• Title/Summary/Keyword: Gas Amount

Search Result 2,677, Processing Time 0.031 seconds

A Study on the Calculation Formulae of Required Air and Burning Gas Amount of Heavy Fuel Oil (중유의 연소에 필요한 소요공기량과 발생가스량의 산식에 관한 연구)

  • 이우환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.34-40
    • /
    • 1982
  • The characteristics of typical 17 kinds of fuel oils are studied to fine the calculation formulae for the required amount of air and the combustion gas amount. 1) The author's calculation formulae are as follows; (1) Theoretically required amount of air (2) Theoretical amount of combustion gas 2) Theoretical amount of the required air in combustion and combustion gas of fuel oils are always estimated less with Rosin's formula than with author's one. 3) Theoretical amount of the required air and the amount of combustion gas of fuel oils are more reasonable with author's formula than Rosin's one in comparison with results of actual analysis.

  • PDF

Estimate Minimum Amount of Methane for Explosion in a Confined Space (밀폐공간에서 메탄 폭발사고의 최소 가스누출량 예측)

  • Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.4
    • /
    • pp.1-5
    • /
    • 2017
  • Leaking of natural gas, which is mostly methane, in a confined living space creates flammable atmosphere and gives rise to explosion accident. The minimum amount of leaked methane for explosion is highly dependent on the degree of mixing in the confined space. This paper proposes a method for estimating minimum amount of flammable gas for explosion by using Gaussian distribution explosion model(GDEM) and experimental explosion data. The explosion pressure in the confined space can be estimated by assuming the Gaussian distribution of flammable gas along the height of an enclosure and estimating the maximum amount of gas within flammable limits, combustion of the estimated gas with constant volume and adiabatic or isothermal mixing in the confined space. The predicted minimum gas amount for an explosion is tied to explosion pressure that results in a given building damage level. The result shows that very small amount of methane leaking in the confined space may results in a serious gas explosion accident. This result could be applied not only to setting the leak criteria for developing a gas safety appliance but also to accident investigating of explosion.

Risk Analysis of Explosion in Building by Fuel Gas

  • Jo, Young-Do;Park, Kyo-Shik;Ko, Jae Wook
    • Corrosion Science and Technology
    • /
    • v.3 no.6
    • /
    • pp.257-261
    • /
    • 2004
  • Leaking of fuel gas in a building creates flammable atmosphere and gives rise to explosion. Observations from accidents suggest that some explosions are caused by quantity of gas significantly less than the lower explosion limit amount required to fill the whole confined space, which might be attributed to inhomogeneous mixing of the leaked gas. The minimum amount of leaked gas for explosion is highly dependent on the degree of mixing in the building. This paper proposes a method for estimating minimum amount of flammable gas for explosion assuming Gaussian distribution of flammable gas.

The Study on Methane Gas Generation Rate from Chon-An Beck-Suk Landfill Site (천안백석매립장을 중심으로 한 메탄가스 발생량에 관한 연구)

  • Jeong, Jin Do;Kim, Jang U;Jeong, In Gwon;Bae, Chan Yeol
    • Journal of Environmental Science International
    • /
    • v.13 no.7
    • /
    • pp.697-701
    • /
    • 2004
  • Most of methane gas result from waste matter in landfill, therefore the persons concerned take an increasing interest in management of gases in landfill. Infrared Gas Analyzer was used to measure components of gases, $CH_4,$ $CO_2,$ $O_2,$ through gas exhausted pipe. To measure amount of the gas flow meter(Portable Hot-Line Current Meter) was used and it was set at right angles with direction of the flow. In this research the total amount of methane gas produced in Beck-Suk Landfill was calculated through FOD method suggested by IPCC. This research found that in Chon-An Beck-Suk Landfill anaerobic resolution was made actively and the amount of methane gas produced there was 54.14%, which is higher than common figure, 50%, in other researches. The components of reclaimed waste matter, especially, organic waste matter can have a great effect of the amount of the greenhouse gases produced in landfill. We can expect that the amount of greenhouse gas will decrease from 2005, when it will be prohibited from carrying kitchen refuse and sludge into landfill.

An Establishment of Greenhouse Gas Information System using Excel Spreadsheets (엑셀 스프레드시트를 활용한 온실가스 정보시스템 구축)

  • Lee, Hae-Jung;Chung, Young-Bae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.40 no.4
    • /
    • pp.129-136
    • /
    • 2017
  • Climate change is the biggest environmental issue of our times. A variety of activities to reduce greenhouse gas emissions have been in progress to observe the Kyoto Protocol. Especially, the Energy Target Scheme is created to reduce greenhouse emission with the supervision of Korean government. This includes Green-house Gas Information Systems to promote activities in the private sector to reduce green-house gas emissions, to cut a cost of energy use, and to reduce GHG emissions. Also, the system has calculated the amount of greenhouse gases. Without any additional investment, 2.75% savings are increased over the previous year. In service sector, a cooperation of customers and employees is necessary. A reduction of GHG emissions requires a proper service organization, considering an amount of investment and payback period. Without any additional investment or replacement, employees can save energy easily turning off ventilation systems an hour before employees' departure, installing timers to turn off water purifiers and vending machines after some period of no use. The Green-house Gas Information System is similar to that of Environmental Management System. However, the Excel is the best program to calculate an amount of green-house gas emissions, and to assess for a reduced amount of GHG emissions. A goal of this research is to propose a practical method in the private sector to calculate an amount of green-house gases. The Green-house gas Information System based on Excel spreadsheet gives standards for good evaluation. The greenhouse gas information system establishes and executes the policies and objectives related to greenhouse gas emissions Similar to ISO 14001 environment management system structures, the advantages of using simplified Excel Sheet for calculating GHG emissions and reducing GHG emissions are easy to access.

Study on the Measurement of GHG Emissions and Error Analysis in Form the MSW Incineration Plant Equipment with the Recovery Heat System (2009~2013) (폐열회수시설이 설비된 생활폐기물 소각자원화시설 온실가스 배출량 산정 시 오차분석 (2009~2013))

  • Choi, Won-Geun;Seo, Ran-Sug;Park, Seung-Chul
    • Journal of Environmental Science International
    • /
    • v.25 no.2
    • /
    • pp.239-246
    • /
    • 2016
  • This study aims to analyze region-specific trends in changing greenhouse gas emissions in incineration plants of local government where waste heat generated during incineration are reused for the recent five years (2009 to 2013). The greenhouse gas generated from the incineration plants is largely $CO_2$ with a small amount of $CH_4$ and $N_2O$. Most of the incineration plants operated by local government produce steam with waste heat generated from incineration to produce electricity or reuse it for hot water/heating and resident convenience. And steam in some industrial complexes is supplied to companies who require it for obtaining resources for local government or incineration plants. All incineration plants, research targets of this study, are using LNG or diesel fuel as auxiliary fuel for incinerating wastes and some of the facilities are using LFG(Landfill Gas). The calculation of greenhouse gas generated during waste incineration was according to the Local Government's Greenhouse Emissions Calculation Guideline. As a result of calculation, the total amount of greenhouse gas released from all incineration plants for five years was about $3,174,000tCO_2eq$. To look at it by year, the biggest amount was about $877,000tCO_2eq$ in 2013. To look at it by region, Gyeonggido showed the biggest amount (about $163,000tCO_2eq$ annually) and the greenhouse gas emissions per capita was the highest in Ulsan Metropolitan City(about $154kCO_2eq$ annually). As a result of greenhouse gas emissions calculation, some incineration plants showed more emissions by heat recovery than by incineration, which rather reduced the total amount of greenhouse gas emissions. For more accurate calculation of greenhouse gas emissions in the future, input data management system needs to be improved.

Effects of the Impurity Gases on the Characteristics of ac PDP

  • Shin, Joong-Hong;Park, Chung-Hoo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.10
    • /
    • pp.909-913
    • /
    • 2002
  • The luminance and discharge characteristics of ac PDP may be significantly affected by a small amount of impurity gas in working gas. These impurity gases such as O$_2$, O, C and H$_2$ can be mixed in the manufacturing and /or discharge process. In this paper a small amount of impurity gas in acPDP are introduced quantitatively and the relationship between the amount of impurity gas and the luminance/discharge characteristics are investigated. The luminous efficiency decreased seriously with increase in the partial pressure of impurity gases, especially in H$_2$, O$_2$ and CO$_2$. Under the condition of the impurity gas ratio of 2${\times}$10$\^$-3/ for Ar, N2, H$_2$, CO$_2$ and O$_2$, the luminous efficiency decreased about 8%, 8%, 32%, 36% and 50%, respectively.

A Basic Study on City Gas Consumption Difference according to the exclusive dwelling area

  • Kim, Sang Ho;Yang, Sungpil;Yu, Yeongjin;Son, Kiyoung
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.732-733
    • /
    • 2015
  • Currently, since the total energy amount has been increased continuously, the effort for energy efficiency of apartment building is necessary. Although the previous studies have been focused on the issue. Almost studies are about the simulation by applying the energy analysis tools and a lack of studies have been conducted the data analysis about real city gas amount of apartment building. Therefore, the objective of this study is to analyze the city gas consumption difference according to the exclusive dwelling in apartment building. To address this issue, the descriptive, correlation, analysis of variance (ANOVA) statistics are used in this study. As a result, in the case of annual total amount, the city gas is increased as the size of the exclusive dwelling area is increased. In the future, the findings of this study can be used as a basic material to develop the prediction model of city gas in apartment building.

  • PDF

A Study on the Methodology of Calculating Greenhouse Gas Emission Reduction by HFCs Reduction - Focusing on the Foam Industry - (HFCs 감축에 따른 온실가스 감축량 산정방법론 연구 - 발포산업을 중심으로 -)

  • Choi, Ji Won;Kim, Jung Man;Ahn, Jun Kwan
    • Journal of Climate Change Research
    • /
    • v.9 no.4
    • /
    • pp.399-406
    • /
    • 2018
  • The purpose of this study is to propose a methodology for estimating greenhouse gas emission reduction through HFCs used in the foam industry. This study investigated characteristics of HFCs and greenhouse gas emissions from production processes in the foam industry, which uses HFCs as a blowing agent. Also, we investigated fluorinated gas removal technology to determine a proper technology for the foam industry. And we confirmed the criteria and characteristics of External Project for methodology development. According to criteria of External Project and foam industrial process emission, a methodology for calculating the amount of greenhouse gas emission reduction in foam industry was developed. Lastly, we analyzed the amount of greenhouse gas emission reduction and KOC (Korea Of Offset) in the foam industry based on the domestic government's plan to reduce HCFCs and imported amount of HFCs used as a blowing agent. The results of this study demonstrate that linking greenhouse gas reduction in the foam industry and the domestic greenhouse gas reduction system can contribute to achieve the domestic greenhouse gas reduction goal.

Estimation of Exhaust Gas Recirculation using In-Cylinder Residual Gas Fraction in an SI Engine (잔류가스 추정 기법을 이용한 EGR율의 예측)

  • 김득상;김성철;황승환;조용석;엄인용
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.55-60
    • /
    • 2004
  • Residual gas acts as a diluent which results in reducing the in-cylinder temperature as well as the flame speed, significantly affecting fuel economy, NOx emissions and combustion stability. Therefore it is important to determine the residual gas fraction as a function of the engine operating parameters accurately. However, the determination of the residual gas fraction is very sophisticated due to the unsteady state of induction and exhaust process. There has been little work toward the development of a generally applicable model for quantitative predictions of residual gas fraction. In this paper, a simple model for calculating the residual gas fraction in SI engines was suggested. The amount of fresh air was evaluated through AFR and fuel consumption. After this, from the intake temperature and pressure, the amount of total cylinder-charging gas was estimated. The residual gas fraction was derived by comparing the total charging and fresh air. This results coincide with measured EGR value very well.