• 제목/요약/키워드: Gas Turbine-Generator

검색결과 207건 처리시간 0.023초

소형 가스터빈 엔진용 발전기 성능개선 및 모델링 연구 (A Study on the Performance Improvement and Modeling of Generator for Small Gas Turbine Engine)

  • 김인수;윤현로
    • 한국군사과학기술학회지
    • /
    • 제7권3호
    • /
    • pp.174-183
    • /
    • 2004
  • In this paper, the performance improvement and modeling of small onboard generator were described. As the characteristics of the field coil which are a major parameters of generator were improved, the system bandwidth could be increased, therefore the generator could also be satisfied with fast characteristic loads. Established the brief control model of the generator, it could be possible to do the analysis of generator performance, and improve the operational stability of the generator system using the control model.

열회수 증기발생기의 최적설계에 대한 연구(I) (Optimum Design of a Heat Recovery Steam generator(I))

  • 신지영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권5호
    • /
    • pp.670-678
    • /
    • 1999
  • Heat recovery steam generator(HRSG) is a principal component of the combined cycle power plant (CCPP) which utilizes the waste energy of the gas turbine exhaust gas. A design of the HRSG is a keypoint to achieve high cycle efficiency with competitive cost. This paper presents a brief review on the design of a HRSG which covers the basic design parameters and their effects on the performance and the investment cost. Finally the concept of the optimum design point is presented according to the selection of a pinch point temperature difference and a steam pressure as an illustrated case.

  • PDF

200MW급 가스터빈 조속기 응답특성에 대한 연구 (A Study on the Response Characteristics of 200MW Gas Turbine Governor System)

  • 한영복;남강현;김성호
    • 한국전자통신학회논문지
    • /
    • 제17권4호
    • /
    • pp.625-632
    • /
    • 2022
  • 국내 전력계통에 부하추종운전 중인 가스터빈 발전기들은 정격 주파수 유지에 큰 역할을 하고 있지만 종종 주파수 제어가 불량한 경우도 발생한다. 이에 가스터빈 속도제어 장치인 조속기의 제어 특성을 살펴보고 고장 유형을 분석한 후 사안 별로 대책을 제시하였다. 그리고, 가스터빈은 연료제어의 빠르기에 따라 주파수 회복에는 도움을 되지만 연소실 온도가 급격하게 변동하고 연소진동이 발생하는 등 안정운전을 저해하는 요소로 작용하기도 한다는 것을 조속기 응동시험을 통해 확인하였다. 따라서, 안정적인 전력품질을 유지하기 위해서는 철저한 설비관리를 수행하고 비례 적분 미분 제어방식에 4차산업의 핵심분야인 기계학습 알고리즘이 융합된 조속기 제어방식의 연구 필요성이 대두되었다.

절연파괴 사례분석을 통한 진공함침 방식 발전기 고정자권선의 절연특성 연구 (A Study on Insulation Property of VPI Type Generator Stator Winding Through the Case Analysis of Insulation Breakdown)

  • 공태식
    • 전기학회논문지P
    • /
    • 제59권3호
    • /
    • pp.311-316
    • /
    • 2010
  • According to increase of combined cycle power generation, the manufacturing market of gas turbine generator has become more competitive, so there is high pressure on the manufacturer to reduce generator price. Global VPI(vacuum pressure impregnation) method is effective to save the production cost and time for manufacturing stator windings, but it has an abrasion problem by vibration between stator windings and slots. This paper presents the insulation breakdown case, which is for VPI type generator during high voltage insulation tests, and also shows the cause analysis, repair works as well as reliability test. the purpose of this paper is to understand the insulation properties of VPI type generator and to know prevention of insulation weakness.

마이크로가스터빈 배열부하가 배가스흡수식 냉온수기의 성능에 미치는 영향 (Effect of the Exhaust Heat from Micro Gas Turbine on the Performance Characteristics of the Absorption Chiller)

  • 최경식;손화승;김형식;임상규;허광범
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.158-162
    • /
    • 2006
  • Micro gas turbine (MGT) has received attention recently as a small-scale distributed power source. Due to many advantages such as their small size, low maintenance cost and minimal vibrations during operation, they are expected to become widespread in a wide range of applications. The exhaust heat emitted by the MGT is in the form of an exhaust gas that is about $270^{\circ}C$ which is an extremely clean gas. Korea Gas Corporation (KOGAS) has researched performance characteristics of a cogeneration system combining 28kW class MGT and 13 USRT class absorption hot and chilled water generator in the local condition. The present results of this study can be summarized as follows: (1) in heating mode, the total efficiency of cogen. system is about $65\%$ and heating capacity is 33kW at 25kW MGP power (2) in cooling mode, COP is about 0.6 at 22kW MGT power.

관류형 열회수 증기발생기와 증기터빈 시스템의 성능해석 (Performance Analysis of Once-through HRSG and Steam Turbine System)

  • 양진식;김동섭;노승탁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.872-877
    • /
    • 2001
  • This study analyzed the design performance of the bottoming system of combined cycle power plants adopting a single-pressure once-through heat recovery steam generator with reheat. A computer program was constructed and parametric analyses were carried out to present the criteria for determining the reheat pressure and the location of the starring point of the reheater in the HRSG. The performance of the bottoming system was presented for the range from high subcritical to supercritical pressures. It was founded that the power of the bottoming system can be as high as that of the present triple-pressure bottoming system even with a higher exhaust gas temperature. A requirement for this high performance is a proper arrangement of the reheater.

  • PDF

농후 연소 가스발생기의 비평형 연소 화학반응 모델링 (Modeling of Non-Equilibrium Kinetics of Fuel Rich Combustion in Gas Generator)

  • 유정민;이창진
    • 한국항공우주학회지
    • /
    • 제34권7호
    • /
    • pp.89-96
    • /
    • 2006
  • 액체 로켓의 가스발생기의 연소 온도는 터빈 깃의 열 손상을 방지하기 위하여 1,000K 이하로 유지되며 이를 위하여 농후 연소 또는 산화제 과다 연소를 유지한다. 이러한 이유로 연소는 비평형 화학반응이 주로 발생하며 연소반응을 예측하기가 매우 어렵다. 한편 케로신은 여러 가지 탄화수소 연료로 이루어진 혼합연료로 화학반응 메커니즘에 대한 모델이 매우 어려운 실정이다. 본 연구에서는 Dagaut가 개발한 207 화학종, 1592 화학반응 단계를 이용하였으며 완전혼합반응기 연소모델을 적용하여 계산하였다. 계산결과와 실험결과를 비교하여 보면 사용된 화학반응 기구가 검댕 예측을 하지 않고 있음에도 불구하고 계산 결과는 연소가스 온도 뿐 아니라 가스 물성치 등을 매우 잘 예측하고 있음을 확인하였다.

발전기 회전자 층간단락 감지기 국산화 개발 (Development of Shorted Turn Sensor for Generator Rotor)

  • 이영준;김회동;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.195-197
    • /
    • 2001
  • The shorted-turn sensor for generator's field winding has been developed. The sensor, installed in the generator air-gap, senses the slot leakage flux of field winding and produces a voltage waveform proportional to the rate of change of the flux. For identification of reliability for sensor, a shorted-turn test was performed at the Seoinchon & Sininchon combined cycle power plant on gas turbine generator. This sensor will be used as a detecting of shorted-turn for generator's field winding.

  • PDF

발전기 계자의 층간단락 감지기 개발 (Development of Shorted-Turn Sensor for Generator Rotor)

  • 이영준;김희동;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1765-1767
    • /
    • 2001
  • The shorted-turn sensor for generator's field winding has been developed. The sensor, installed in the generator air-gap, senses the slot leakage flux of field winding and produces a voltage waveform proportional to the rate of change of the flux. For identification of reliability for sensor, a shorted-turn test was performed at the Seoinchon combined cycle power plant on gas turbine generator. This sensor will be used as a detecting of shorted-turn for generator's field winding.

  • PDF

동기발전기 계자권선의 층간단락 감지센서 개발 (Development of Shorted-Turn Sensor for Synchronous Generator's Field Winding)

  • 조지원;이병하;이영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2114-2116
    • /
    • 1999
  • The shorted-turn sensor for synchronous generator's field winding has been developed. The sensor, installed in the generator air-gap, senses the slot leakage flux of field winding and produces a voltage waveform proportional to the rate of change of the flux. For identification of reliability for sensor, a shorted-turn test was performed at the Seoinchon combined cycle power plant on gas turbine generator. This sensor will be used as a detecting of shorted-turn for synchronous generator's field winding.

  • PDF