• Title/Summary/Keyword: Gas Management System

Search Result 711, Processing Time 0.032 seconds

Case study on operating characteristics of gas fueled ship under the conditions of load variation

  • Chun, Jung-Min;Kang, Ho-Keun;Kim, You-Taek;Jung, Mun-Hwa;Cho, Kwon-Hae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.5
    • /
    • pp.447-452
    • /
    • 2016
  • The use of gas as fuel, particularly liquefied natural gas (LNG), has increased in recent years owing to its lower sulfur and particulate emissions compared to fuel oil or marine diesel oil. LNG is a low temperature, volatile fuel with very low flash point. The major challenges of using LNG are related to fuel bunkering, storing, and handling during ship operation. The main components of an LNG fuel system are the bunkering equipment, fuel tanks, vaporizers/heaters, pressure build-up units (PBUs), and gas controlling units. Low-pressure dual-fuel (DF) engines are predominant in small LNG-powered vessels and have been operating in many small- and medium-sized ferries or LNG-fueled generators.(Tamura, K., 2010; Esoy, V., 2011[1][2]) Small ships sailing at coast or offshore rarely have continuous operation at constant engine load in contrast to large ships sailing in the ocean. This is because ship operators need to change the engine load frequently due to various obstacles and narrow channels. Therefore, controlling the overall system performance of a gas supply system during transient operations and decision of bunkering time under a very poor infrastructure condition is crucial. In this study, we analyzed the fuel consumption, the system stability, and the dynamic characteristics in supplying fuel gas for operating conditions with frequent engine load changes using a commercial analysis program. For the model ship, we selected the 'Econuri', Asia's first LNG-powered vessel, which is now in operation at Incheon Port of South Korea.

Development of Monitoring System Using Residual Gas Analyzer (RGA) and Artificial Intelligence Modeling (잔류가스 분석기(RGA)와 인공지능 모델링을 이용한 모니터링 시스템 개발)

  • Ji Soo Lee;Song Hun Kim;Gyeong Su Kim;Hyo Jong Song;Sang-Hoon Park;Deuk-Hoon Goh;Bong-Jae Lee
    • Journal of the Semiconductor & Display Technology
    • /
    • v.23 no.2
    • /
    • pp.129-134
    • /
    • 2024
  • This study aims to talk about the necessity of solving the PFC gas emission problem raised by the recent development of the semiconductor industry and the remote plasma source method monitoring system used in the semiconductor industry. The 'monitoring system' means that the researchers applied machine learning to the existing monitoring technology and modeled it. In the process of this study, Residual Gas Analyzer monitoring technology and linear regression model were used. Through this model, the researchers identified emissions of at least 12700mg CO2 to 75800mg CO2 with values ranging from ion current 0.6A to 1.7A, and expect that the 'monitoring system' will contribute to the effective calculation of greenhouse gas emissions in the semiconductor industry in the future.

  • PDF

A Study on Developing a Safety Management Evaluation Program (안전관리 평가 시스템 구축에 관한 연구)

  • Kim Yun-Hwa;Lim Dong-Yun;In Cha-Soon;Ko Jae-Wook;Lim Dong-Ho;Choi Soo Hyoung
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.3
    • /
    • pp.96-100
    • /
    • 1998
  • Chemical plants with high-technological equipments and complex processes are continually increasing potential hazards that may result in huge industrial accidents. If an incident breaks out, it will have a hazardous effect on in-plant workers, neighboring inhabitants or the surrounding environment. Therefore, it is necessary to develop a safety management system that can pre-evaluate the safety and reduce the risk of a chemical plants. The safety management evaluation program developed in this study can implement an effective loss control management in chemical plants. It integrates important lists in safety management lists and legal measures to analyze elements systematically. It also includes incident case analysis and the required components in domestic laws.

  • PDF

Development of Gas Turbine Data Acquisition and Monitoring System based on LabVIEW (LabVIEW 기반의 가스터빈 데이터취득 및 모니터링 시스템 개발)

  • Kang Feel-Soon;Cha Dong-Jin;Chung Jae-Hwa;Seo Seok-Bin;Ahn Dal-Hong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.270-273
    • /
    • 2006
  • This paper presents a gas turbine data acquisition and monitoring system using a LabVIEW programming. The developed real-time monitoring system entitled a C-Tune DAS plays an important role to make an analysis of the real-time operation of the gas turbine under maintenance. The LabVIEW based software is divided into three parts according to their original functions; Data acquisition, Data analysis and display, and Data storage. The data acquisition part receives data from a PMS (Plant Management System) server and two cFPs (Compact-Field Point). To verify the validity of the developed system, it is applied to gas turbines in the combined cycle power plant in Korea.

  • PDF

Evaluation for mechanical hardness of gas turbine rotor bolt according to deterioration of specimen (시편의 열화에 따른 가스터빈 로터볼트 기계적 강도평가)

  • Gil, D.S.;Ahn, Y.S.;Park, S.K.
    • Journal of Power System Engineering
    • /
    • v.15 no.4
    • /
    • pp.19-24
    • /
    • 2011
  • The operational efficiency of domestic gas turbine is about 25% and it is now in the trend of the gradual growth in spite of the severe temperature, frequent starting and shutdown according to the environmental management and the energy-efficient use. Rotor bolts of gas turbine in power plants have been the cause of defects because these gas turbines have been operated for a long time under the high pressure and temperature environment experiencing the aging change and stress concentration of the bonded part. The connection parts of the bolt revealed various failure shape and these parts were elongated under very low pressure when operated in the relaxed condition. The cause is in the lack of the metal distribution in the bottle lack area and the cap screw of the bolt is broken totally in case that the nut is fastened in most cases. Gas turbine rotor bolts are connected to the rotor wheel and these bolts caused the vibration, the bulk accident of the rotor in the event that the coupling power among these bolts was relaxed. Therefore, we would like to evaluate the soundness of the main part of the gas turbine rotor bolt through the measurement of the inner condition change along with the mechanic deterioration and temperature, stress in the gas turbine rotor material.

Construction of The Urban Disaster Management System Using the Wireless Internet GIS (무선 인터넷 GIS를 이용한 도시재해관리시스템구축)

  • 유환희;안기원;이민우
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.19 no.1
    • /
    • pp.55-66
    • /
    • 2001
  • All kinds of disasters are occurring for several reasons in modern cities. So, We need the disaster management system to deal with them at this point that Those disasters are getting larger and more frequent. We organized the database into three categories; the traffic accident database on traffic accidents that is recognized as a typical disaster resulting from vehicles's increasement rapidly in modern urban life, the gas explosion disaster database on gas explosion that causes to fatal damage through broad areas, and the bridge management database that contains bridge resource information and repair record. In this study, we developed the Disaster Management System using the wireless internet GIS that can access the database and identify field information for the accident area in emergency situation as well as can modify and update the database in field directly, so that can cope with the disaster situations effectively.

  • PDF

Thermal Management Study of PEMFC for Residential Power Generation (가정용 연료전지 시스템의 열관리 해석)

  • Yu, Sang-Seok;Lee, Young-Duk;Ahn, Kook-Young
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2839-2844
    • /
    • 2008
  • A PEMFC(proton exchange membrane fuel cell) is a good candidate for residential power generation to be cope with the shortage of fossil fuel and green house gas emission. The attractive benefit of the PEMFC is to produce electric power as well as hot water for home usage. Typically, thermal management of vehicular PEMFC is to reject the heat from the PEMFC to the ambient air. Different from that, the thermal management of PEMFC for RPG is to utilize the heat of PEMFC so that the PEMFC can be operated at its optimal efficiency. In this study, dynamic thermal management system is modeled to understand the response of the thermal management system during dynamic operation. The thermal management system of PEMFC for RPGFC is composed of two cooling circuits, one for controling the fuel cell temperature and the other for heating up the water for home usage. Dynamic responses and operating strategies of the PEMFC system are investigated during load changes.

  • PDF

Development of Methane Gas Leak Detector Using Mid-infrared Ray Sensors with $3.2\;{\mu}m$ ($3.2\;{\mu}m$ 중적외선 센서를 이용한 메탄가스누출검지기의 개발)

  • Park, Gyou-Tae;Lyu, Keun-Jun;Han, Sang-In;Oh, Jeong-Seok;Kim, Ji-Yoon;Ahn, Sang-Guk;Yoon, Myung-Seop;Kwon, Jeong-Rock
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.48-52
    • /
    • 2008
  • According to extremely industrial growth, gas facilities, equipments and chemical plants are gradually increased due to incremental demands of annual amount of gases. The safety management of gases, however, is still far from their requirements. Methane, the principal ingredient of natural gas, is inflammable and explosive and is much used in factories and houses. Therefore, these gas safety management is essential. So, we, with a program of the gas safety management, hope to develop the detection system of methane gas leak using mid-infrared ray LED and PD with $3.2\;{\mu}m$. The cryogenic cooling device is indispensible at laser but needless at LED driven on the room temperature if manufacturing optical sensor with $3.2\;{\mu}m$. It, consequently, is not only possible to implement for subminiature and portable type but also able to speedily detect methane of extremely small quantities because the $CH_4$ absorption intensity at $3.2\;{\mu}m$ is stronger than that at $1.67\;{\mu}m$. Our objective of research is to prevent gas leak accidents from occurring previously and to minimize the extent of damage from them.

  • PDF

An Empirical Study on the Repair Rate of Domestic Gas Boiler within Warranty Period(I) (가정용(家庭用) 가스 보일러의 보증기간내(保證期間內) 수리율(修理率)에 관(關)한 실증적(實證的) 연구(硏究)(I))

  • Han, Jae-Hoon;Kim, Bong-Sun
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.1
    • /
    • pp.139-146
    • /
    • 2014
  • As Crosby notes, the most companies spend 15 to 20% of their sales dollars on quality costs. Generally the most effective way to manage quality costs is to avoid having defects in the first place. In this paper we have studied about the repair(service) problem of domestic gas boiler within warranty period. We develop a system, which man could find the cause of the problem at an early stage and could devise a countermove to the problem under supposing that the service(repair) rate follows exponential distribution and the product is manufactured lot-for-lot continually. Using the developed early sensing system. it is expected to improve the reliability of the product, to save expenses of company and to improve customer's satisfaction. And the system will be expended to incorporate information technology, which can detect the repair rate automatically.

Food Service Management in Elementary School in Chunnam Province (전남 초등학교의 급식유형별 급식관리 실태)

  • 노희경;최여자
    • Korean Journal of Community Nutrition
    • /
    • v.7 no.2
    • /
    • pp.211-218
    • /
    • 2002
  • This study was undertaken to assess the school flood service management and its perception by dietitians. Questionnaries were developed and answered by 162 dietitians in elementary schools in Chollanam-do. The duration of the flood service system was the longest in remote areas followed by rural and urban areas. The average number of persons served a day was 680 per dietitians. More than three schools were supervised by 52.4% of dietitians. Lack of facilities, including restrooms for the flood service personnel and storage compartments for convenience products were indicated. Regardless of the type of school flood service system, the dietitians pointed out that they urgency needed gas fryers, gas griddles and vegetable cutters, which would be helpful in preparing fried flood for the students. Despite the dietitians' eagerness to teach nutritional education, 80.9% of the respondents did not provide nutritional education to the students, because of the lack of class roomtime. It was suggested that the teaching nutritional education by dietitians was desperately needed for the improvement of health and the nutritional status of school children.