• Title/Summary/Keyword: Gas Detection

Search Result 1,206, Processing Time 0.035 seconds

Microbe and Quality Changes of Ready-to-Eat Lettuce during Storage at Different Temperatures (신선편이 양상추의 온도별 저장 중 미생물과 품질변화)

  • Cho, Sun-Kyung;Kwon, Hye-Soon;Park, Jong-Hyun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.12
    • /
    • pp.1867-1872
    • /
    • 2010
  • Microbe and quality changes of vacuum-packaged ready-to-eat lettuce were analyzed. While the vacuumpackaged lettuce after chlorine sanitizer were stored at $5^{\circ}C$, $15^{\circ}C$, and $25^{\circ}C$ for 7 days, viable numbers of total aerobic bacteria (TAB), coliform, E. coli, food-borne pathogens and lactic acids bacteria (LAB) were counted with gas production and sensory evaluation. Before the storage, only TAB of 2 log CFU/g and coliform of 1 log CFU/g were detected and LAB was not detected. TAB, coliform and LAB increased by 1 log CFU/g at $5^{\circ}C$ for 7 days without any detection of the pathogens. Sensory evaluations for off-flavour and crispness dropped to half the best value at 5 day storage. TAB and coliform increased by 3 log CFU/g and 2 log CFU/g, respectively, but LAB grew very actively by 4 log CFU/g under anaerobic environment and only B. cereus were detected after enrichment of the lettuce at $15^{\circ}C$ for 3 days. The evaluations for off-flavour and crispness were half the best value for 3 days. However, TAB and coliform increased by 3 log CFU/g, 1 log CFU/g, and 4 log CFU/g, respectively only at 1 day storage under $25^{\circ}C$. Also B. cereus were detected after enrichment and the sensory evaluation were half the best value within 1 day storage. Therefore, preservation at the lowest temperature possible is required for growth inhibition of the bacteria contaminated in the lettuce. Interestingly, LAB among them grew most actively under the anaerobic condition and the adulteration of lettuce might be closely related with the growth of LAB.

Effect of Influent C/N Ratio and DO on Denitrification of Nitrate Polluted Groundwater in a Biofilter Process (Biofilter 공정에서 유입 C/N비와 DO가 지하수의 질산성 질소제거에 미치는 영향)

  • Lee, Moo-Jae;Park, Sang-Min;Park, Noh-Back;Jun, Hang-Bae;Kim, Kong-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.4
    • /
    • pp.355-361
    • /
    • 2006
  • In this study, effects of influent C/N(COD/Nitrate) ratio and dissolved oxygen(DO) concentration on biological nitrate removal from groundwater were investigated in the fixed-type biofilter. Influent nitrate of 30 mg/L was removed completely by biological denitrification at the C/N ratio of 10 and 4.0, while residual nitrate of 5 mg/L occurred at the C/N ratio of 2.0, which resulted from deficiency of organic electron donor. Furthermore, nitrite was accumulated up to about 5 mg/L as the C/N ratio decreased to 2.0. Increase in DO concentration also inhibited denitrification activity at the relatively high C/N ratio of 5.0, which decreased the nitrate removal efficiency. Although the influent DO concentration was reduced as low as 0.3 mg/L using sodium sulfite($Na_2SO_3$), effluent nitrite was up to 3.6 mg/L. On the other hand, nitrate was completely removed without detection of nitrite at the DO concentration of 0.3 mg/L using nitrogen gas($N_2$) sparging. The organic matter for denitrification in biofilter were in the range from 3.0 to $3.5gSCOD/g{NO_3}^--N$, while utilized these values increased at the high DO concentration of 5.5 mg/L. In addition to the high DO concentration and the low influent C/N ratio, DO control by chemical such as sodium sulfite affected on biological denitrification, which resulted in the reduction of nitrate removal efficiency and nitrite build-up in a biofilter.

Contents of Total Mercury and Methylmercury in Deep-sea Fish, Tuna, Billfish and Fishery Products (심해성 어류, 다랑어류, 새치류 및 어류가공품의 총수은 및 메틸수은 함량)

  • Kang, Suk-Ho;Lee, Myung-Jin;Kim, Jae Kwan;Jung, You-Jung;Hur, Eun-Seon;Cho, Yoon-Sik;Moh, Ara;Park, Kwang-Hee
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.1
    • /
    • pp.42-49
    • /
    • 2017
  • The aim of this study was to determine total mercury and methyl mercury level in fishes (Deep-sea Fish, Tuna, Billfish) and fishery products. A total of 101 fishes and 44 fishery products samples collected from commercial market in Gyeonggi-do. Total mercury were analysed by mercury analyzer and methyl mercury were analyzed by gas chromatography with electron capture detector. In the fishes, total mercury was detected in all samples and methylmercury was detected in 92 samples of them. The detection rate of methylmercury was 91.1% in fishes. The mean concentration (mg/kg) of total mercury and methylmercury were $1.968{\pm}0.505/0.496{\pm}0.057$ for Billfish, $0.665{\pm}0.091/0.252{\pm}0.033$ for Deep-sea Fish and $0.577{\pm}0.085/0.218{\pm}0.025$ for Tuna, respectively. The Swordfish contains the highest level of total mercury (1.968 mg/kg) and methylmercury (0.496 mg/kg). In Mabled rockfish, the ratio of methylmercury's contents about total mercury's contents was the highest as 66.5%. In case of fishery products, frozens made of 100% of raw material contained the highest level of total mercury and methyl mercury. The weekly intake of total mercury and methylmercury was calculated in 4.72% and 5.24% of Provisional Tolerable Weekly Intake (PTWI) respectively. This study showed that the weekly intake of methylmercury from Deep-sea Fish, Tuna and Billfish was less than the PTWI recommended by the Joint FAO/WHO expert committee on food additives.

Determination of homogentisic acid in human plasma by GC-MS for diagnosis of alkaptonuria (GC-MS를 이용한 혈장 중 호모겐티식산의 분석;알캅톤뇨증의 진단)

  • Thapa, Maheshwor;Yu, Jundong;Lee, Wonjae;Islam, Fokhrul;Yoon, Hye-Ran
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.323-330
    • /
    • 2015
  • Alkaptonuria, a rare inherited metabolic disease, is characterized by a lack of homogentisate dioxygenase and accumulation of homogentisic acid (HGA), leading to homogentisic aciduria, arthritis, and ochronosis. In this study, a rapid analytical method, without an expensive and tedious solid phase extraction step, was developed to quantify HGA in plasma using GC-MS. HGA-spiked pooled plasma samples were subjected to liquid-liquid extraction (LLE) with ethyl acetate, followed by trimethylsilyl derivatization (TMS) and GC-MS quantification using selected ion monitoring. The formation of TMS derivative of the 1 carboxylic and 2 hydroxyl functional groups was performed by reacting BSTFA (with 10% TMCS) for 5 min at 80 ℃. For selected ion monitoring, quantification and confirmation ions were determined based on specific ions (m/z 384, m/z 341 and m/z 252) of the TMS derivative of HGA. Calibration curves of pooled normal plasma specimens showed a linear relationship in the range of 1-100 ng/µL. The precision and accuracy were within a relative standard deviation (RSD) of 1 to 15% and a bias of -5 to 25%. Recoveries were obtained in the range of 99-125% and 95-115% for intra-day and inter-day assay, respectively, at 2, 20 and 80 ng/µL. The limit of detection (LOD) and limit of quantification (LOQ) were 0.4 ng/µL and 4 ng/µL, respectively. No homogentisic acid was excreted from normal Korean plasma samples. Collectively, the results from the present study suggest that this method could be useful for routine diagnosis and therapeutic monitoring of alkaptonuria patients with excellent sensitivity and rapidity.

Selective determination of mercury (II) ion in aqueous solution by chemiluminescence method (화학발광법에 의한 수용액 중의 선택적 수은(II) 이온 정량)

  • Kim, Kyung-Min;Jang, Taek-Gyun;Kim, Young-Ho;Oh, Sang-Huyb;Lee, Sang-Hak
    • Analytical Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.243-248
    • /
    • 2011
  • A selective determination method of mercury (II) ion in aqueous solution by luminol-based chemiluminescence system (luminol CL system) has been developed. Determination of metal ions such as copper (II), iron (III), chromium (III) ion in solution by the luminol CL system using its catalytic role in the reaction of luminol and hydrogen peroxide has been reported by several groups. In this study, the catalytic activity of mercury (II) ion in the reaction of luminol and hydrogen peroxide was observed by the enhanced CL intensity of the luminol CL system. Based on this phenomenon, experimental conditions of the luminol CL system were investigated and optimized to determine mercury (II) ion in aqueous solution. While mercury (II) ion in mixed sample solution containing mercury (I) and (II) ions highly enhanced the CL intensity of the luminol CL system, the mercury (I) ion could not enhanced the CL intensity. Thus selective determination of the mercury (II) ions in a mixture containing mercury (I) and (II) ions could be achieved. Each concentration of mercury (I) and (II) ions in aqueous solution can be obtained from the results of the CL method that give the concentration of only mercury (II) ion and the inductively coupled plasma (ICP) method that give the total concentration of mercury ions. On the optimized conditions, the calibration curve of mercury (II) ion was linear over the range from $1.25{\times}10^{-5}$ to $2.50{\times}10^{-3}M$ with correlation coefficient of 0.991. The detection limit of mercury (II) ion in aqueous solution was calculated to be $1.25{\times}10^{-7}M$.

Relationships between Fatty Acids and Tocopherols of Conventional and Genetically Modified Peanut Cultivars Grown in the United States (미국산 전통품종과 유전자 재조합 땅콩품종의 지방산과 토코페롤의 상관관계)

  • Shin, Eui-Cheol
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.10
    • /
    • pp.1618-1628
    • /
    • 2013
  • Relationships between fatty acids and tocopherols in conventional and genetically modified peanut cultivars were studied by gas chromatography with flame ion detector and high performance liquid chromatography with fluorescence detection. Eight fatty acids and four tocopherol isomers in the sample set were identified and quantified. Oleic acid and linoleic acid are major fatty acids and the ratio of oleic and linoleic acids ranged from 1.11 to 16.26. Tocopherols contents were 6.76 to 12.24 for ${\alpha}$-tocopherol (T), 0.08 to 0.39 for ${\beta}$-T, 5.28 to 15.02 for ${\gamma}$-T, and 0.17 to 1.17 mg/100 g for ${\delta}$-T. Correlation coefficient (r) for fatty acids and tocopherols indicated a strong inverse relationship between oleic & linoleic acids (r=-0.97, P<0.05) and positive relationships between palmitic & linoleic acids (r=0.95, P<0.05) and ${\gamma}$-T & ${\delta}$-T (r=0.83, P<0.05). Principal component analysis (PCA) of fatty acids and tocopherols gave four significant principal components (PCs, with eigenvalues>1), which together account for 85.49% of the total variance in the data set with PC1 and PC2 contributing 45.27% and 21.33% of the total variability, respectively. Eigen analysis of the correlation matrix loadings of the four significant PCs revealed that PC1 was mainly contributed by palmitic, oleic, linoleic, and gondoic acids, while PC2 was by behenic acid, ${\beta}$-T, and ${\gamma}$-T. The score plot generated by PC1-PC2 identified sample clusters in the two spatial planes based on the oleic and linoleic acids. The score plot PC3-PC4 didn't separate sample groups.

The Study about Role and Importance of Site Activity Stage in Safety Activity for the International Conference among Several Countries (다자간 국제회의 안전활동에 있어서 현장활동단계의 역할 및 중요성에 관한 연구 : 부산 APEC 행사를 중심으로)

  • Lee, Sun-Ki
    • Korean Security Journal
    • /
    • no.19
    • /
    • pp.105-138
    • /
    • 2009
  • This study's purpose is to present the improvement of effectiveness of security activity for international conference among Several Countries which can be held hereafter. On the basis of security activity problems originating in APEC that had been held in Busan in 2005. I made up questions three times to on the members of the police, military, fire figher and national intelligence service who had experienced in Busan APEC and recognition of possible problem and possibility of improvement on each item of questions was analyzed by Delphi Method. Also interviews with 4 security experts selected from each security agency were conducted to present improvement in each part of problem. The results obtained from the face to face interview with four experts of security-enforcement agency about the role and importance of site activity stage for international conference among several countries are as followings ; First, the system that experienced security-enforcement agents can be selected for the next national security event is needed, by data-basing the security-enforcement agents who were experienced in security event as man power management. Second, the middle-term plan for the introduction of high-tech equipment and joint inspection with relevant security agents are needed for the efficient explosive technical detection. Third, high-tech security equipment could be introduced through the international high-tech security equipment exhibition. Fourth, an anti-terrorism plan should be measured by sharing information through the cooperation with domestic and international intelligence agency. Fifth, public relations should be measured systematically by organization rather than agents' individual public relations. Sixth, political consideration to secure integrative coordination with other agency is needed for security activity, through normal cooperation with fire fighting related agency such as an electric, gas, elevator company. Seventh, a definite press guideline is needed for a convenient news coverage and safety during security event.

  • PDF

Change of Volume of Isoflow in Pneumoconiosis Patients with Small Opacity (소음영 진폐증 환자에서의 등기류용량(Volume of Isoflow)의 변화)

  • Oh, Sang-Yong;Kim, Jee-Won;Jung, Chang-Young;Kim, Kyung-Ah;Yun, Im-Goung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.5
    • /
    • pp.540-547
    • /
    • 1993
  • Backgrounds: The measurement of volume of isoflow has been considered as a sensitive test for detecting small airway diseases showing normal pulmonary function in a routine pulmonary function test. To evaluate the functions of small airway among dust exposed workers, the changes of volume of isoflow were measured and its applicability of managing early stage pneumoconiosis patients was studied. Method: The subjects were 67 male, pneumoconiosis with small opacity and FEV1>80%, FEV1/FVC>75% in spirometry and the controls were 20 male, no dust-exposed office workers. The maximal epiratory volume curves after inhalation of indoor air and $He-O_2$ gas mixtures were measured and ${\Delta}V_{max50},\;{\Delta}V_{max75},\;V_{iso}V/VC$ between the dust exposed and control workers were compaired. Results: 1) There were no significant differences between two group in ${\Delta}V_{max50}$ and ${\Delta}V_{max75}$. But the ratio of $V_{iso}V/VC$ of the subjects was siginificantly higher than that of the control (p<0.01). This study confirms that $V_{iso}V/VC$ is a very useful index in early detection of small airway dysfunction. 2) The ratio of $V_{iso}V/VC$ of the subjects was signigicantly different between only smoker group and mixed group(smoker and nonsmoker). It suggestes that smoking is an important cousative factor of small airway dysfunction. 3) As the profusion of the chest X-ray increased, the rartio of $V_{iso}V/VC$ increased, but no significant difference of $V_{iso}V/VC$ was found between categories of pneumoconiosis. The categories of pneumoconiosis and small airway dysfunction may not be related. 4) No significant relationship was established between the duration of work and the ratio of $V_{iso}V/VC$. Conclusions : It is concluded that the measurement of $V_{iso}V/VC$ is useful to detect small airway dysfuction of early stage pnuemoconiosis patents with small opacities but showing normal pulmonary function in a routine pulmonary function test.

  • PDF

Monitoring Methylmercury in Abyssal Fish (심해성 어류 중 메틸수은 모니터링)

  • Kim, Seong-Cheol;Jang, Jin-Wook;Kim, Hyun-Ah;Lee, Sang-Ho;Jung, Young-Ji;Kim, Ji-Yeon;Ahn, Jong-Hoon;Park, Eun-Hye;Ko, Yong-Seok;Kim, Dong-Sul;Kim, Sang-Yub;Jang, Young-Mi;Kang, Chan-Soon
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.383-389
    • /
    • 2010
  • The aim of this study was to determine the methylmercury (MeHg) levels in abyssal fish species. The MeHg in the fishes was extracted with hydrochloric acid and toluene and then purified using an L-cysteine solution. The extract was analyzed with a gas chromatography-electron capture detector (GC-${\mu}ECD$) with a thermon Hg-capillary column. The detection limit and the recovery of the method were 0.002 and 84.2-98.5% (mean, 93.4%), respectively. The MeHg content in 492 abyssal fishes ranged from 0.037 to 2.009 mg/kg. The levels of MeHg [range, mg/kg (mean)] were significantly dependent on fish species and presented as the following; 0.157-2.009 (0.546) in Scalloped hammerhead shark, 0.211-0.878 (0.501) in Blue shark, 0.121-0.993 (0.482) in Spiny dogfish, 0.243-0.658 (0.397) in Salmon shark, 0.074-1.958 (0.353) in Blacktip shark, 0.038-0.807 (0.302) in Southern hake, 0.099-0.511 (0.300) in Scorpion fish, and 0.037-0.133 (0.067) in Ling. The monitoring results showed that the estimated weekly intake of MeHg from sharks, Southern hake, and Ling were lower than the provisional tolerable weekly intake recommended by the Joint FAO/WHO expert committee on food additives.

A Study on Migration of Ethylenediamine and Hexamethylenediamine from Polyamide Utensils (Polyamide 조리기구로부터 Ethylenediamine 및 Hexamethylenediamine의 이행에 관한 연구)

  • Eom, Mi-Ok;Kwak, In-Shin;Yoon, Hae-Jung;Jeon, Dae-Hoon;Choi, Hyun-Chul;Kim, Hyung-Il;Sung, Jun-Hyun;Park, Na-Young;Kim, So-Hee;Lee, Young-Ja
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.1
    • /
    • pp.36-42
    • /
    • 2010
  • The method for the determination of ethylenediamine (EDA) and hexamethylenediamine (HMDA) in food simulants was developed, and migration amounts of these compounds was monitored for 124 polyamide (PA) utensils. The diurethane derivatives of EDA and HMDA, which produced by reaction with ethyl chloroformate, were analyzed by using gas chromatograph (GC)/flame ionization detector (FID) and GC/mass spectrometer (MS). The developed method was validated with $0.3\;{\mu}g/mL$ of limit of detection (LOD) for EDA and $0.1\;{\mu}g/mL$ of LOD for HMDA, > 0.999 of linearity($r^2$) and > 88% of recovery. The EDA was detected 1.31 and $02.06\;{\mu}g/mL$ for 2 samples in water. The HMDA was detected $0.29\;-\;0.93\;{\mu}g/mL$ for 3 samples in 20% ethanol and $0.26\;-\;0.44\;{\mu}g/mL$ for 10 samples in n-heptane. These migration levels were below the specific migration limits (SML) of $12\;{\mu}g/mL$ and $2.4\;{\mu}g/mL$ for EDA and HMDA established in EU.