• Title/Summary/Keyword: Gas Chromatography/Mass Spectrometry

Search Result 985, Processing Time 0.03 seconds

Exploring the Metabolomic Responses of Bacillus licheniformis to Temperature Stress by Gas Chromatography/Mass Spectrometry

  • Dong, Zixing;Chen, Xiaoling;Cai, Ke;Chen, Zhixin;Wang, Hongbin;Jin, Peng;Liu, Xiaoguang;Permaul, Kugenthiren;Singh, Suren;Wang, Zhengxiang
    • Journal of Microbiology and Biotechnology
    • /
    • v.28 no.3
    • /
    • pp.473-481
    • /
    • 2018
  • Owing to its high protein secretion capacity, simple nutritional requirements, and GRAS (generally regarded as safe) status, Bacillus licheniformis is widely used as a host for the industrial production of enzymes, antibiotics, and peptides. However, as compared with its close relative Bacillus subtilis, little is known about the physiology and stress responses of B. licheniformis. To explore its temperature-stress metabolome, B. licheniformis strains ATCC 14580 and B186, with respective optimal growth temperatures of $42^{\circ}C$ and $50^{\circ}C$, were cultured at $42^{\circ}C$, $50^{\circ}C$, and $60^{\circ}C$ and their corresponding metabolic profiles were determined by gas chromatography/mass spectrometry and multivariate statistical analyses. It was found that with increased growth temperatures, the two B. licheniformis strains displayed elevated cellular levels of proline, glutamate, lysine, pentadecanoic acid, hexadecanoic acid, heptadecanoic acid, and octadecanoic acid, and decreased levels of glutamine and octadecenoic acid. Regulation of amino acid and fatty acid metabolism is likely to be associated with the evolution of protective biochemical mechanisms of B. licheniformis. Our results will help to optimize the industrial use of B. licheniformis and other important Bacillus species.

Simultaneous Determination of Urinary Phytoestrogens and Estrogens by Gas Chromatography/Mass spectrometry (GC/MS에 의한 뇨 중 Phytoestrogen과 Estrogen의 동시 분석)

  • Yang, Yoon Jung;Lee, Seon Hwa;Chung, Bong Chul
    • Analytical Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.374-385
    • /
    • 1998
  • Phytoestrogens are biologically active compounds derived from plants foods. It had been suggested that phytoestrogens, by inhibiting aromatase in peripheral and/or cancer cells and lowering estrogen levels, may play a protective role as antipromotional compounds during growth of estrogen-dependent cancers. Therefore, simultaneous analysis of estrogens and phytoestrogens is necessary to elucidate the possible involvement of phytoestrogens in estrogen metabolism. In this view, we developed a simple and reproducible procedure to quantitatively determine estrogen and phytoestrogen metabolites. The proposed method consisted of solid phase extraction using preconditioned Serdolit AD-2 resin, enzyme hydrolysis with ${\beta}$-glucuronidase/arylsulfatase from Helix pomatia, liquid-liquid extraction and TMS-ether derivatization. And the final determination was carried out by gas chromatography/mass spectrometry (GC/MS) in selected ion monitoring mode (SIM). The precision and accuracy of this method was evaluated through within-a-day and day-to-day test. Recovery range and detection limit were 71.96~105.66%, 2~4 ng/mL, respectively. Using this method, 17 estrogen and 5 phytoestrogen compositions in urine of normal subjects were analyzed. It was found that amounts and relative distribution of urinary phytoestrigens and estrogens showed different pattern in male and female subjects.

  • PDF

Analysis of Synthetic Fragrances (SFs) in Water Using Stir Bar Sorptive Extraction (SBSE) and GC-MS/MS (교반막대 추출법과 GC-MS/MS를 이용한 수중의 합성 향물질류 분석)

  • Seo, Chang-Dong;Son, Hee-Jong;Yoom, Hoon-Sik;Choi, Jin-Taek;Ryu, Dong-Choon;Kwon, Ki-Won;Jang, Seung-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.6
    • /
    • pp.387-395
    • /
    • 2014
  • A highly sensitive analytical method based on stir bar sorptive extraction (SBSE) technique and gas chromatography/tandem mass spectrometry (GC-MS/MS) has been developed, allowing the simultaneous multi-analyte determination of 11 synthetic fragrances (SFs) in water samples. The stir bar coated with polydimethylsiloxane (PDMS) was added to 40 mL of water sample at pH 3 and stirred at 1,100 rpm for 120 min. Other SBSE parameters (salt effect and presence of organic solvent) were optimised. The method shows good linearity (coefficients > 0.990) and reproducibility (RSD < 10.9%). The extraction efficiencies were above 83% for all the compounds. The limits of detections (LOD) and limits of quantification (LOQ) were 2.1~4.1 ng/L and 6.6~12.9 ng/L, respectively. The developed method offers the ability to detect 11 SFs at ultra-low concentration levels with only 40 mL of sample volume. Matrix effects in tap water, river water, wastewater treatment plant (WWTP) final effluent water and seawater were investigated and it was shown that the method is suitable for the analysis of trace level of 11 SFs. The method developed in the present study has the advantage of being rapid, simple, high-sensitive and both user and environmentally friendly.

Determination of the presence of benzene in vitamin drinks using headspace - solid phase microextraction and gas chromatography - mass spectrometry (Headspace Solid Phase Microextraction-Gas Chromatography/Mass Spectrometry를 이용한 비타민드링크 제품 중 Benzene의 미량분석)

  • Kim, Jong-Hun;Lee, Kyung-Min
    • Analytical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.237-245
    • /
    • 2007
  • The presence of benzene in 31 products of vitamin drinks purchased from 20 retail outlets was determined using headspace solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS). The sample (25 ml) was stirred at 1200 rpm for 4 min using a magnetic bar with a $100{\mu}m$ SPME fiber as an adsorbent for benzene which was then desorbed from the fiber for 1 min in the GC injector. Quantitation was achieved using the standard addition method. The limit of detection was determined as 0.56 ng/ml and over a concentration range 0-40 ng/ml the coefficient of correlation was greater than 0.999. The concentration of benzene in the drinks examined was in the range not detectable to 47.35 ng/ml. Benzene was detected in 15 of the drinks with concentration in 5 of them greater than 10 ng/ml which is the limit set for the presence of benzene in the Drinking Water Regulations. The concentrations of benzene in the 5 drinks which exceeded the limit of 10 ng/ml were 16.99, 35.14, 16.03, 47.35 and 14.28 ng/ml respectively.

Simultaneous quantitative determination of urinary cholesterol, desmosterol and lanosterol in pravastatin treated rats by gas chromatography/mass spectrometry (Gas Chromatography/Mass Spectrometry를 이용한 Pravastatin 투여 쥐의 뇨 중 Cholesterol, Desmosterol, Lanosterol의 동시분석법)

  • Kumar, Bhowmik Salil;Chung, Bong Chul;Lee, Young-Joo;Yi, Hong Jae;Jung, Byung Hwa
    • Analytical Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.407-414
    • /
    • 2009
  • A simultaneous determination method for cholesterol, lanosterol and desmosterol was developed using gas chromatography/mass spectrometry. Urine was enzymatically hydrolyzed with ${\beta}$-glucuronidase/arylsulfatase. Samples were prepared using extractions with a mixture of ethyl acetate-hexane (2:3, v/v), followed by derivatization with a mixture of MSTFA/TMSI/TMCS (100:2:5 v/v/v). All analyses were performed using GC/MS in selective ion monitoring mode. Good linearities ($r^2=0.998{\sim}0.999$) in calibration curve and a satisfactory recovery (80.0%~113%) were achieved. Accuracy and precision values within ${\pm}15%$ in the concentration range of 5 to 200 ng/mL were also observed for all compounds. The developed method was applied to pravastatin-treated (70 and 250 mg/kg/day for 7 days, oral) hyperlipidemia rats. Those sterols were significantly lower in drug-treated rats compared to the controls, which justifies the drug efficacy. Therefore, these results indicate that the developed method was successfully applied to examine statin drug efficacy with urine sample.

Multichannel Liquid Phase Microextraction System (다채널 액상 미세 추출 시스템 설계 및 제작)

  • Zhang, XinJie;Cheng, Shuo;Piao, Xiang Fan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.10
    • /
    • pp.1-7
    • /
    • 2020
  • In this study, a multichannel gas-liquid microextraction system is designed by integrating the automatic elution of extraction line and multichannel gas-purging liquid phase microextraction. The system uses an injection pump and inert gas to push the extraction solvent to a sample bottle of a gas-phase color autosampler and then implements multichannel gas-liquid microextraction and gas chromatography-mass spectrometry. The system also employs a three-way integrated micro-high-temperature heater, syringe pump, and microflow controller to realize the simultaneous processing of multiple groups of samples, thus improving the sample pretreatment speed and reproducibility and reducing human error. Autoinjection experiments were implemented with polycyclic aromatic hydrocarbon standard samples. The experiments show that the average recovery rate of the system exceeds 70%, and the relative standard among the channels is less than 15%.

Analysis of Volatile Organic Compounds in Water by Modified Injection Mode for Purge & Trap-GC/MS Method (Purge & Trap-GC/MS 분석법의 주입방식 개선에 의한 물 중의 휘발성 유기물 분석)

  • Jeon, Chi Wan;Lee, Sang Hak;Eum, Chul Hun
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.8
    • /
    • pp.635-642
    • /
    • 1995
  • Improved sample introduction system has been investigated for the determination of volatile organic compounds in water using a purge & trap preconcentration apparatus and a capillary gas chromatography/mass spectrometry. The present limitations associated with the moisture control module and cryorefocusing system suggested by EPA were discussed. To solve the problems such as improper separation of peaks due to the adsorption of water and contamination of purge & trap system, a more efficient connection system between the purge & trap apparatus and the gas chromatograph was introduced and the optimum operational conditions were suggested. A carbopack B/carboxen 1000 and 1001 trap was used for the purge & trap procedure and a custom made crosslinked dimethyldiphenylpolysiloxane capillary column was used for the separation of compounds. Accuracy and precision of the method suggested in this report were examined and the method detection limit of each compound was proposed for the simultaneous determination of 54 volatile organic compounds in water.

  • PDF

Rapid Determination of Ginkgolic Acids in Ginkgo biloba Leaf Using Online Column Switching High-Performance Liquid Chromatography-Diode Array Detection and Confirmation by Liquid Chromatography-tandem Mass Spectrometry

  • Lee, Hyounyoung;Lim, Heungyoul;Yang, Juhong;Hong, Jongki
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.12
    • /
    • pp.3629-3634
    • /
    • 2013
  • In this study, an improved method for the quantitative analysis of ginkgolic acids (GAs) in Ginkgo biloba leaf extract was developed. The samples were extracted with a mixture of chloroform and 50 % ethanol, after which the chloroform extract was dried and reconstituted in methanol. GAs with 13:0, 15:1, and 17:1 in the extract were successfully separated within 40 min and determined with high throughput performance using an online column-switching HPLC method using an SP column C8 SG80 ($4.6{\times}150mm$, $5{\mu}m$) and a Cadenza 5CD C18 column ($4.6{\times}150mm$, $3{\mu}m$). The developed HPLC method was validated for Ginkgo biloba leaf extract. The validation parameters were specificity, linearity, precision, accuracy, and limits of detection and quantitation (LODs and LOQs, respectively). It was found that all of the calibration curves showed good linearity ($r^2$ > 0.9993) within the tested ranges. The LODs and LOQs were all lower than $0.04{\mu}g/mL$. The established method was found to be simple, rapid, and high throughput for the quantitative analysis of GAs in ten commercial Ginkgo biloba leaf extract and dietary supplements. The samples were also analyzed in LC-electrospray ionization (ESI) tandem mass spectrometry (MS/MS) - multiple-ion reaction monitoring (MRM) mode to confirm the identification results that were obtained by the column switching HPLC-DAD method. The developed method is considered to be suitable for the routine quality control and safety assurance of Ginkgo biloba leaf extract.

Determination of bisphenol-A using GC/MS in Can Materials (기체크로마토그래피/질량분석법을 이용한 캔 물질에서의 bisphenol-A 분석)

  • Kim, Ki-Cheol;Kim, Yang-Hee;Choi, Ok-Kyung;Ko, Hoan-Uck;Yim, Jun-Rae;Choi, Kyo-Hong;Cho, Hyun-Woo;Kim, Hye-Young;Kim, Myungsoo;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.499-503
    • /
    • 2001
  • A new simple, rapid and sensitive gas chromatographic technique for the determination of bisphenol-A in can materials, which is the major material of epoxy resin and polycarbonate polymer, is proposed. This method is characterised by derivatization of the bisphenol-A with a acylating reagent forming the acetate derivative to optimize the chromatographic property. The detection of bisphenol-A is performed based on GC/MS (gas chromatography/mass spectrometry). Several beverages were analyzed by the proposed method for the determination of bisphenol-A Bisphenol-A was assayed the range of $0.11{\sim}11.40{\mu}g/can$ from the can materials.

  • PDF

Effect of Ultrasonic Irradiation on On-board Fuel Analyzed Using Gas Chromatography/Mass Spectrometry (GC/MS를 이용한 선박연료유에 대한 초음파조사 효과 분석)

  • Choi, Jung-Sik
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.6
    • /
    • pp.890-897
    • /
    • 2021
  • Since the enforcement of strict regulations on marine fuel oil sulfur content, demand for Low Sulfur Fuel Oil (LSFO) has been increasing. However, as LSFO properties vary greatly depending on the supply timing, region, and supplier, LSFOs can experience problems with sludge formation, blending compatibility, and stability once mixed into storage tanks. This study investigates using ultrasound cavitation effects to improve the quality of LSFOs in storage tanks. For marine gas oil (MGO), the results showed that the relative ratio of high molecular weight compounds to those of low molecular weight decreased after ultrasonic irradiation, due to cavitation-induced cracking of chemical bonds. For marine diesel oil (MDO) and blended oil, a small increase in the relative abundance of low weight molecular compounds was observed after treatment. However, no correlation between time and relative abundance was observed.