• 제목/요약/키워드: Gas Penetration

검색결과 330건 처리시간 0.024초

정적연소실내의 디젤분무증발과 연소특성에 관한 연구 (A Study on the Diesel Spray Evaporation and Combustion Characteristics in Constant Volume Chamber)

  • 김상호;김석준;이만복;김응서
    • 한국자동차공학회논문집
    • /
    • 제2권6호
    • /
    • pp.102-109
    • /
    • 1994
  • As a fundamental study to apply high pressure injection system to direct injection diesel engine, fuel injection system and constant volume combustion chamber were made and the behaviors of evaporating spray with the variation of injection pressure and the ambient gas temperature were observed by using high speed camera, and the combusion characteristics with the variation of injection pressure and A/F ratio were analyzed. As injection pressure increases, spray tip penetration and spray angle increase and, as a results spray volume increases. This helps an uniform mixing of fuel and air. Spray liquid core length decreases as ambient gas temperature increases, while it decreases as injection pressure increases but the effect of ambient gas temperature is dorminant. As injection pressure increases, ignition delay is shortened and combustion rate being raised, maximum heat release rate increases. It become clear that High injection pressure has high level of potential to improve the performance of DI-diesel engine.

  • PDF

Role of A-TIG process in joining of martensitic and austenitic steels for ultra-supercritical power plants -a state of the art review

  • Bhanu, Vishwa;Gupta, Ankur;Pandey, Chandan
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.2755-2770
    • /
    • 2022
  • The need for Dissimilar Welded Joint (DWJ) in the power plant components arises in order to increase the overall efficiency of the plant and to avoid premature failure in the component welds. The Activated-Tungsten Inert Gas (A-TIG) welding process, which is a variant of Tungsten Inert Gas (TIG) welding, is focus of this review work concerning the DWJ of nuclear grade creep-strength enhanced ferritic/martensitic (CSEF/M) steels and austenitic steels. A-TIG DWJs are compared with Multipass-Tungsten Inert Gas (M-TIG) DWJ based on their mechanical and microstructural properties. The limitations of multipass welding have put A-TIG welding in focus as A-TIG provides a weld with increased depth of penetration (DOP) and enhanced mechanical properties. Hence, this review article covers the A-TIG welding principle and working parameters along with detailed analysis of role played by the flux in welding procedure. Further, weld characteristics of martensitic and austenitic steel DWJ developed with the A-TIG welding process and the M-TIG welding process are compared in this study as there are differences in mechanical, microstructural, creep-related, and residual stress obtained in both TIG variants. The mechanics involved in the welding process is deliberated which is revealed by microstructural changes and behavior of base metals and WFZ.

Study on Effects of Pressure Ratio on the Wall-impingement Spray Characteristics of Nitrogen Gas using CNG Injector

  • Pham, Quangkhai;Chang, Mengzhao;Choi, Byungchul;Park, Suhan
    • 한국분무공학회지
    • /
    • 제27권1호
    • /
    • pp.1-10
    • /
    • 2022
  • In this study, an experimental investigation on the effects of the pressure ratio on the wall-impingement spray characteristics of nitrogen gas using a compressed natural gas (CNG) injector was conducted. The transient development of the impingement spray was recorded by a high speed camera with Z-type Schlieren visualization method. The spray behavior under various pressure ratio conditions were analyzed. The experimental results showed that the pressure ratio has positive effect on the development of spray wall-impingement. The effects of the above factor were evaluated in a constant volume chamber at atmospheric conditions. The data from test showed that, with the increase of the pressure ratio, the spray tip penetration (STP) quickly increases before the impingement and gradually increases after the impingement. Additionally, the spray velocity first increases and then sharply decreases on regardless of the injection pressure level. As the spray spreading angle increases, spray area and volume increases rapidly with the increase in STP at the beginning of injection, and finally entered a stable range, has a great correlation with the increase of pressure ratios.

Study of hydrodynamics and iodine removal by self-priming venturi scrubber

  • Jawaria Ahad;Talha Rizwan ;Amjad Farooq ;Khalid Waheed ;Masroor Ahmad ;Kamran Rasheed Qureshi ;Waseem Siddique ;Naseem Irfan
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.169-179
    • /
    • 2023
  • Filtered containment system is a passive safety system that controls the over-pressurization of containment in case of a design-based accidents by venting high pressure gaseous mixture, consisting of air, steam and radioactive particulate and gases like iodine, via a scrubbing system. An indigenous lab scale facility was developed for research on iodine removal by venturi scrubber by simulating the accidental scenario. A mixture of 0.2 % sodium thiosulphate and 0.5 % sodium hydroxide, was used in scrubbing column. A modified mathematical model was presented for iodine removal in venturi scrubber. Improvement in model was made by addition of important parameters like jet penetration length, bubble rise velocity and gas holdup which were not considered previously. Experiments were performed by varying hydrodynamic parameters like liquid level height and gas flow rates to see their effect on removal efficiency of iodine. Gas holdup was also measured for various liquid level heights and gas flowrates. Removal efficiency increased with increase in liquid level height and gas flowrate up to an optimum point beyond that efficiency was decreased. Experimental results of removal efficiency were compared with the predicted results, and they were found to be in good agreement. Maximum removal efficiency of 99.8% was obtained.

이중 콘형 부분예혼합 GT 연료노즐의 연소특성 및 발전플랜트 실증 (Combustion Characteristics and On-site Performance Test of a Double-cone Partial Premixed Nozzle with Various Fuel hole Patterns)

  • 김한석;조주형;김민국;황정재;이원준;민경욱;강도원
    • 한국가스학회지
    • /
    • 제25권6호
    • /
    • pp.22-28
    • /
    • 2021
  • 발전용 가스터빈에 사용되는 이중 콘형 예혼합 연소기의 성능 개선 및 검증을 위하여 기존 노즐에서 연료 분사 특성을 개선한 노즐(분사구 직경 증가, 분사구 수 감소, 총 분사면적 유지)을 이용하여 고압 및 다중화염 조건에서 실험 연구를 수행하였으며 배기가스 특성을 기존 노즐과 비교하였다. 실험 결과로는 노즐의 연료 직경을 크게 한 경우 연소용 공기로 연료의 침투 거리가 증가하기 때문에 콘 내부에서 연료와 공기의 혼합특성이 개선되어 상압뿐만 아니라 압력 상승 시 NOx 배출 농도는 감소하며 다중 화염의 경우 화염간 연소영역의 중첩이 감소하게 되어 NOx 배출은 감소하지만 화염 안정성은 저하된다. 연료 분사구를 개선한 노즐의 발전 플랜트 실증 결과는 실험 결과와 같이 기존 노즐에 비하여 NOx 농도가 낮게 배출되었다.

GTAW 펄스 용접 조건에 따른 타이타늄 정밀관의 용입, 변색 및 굽힘특성 (Effects of GTAW Pulse Condition on Penetration, Discoloration and Bending Property for Titanium Tube)

  • 민성환;안성용;박지태;박영도;강남현
    • Journal of Welding and Joining
    • /
    • 제32권6호
    • /
    • pp.47-55
    • /
    • 2014
  • The purpose of the study is to produce a mechanically improved weld and minimum variation of color through comparing unpulsed and pulsed GTAW (Gas Tungsten Arc Welding) for pure titanium (CP grade7) tube. Pulsed GTAW using 60 A peak current and 20 A background current (1:9) achieved the wider window of welding conditions having part and full penetration without burn-through than the case of unpulsed GTAW. Moreover, the pulsed welding reduced a discoloration on the back bead of the weld and the size of microstructures (basket weave and serrated ${\alpha}$). That is because the pulsed welding has it's a low heat input and severe weld flow induced from electric current variation. Furthermore, the pulsed welding improved the bending property of the welded Ti tube. The enhanced bending property for the pulsed GTAW was due to the insignificant discoloration on the weld surface with maintaining the metal polish.

응축 증발법을 통한 서브마이크론 입자의 단극하전 특성 (Characteristics of Unipolar Charging of the Submicron Particles by the Condensation-Evaporation Method)

  • 최영주;김상수
    • 대한기계학회논문집B
    • /
    • 제30권2호
    • /
    • pp.186-192
    • /
    • 2006
  • We applied a new charging system using the condensation and evaporation method to charge the submicron particles with a uniform charging performance. The monodispersed NaCl submicron particles were condensed by n-butanol vapor and grew up to micron droplets with a same size, regardless of their initial size. Those condensed droplets were charged in an indirect corona charger. The indirect corona charger consisted of the ion generation zone and the particle charging zone. In the ion generation zone, Ions were generated by corona discharge and some of them moved into the particle charging zone by a carrier gas and mixed with the condensed droplet. And finally, the charged and condensed droplets dried through an evaporator to shrink to their original size. The average charge and penetration rate of the particles before and after evaporation were measured by CPC and aerosol electrometer and compared with those of a conventional corona charger. The results showed that the average charge was $5\~7$ charges and the penetration rate was over $90\%$, regardless of the initial particle size.

고출력 $CO_2$레이저 용접에서 키홀의 불안정으로 발생한 기공의 절감방법 (Reduction Method of Porosity Formed by Instability of Keyhole in High Power $CO_2$ Laser Welding)

  • 김정일;조민현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권4호
    • /
    • pp.464-471
    • /
    • 2002
  • Porosity formation in partial penetration welds by high power lasers is a serious problem in industry. There are two main causes that induce porosity formation. One form of porosity is due to gases (e.g. hydrogen, oxygen) dissolving into the weld pool because of the high temperature and then the rapid solidification traps gases as a bubble in the weld metal. The second problem is voids formed by the keyhole collapsing due to unstable keyhole fluid dynamics. The voids that form at the bottom of the keyhole are relatively large and irregular in shape compared to the gas bubbles; this void formation is the primary concern in this paper. The reduction of voids formed by keyhole collapse is achieved by improving the stability of keyhole. Two methods to improve keyhole stability are discussed in this paper: pulse modulation and beam incident angle. Pulse modulation of the laser beam was performed between 100 Hz and 500 Hz to find out the optimum frequency for the keyhole dynamics. The incident beam angle changed the impact angle of the laser beam to the work surface in a range of 0 to 25 degrees. Glycerin in a semi-solidified state is used as a medium for performing the welding because its transparency allows of visualization of the keyhole.

중탄소강과 오스테나이트계 스테인레스강의 Nd:YAG 레이저의이종금속 용접 (Dissimilar Metal Welding of Nd:YAG Laser of Austenitic Stainless Steel and Medium Carbon Steel)

  • 신호준;유영태;안동규;임기건;신병헌
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1560-1565
    • /
    • 2005
  • Laser beam welding is increasingly being used in welding of structural steels. The laser welding process is one of the most advanced manufacturing technologies owing to its high speed and deep penetration. The thermal cycles associated with laser welding are generally much faster than those involved in conventional arc welding processes, leading to a rather small weld zone. Experiments are performed for 304 stainless steel plates changing several process parameters such as laser power, welding speed, shielding gas flow rate, presence of surface pollution, with fixed or variable gap and misalignment between the similar and dissimilar plates, etc. The following conclusions can be drawn that laser power and welding speed have a pronounced effect on size and shape of the fusion zone. Increase in welding speed resulted in an increase in weld depth/ aspect ratio and hence a decrease in the fusion zone size. The penetration depth increased with the increase in laser power.

  • PDF

EXCIPLEX법에 의한 디젤분무의 구조와 분사계 개선에 관한 연구 (A study on the structure of a diesel spray and the Improvement of the Injection System by the Exciplex Method)

  • 김덕줄;차건종
    • 대한기계학회논문집
    • /
    • 제19권9호
    • /
    • pp.2373-2385
    • /
    • 1995
  • The goals of this study are to apply exciplex method to the visualization of the fuel spray of a diesel engine and to investigate the liquid phase of fuel spray that injected at the various tips of a fuel injector. This study provides the informations for the improvement of the diesel injection system and the structures of diesel spry with the boiling of fuel droplets in combustion chamber by the exciplex method. Hexame was used as fuel for approximation to injection condition of the engine. And naphthalene and TMDP were added to the fuel for the visualization by exciplex method. Experimental injectors were 4hole, 8hole, and 1hole impinging injectors. In the injection condition of actual engine the exciplex was sufficient to catch the liquid phase signal. The spray penetration of impinging injector was small than that of actual 4 and 8hole injector but atomization was better. The upper bound of impinging injector was determined by the geometry of a cylinder head and the lower bound was determined by spray angle. On impinging injector the atomization was better at the edge of disk than at center of disk and also the mixing with environmental gas was better.