• Title/Summary/Keyword: Gas Detection

Search Result 1,206, Processing Time 0.029 seconds

Correlation between High-Resolution CT and Pulmonary Function Tests in Patients with Emphysema (폐기종환자에서 고해상도 CT와 폐기능검사와의 상관관계)

  • Ahn, Joong-Hyun;Park, Jeong-Mee;Ko, Seung-Hyeon;Yoon, Jong-Goo;Kwon, Soon-Seug;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Moon, Hwa-Sik;Park, Sung-Hak;Song, Jeong-Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.3
    • /
    • pp.367-376
    • /
    • 1996
  • Background : The diagnosis of emphysema during life is based on a combination of clinical, functional, and radiographic findings, but this combination is relatively insensitive and nonspecific. The development of rapid, high-resolution third and fourth generation CT scanners has enabled us to resolve pulmonary parenchymal abnormalities with great precision. We compared the chest HRCT findings to the pulmonary function test and arterial blood gas analysis in pulmonary emphysema patients to test the ability of HRCT to quantify the degree of pulmonary emphysema. Methods : From october 1994 to october 1995, the study group consisted of 20 subjects in whom HRCT of the thorax and pulmonary function studies had been obtained at St. Mary's hospital. The analysis was from scans at preselected anatomic levels and incorporated both lungs. On each HRCT slice the lung parenchyma was assessed for two aspects of emphysema: severity and extent. The five levels were graded and scored separately for the left and right lung giving a total of 10 lung fields. A combination of severity and extent gave the degree of emphysema. We compared the HRCT quantitation of emphysema, pulmonary function tests, ABGA, CBC, and patients characteristics(age, sex, height, weight, smoking amounts etc.) in 20 patients. Results : 1) There was a significant inverse correlation between HRCT scores for emphysema and percentage predicted values of DLco(r = -0.68, p < 0.05), DLco/VA(r = -0.49, p < 0.05), FEV1(r = -0.53, p < 0.05), and FVC(r = -0.47, p < 0.05). 2) There was a significant correlation between the HRCT scores and percentage predicted values of TLC(r = 0.50, p < 0.05), RV(r = 0.64, p < 0.05). 3) There was a significant inverse correlation between the HRCT scores and PaO2(r = -0.48, p < 0.05) and significant correlation with D(A-a)O2(r = -0.48, p < 0.05) but no significant correlation between the HRCT scores and PaCO2. 4) There was no significant correlation between the HRCT scores and age, sex, height, weight, smoking amounts in patients, hemoglobin, hematocrit, and wbc counts. Conclusion : High-Resolution CT provides a useful method for early detection and quantitating emphysema in life and correlates significantly with pulmonary function tests and arterial blood gas analysis.

  • PDF

Evaluation of 226Ra analysis methods using a gamma-ray spectrometer and a liquid scintillation counter (감마선분광분석기와 액체섬광계수기를 이용한 226Ra 분석법 비교 연구)

  • Ju, Byoung Kyu;Kim, Moon Su;Kim, Hyun Koo;Kim, Dong Su;Cho, Sung Jin;Yang, Jae Ha;Park, Sun Hwa;Kim, Hyoung Seop;Kwon, Oh Sang;Kim, Tae Seung
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.228-235
    • /
    • 2015
  • The efficiency and applicability of the solid phase extraction disk method in a 226Ra analysis were examined by the gamma ray spectrometer (GRS) method using a Marinelli beaker and the liquid scintillation counter (LSC) method for groundwater. The recovered 226Ra, which was filtered by the solid phase extraction disk, was analyzed using gamma ray spectrometer The disks, which were pretreated for caulking the daughter nuclide, were sealed with polyethylene film. Distilled water was used for the blank value of the 226Ra activity. The recovery values of 214Bi and 214Pb in the solid phase extraction disk, which used 226Ra standard material, were 80% (295.21 Kev) and 104% (351.92 Kev), respectively, which were higher than 75% determined by the LSC. The injection of nitrogen gas into the measuring chamber reduced the interference values by about 10%. The detection limits of the 226Ra activity in a blank sample of 5 L were 0.17~0.40 pCi/L after 80,000 seconds of measuring time. The relationship of the 226Ra activity in the solid phase extraction disk method and in the LSC method in seven groundwater samples showed a correlation coefficient value 0.987, which implies the applicability of the solid phase extraction disk method. The results showed that 226Ra activity in groundwater using the solid phase extraction disk method has the following benefits: simple pretreatment, time saving, high recovery values, a low detection limit, and so on. Compared with the LSC method and the GRS method using the Marinelli beaker for the 226Ra analysis, the solid phase extraction disk method could be useful in groundwater samples with low levels of activities of radionuclides because the method is not restricted by the volume of the sample.

Effect of substrate bias voltage on a-C:H film (기판 bias 전압이 a-C:H 박막의 특성에 미치는 영향)

  • 유영조;김효근;장홍규;오재석;김근식
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.4
    • /
    • pp.348-353
    • /
    • 1997
  • Hydrogenated amorphous carbon(a-C:H) films were deposited on p-type Si(100) by DC saddle-field plasma enhanced CVD to investigate the effect of substrate bias on optical properties and structural changes. They were deposited using pure methane gas at a wide range of substrate bias at room temperature and 90 mtorr. The substrate bias voltage ($V_s$) was employed from $V_s=0 V$ to $V_s=400 V$. The information of optical properties was investigated by photoluminescence and transmitance. Chemical bondings of a-C:H have been explored from FT-IR and Raman spectroscopy. The thickness and relative hydrogen content of the films were measured by Rutherford backscattering spectroscopy (RBS) and elastic recoil detection (ERD) technigue. The growth rate of a-C:H film was decreased with the increase of $V_s$, but the hydrogen content of the film was increased with the increase of $V_s$. The a-C:H films deposited at the lowest $V_s$ contain the smallest amount of hydrogen with most of C-H bonds in the of $CH_2$ configuration, whereas the films produced at higher $V_s$ reveal dominant the $CH_3$ bonding structure. The emission of white photoluminescence from the films were observed even with naked eyes at room temperature and the PL intensity of the film has the maximum value at $V_s$=200 V. With $V_s$ lower than 200 V, the PL intensity of the film increased with V, but for V, higher than 200 V, the PL intensity decreased with the increase of $V_s$. The peak energy of the PL spectra slightly shifted to the higher energy with the increase of $V_s$. The optical bandgap of the film, determined by optical transmittance, was increased from 1.5 eV at $V_s$=0V to 2.3 eV at $V_s$=400 V. But there were no obvious relations between the PL peak and the optical gap which were measured by Tauc process.

  • PDF

Development of a Simultaneous Analysis Method for DDT (DDD & DDE) in Ginseng (인삼 중 DDT(DDD 및 DDE) 분석법의 개발)

  • Kim, Sung-Dan;Cho, Tae-Hee;Han, Eun-Jung;Park, Seoung-Gyu;Han, Chang-Ho;Jo, Han-Bin;Choi, Byung-Hyun
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.123-128
    • /
    • 2008
  • The MRLs (maximum residue limits) of DDT (DDD and DDE) in fresh ginseng, dried ginseng, and steamed red ginseng are set as low as 0.01 mg/kg, 0.05 mg/kg, and 0.05 mg/kg, respectively. Therefore, this study was undertaken to develop a simple and highly sensitive analysis method, as well as to reduce interfering ginseng matrix peaks, for the determination of DDT isomers (o,p'-DDE, p,p'-DDE, o,p'-DDD, p,p'-DDD, o,p'-DDT, and p,p'-DDT) in fresh ginseng, dried ginseng, and steamed red ginseng at the 0.01 mg/kg level. The method used acetonitrile extraction according to simultaneous analysis, followed by normal-phase Florisil solid-phase extraction column clean-up. The purification method entailed the following steps: (1) dissolve the concentrated sample extract in 7 mL hexane; (2) add 3 mL of $H_2SO_4$; (3) vigorously shake on avortex mixer; (4) cetrifuge at 2000 rpm for 5 min; (5) transfer 3.5 mL of the supernatant to the Florisil-SPE (500 mg/6 mL);and (6) elute the SPE column with 1.5 mL of hexane and 10 mL of ether/hexane (6:94). The determination of DDT isomers was carried out by a gas chromatography-electron capture detector (GC-${\mu}$ECD). The hexane and ether/hexane (6:94) eluate significantly removed chromatographic interferences, and the addition of 30% $H_2SO_4$ to the acetonitrile extract effectively reduced many interfering ginseng matrix peaks, to allow for the determination of the DDT isomers at the 0.01 mg/kg level. The recoveries of the 6 fortified (most at 0.01 mg/kg) DDT isomers from fresh ginseng, dried ginseng, and steamed red ginseng ranged from 87.9 to 99.6%. The MDLs (method detection limits) ranged from 0.003 to 0.009 mg/kg. Finally, the application of this method for the determination of DDT isomers is sensitive, rapid, simple, and inexpensive.

Monitoring of Residual Pesticides and Exposure Assessment of Olive Oil Products Sold on the Market (올리브유의 잔류농약 모니터링 및 노출량 조사)

  • Mi-Hui Son;Jae-Kwan Kim;You-Jin Lee;Ji-Eun Kim;Eun-Jin Baek;Byeong-Tae Kim;Seong-Nam Lee;Myoung-Ki Park;Yong-Bae Park
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.4
    • /
    • pp.211-216
    • /
    • 2023
  • A total of 100 commercially available olive oil products were analyzed for 179 pesticide residues using gas chromatography-tandem mass spectrometry (GC/MS/MS). The olive oil samples were mixed with organic solvents, centrifuged and frozen to remove fat, and pesticide residues were analyzed using the "quick, easy, cheap, effective, rugged, and safe" (QuEChERS) method. The determination coefficient (R2) of the analysis method used in this study was ≥0.998. The detection limit of the method ranged 0.004-0.006 mg/kg and its quantitative limit ranged 0.012-0.017 mg/kg. The recovery rate (n=5) measured at the level ranging 0.01-0.02, 0.1, and 0.5 mg/kg ranged 66.8-119.5%. The relative standard deviation (RSD) was determined to be ≤5.7%, confirming that this method was suitable for the "Guidelines for Standard Procedures for Preparing Food Test Methods". The results showed that a total of 151 pesticides (including difenoconazole, deltamethrin, oxyfluorfen, kresoxim-methyl, phosmet, pyrimethanil, tebuconazole, and trifloxystrobin) were detected in 64 of the 100 olive oil products. The detection range of these pesticide residues was 0.01-0.30 mg/kg. The percentage acceptable daily intake (%ADI) of the pesticides calculated using ADI and estimated daily intake (EDI) was 0.0001-0.1346, indicating that the detected pesticides were present at safe levels. This study provides basic data for securing the safety of olive oil products by monitoring pesticide residues in commercially available oilve oil products. Collectively, the analysis method used in this study can be used as a method to analyze residual pesticides in edible oils.

Evaluation of Applicability of Sea Ice Monitoring Using Random Forest Model Based on GOCI-II Images: A Study of Liaodong Bay 2021-2022 (GOCI-II 영상 기반 Random Forest 모델을 이용한 해빙 모니터링 적용 가능성 평가: 2021-2022년 랴오둥만을 대상으로)

  • Jinyeong Kim;Soyeong Jang;Jaeyeop Kwon;Tae-Ho Kim
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_2
    • /
    • pp.1651-1669
    • /
    • 2023
  • Sea ice currently covers approximately 7% of the world's ocean area, primarily concentrated in polar and high-altitude regions, subject to seasonal and annual variations. It is very important to analyze the area and type classification of sea ice through time series monitoring because sea ice is formed in various types on a large spatial scale, and oil and gas exploration and other marine activities are rapidly increasing. Currently, research on the type and area of sea ice is being conducted based on high-resolution satellite images and field measurement data, but there is a limit to sea ice monitoring by acquiring field measurement data. High-resolution optical satellite images can visually detect and identify types of sea ice in a wide range and can compensate for gaps in sea ice monitoring using Geostationary Ocean Color Imager-II (GOCI-II), an ocean satellite with short time resolution. This study tried to find out the possibility of utilizing sea ice monitoring by training a rule-based machine learning model based on learning data produced using high-resolution optical satellite images and performing detection on GOCI-II images. Learning materials were extracted from Liaodong Bay in the Bohai Sea from 2021 to 2022, and a Random Forest (RF) model using GOCI-II was constructed to compare qualitative and quantitative with sea ice areas obtained from existing normalized difference snow index (NDSI) based and high-resolution satellite images. Unlike NDSI index-based results, which underestimated the sea ice area, this study detected relatively detailed sea ice areas and confirmed that sea ice can be classified by type, enabling sea ice monitoring. If the accuracy of the detection model is improved through the construction of continuous learning materials and influencing factors on sea ice formation in the future, it is expected that it can be used in the field of sea ice monitoring in high-altitude ocean areas.

Prevalence of Enteyobius vermiculuris infection and preventive effects of masts treatment among children in rural and urban areas, and children in orphanages (농촌, 도시 및 집단생활 아동의 요충 감염과 집단 구충에 의한 예방 효과)

  • Kim, Jong-Su;Lee, Hae-Yong;An, Yeong-Gyeom
    • Parasites, Hosts and Diseases
    • /
    • v.29 no.3
    • /
    • pp.235-244
    • /
    • 1991
  • An epidemiological study and mass treatments of Enterobius vermicularis infection among children near Wonju area of Kangwon province were carried out. The children were divided into 4 groups according to their residing localities; children in the mountainous area, rural area, urban area and in orphanage. They were examined by adhesive cellotape anal swab technique, and egg positive rates were obtained. The rates of egg reduction and re-infection rates after repeated mass treatments were also observed. The results obtained were as follows: 1. The overall egg Positive rate of E. vermicularis in the first screening was 19.9% (251 out of 1, 262 examinees; 19.7% in males and 20.1% in females). The positive rates were 13.0% in the mountainous area, 11 9% in the rural area, 15.1% in the urban (medium-sized) area and 61.9% in orphanages. 2. The highest positive rates were observed in the kindergarten children, and 1st and 2nd grade children of primary schools (26.2~32.2%), and the lowest rate (13.6%) in 6-year grade children of primary schools. 3. Cumulative detection rates from 3 repeated anal swabs at 4~5 days interval were higher (70.8%) than those from single anal swabs (50.0~59.2%). 4. Out of the examinees who showed the highest cumulative positive rate (70.8%), about 39.2% were consecutively positive in 3 anal swabs. Among different groups of children, the higher the total egg detection rates (87.5%), the higher the consecutive positive rates (71.9%) . 5. A total of 2, 609 (male : female=1 : 12.4) worms were collected from 17 egg-positive cases treated with anthelinintics. The mean number of worms per child was 153 (range: 4-824) . 6. The egg-positive cases in several studied groups (180 children) were treated with anthelmintics 6 times at 3-week intervals. In this case, the overall positive rate was decreased from 54.8% to 2.2% at 15 weeks after the treatments, but no complete negative conversion was experienced. However, in a group of children (154 children) including egg Positive and negative cases who were both treated with anthelmintics at 3-week interval, a complete egg-negative conversion was observed in the 9th week after treatments. 7. The egg-detection rate in the brothers or sisters of egg Positive children was 70.0% (28 out of 40 examined), and the egg-positive rate according to the family unit was 69.7%. In summarizing the above results, it is concluded that Enterobius vermicularis infection is still highly prevalent among children in Korea, and that repeated mass treatments of more than 3 times will be effective for control of this infection.

  • PDF

The Monitoring on Plasticizers and Heavy Metals in Teabags (침출용 티백 포장재의 안전성에 관한 연구)

  • Eom, Mi-Ok;Kwak, In-Shin;Kang, Kil-Jin;Jeon, Dae-Hoon;Kim, Hyung-Il;Sung, Jun-Hyun;Choi, Hee-Jung;Lee, Young-Ja
    • Journal of Food Hygiene and Safety
    • /
    • v.21 no.4
    • /
    • pp.231-237
    • /
    • 2006
  • Nowadays the teabag is worldwide used for various products including green tea, tea, coffee, etc. since it is convenient for use. In case of outer packaging printed, however, there is a possibility that the plasticizers which is used for improvement in adhesiveness of printing ink may shift to inner tea bag. In this study, in order to monitor residual levels of plasticizers in teabags, we have established the simultaneous analysis method of 9 phthalates and 7 adipates plasticizers using gas chromatography (GC). These compounds were also confirmed using gas chromatography-mass spectrometry (GC-MSD). The recoveries of plasticizers analyzed by GC ranged from 82.7% to 104.6% with coefficient of variation of $0.6\sim2.7%$ and the correlation coefficients of each plasticizer was $0.9991\sim0.9999$. Therefore this simultaneous analysis method was showed excellent reproducibility and linearity. And limit of detection (LOD) and limit of quantitation (LOQ) on individual plasticizer were $0.1\sim3.5\;ppm\;and\;0.3\sim11.5\;ppm$ respectively. When 143 commercial products of teabag were monitored, no plasticizers analysed were detected in filter of teabag products. The migration into $95^{\circ}C$ water as food was also examined and the 16 plasticizers are not detected. In addition we carried out analysis of heavy metals, lead (Pb), cadmium (Cd), arsenic (As) and aluminum (Al) in teabag filters using ICP/AES. $Trace\sim23{\mu}g$ Pb per teabag and $0.6\sim1718{\mu}g$ Al per teabag were detected in materials of samples and Cd and As are detected less than LOQ (0.05 ppm). The migration levels of Pb and Al from teabag filter to $95^{\circ}C$ water were upto $11.5{\mu}g\;and\;20.8{\mu}g$ per teabag, respectively and Cd and As were not detected in exudate water of all samples. Collectively, these results suggest that there is no safety concern from using teabag filter.

Optimization of Analytical Methods for Octacosanol in Related Health-functional Foods with GC-MS (GC-MS를 이용한 건강기능식품 중 옥타코사놀 분석법 개발 연구)

  • Lee, Jin Hee;Oh, Mi Hyune;Lee, Kyung Jin;Kim, Yang Sun;Keum, Eun Hee;Park, Ji Eun;Cho, Mee Hyun;Seong, Min Hye;Kim, Sang A;Kim, Mee hye
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.4
    • /
    • pp.266-271
    • /
    • 2018
  • The Ministry of Food and Drug Safety (MFDS) is amending its test methods for health-functional foods (dietary food supplements) to establish regulatory standards and specifications in Korea. In this regard, we continue our research on developing analytical methods for the items. Octacosanol is the major component of polycosanol and is a high-molecular-mass primary fatty alcohol, obtained from sugar cane wax. Previous researchers have shown that octacosanol can lower cholesterol and has antiaggregatory properties, cytoprotective uses, and ergogenic properties for human health. Recently, octacosanol products have been actively introduced into the domestic market because of their functional biological activity. We have developed a sensitive and selective test method for octacosanol that the TMS derivatives by means of gas-chromatographic-tandem mass spectrometry (GC-MS). The trimethylsilyl ether derivative of the target analyte showed excellent chromatographic properties. The procedure was validated in the range of $12.5{\sim}200{\mu}g/L$. Standard calibration curves presented linearity with the correlation coefficient ($r^2$) > 0.999, and the limits of detection (LOD) and limits of quantitation (LOQ) were $4.5{\mu}g/L$ and $13.8{\mu}g/L$, respectively. The high recoveries (92.5 to 108.8%) and precision (1.8 to 2.4%) obtained are in accordance with the established validation criteria. Our research can provide scientific evidence to amend the octacosanol test method for the Health-Functional Food Code.

A Study of Current Status on Pesticide Residues in Commercial Dried Agricultural Products (서울시 유통 건조농산물 중의 농약잔류 실태 연구)

  • Kim, Bog-Soon;Park, Seoung-Gyu;Kim, Mi-Sun;Cho, Tae-Hee;Han, Chang-Ho;Jo, Han-Bin;Choi, Byung-Hyun;Kim, Sung-Dan
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.2
    • /
    • pp.114-121
    • /
    • 2007
  • The purpose of this study was to investigate 253 kinds of pesticide residues in 58 commercial dried agricultural products in Seoul. The determinations of the pesticide residues were performed using multiresidue methods and were carried out by a gas chromatography-nitrogen phosphorus detector (GC-NPD), an electron capture detector ($GC-{\mu}ECD$), a mass spectrometry detector (GC-MSD) and high performance liquid chromatography-ultraviolet detector (HPLC-UV), and a fluorescence detector (HPLC-FLD). The pesticide residue detection rate in the commercial dried agricultural products was 24.1% (14 of 58 samples). Twelve pesticide residues without maximum residue limits (MRLs) were detected. In the vegetable groups, the frequency of pesticide residues was found to be in the increasing order of dried fruiting vegetables > dried leafy vegetables > dried stalk and stem vegetables. The pesticides used on dried red pepper in the dried fruiting vegetables were varied (7 kinds) and numerous (4 of 8 samples). The pesticide types detected in the commercial dried agricultural products were in the order of pyrethroid > organochloride > organophosphorus and insecticide > fungicide > herbicide ${\cdot}$ nematicide. The primary pyrethroid pesticide detected was cypermethrin. According to the producing areas of products, large numbers of pesticide residues were found in the order of Korea, China, North Korea, USA, and Vietnam.