA) in fresh-cut salads available from the market were determined by gas chromatography-mass spectrometry (GC-MS). The target compounds in 3 g of acidified homogenates were extracted with 20 mL of methyl t-butyl ether (MTBE). The extract was concentrated to 1 mL and heated for 1 h at $55^{\circ}C$. The analytes were separated using a DB-1701 column and detected with a mass spectrometer. The method detection limit was approximately $6{\mu}g/kg$, and both analytical accuracy and precision were found to be satisfactory. The linearity of the calibration curves expressed as the coefficients of determination was >0.996. The analysis of seven samples using the established method showed that the four samples contained considerable amounts of analytes ($25.4-31.2{\mu}g/kg$ of DCAA and $18.8-46.1{\mu}g/kg$ of TCAA). These results raised a concern about the impact of fresh-cut salad consumption on human health.

Evaluation of pesticide residue analysis of dieldrin in soil using a high resolution gas chromatograph/mass spectrometer (HR-GC/MS)

  • Hwang, Jae-Bok;Park, Tae-Seon
    • Korean Journal of Agricultural Science
    • /
    • v.43 no.4
    • /
    • pp.634-640
    • /
    • 2016
  • The objective of this study was to evaluate the effectiveness of using HR-GC/MS for the rapid screening of dieldrin residues in soils. Persistent organic pollutants (POPs) of organochlorine pesticides such as dieldrin, were analyzed in sedimentary rock and granite rock collected from greenhouses, Niigata, Japan. Dieldrin remains in Japanese farming soils, more than 40 years after their use as insecticides was prohibited. The averages in soil moisture ranged from 2.79% to 7.20% in soils derived from sedimentary rock and from 25.59% to 31.40% in soils derived from granite rock. Mean concentrations of dieldrin residues in sedimentary rock and granite rock were $39.7ng\;g^{-1}$ and $40.51ng\;g^{-1}$, respectively. Dieldrin residue was detected at a slightly higher concentration in granite rock than sedimentary rock samples. There was no consistency between the two soils or between surface and subsurface soils. The coefficients of variation of the two soils were 10.6% and 8.7%, respectively. These results suggest that our high-resolution mass spectrometry detector (HR-GC/MS) is effective at analyzing residual organochlorine pesticides in soil. In order to increase the precision and sensitivity for chemical analysis of POPs, high-resolution gas chromatography coupled with a HR-GC/MS is highly recommended.