• 제목/요약/키워드: Gas Clean Up

검색결과 147건 처리시간 0.02초

고온수소 전환 반응기에 관한 수치해석적 연구 (Numerical Study on High Temperature CO-Shift Reactor in IGFC)

  • 서동균;이진향;지준화;홍진표;오석인
    • 한국수소및신에너지학회논문집
    • /
    • 제29권4호
    • /
    • pp.324-330
    • /
    • 2018
  • In this study a numerical study was conducted to show flow, temperature and gas distributions in a high temperature CO shift reactor which was designed specially for energy saving and then evaluated with the related experiment. Mole fractions of syngas at the end of the catalyst bed were predicted with various assumed pre-exponential factors, were compared with the corresponding experimental results and $10^8$ was finally selected as the value. With the selection, a base case was examined. It was calculated that the inlet duct attached asymmetrically to the CO shift reactor affects on the distribution of the upward momentum (+z directional). In addition, CO conversion ratio is achieved up to 90% in the catalyst bed and especially it reached up to 70% at the initial part of catalyst bed.

Experimental Study on Hydrogen Direct Reduction of Hematite in a Lab Scale Fluidized Bed Reactor by Estimating the Gas Consumption Rate

  • Hasolli, Naim;Jeon, Seong Min;Park, Young Ok;Kim, Yong Ha
    • 청정기술
    • /
    • 제21권2호
    • /
    • pp.96-101
    • /
    • 2015
  • 수소를 환원제로 사용한 산화철의 유동 환원에서, 환원율에 대한 다양한 공정 변수를 통해 산화철의 하나인 적철광의 환원 거동을 면밀히 관찰하였다. 본 연구를 위해 특별히 설계된 실험실 규모의 유동층 장치에서 목적으로 하는 환원 특성에 대한 가스 속도, 환원 시간 및 온도의 최적 값을 평가 하였다. 최적의 환원율을 나타낸 온도는 750 ℃, 환원 시간은 30분이며 이들을 다음의 시험을 위한 시작점으로 매개 변수 값을 설정 하였다. 가장 높은 관심을 갖는 변수들 중 하나는 가스의 소비 원단 위로, 이는 최적의 조건에서 산화철 1톤을 기준하여 90% 이상의 환원율을 달성하기 위해 요구되는 가스의 양을 말한다. 이 매개 변수는 실험실 수준 장치의 스케일 엎에 있어서 중요한 인자이며, 본 연구를 통해 1,500 Nm3/ton-ore가 산화철이 가장 높은 환원율을 갖기 위한 최적의 가스 소비 원단위 임을 확인하였다.

탈설계점 효과를 고려한 석탄가스화 복합발전용 가스터빈의 성능평가 (Performance Evaluation of the Gas Turbine of Integrated Gasification Combined Cycle Considering Off-design Operation Effect)

  • 이찬;김용철;이진욱;김형택
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.209-214
    • /
    • 1998
  • A thermodynamic simulation method is developed for the process design and the performance evaluation of the gas turbine in IGCC power plant. The present study adopts four clean coal gases derived from four different coal gasification and gas clean-up processes as IGCC gas turbine fuel, and considers the integration design condition of the gas turbine with ASU(Air Separation Unit). In addition, the present simulation method includes compressor performance map and expander choking models for considering the off-design effects due to coal gas firing and ASU integration. The present prediction results show that the efficiency and the net power of the IGCC gas turbines are seperior to those of the natural gas fired one but they are decreased with the air extraction from gas turbine to ASU. The operation point of the IGCC gas turbine compressor is shifted to the higher pressure ratio condition far from the design point by reducing the air extraction ratio. The exhaust gas of the IGCC gas turbine has more abundant wast heat for the heat recovery steam generator than that of the natural gas fired gas turbine.

  • PDF

A Synthesis of Optically Active cis and trans 2-(5-Hydroxypoperidin-2-yl)acetates

  • P.N. Reddy;한상수;정교현
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권6호
    • /
    • pp.617-618
    • /
    • 1998
  • A simple and reproducible pretreatment method was developed for the determination of dioxins in milk sample. Liquid-liquid extraction (LLE) was used for the initial extraction of the analyte from milk. For the elimination of interferences coextracted from milk, acid treatment followed by multilayer silica gel, and then alumina column clean-up were performed. The clean extract could be obtained without carbon column or high performance liquid chromatographic (HPLC) clean-up procedure. Polychlorinated biphenyles (PCBs) and dioxins were separated on neutral alumina activated at 180 ℃ for 12 hours. The final extract was analyzed by HPLC and high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS). The recovery of dioxins spiked in milk at 75-300 ppt level was 83.3-98.9% and their relative standard deviation was 4.1-14%.

Analytical Method for Dioxin and Organo-Chlorinated Compounds : (I) Pretreatment of Milk Samples for Dioxin Analysis

  • 양정수;김진영;최용욱;이대운
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권6호
    • /
    • pp.619-624
    • /
    • 1998
  • A simple and reproducible pretreatment method was developed for the determination of dioxins in milk sample. Liquid-liquid extraction (LLE) was used for the initial extraction of the analyte from milk. For the elimination of interferences coextracted from milk, acid treatment followed by multilayer silica gel, and then alumina column clean-up were performed. The clean extract could be obtained without carbon column or high performance liquid chromatographic (HPLC) clean-up procedure. Polychlorinated biphenyles (PCBS) and dioxins were separated on neutral alumina activated at 180 ℃ for 12 hours. The final extract was analyzed by HPLC and high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS). The recovery of dioxins spiked in milk at 75-300 ppt level was 83.3-98.9% and their relative standard deviation was 4.1-14%.

대규모 시설을 위한 다채널 가스 누설 경보기 개발 (Development of Multi Channel Gas Leakage Detector for Large Facility)

  • 정규원
    • 한국안전학회지
    • /
    • 제23권3호
    • /
    • pp.1-7
    • /
    • 2008
  • As a clean fuel, LNG or LPG is widely used in large restaurants or plants instead of coal. These fuels are easy to use and cheap. However, they are inflammable very much and easily exploded at the worst. So there are many laws and regulations legislated for the handling and usage of the gas facilities. Nevertheless, very harsh explosions occurred in several domestic or foreign places. In this paper a gas detection and alarm system was developed for large facilities. A new concept for connecting many gas detectors was proposed and based upon that a system including hardware and software have been developed and tested. Although up to 16 gas detectors apart 1 km from main controller can be connected currently, this system can be easily expanded for more detectors because each gas detector receiver communicates with main controller using industrial standard RS-485 multi drop technique. Furthermore several additive functions was included for the installation and maintenance convenience.

PERSPECTIVES OF NUCLEAR HEAT AND HYDROGEN

  • Lee, Won-Jae;Kim, Yong-Wan;Chang, Jong-Hwa
    • Nuclear Engineering and Technology
    • /
    • 제41권4호
    • /
    • pp.413-426
    • /
    • 2009
  • Nuclear energy plays an important role in world energy production by supplying 6% of the world's current total electricity production. However, 86% of the energy consumed worldwide to produce industrial process heat, to generate electricity and to power the transportation sector still originates in fossil fuels. To cope with dwindling fossil fuels and climate change, it is clear that a clean alternative energy that can replace fossil fuels in these sectors is urgently required. Clean hydrogen energy is one such alternative. Clean hydrogen can play an important role not only in synthetic fuel production but also through powering fuel cells in the anticipated hydrogen economy. With the introduction of the high temperature gas-cooled reactor (HTGR) that can produce nuclear heat up to $950^{\circ}C$ without greenhouse gas emissions, nuclear power is poised to broaden its mission beyond electricity generation to the provision of nuclear process heat and the massive production of hydrogen. In this paper, the features and potential of the HTGR as the energy source of the future are addressed. Perspectives on nuclear heat and hydrogen applications using the HTGR are discussed.

사과 중 Nuarimol의 잔류성 분석 (Analysis of Residual Nuarimol in Apples)

  • 김일광;한성수;김윤근;김해진
    • 분석과학
    • /
    • 제6권3호
    • /
    • pp.283-288
    • /
    • 1993
  • 기체 크로마토그래피를 이용하여 과수 재배용 살균제인 nuarimol의 분석을 위한 최적 조건을 조사하고 사과 중에서의 잔류성을 규명하였다. 사과시료를 methanol로 추출, 여과한 후 4.00% NaCl과 dicholromethane액으로 분리농축하고, alumina 컬럼상에서 1-chlorobutane과 methanol 혼합액으로 정제하여 GLC/ECD로 분석하였다. 0.200와 1.00ppm 표준물 첨가 실험결과 평균 회수율이 79~95%였고, 사과 중 nuarimol의 잔류량은 수확 3일 전 8회 처리시 0.0830ppm이었다. 사과에 대한 안전 사용기간은 수확 7일전 6회 사용이 적당한 것으로 나타났다.

  • PDF