• Title/Summary/Keyword: Gap gas

Search Result 625, Processing Time 0.027 seconds

Design of gas-gap thermal switch for reducing cooldown time of 2-stage cryocooler (2단 냉동기의 냉각시간 단축을 위한 기체-간극 열스위치 설계)

  • 김형진;장호명
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2000.02a
    • /
    • pp.35-38
    • /
    • 2000
  • A preliminary design of gas-gp thermal switch is presented to reduce the cooldown time of superconducting system conduction-cooled by a two-stage refrigerator without liquid cryogens. The switch connects thermally the first and the second stages (ON) to take advantage of the larger refrigeration capacity at the first stage during the beginning period. After the cryogenic temperature is reached, the switch should isolate thermally the two stages (OFF) in order to reduce the heat leak to the cold end. In this paper, a new concept for the performance index is introduced to evaluate the reduction of the cooldown time and the increase of the cooling load at the same time. In addition, the design of a gas-gap switch is discussed as a closed container of several staggered concentric tubes filled with gas, which is frozen at low temperatures for the shut-off of heat without any mechanical actuation. Some of the detailed features in the design is quantitative investigated by the gas convection model in the continuum or the rarefied gas region.

  • PDF

Comparative study of air gap, direct contact and sweeping gas membrane distillation configurations

  • Loussif, Nizar;Orfi, Jamel
    • Membrane and Water Treatment
    • /
    • v.7 no.1
    • /
    • pp.71-86
    • /
    • 2016
  • The present study deals with a numerical simulation for the transport phenomena in three configurations of Membrane Distillation (Air Gap, Direct Contact and Sweeping Gas Membrane Distillation) usually used for desalination in order to make an objective comparison between them under the same operating conditions. The models are based on the conservation equations for the mass, momentum, energy and species within the feed saline and cooling solutions as well as on the mass and energy balances on the membrane sides. The theoretical model was validated with available data and was found in good agreement. DCMD configuration provided the highest pure water production while SGMD shows the highest thermal efficiency. Process parameters' impact on each configuration are also presented and discussed.

A research on the discharge characteristics of Xe-Kr-Ne mixture gas in discharge gap and gas pressure of ac-PDP (AC-PDP의 방전갭과 가스압력에 따른 Xe-Kr-Ne mixture gas 방전특성 연구)

  • Han, Moon-Ki;Ha, Chang-Seung;Lee, Don-Kyu;Lee, Hae-June;Lee, Ho-Jun;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.171-172
    • /
    • 2007
  • PDP의 luminous efficacy의 향상을 위해서는 동작가스의 연구가 매우 중요하다. 본 논문에서는 bolsig simulator를 사용하여 여러 비율의 Xe+Kr+Ne 3원가스 시뮬레이션을 통하여 각 가스입자들에 전달되는 이온화에너지, 여기에너지를 조사하였다. 실험에서 short discharge gap과 long discharge gap을 가진 7인치 테스트 패널 2개를 사용하여 가스압력과 Xe+Kr+Ne 혼합비를 변화시켜가며 discharge voltage, luminance, luminous efficacy를 측정하여, 방전특성을 연구하였다.

  • PDF

A Study on the Combustion Flow Characteristic and NOx Reduction of the Exhaust Gas Recurculation Burner using Coanda Nozzles (코안다 노즐을 이용한 배기가스 재순환 버너의 연소 유동 특성 및 NOx 저감에 관한 연구)

  • Ha, Ji Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.3
    • /
    • pp.53-60
    • /
    • 2017
  • Various researches have been conducted for the reduction of NOx at the combustion furnace and exhaust gas recirculation method is commonly used technology for NOx reduction. The present research adopted coanda nozzles at the outside pipes of furnace to entrain the exhaust gas for the exhaust gas recirculation and the mixed gas was ejected to the tangential direction to cause the swirl flow in the furnace. The combustion flow characteristics in the exhaust gas recirculation burner with coanda nozzle has been elucidated by analyzing the swirl flow streamlines, temepraure and reaction rate distribution in the furnace. The exhaust gas entrained flow rate has been investigated by changing the excess air factor and coanda nozzle gap and the exhaust gas entrained flow rate increased with the increase of excess air factor and it decreased with the increase of coanda nozzle gap. The mean temperature at the exit plane of exhaust gas decreased with the excess air factor and it was little affected by the increase of coanda nozzle gap. The NOx mass fraction at the exhaust gas exit plane remarkably decreased with the excess air factor and it was also little affected by the increase of coanda nozzle gap.

Heat Energy Diffusion Analysis in the Gas Sensor Body with the Variation of Drain-Source Electrode Distance (드레인-소스 전극 간극의 변화에 따른 Gas Sensor의 열에너지 확산 해석)

  • Jang, Kyung-Uk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.9
    • /
    • pp.589-595
    • /
    • 2017
  • MOS-FET structured gas sensors were manufactured using MWCNTs for application as NOx gas sensors. As the gas sensors need to be heated to facilitate desorption of the gas molecules, heat dispersion plays a key role in boosting the degree of uniformity of molecular desorption. We report the desorption of gas molecules from the sensor at $150^{\circ}C$ for different sensor electrode gaps (30, 60, and $90{\mu}m$). The COMSOL analysis program was used to verify the process of heat dispersion. For heat analysis, structure of FET gas sensor modeling was proceeded. In addition, a property value of the material was used for two-dimensional modeling. To ascertain the degree of heat dispersion by FEM, the governing equations were presented as partial differential equations. The heat analysis revealed that although a large electrode gap is advantageous for effective gas adsorption, consideration of the heat dispersion gradient indicated that the optimal electrode gap for the sensor is $60{\mu}m$.

Dielectric Characteristics of SF$_6$ Gas in Non-uniform Fields (불평등전계중에서 SF$_6$ 가스의 절연특성)

  • 이복희;전덕규;이경옥;안창환;이창준
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.334-337
    • /
    • 1997
  • This paper describes dielectric characteristics of SF$_{6}$ gas stressed by the non-oscillating and oscillating impulse voltages in inhomogeneous fields disturbed by metallic protrusion. The breakdown voltage-time (V-t) characteristics and breakdown voltage-gas pressure (V-p) characteristics and their characteristics are statistically investigated with positive and negative very fast transient overvoltages. The experiments were carried out using a needle-to-plane gap geometry in the gas pressure ranges from 0.1 to 0.5 MPa. The gap separation gas 22 mm, and the needle-shaped protrusions were made of stainless steel 10 mm in length and 1.0 mm in diameter.r.

  • PDF

Counter-Current Gas-Liquid Two-Phase Flow Regimes in Narrow Rectangular Channels (협소 사각 유로에서 대향류 기/액 2상 유동양식)

  • Sohn, B.H.;Kim, B.J.;Jeong, S.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.136-141
    • /
    • 2000
  • A study of counter-current two-phase flow in narrow rectangular channels has been performed. Two-phase flow regimes were experimentally studied in 760 mm long and 100 mm wide test sections with 2.0 and 3.0mm gaps. The resulting data have been compared to previous transition models. For the transition from bubbly to slug flow the superficial velocity of gas increased as the gap width increased. The comparison of experimental data to the transition model developed by Taitel and Barnea showed relatively good agreement for the bubbly-to-slug transition in the case of 2mm gap width. For the criteria of Mishima and Ishii to be applicable to the slug-to-churn transition the distribution parameter should be well defined for narrow channels. Even though the gap width of narrow channels increased the superficial gas velocity did not change for the transition form chum to annular flow regime. For the chum-to-annular transition the model of Taitel and Barnea showed discrepancies with experimental data, especially in the channel with larger gap.

  • PDF

characteristic of breakdown voltage of electrode gap in vacuum (진공에서 극간 gap에 따른 절연파괴 전압 특성 파악)

  • Yoon, Jae-Hun;Kim, Byung-Chul;Lee, Sueng-Su;Lim, Kee-Jo;Kang, Seong-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.366-367
    • /
    • 2008
  • SF6 widely used as insulating gas is rising as the environment problem. For decreasing this greenhouse gas, electrical breakdown characteristics of vacuum with air are studied in non-uniform field. The gap of needle to plane was 0.5mm, 0.8mm. The pressure of vacuum the range of 10^-4-10^-5torr. The diameter of a plane made of the stainless steel is150mm. As a result of the experiment, the breakdown voltage is increased about electrode gap distance increased. The electrode material influenced breakdown voltage in vacuum.

  • PDF

Effect of rotational motion of piston ring on the oil consumption -2'nd report: Relationship between phase angle of ring end gap and oil consumption (피스톤링의 회전운동이 오일소모에 미치는 영향-제2보: 링갭의 위상각과 오일소모와 의 관계-)

  • 민병순;김중수;오대윤;최재권;진준하
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.5
    • /
    • pp.81-88
    • /
    • 1999
  • In order to understand the relationship between the phase angle of piston ring and oil consumption was measured by analyzing $CO_2$concentration in exhaust gas. The use of hydrogen fuel not gasoline makes this possible because all of the carbon component in exhaust gas can be assumed to be produced from oil. As a result of experiment, it is known that the oil consumption varies periodically and a specific location of ring end gap was found at each peak of oil consumption. Therefore, it was found that the oil consumption was not constant even at the same operating conditions and this is because the relative locations of top and 2'nd ring end gap change arbitrarily.

  • PDF

Effect of Discharge Gas on the Electrical Characteristics of the Glow Discharge Plasma for the Gas Chromatographic Detector (글로우방전 가스크로마토그라프 검출기에서 방전가스의 영향)

  • 박현미;강종성;김효진
    • YAKHAK HOEJI
    • /
    • v.39 no.5
    • /
    • pp.480-486
    • /
    • 1995
  • The change in discharge current of a glow discharge has been shown the potential sensitive detector for gas chromatography. To investigate the effect of carrier gas on the electrical characteristics of the discharge and the peak response, the discharge pressure, gas flow rate, and discharge gap have been studied. The discharge gas included the Ar, He, and N$_{2}$. The gas flow rate has been found one of the important parameters to affect both the electrical characteristics and the peak response.

  • PDF