• Title/Summary/Keyword: Gas Sensors

Search Result 1,074, Processing Time 0.022 seconds

Thermal Characteristics Simulation with Detecting Temperature for the Wearable Nylon-Yarn NOx Gas Sensors (웨어러블용 Nylon-Yarn NOx 가스 센서의 검출 온도 변화에 따른 열 특성 시뮬레이션)

  • Jang, Kyung-Uk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.4
    • /
    • pp.321-325
    • /
    • 2020
  • Atmospheric environmental problems have a major impact on human health and lifestyle. In humans, inhalation of nitrogen oxides causes respiratory diseases, such as bronchitis. In this paper, thermal analysis of a gas sensor was carried out to design and fabricate a wearable nylon-yarn gas sensor for the detection of NOx gas. In the thermal analysis method, the thermal diffusion process was analyzed while operating the sensors at 40 and 60℃ to secure a temperature range that does not cause thermal runaway due to temperature in the operating environment. Thermal diffusion analysis was performed using the COMSOL software. The thermal analysis results could be useful for analyzing gas adsorption and desorption, as well as the design of gas sensors. The thermal energy diffusion rate increased slightly from 10.05 to 10.1 K/mm as the sensor temperature increased from 40 to 60℃. It was concluded that the sensor could be operated in this temperature range without thermal breakdown.

Characteristics and Preparation of CNT:ZnO Gas Sensors (CNT:ZnO 가스 센서의 제조와 특성 연구)

  • Yoon, So-Jin;Yu, Il
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.7
    • /
    • pp.468-471
    • /
    • 2014
  • The effects of ZnO coating on the sensing properties of CNT:ZnO based gas sensors were studied for $H_2S$ gas. The nano ZnO sensing materials were grown by hydrothermal reaction method. CNT:ZnO was prepared by ball-mill method. The mole range of nano ZnO coating on CNT surface was from 0 to 10%. The CNT:ZnO gas sensors were fabricated by a screen printing method on alumina substrates. The structural and morphological properties of the CNT:ZnO sensing materials were investigated by XRD, EDS, SEM and TEM. The XRD patterns showed that CNT:ZnO powders with hexagonal structure were grown with (002) dominant peak. The diameter of CNT from TEM was about 28 nm.

A ultrasonic technique for measuring gas temperature (기체온도 측정을 위한 초음파 계측)

  • Choi, Y.;Yoon, C. H.;Jeon, H. S.
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1998.10a
    • /
    • pp.150-160
    • /
    • 1998
  • Measuring temperature with ultrasonic wave apparatus is desirable in the case of both below 300$0^{\circ}C$ and ideal gas because of the fact that the temperature of gas is the function of only sound velocity. In this study, being used a heatable wind channel and a blower, the variation of temperature is observed in accordance with diverse flow rate(air velocity). The frequency modulation method is used to measure the temperature which is varying in hot air flow till 10$0^{\circ}C$. The length changed in the position of ultrasonic sensors is considered. Also, the effects of air velocity at the same temperature and various facing angles of ultrasonic sensors are considered. As a result of this study, it has been found that the temperature in gas flow is correctly measured regardless of both the distance of ultrasonic sensors and the variation of air velocity, and that there is just a little influence of facing angles.

  • PDF

A Study on Ultrasonic Technique for Measuring Gas Temperature (기체온도 측정을 위한 초음파 계측에 관한 연구)

  • Yoon, Cheon Han;Choi, Young;Jeon, Heung Shin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.7
    • /
    • pp.893-900
    • /
    • 1999
  • Measuring temperature with ultrasonic wave apparatus is desirable in the cue of gas below $300^{\circ}$ because of the fact that the temperature of gas is the function of only sound velocity. In this study, being used a heatable wind channel and a blower. the variation of temperature is observed in accordance with flow rate(air velocity). The frequency modulation method is used to measure the temperature which is varying in hot air flow up to $100^{\circ}$. The length changed in the position of ultrasonic sensors is considered. Also. the effects of air velocity at the same temperature and various facing angles of ultrasonic sensors are considered. As a result of this study. it has been found that the temperature in gas flow is correctly measured regardless of both the distance of ultrasonic sensors and the variation of air velocity. and that there is just a little influence of facing angles.

Research Progress in Membrane and Catalyst for Highly Selective Chemiresistive Gas Sensors (저항변화식 가스센서 선택성 향상을 위한 멤브레인 및 촉매 연구동향)

  • Jang, Ji-Soo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.1
    • /
    • pp.11-17
    • /
    • 2022
  • Direct exposure to toxic and hazardous gases has always been considered as the most pervasive problem worldwide, leading to a gradual increase in the number of asthma patients due to NOx/SOx gases inhaling and exposure to 50 ppm formaldehyde gases. Therefore, the development of accurate gas sensors is a key issue for resolving these problems. To address such issues, the development of membranes for selective filtering of target molecules as well as nanocatalyst for enhancing the sensing selectivity is highly crucial. In this review, the research progress for porous membrane materials (e.g. MOFs, and graphene) and nanocatalyst technology for the development of selective and accurate gas sensors will be discussed.

Development and Field Test of a Smart-home Gas Safety Management System (스마트 홈 가스안전관리 시스템 개발 및 현장시험)

  • Park, Gyou-Tae;Kim, Eun-Jung;Kim, In-Chan;Kim, Hie-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.128-135
    • /
    • 2012
  • In this paper, we proposed a system and a scenario to raise efficiency of gas safety management by developing wireless ZigBee communication modules, smart-home gas safety appliances and the system suitable for gas safety. Our designed system consists of a micom gas meter, an automatic extinguisher, sensors, and a wall-pad. A micom-gas-meter monitors gas flow, gas pressure, and earthquake. An automatic fire extinguisher checks combustible gas leaks and temperature of $100^{\circ}C$(cut off) and $130^{\circ}C$(fire). Sensors measure smoke and CO gas. In our novel system, a micom-gas meter cut off inner valve with warnings, an automatic fire extinguisher cut off middle valve and spray extinguishing materials, and sensors generate signals when detecting smoke and CO and then take a next action. Gas safety appliances and sensors automatically takes measures, and transmit those information to a wall-pad. The wall-pad again transmits real time information to server. Users can check and manage gas safety situations by connecting BcN server through web or mobile application. We hereby devised scenarios for gas safety and risk management based on the smart, and demonstrated their efficiency through test applied to filed.

Development and Performance Test of Gas Safety Management System based on the Ubiquitous Home (u-home 가스안전관리시스템 개발 및 성능시험)

  • Park, Gyou-Tae;Lyu, Geun-Jun;Kim, Young-Gyu;Kim, Yeong-Dae;Jee, Cha-Wan;Kwon, Jong-Won;Kim, Hie-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.3
    • /
    • pp.13-20
    • /
    • 2011
  • In this paper, we proposed a system to raise gas safety management by using the wireless communication module and intelligent gas safety appliances. Our designed systems configure a micom-gas meter, an automatic extinguisher, sensors, and a wallpad. A micom-gas-meter monitors gas flow, gas pressure, and earthquake. An automatic fire extinguisher checks gas(combustible) leaks and temperature of $100^{\circ}C$ and $130^{\circ}C$. Sensors measure smoke and CO gas. In our novel system, a micom-gas meter cut off inner valve with warnings, an automatic fire extinguisher cut off middle valve and spray extinguishing materials, and sensors generate signals for smoke and CO when occurring gas risk. Gas safety appliances and sensors takes safety measures, and transmit those signal to a wallpad. The wallpad again transmit signal like events to a control server. Users can connect web pages for gas safety through B-ISDN and control and manage them. We hereby devised scenarios for gas safety and risk management, and demonstrated their effectiveness through experiments.

Characteristics of CuO doped WO3 Thick Film for Gas Sensors (CuO가 첨가된 WO3 후막 가스센서 특성 연구)

  • Yu, Il;Lee, Don-Kyu;Shin, Deuck-Jin;Yu, Yoon-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.9
    • /
    • pp.1621-1625
    • /
    • 2010
  • Recently, due to increase in the usage of toxic gas and inflammability gas, the ability to monitor and precisely measurement of these gases is crucial in preventing the occurrence of various accidents. CuO doped and undoped $WO_3$ thick films gas sensors were prepared using screen-printing method on alumina substrates. A structural properties of $WO_3$:CuO thick films had monoclinic phase and triclinic phase of $WO_3$ together. Sensitivity of $WO_3$:CuO sensor at 2000 ppm of $CO_2$ gas and 50 ppm of $H_2S$ gas was investigated. 4 wt% Cu doped $WO_3$ thick films had the highest sensitivity of $CO_2$ gas and $H_2S$ gas.

Effect of a Series Connection of a Bi-Electrolyte Hydrogen Sensor in a Leak Detector

  • Han, Hyeuk Jin;Park, Chong Ook;Hong, Youngkyu;Kim, Jong Suk;Yang, Jeong Woo;Kim, Yoon Seo
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.6-9
    • /
    • 2015
  • Conventional leak detectors are widely based on helium gas sensors. However, the usage of hydrogen sensors in leak detectors has increased because of the high prices of helium leak detectors and the dearth in the supply of helium gas. In this study, a hydrogen leak detector was developed using solid-state hydrogen sensors. The hydrogen sensors are based on Park-Rapp probes with heterojunctions made by oxygen-ion conducting Yttria-stabilized zirconia and proton-conducting In-doped $CaZrO_3$. The hydrogen sensors were used for determining the potential difference between air and air balanced 5 ppm of $H_2$. Even though the Park-Rapp probe shows an excellent selectivity for hydrogen, the sensitivity of the sensor was low because of the low concentration of hydrogen, and the oxygen on the surface of the sensor. In order to increase the sensitivity of the sensor, the sensors were connected in series by Pt wires to increase the potential difference. The sensors were tested at temperatures ranging from $500-600^{\circ}C$.

Non-invasive Transcutaneous pCO2 Gas Monitoring System for Arterial Blood Gas Analysis

  • Bang, Hyang-Yi;Kang, Byoung-Ho;Eum, Nyeon-Sik;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.311-316
    • /
    • 2011
  • Monitoring the carbon dioxide concentration in arterial blood is vital for the evaluation and prevention of pulmonary disease. Yet, domestic pure arterial blood carbon dioxide sensor technologies are not being developed, instead all sensors are imported. In this paper, we develop a real time monitoring system for arterial blood partial pressure of carbon dioxide($pCO_2$) gas from the wrist by using a carbon micro-heater. The micro-heater was fabricated with a thickness of 0.3 ${\mu}m$ in order to collect the carbon dioxide under the skin. The micro-heater has been designed to perform temperature compensation in order to prevent damage to the skin. Two clinical trials of the system were undertaken. As a result, we demonstrated that a portable, transcutaneous carbon dioxide analysis($TcpCO_2$) device produced domestically is possible. In addition, this system reduced the analysis time significantly. Carbon films could reduce the unit price of these sensors by replacing the gold film used in foreign models. Also, we developed a real time monitoring system which can be used with optical biosensors for medical diagnostics as well as gas sensors for environmental monitoring.