• Title/Summary/Keyword: Gas Sensor Array System

Search Result 48, Processing Time 0.024 seconds

An explosive gas recognition system using neural networks (신경회로망을 이용한 폭발성 가스 인식 시스템)

  • Ban, Sang-Woo;Cho, Jun-Ki;Lee, Min-Ho;Lee, Dae-Sik;Jung, Ho-Yong;Huh, Jeung-Soo;lee, Duk-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.6
    • /
    • pp.461-468
    • /
    • 1999
  • In this paper, we have implemented a gas recognition system for classification and identification of explosive gases such as methane, propane, and butane using a sensor array and an artificial neural network. Such explosive gases which can be usually detected in the oil factory and LPG pipeline are very dangerous for a human being. We analyzed the characteristics of a multi-dimensional sensor signals obtained from the nine sensors using the principal component analysis(PCA) technique. Also, we implemented a gas pattern recognizer using a multi-layer neural network with error back propagation learning algorithm, which can classify and identify the sorts of gases and concentrations for each gas. The simulation and experimental results show that the proposed gas recognition system is effective to identify the explosive gases. And also, we used DSP board(TMS320C31) to implement the proposed gas recognition system using the neural network for real time processing.

  • PDF

The way to interface for electronic nose using IEEE 1451.4 (IEEE 1451.4를 이용한 전자코 시스템의 인터페이스 방안)

  • Kim, Ding-Jin;Kim, Jeong-Do;Byun, Hyung-Gi;Jung, Young-Chang;Ham, Yu-Kyung;Jung, Woo-Suk;Lee, Jung-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.123-126
    • /
    • 2005
  • The IEEE 1451.4 standards defines an architectural model for interfacing smart transducers for sensors & actuators. This standard allows analogue transducers to communicate their identification and calibration data in a digital format. A digital format is called TEDS(transducer electronic data sheet). However, the standard template of IEEE 1451.4 TEDS do not supports gas sensors to use in electronic nose system, such as array sensors. In this paper, a solution to standardize sensors for electronic nose systems is presented.

  • PDF

Adaptive TMS Variable Area Flow Meters (적응형 TMS 면적식 유량계)

  • Kwak, Doo-Sung;Kim, On;Cho, Ki-Ryang
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.3
    • /
    • pp.590-595
    • /
    • 2008
  • A new adaptive TMS variable area flow meter that is used to the environment measuring equipment is proposed. This system is consist of a ball moving within the tube line which corresponds to gas flow and photo sensor array which monitoring the movement of ball. This system can monitoring the position of bali in case of the very few gas flow in various levels. And it can automatically adjust the gas flow at the highest and the lowest level to prevent the tube line blockage.

Development of a Portable Electronic Nose System (I) - System Development - (휴대용 전자코 시스템 개발 (I) - 시스템 개발 -)

  • Lee, Jeong-Woo;Kim, Seong-Min
    • Journal of Biosystems Engineering
    • /
    • v.33 no.5
    • /
    • pp.333-339
    • /
    • 2008
  • The purpose of this study was to develop a portable electronic nose system to measure volatile components of agricultural and food products. Also, a graphical operating software to control the electronic nose system and to acquire signals through the Internet was developed. An array of five commercial metal oxide gas sensors was used to detect various volatile gas components of target samples. Transient and steady state signals were analyzed to extract variables related to sample states, To find optimal operating conditions of the system, several experiments were performed with different gas chambers, vacuum pumps, gas sampling temperatures, and sample container sizes. The patterns of gas sensor signals were analysed to find effects of the various conditions.

Design and performance evaluation of portable electronic nose systems for freshness evaluation of meats (육류 신선도 판별을 위한 휴대용 전자코 시스템 설계 및 성능 평가)

  • Kim, Jae-Gone;Cho, Byoung-Kwan
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.3
    • /
    • pp.525-532
    • /
    • 2011
  • The aim of this study was to develop a portable electronic nose system for freshness measurement of meats, which could be an alterative of subjective measurements of human nose and time-consuming measurements of conventional gas chromatograph methods. The portable electronic system was o optimized by comparing the measurement sensitivity and hardware efficiency, such as power consumption and dimension reduction throughout two stages of the prototypes. The electronic nose systems were constructed using an array of four different metal oxide semiconductor sensors. Two different configurations of sensor array with dimension were designed and compared the performance respectively. The final prototype of the system showed much improved performance on saving power consumption and dimension reduction without decrease of measurement sensitivity of pork freshness. The results show the potential of constructing a portable electronic system for the measurement of meat quality with high sensitivity and energy efficiency.

Volatile Organic Gas Recognition Using Conducting Polymer Sensor array (전도성 고분자 센서 어레이를 이용한 휘발성 유기 화합물 가스 인식)

  • Lee, Kyung-Mun;Joo, Byung-Su;Yu, Joon-Boo;Hwang, Ha-Ryong;Lee, Byung-Soo;Lee, Duk-Dong;Byun, Hyung-Gi;Huh, Jeung-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.286-293
    • /
    • 2002
  • We fabricated gas recognition system using conducting polymer sensor array for recognizing and analyzing VOCs(Volatile Organic Compounds) gases. The polypyrrole and polyaniline thin film sensors which were made by chemical polymerization were employed to detect VOCs. The multi-dimensional sensor signals obtained from the sensor array were analyzed using PCA(principal component analysis) technique and RBF(radial basis function) Network. Throughout the experimental trails, we confirmed that RBF Network is effective than PCA technique in identifying VOCs.

Implementation of a Portable Electronic Nose System for Field Screening (필드 스크린을 위한 휴대용 전자코 시스템의 구현)

  • Byun, Hyung-Gi;Lee, Jun-Sub;Kim, Jeong-Do
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.41-46
    • /
    • 2004
  • There is currently much interest in the development of instruments that emulate the senses of humans. Increasingly, there is demand for mimicking the human sense of smell, which is a sophisticated chemosensory system. An electronic nose system is applicable to a large area of industries including environmental monitoring. We have designed a protable electronic nose system using an array of commercial chemical gas sensors for recognizing and analyzing the various odours. In this paper, we have implemented a portable electronic nose system using an array of gas sensors for recognizing and analyzing VOCs (Volatile Organic Compounds) in the field. The accuracy of a portable electronic nose system may be lower than an instrument such as GC/MS (Gas Chromatography/Mass Spectrometer). However, a portable electronic nose system could be used on the field and showed fast response to pollutants in the field. Several different algorithms for odours recognition were used such as BP (Back-Propagation) or LM-BP (Levenberq-Marquardt Back-Propagation). We applied RBF (Radial Basis Function) Network for recognition and quantifying of odours, which has simpler and faster compared to the previously used algorithms such as BP and LM-BP.

Fabrication of one chip smell recognition system (원칩형 냄새 인식시스템 구현)

  • 장으뜸;정완영;서용수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.602-605
    • /
    • 2000
  • Recently, a study of intellectual smell recognition system is applied for the various fields such as control of food processing and survey of decay. A basic gas recognition system was implemented gases using four metal oxides semiconductor sensors as inputs. A CPLD chip of twenty thousand gates level was used for this purpose. The CPLD chip was designed and the availability of the one chip smell recognition system was tested.

  • PDF

Classification of Aroma Using Neural Network (신경회로망을 이용한 아로마 분류)

  • Kim, Yong Soo;Kim, Han-Soo;Kim, Sun-Tae;Lim, Mi-Hye
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.5
    • /
    • pp.431-435
    • /
    • 2013
  • Aroma has been used for healing for a long time. The healing effects depend on aroma used. We made gas sensor array system to classify aromas systematically. We used outputs of sensors as the input to IAFC neural network. Results show that the neural network successfully classified jasmine, orange, roman chamomile, and lavender into 4 classes, and classified without any error.

A portable electronic nose (E-Nose) system using PDA device (개인 휴대 단말기 (PDA)를 기반으로 한 휴대용 E-Nose의 개발)

  • Yang, Yoon-Seok;Kim, Yong-Shin;Ha, Seung-Chul;Kim, Yong-Jun;Cho, Seong-Mok;Pyo, Hyeon-Bong;Choi, Chang-Auck
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.69-77
    • /
    • 2005
  • The electronic nose (e-nose) has been used in food industry and quality controls in plastic packaging. Recently it finds its applications in medical diagnosis, specifically on detection of diabetes, pulmonary or gastrointestinal problem, or infections by examining odors in the breath or tissues with its odor characterizing ability. Moreover, the use of portable e-nose enables the on-site measurements and analysis of vapors without extra gas-sampling units. This is expected to widen the application of the e-nose in various fields including point-of-care-test or e-health. In this study, a PDA-based portable e-nose was developed using micro-machined gas sensor array and miniaturized electronic interfaces. The rich capacities of the PDA in its computing power and various interfaces are expected to provide the rapid and application specific development of the diagnostic devices, and easy connection to other facilities through information technology (IT) infra. For performance verification of the developed portable e-nose system, Six different vapors were measured using the system. Seven different carbon-black polymer composites were used for the sensor array. The results showed the reproducibility of the measured data and the distinguishable patterns between the vapor species. Additionally, the application of two typical pattern recognition algorithms verified the possibility of the automatic vapor recognition from the portable measurements. These validated the portable e-nose based on PDA developed in this study.