• Title/Summary/Keyword: Gas Sterilization

Search Result 69, Processing Time 0.021 seconds

A Comparison of Minilaparotomy and Laparoscopic Sterilization (Minilaparotomy 불임술(不妊術)과 복강경불임술(腹腔鏡不妊術)에 관(關)한 비교연구(比較硏究))

  • Bai, Byoung-Choo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.4 no.1
    • /
    • pp.17-25
    • /
    • 1977
  • Anderson(1937), Power and Barnes(1941) reported a study concerning a method of tubal sterilization in association with peritoneoscopy or laparoscopy in which they cauterized the tubes. There appears to have been a hiatus of interest in sterilization (cold or hot) associated with laparoscopy until reintroduction by Palmer(1963), Frangenheim(1964) and Steptoe(1967). On the other hand, for interval female sterilization, however, minilaparotomy is relatively new. By Saunder and Munsick(1972), John Lyle(1974), Frank Stubb(1974), Vitoon(1973) and B.C. Bai(1975), their own technique for interval female sterilization requires 2.0 to 2.5cm, incision at the margin of the mons pubis. In Korea, female sterilization by means of minilaparotomy firstly reported by B.C. Bai using Bai's uterine elevator, of his own device, early in 1975. Recently inteval female sterilization by laparoscopy and minilaparotomy are widely accepted throughout the world especially in Asian countries. Minilaparotomy is carried out from 1974, laparoscopic sterilization from 1976, and in this study each of 250 cases of those were analysed and discussed for the comparison at Seoul Red Cross Hospital. (1) In the age distribution, numerous clients were in their age of $31{\sim}35$ in laparoscopy as well as minilaparotomy. Average 33.7 years in L and 33.2 years in M. (M=minilaparotomy, L=laparoscopic sterilization) (2) As regarding living children, women having 3 children represented the greatest number, 113 cases out of 250 in M group and 102 cases out of 250 in L group. Average No. of child are 2.9 in Land 3.1 in M. (3) Concidering the operation day in the menstrml cycle, the greatest number of cases, those who underwent tubal sterilization during the days of $26{\sim}$, next during the $6{\sim}10$ days of the cycle in both group. (4) Concidering the operation time, 188 cases by laparoscopy were performed in $6{\sim}10$ minutes, 33 cases within 5 minutes and 24 cases in $11{\sim}15$ minutes. Maximum 50 minutes, minimum 4 minutes and average 8.3 minutes. The majority of cases (154 cases) by minilaparotomy required $6{\sim}10$ minutes and 67 cases $11{\sim}15$ minutes, 6 cases within 5 minutes. Maximum 30 minutes, minimum 4 minutes and average 10.4, minutes. In both groups, most of the reasons for the extra length were surgical difficulties such as thick abdominal wall, pelvic adhesion, less cooperation of patients in early period of this study. (5) Hospital stay after operation in L group required $3{\sim}4$ hours in 125 cases, $2{\sim}3$ hours in 41 cases, $4{\sim}5$ hours in 32 cases out of 250. Maximum 8 hours, minimum 1 hour and average 3.8 hours. In M group hospital stay required $6{\sim}7$ hours in 100 cases, over 7 hours in 85 cases, $5{\sim}6$ hours in 46 cases and so on. Maximum 14 hours, minimum 2 hours and average 6.5 hours. (6) The time between operation and gas passing in the majority cases of both groups, were $12{\sim}36$ hours. A veragetime 20.3 hours in L and 27.2 in M. (7) Laparoscopic sterilization coincident with induced abortion were carried out in 27 cases, laparoscopy with minilaparotomy to control for mesosalpingeal hemorrhage in 1 case. Minilaparotomy coincident with induced abortion were performed in 65 cases, D and C whit polypectomy, menstrual regulatian, and remaval of IUD in 1 case respectively. (8) In L group, 1 case of mesosalpingeal hemorrhage, 1 case of abdominal wall infection were complicated during operation. In M group, 1 case of uterine perfaration, 1 case of abdominal wall infection, 1 case of hemorrhage from omentum and 1 case of bloody vaginal discharge were complicated. No intensive medical treatment was required for those minor complications in both groups. (9) No failure has been recognized and these two sterilization techniques might be the simple, safe and the most effective method for permanent contraception at present time. There is no significant clinical defference between L and M group in this study.

  • PDF

A Study on the Ralstonia Solanacearum Inactivation using Improved Plasma Process (개선된 플라즈마 공정을 이용한 Ralstonia Solanacearum 불활성화에 관한 연구)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.23 no.3
    • /
    • pp.369-378
    • /
    • 2014
  • Effect of improvement of the dielectric barrier discharge (DBD) plasma system on the inactivation performance of bacteria were investigated. The improvement of plasma reactor was performed by combination with the basic plasma reactor and UV process or combination with the basic plasma reactor and circulation system which was equipped with gas-liquid mixer. Experimental results showed that tailing effect was appeared after the exponential decrease in basic plasma reactor. There was no enhancement effect on the Ralstonia Solanacearum inactivation with combination of basic plasma process and UV process. The application of gas-liquid mixing device on the basic plasma reactor reduced inactivation time and led to complete sterilization. The effect existence of gas-liquid mixing device, voltage, air flow rate (1 ~ 5 L/min), water circulation rate (2.8 ~ 9.4 L/min) in gas-liquid mixing plasma, plasma voltage and UV power of gas-liquid mixing plasma+UV process were evaluated. The optimum air flow rate, water circulation rate, voltage of gas-liquid mixing system were 3 L/min, 3.5 L/min and 60 V, respectively. There was no enhancement effect on the Ralstonia Solanacearum inactivation with combination of gas-liquid mixing plasma and UV process.

Study on the Shelf Life of Sterilized Products according to Packaging Materials (포장재에 따른 멸균품의 유효기간에 관한 연구)

  • Chang, Song Ja;Jeong, Jeong Hee;Choi, Kyoung Mi;Kim, Mi Young;Park, Joo Hee;Jeong, Na Yeon
    • Journal of Korean Clinical Nursing Research
    • /
    • v.25 no.3
    • /
    • pp.333-341
    • /
    • 2019
  • Purpose: The purpose of this study was to determine the most appropriate shelf life for sterilized products according to their packaging material. Methods: Samples were prepared to target six nursing units in one general hospital in Seoul. After steam and E.O gas sterilization, sterilized product, samples were supplied to wards. Data collection was conducted for 3 months, after the expiration date of 3 months had passed for samples packaged with crepe paper and nonwoven wraps. For samples packaged with paper-plastic pouches, data collection conducted for 3 months when the expiration date of 9 months had passed. The sterilized products were collected and tested for microbial contamination. Identification of the storage environment was done as samples were collected. Results: This study confirmed that the storage environment met international standards such as CDC, except for temperature. For steam sterilized crepe paper packaging samples and steam and E.O gas sterilized for nonwoven packaging samples no contamination in all products was found for 3 months past the expiration date. However, in the E.O gas sterilized paper-plastic pouch packaging sterile samples, Gram-positive bacilli were detected in one sample from a surgical intensive care unit at 45 weeks and another sample from an operating room at 47 weeks. Furthermore, the results did not show any microorganisms for up to 52 weeks in all products. Conclusion: According to the results of this study, sterilized product packaging made with crepe paper and nonwoven wraps is better able an extended shelf life from 3 months to 6 months, reducing unnecessary costs.

Comparative study on bone regeneration between silk mat incorporated 4-hexylresorcinol and collagen membrane

  • Seok, Hyun;Jo, You-Young;Kweon, HaeYong;Baek, Dong-Heon;Kim, Seong-Gon
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.34 no.2
    • /
    • pp.32-37
    • /
    • 2017
  • The purpose of this study was (1) to demonstrate the anti-microbial properties of 4-hexylresorcinol (4HR) loaded silk mat and (2) comparison of bone formation between 4HR incorporated silk mat and collagen membrane. Anti-microbial properties of 4HR incorporated silk mat was done after sterilization of silk mat (autoclaving and ethylene oxide gas). For the evaluation of bone formation, bilateral bony defects (size: 8 mm) were prepared in the parietal bone of the rabbits (n=10). 4HR incorporated silk mat (size: $10{\times}10mm$) was applied on the right defect. For the comparative purpose, the same size of commercial collagen membrane was applied on the left defect. The anti-microbial properties of 4HR incorporated silk mat were maintained after sterilization process. When compared bone mineral density and bone volume, there was no statistically significant difference between groups at 4 weeks and 8 weeks after operation (p>0.05). In conclusion, 4HR incorporated silk mat could be autoclaved without concern of anti-microbial properties loss. In addition, 4HR incorporated silk mat showed similar bone regeneration to collagen membrane. Therefore, 4HR incorporated silk mat might be considered for the application of open membrane technique.

Analysis of Volatile Components of a Chicken Model Food System in Retortable Pouches (레토르트 파우치 계육 모형식품의 휘발성분 분석)

  • Choi, Jun-Bong;Chung, Ha-Yull;Kong, Un-Young;Moon, Tae-Wha
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.4
    • /
    • pp.772-778
    • /
    • 1996
  • In order to investigate changes of flavor during food sterilization in retortable pluches, a model food system consisting of 50% chicken breast meat, 1% salt and 49% chicken stock was analyzed before and after retorting using GC and GC-MS. In the analysis of the volatile components collected by the nitrogen purge and trap technique before and after retorting, a total of 53 peaks were observed on chromatograms and 42 peaks were identified. Among the 42 peaks identified were 17 caused by aldehydes, 9 by hydrocarbons, 8 by alcohols, 6 by ketones, 1 by furan and 1 by terpene. Analysis of the data obtained from our model food system strongly suggested that the compounds responsible for retort flavor are 2-heptanone, 2-pentyl furan and various ketones.

  • PDF

A Study on the Degree of Contamination of Air and Materials in a Hospital (병원내 공기오염과 물품의 항균에 대한 상태조사)

  • 차옥주
    • Journal of Environmental Health Sciences
    • /
    • v.8 no.1
    • /
    • pp.25-30
    • /
    • 1982
  • The incidence of hospital infection has been seriously increased in the general hospital in recent years. This study was performed on hospital air and materials in a General Hospital in Seoul from June to December in 1980. The results were as follows: 1. Air sampling was done in multiple strategic areas by exposing standard petridishes for 5 minutes. There was a significant difference of airborne microbe between places. ($F._{99}$ = 3.2, p < 0.01). 2. The mean colony count was 8.6$\pm$6.2 colonies / plate / 5 minutes. 3. Gram stains of colony in air sampling were Gram (+) cocci 66.5%. Gram (+) rod 18.4%, Gram (-) cocci 1.3%, Gram (-) rod 8.7% Fungus 4.5%. 4. For the evaluation of sterilization of steam sterilizer and ethylene oxide gas sterilizer, biological monitoring were done by commercial spore strip. Positive culture was obtained in 2 out of 41 tests on 3 steam sterilizers, and in 3 out of 13 tests on ethylene oxide gas sterilizer. 5. Product sampling and culture were done for 2 kinds of disinfectants and 30 sets of various operation package or dressing materials. Positive culture was obtained in one disinfectants.

  • PDF

Study on Micro-bubble Generation Characteristics in Venturi Cavitation using Laser Diffractometer (레이저 회절 측정기를 이용한 벤츄리 캐비테이션에서의 마이크로버블 발생 특성 연구)

  • Lim, Yun Gyu;Yang, Hae Jeong;Kim, Yung Il
    • Journal of Drive and Control
    • /
    • v.16 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • The use of micro bubbles in industrial fields has been increasing in the recent years., particularly micro-bubble sterilization and water purification effects. Various methods have been developed for the generation of micro-bubbles. Depending on the method of generating bubbles, the micro-bubbles can be roughly classified into saturation molding, cavitation and rotation flow types. The objective of this study was to use ventilated tube type as a method of generating micro-bubbles in order to purify large amount of water quality such as lakes and reservoirs. This method shows a difference in efficiency in which micro-bubbles are generated depending on the contact ratio of gas to liquid. The study also investigated the optimal gas liquid contact ratio by applying various orifice methods and investigated the optimum condition of micro-bubble generation by gas Based on this, a technology to develop a micro-bubble generator with a venturi type nozzle shape that has a high water purification effect was developed.

Control of Generation of Chlorine Dioxide Gas Using Polymer Hydrogels Containing Acetic Acid (아세트산이 탑재된 고분자 수화젤을 이용한 이산화염소 기체의 발생 제어)

  • Lee, Dong-Han;Lee, Ook
    • Polymer(Korea)
    • /
    • v.37 no.5
    • /
    • pp.553-556
    • /
    • 2013
  • Chlorine dioxide gas has an excellent ability for sterilization and deodorization, and is harmless to humans. However, it is very unstable and explosive as it is highly concentrated, thus its use in the air clean fields has been limited. Therefore, there is need to control chlorine dioxide gas at a low concentration for a long time. Chlorine dioxide gas could be produced slowly and sustainedly since the release of acetic acid from the polymer hydrogels delayed the reaction between acetic acid and sodium chlorite. In addition, as the amount of both acetic acid sodium chlorite loaded within the hydrogel and on the membrane increased, respectively, the generation amount of chlorine dioxide gas increased. The result shows that the use of polymer hydrogels has the potential to control the generation of chlorine dioxide gas.

One-Plate Type Hybrid Plasma Discharge Device with Heating Element (히터 일체형 하이브리드 단판형 플라즈마 방전소자)

  • Choi, Woo Jin;Choi, Eun Hye;Sung, Hyeong Seok;Kwon, Jin Gu;Lee, Seong Eui
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.4
    • /
    • pp.320-326
    • /
    • 2019
  • Recently, the application of atmospheric plasma technology in air filtration is increasing. Sterilization by an atmospheric plasma device is very effective. However, ozone gas, which is generated during atmospheric plasma formation, poses a hazard to human health. To reduce the ozone gas during plasma discharge, we fabricated a one-plate hybrid plasma discharge device with a heating element, which can decompose ozone gas effectively by a simple heating action. In this study, we evaluated the plasma discharge characteristics and ozone concentrations with various Ar flow rates and temperatures. With increasing Ar gas flow rate, the ozone concentration and spectrum intensity increased till an Ar gas flow rate of 60 sccm, and decreased thereafter. When discharged in high temperature, the ozone concentration and spectrum intensity decreased. Further, to evaluate the state of the treated surface under various plasma discharge and heating conditions, we measured the variation in the contact angles on the surface. Regardless of the temperature, the contact angle increased with increasing discharge voltage. However, the contact angle increased when discharged at high temperature.

Determination of the mole fractions of ethylene oxide and freons in medical liquefied gas mixture by GC/AED (GC/AED를 이용한 의료용 액화혼합가스 중 산화에틸렌 및 프레온 가스류의 몰분율 측정)

  • Kim, Hyunjoo;Kim, Dalho;Lim, Arang;Lee, Taeck-Hong;Kim, Jin Seog
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.382-387
    • /
    • 2012
  • Ethylene oxide ($C_2H_4O$, EtO) is used as a raw material for the production of ethylene glycol and other industrially important material such as ethanolamines and also used as a disinfecting agent. It is applied for gas-phase sterilization of thermally sensitive medical equipment, and for processing of storage facilities as a mixture with fluorinated hydrocarbon. In this perspective, accurate determination of the mole fractions of components in the liquefied gas mixture is required for the quality control and safety of production and use. Each component of the liquefied gas mixture has different chemical and physical properties such as vapor pressure and boiling point. Therefore, we can suppose that analytical results can be different according to the introduction method for the gas phase of upper layer, or for the liquid phase of lower layer in gas cylinder. In this study, we designed a new on-line sample injection device for the liquefied gas mixture in liquid or gas state, and applied to the analysis of liquefied gas mixture of ethylene oxide and fluorinated hydrocarbons by GC/AED (gas chromatograph-atomic emission detector). We studied performance of AED, and effect of sample introduction and selected wavelength to the accuracy and repeatability of analytical results.