• 제목/요약/키워드: Gantry angle

검색결과 68건 처리시간 0.028초

하악골 전산화단층사진촬영시 기준선에 관한 연구 (Reference line for computed tomogram of the mandible)

  • 유충현;김재덕
    • Imaging Science in Dentistry
    • /
    • 제32권3호
    • /
    • pp.153-157
    • /
    • 2002
  • Purpose : This study was performed to determine the proper reference line for taking axial computed tomograms from which the good cross-sectional views can be reformatted by multiplanar reconstruction. Methods : Three dry mandibles with implanted gutta percha cones in the extracted socket were scanned axially according to 6 reference lines of 2 mandibular positions with computed tomogram Hitachi W550. The accuracy of measurements of the lengths of implanted gutta perch a cones in the each cross-sectional view reformatted from axial computed tomogram by multiplanar reconstruction was evaluated. Results: The difference between the measurements and the real length of implant was smallest in the bucco-lingual views reformatted from the axial views scanned according to the reference line of group V-a. The smaller the angle difference between reference line and occlusal line was, the smaller the difference between the measurements in the bucco-lingual views reformatted from axial views and the real length of implant. The majority of measured widths of implants in the bucco-lingually reformatted views were larger than the actual values. Conclusions : When the mandible is inclined within the limitation of gantry angle and scanned with the reference line coincident with occlusal plane, the bucco-lingual view can be reformatted without deformation of images from the axially scanned images.

  • PDF

In Vivo Three-dimensional Motion Analysis of the Shoulder Joint During Internal and External Rotation at 90 Degrees of Abduction, using wide Gantry MRI.

  • Koishi, Hayato;Goto, Akira;Yoshikawa, Hideki;Sugamoto, Kazuomi
    • 대한견주관절학회:학술대회논문집
    • /
    • 대한견주관절학회 2009년도 제17차 학술대회
    • /
    • pp.175-175
    • /
    • 2009
  • Despite its importance for the understanding of joint kinematics in vivo, there has been few studies about shoulder joints. The purpose of this study is to analyze the glenohumeral joint during internal and external rotation at 90 degrees of abduction using in vivo noninvasive motion analysis system. MRI was performed for the following seven positions from maximum internal rotation to maximum external rotation at intervals of 30 degrees. We used 3D-gradient echo sequencing (TR: 12 ms, TE: 5.8 ms, 0.8 mm-slice thickness). Our method is based on matching three-dimensional MR images by the similarity of the image intensity. We analyzed the in vivo three-dimensional motions of the glenohumeral and scapulothoracic joint during this motion. In scapla plane, the mean rotation angle of the glenohumeral join was 105.5 degrees ($SD{\pm}39.0^{\circ}$). The mean rotation angle of the scapulothracic joint was 27.5 degrees ($SD\;{\pm}\;7.7^{\circ}$). The contribution ratio is almost 3.8:1 of glenohumeral and scapulothracic joint respectively.

  • PDF

영상유도 양성자치료를 위한 콘빔 CT 재구성 알고리즘: 기하학적 보정방법에 관한 연구 (Geometric Calibration of Cone-beam CT System for Image Guided Proton Therapy)

  • 김진성;조민국;조영빈;윤한빈;김호경;윤명근;신동호;이세병;이레나;박성용;조관호
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.209-218
    • /
    • 2008
  • IMRT, 양성자 치료와 같이 방사선 치료 기술이 발전할수록 치료 시 환자의 위치를 확인하고 그 정확성을 평가하는 기술의 중요성이 강조되고 있다. 현재 국립암센터 양성자치료센터에 설치되어 있는 양성자 치료기의 단순 X-선 영상시스템을 이용하여 콘빔 CT (cone-beam CT) 3차원 영상을 획득, 영상유도 방사선 치료의 가능성을 확인하고자 하였다. 양성자 치료기에 설치되어있는 X-선 영상시스템(SDD: 2,108 mm, SOD: 1,511 mm, Varian a277 x-ray tube & Varian Paxscan 4030: a-Si+DRZ screen)을 이용하여 양성자 갠트리를 $2^{\circ}$씩 회전시켜가면서 기하학적인 오차 측정을 위한 팬톰과 인체 팬톰 (Humanoid phantom, Rando, CA, USA)의 투사영상을 획득하였다. 현재 시스템적으로 연속적인 회전과 영상획득이 지원되지 않아서 영상획득 후 갠트리를 회전하는 방법으로 투사영상을 획득하였다. 기하학적 오차측정을 위한 팬텀과 두경부 팬텀에 대해서 $360^{\circ}$를 회전하며 180장의 투사영상($2,304{\times}3,200$, 14 bit with 127${\mu}m$ pixel pitch)을 관전압 85 kVp, 관전류 80 mA, 조사시간 0.5 s의 조건으로 촬영하였다. 콘빔 CT 영상재구성을 위해 Ram-Lak filter를 적용한 Feldkamp cone-beam 알고리즘을 사용하였으며, 획득한 180장의 투사영상을 사용하여 $0.4{\times}0.4{\times}0.4mm^3$의 voxel size를 가진 $512{\times}512{\times}512$ CT영상을 재구성하였다. 기하학적인 오차 측정방법을 통해 X-선 선원, 검출기와 갠트리의 기하학적 정보를 측정하였다. 측정된 결과에 의하면 검출기가 $0.25^{\circ}$ 회전된 오차를 보이는 것을 발견하였다. 기하학적 교정으로 재구성된 콘빔 CT 영상을 multi-planar view (axial, sagittal and coronal view) 및 3차원 영상으로 재구성하여 비교 평가 하였다. 현재 양성자치료기에 설치되어있는 단순 X-선 영상 시스템에서 기하학적 오차 측정을 위한 볼 팬텀을 이용하여 시스템의 오차를 측정하였다. 측정한 오차를 바탕으로 기하학적 교정을 통해서 두경부 및 복부 팬텀에 대한 3차원 영상인 콘빔 CT 영상들을 재구성하였다. 추후 연속적인 회전을 통한 영상획득이 가능하게 된다면, 보다 정확하고 신속한 영상재구성이 가능 하며 콘빔 CT가 영상유도 양성자 치료에 매우 유용할 것으로 사려된다.

  • PDF

Customer Acceptance Procedure for Clinac (21EX-Platinum)

  • 홍동기;이우석;권경태;박광호;김정만
    • 대한방사선치료학회지
    • /
    • 제16권2호
    • /
    • pp.43-61
    • /
    • 2004
  • 목적 : 환자의 치료에 있어서 정확한 장비의 설치와 성능 평가는 치료의 질을 향상시키는데 중요한 요소라고 할 수 있으며 사용자가 장비의 특성과 사용 방법을 숙달하고 업무를 수행하는 것이 매우 중요하다고 생각한다. 그러므로 방사선 치료기를 설치하고 방사선 치료를 하기 전에 사용자가 직접 장비의 설치와 성능 평가에 참여하고 특성을 파악하여 이해하는 것이 필요하다. 본 연구에서는 CAP의 과정과 성능 평가결과를 소개하고자 한다. 대상 및 방법 : 선형가속기 21EX(varian, USA)를 대상으로 설치 시부터 성능 검사까지 전 과정을 평가하였고 성능평가는 크게 radiation survey, mechanical test, radiation isocenter test, beam performance, dosimetry, enhanced dynamic wedge로 구분하여 X-omat film(kodark), 선량 측정 장비(multidata, densitometer, electrometa)를 이용하여 실시하였다. 또한 선형가속기에 부착된 MLC(millenium, 120leaf)와 EPID(portal vision)의 성능 평가는 별도로 실시하였다. 결과 : Survey meter를 이용하여 측정한 leakage는 허용 범위 이하의 선량이 검출되었고 mechanical test에서 collimator, gantey, couch rotation은 1mm 이하였고 육안으로 평가한 angle은 digital이 ${\pm}1^{\circ}$이내에 mechanical은 ${\pm}5^{\circ}$이내였다. 또한 light field와 cross-hair의 직선성 검사도 1mm이내로 평가되었다. (A)symmetrical jaw field는 upper/lower 모두 ${\pm}0.5mm$이내였다. X-omat film을 이용한 radiation isocenter test는 1mm 이하였고 light field와 radiation field 의 일치성 검사는 ${\pm}1mm$ 이내였으며 선량 측정 장비를 이용하여 측정한 $\%DD$는 photon energy는 모두 ${\pm}1\%$ 이내로 electron energy는 $90\%,\;80\%,\;50\%,\;30\%$를 측정한 결과 허용 범위 내에서 평가되었다. photon 과 electron energy의 flateness는 각각 $2.3\%$(기준 $3\%$)이내, $3\%$(기준 $4.5\%$)이내이고 symmetry는 $0.45\%$(기준 $2\%$), $0.3\%$(기준 $2\%$)이내에서 평가 할 수 있었다. 그리고 dosimetry test는 sort term, MU setting, rep rate, dose rate accuracy를 photon과 electron energy 별로 MU와 gantry angle을 바꿔가면서 측정한 결과 허용범위 오차이내에 포함되는 것을 확인 할 수 있었다. EPID(portal vision)의 Exact-Arm의 기계적인 검사는 vertical, lateral, longitudinal은 허용범위 내에서 동작했으며 명암과 해상도 검사도 05.mm의 니크롬선이 선명하게 나타났으며 phantom의 음영도 뚜렷하게 나타났다. Multileaf collimator(MLC)검사는 leaf이 isocenter의 중심에 정확하게 배열되었으며 재현성 검사도 정상적으로 동작하였다. 결론 : Clinac 21EX 장치의 customer acceptance를 통해서 향후의 환자의 치료를 하는데 있어 장치의 안정성을 확인 할 수 있었으며 치료 전의 선형가속기와 주변장치의 특성을 파악 할 수 있어서 장비 사용에 있어서 어려움을 감소시킬 수 있으리라고 생각된다. 또한 사용자가 적극적으로 참여함으로써 앞으로 환자를 치료하는데 있어서도 많은 도움이 되리라 생각한다.

  • PDF

입체적횡다증회전조사를 병합한 방사선수술의 새로운 접근 : 포톤나이프 (A New Approach with Combined Stereotactic Trans-multiarc Beams for Radiosurgery Based on the Linear Accelerator : Photon Knife)

  • 최태진;김진희;김옥배
    • Radiation Oncology Journal
    • /
    • 제14권2호
    • /
    • pp.149-158
    • /
    • 1996
  • 목적 : 선형가속기의 광자선을 이용한 두개내 소병변의 방사선수술에서 다중회전조사와 횡다중회전조사를 병용한 방사선 수술방법을 개발하고, 컴퓨터단층영상을 재구성한 방사선수술계획을 통해 선량분포를 비교하여 병변이외 정상조직의 선량을 줄이기 위한 선량변수를 구하였다. 대상 및 방법 : 선형가속기 6 MV 광자선을 이용하여 치료대 각과 선원지지체 회전 및 환자체위변위를 이용한 입체적 다중 및 횡다중회전조사를 조사하여 선량분포를 비교하였다. 입체적 선량분포와 횡단면, 시상면 및 관상면 치료대 영상재구성의 선량분포는 본 대학에서 개발한 방사선수술기구 및 소프트웨어 (Photon Knife)를 통해 이루어졌다. 입체적 다중회전조사에 의해 얻은 선량은 치료대 각이 20, 50, 120, 160 도, 각각의 선원지지체 회전각은 20-160도이며, 다중회전조사의 치료대각 30, 150도와 횡다중회전조사의 치료대각 30, 150도에 선원 회전각 20-160도를 입체조사하여 비교하였다. 결과 : 선형가속기를 이용한 방사선수술선량분포는 동일 콜리메이터에서도 치료대와 선원지지체 각에 따라 크게 변하였다. 입체횡다중회전조사를 시행한 경우 표적을 중심으로 전후방향의 선량분포는 다중회전조사만을 사용한 경우보다 선량기울기가 증가하여 정상뇌조직의 손상을 더 감소시킬 수 있음을 알 수 있었으며, 병변주위의 치명장기 위치에 따라 방사선 회전 방향을 적절히 정할 수 있다. 방사선수술의 입체선량과 주위 장기 및 표적의 On-Target 입체화는 방사선수술의 정확성, 복수개의 표적중심결정과 주위정상장기의 선량포함범위를 비교적 정확하게 보여줌을 알 수 있다. 결론 : 방사선수술선량계획의 입체화는 선량과 표적 및 주위장기의 선량범위를 입체적으로 정할 뿐만 아니라, 표적의 모양이 불규칙형일 때는 복수개의 표적중심결정에 필수적임을 알 수 있었다. 다중회전조사와 횡다중회전조사를 병합한 방사선수술은 표적주위의 치명정상장기의 손상을 줄이기 위해 총회전각의 변화없이 치명장기에 도달될 선량을 줄일 수 있으며, 25 mm 직경의 콜리메이터를 사용한 선량분포는 $80-50\%$의 간격이 $1.1\~3.0 mm$, $90\~50\%$$2.0\~3.0mm$를 나타내었다.

  • PDF

LCD 대평판 고정밀 얼라인먼트를 위한 비전 시스템 연구 (A Study on Vision System for High Precision Alignment of Large LCD Flat Panel Display)

  • 조성만;송춘삼;김준현;김종형
    • 제어로봇시스템학회논문지
    • /
    • 제15권9호
    • /
    • pp.909-915
    • /
    • 2009
  • This work is to develop a vision system for high precision alignment between upper and lower plates required at the imprinting process of the large LCD flat panel. We compose a gantry-stage that has highly repeated accuracy for high precision alignment and achieves analysis about thermal transformations of stage itself. Position error in the stage is corrected by feedback control from the analysis. This system can confirm alignment mark of upper and lower plates by using two cameras at a time for the alignment of two plates. Pattern matching that uses geometric feature is proposed to consider the recognition problem for alignment mark of two plates. It is algorithm to correct central point and angle for the alignment from the recognized mark of upper and lower plates based on the special characteristics. At the alignment process, revision for error position is performed through Look and Move techniques.

토모테라피에서 쌀 볼루스 팬텀의 유용성 평가: 팬텀연구 (Evaluating the Usefulness of Rice Bolus Phantom in Tomotherapy: Phantom Study)

  • 김대건;정재홍
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권6호
    • /
    • pp.663-669
    • /
    • 2021
  • The purpose of this study was to evaluate the usefulness of the rice bolus for upper-lower extremity radiation therapy by Tomotherapy. The computed tomography images were obtained for air, water, and rice bolus. The average and standard deviation of the Hounsfield unit (HU) were measured for image evaluation. The conformity index (CI) and homogeneity index (HI) were calculated for dose distribution of the planning target volume (PTV) which was treated by direct mode with gantry angle (90 and 270 angle). The point dose of a total of ten axial planes was measured to confirm the different regions. The mean of HU was -999.72 ± 0.72 at the air. The water and rice bolus were -0.13 ± 1.65 and -170 ± 27.2, respectively. The CI (HI) of PTV was 0.96 (1.36) at the air. 0.95 (1.04) at the water bolus, and 0.95 (1.04) at the rice bolus. The maximum dose for air was 136 cGy which is about 32% higher than 103 cGy for water and 104 cGy for rice bolus. There was a statistical difference for point dose between air and water including rice bolus (p=0.04), however, no statistical difference between water and rice bolus (p=0.579).The rice bolus phantom for extremities radiation therapy could be not only the optimized dose distribution but also the convenience and equipment safety at Tomotherapy. However, additional research will be necessary to more accurately verify the clinical usefulness of rice bolus phantom due to not enough examination.

측정과 ADAC 치료계획 시스템에서 계산된 고에너지 전자선의 Monitor Unit Value 비교 (Comparison of Monitor Units Obtained from Measurements and ADAC Planning System for High Energy Electrons)

  • Lee, Re-Na;Choi, Jin-Ho;Suh, Hyun-Suk
    • 한국의학물리학회지:의학물리
    • /
    • 제13권4호
    • /
    • pp.202-208
    • /
    • 2002
  • 본 논문에서는 표면조직에 있는 종양 치료 시 사용되고 있는 고에너지 전자선의 monitor unit을 다양한 방법에 의해 계산하여 평가 하고자 한다. 본 병원에서 6, 9, 그리고 12 MeV 전자선으로 치료한 33명의 유방암 환자가 선택되었다. 각 환자마다 모의 치료기에서 얻어진 시뮬레이션 필름에 불규칙한 모양의 전자선 블록이 제작되었다. 이러한 불규칙한 모양의 블록을 이용하여 최대선량 깊이에 100 cGy의 선량을 주기 위해 필요한 monitor unit 이 3차원 치료계획 시스템 (Pinnacle 6.0, ADAC Lab)을 사용하여 계산되었고 측정되었다. 선원과 표면 거리(SSD)가 100 cm 인 곳에서 plane parallel (PP) 이온전리함(Roos, OTW Germany) 을 사용하여 고체 물 팬텀 내에서 측정하였다. 불균등 조직에 대한 효과를 평가하기 위해 CT 데이터를 사용하였고 monitor unit을 균등조직 및 비균등조직 내에서 계산하였다. 균등조직으로 계산하기 위해 CT의 밀도를 1 g/㎤로 지정하였다. 이러한 방법에 의해 구해진 monitor unit 값들을 비교하였다. 한 지점에서 측정된 선량과 RTP에서 구해진 선량을 비교 할 때 측정된 값이 치료계획에 의해 계산된 값보다 조금 높았다. 평평한 고체 물 표면에 조사된 경우 측정된 값과 계산된 값에는 6 MeV 전자선의 경우 4%, 그리고 9 및 12 MeC 전자선의 경우 2%의 차이가 있었다. 또한 다양한 조사방향에서 CT 데이터를 사용하여 monitor unit을 계산한 경우 불균등한 조직의 밀도를 고려하여 계산된 값과 고려하지 않고 계산된 값은 모든 에너지에서 3% 이내의 차이가 있었다. 이러한 결과는 전자선을 사용하여 유방암 치료 시 조직내의 불균등한 밀도를 고려하지 않고 monitor unit을 계산해도 큰 차이가 발생하지 않는다는 것을 의미한다.

  • PDF

CT 시뮬레이터의 기하학적 성능평가용 팬톰 (A CT Simulator Phantom for Geometrica1 Test)

  • 민철기;이병용;안승도;최은경;장혜숙
    • Radiation Oncology Journal
    • /
    • 제18권4호
    • /
    • pp.337-344
    • /
    • 2000
  • 목적 : 가상 시뮬레이션 기능을 갖는 CT 시뮬레이터의 기하학적인 성능평가를 위한 팬톰을 고안하여 제작하고, 그 팬톰의 성능을 보고하고자 한다. 대상 및 방법: .팬톰은 PMMA 재질로 직경 20 cm, 길이 24 cm인 원통과 25$\times25\times$31 cm$^{3}$인 직육면체가 합쳐진 모양으로 고안하였다. 원통의 겉표면에는 영상결손이 극소화되면서 CT 상에서 잘 구별이 되는 직경이 0.8 mm인 선을 4개의 나선모양으로 부착하였다. 직육면체는 4개의 24$\times24\times$0.5 cm3인 정사각형의 판으로 구성되어 있으며, 각판 위에는 24$\times$24 cm$^{2}$, 12$\times$12 cm$^{2}$, 6$\times$6 cm$^{2}$의 사각형 모양을 갖도록 선을 붙였다. 각각의 정사각형은 원통방향에 대해 0$^{\circ}$ , 15$^{\circ}$ , 30$^{\circ}$가 되도록 배치하였다. 직육면체의 부분에서는 조사면 및 치료 테이블의 각도, 콜리메이터 각도, 동중심점의 이동, SSD를 측정을 할 수 있으며, 원통형 부분에서는 갠트리 각도의 정확성을 평가하도록 고안하였다. 가상 시뮬레이션 소프트웨어를 통해 다양한 조건의 가상적인 시뮬레이션을 수행하였으며 가상 시뮬레이션의 결과를 이용하여 CT 시뮬레이터의 기하학적인 QC/QA를 수행하였다 결과 : 팬톰의 한 부분인 직육면체 스캔을 통해 얻은 DRR에서 구현된 각 24 cm 조사면의 크기에서 1 mm 이내의차이, 동중심점 이동에서는 0.5$\~$1 mm 차이가 있었음을 알 수 있었다. 콜리메이터 회전과 치료대 회전에서는 각각 0.5$\~$l$^{\circ}$ 의 차이가 있었고, 갠트리 회전에 있어서는 0.5$\~$1$^{\circ}$ 오차가 있었다. 슬라이스 간격이 10 mm 조건이 2$\~$5 mm 조건보다 영상구분의 어려운 점은 있었으나 결과는 유의할만한 차이가 없었다. 결론 : 자체 제작한 팬톰을 가지고 가상적인 모의 시뮬레이션을 했을 때 최대 2 mm와 1$^{\circ}$ 이내의 오차가 있었고 또한 스캔의 조건에 따라 오차가 변할 수 있다는 것을 알 수 있었다. 시뮬레이터에서 DRR을 구현했을 때 각각의 치료 조건들에 대해 오차가 임상적용 범위 안에 있어서 이 팬톰을 이용하여 주기적인 QC/QA에 사용할 수 있음을 보였다.

  • PDF

척추 전방전위증의 전산화 단층촬영 소견 : 협부형과 퇴행형의 비교 (CT Study of Spondylolisthesis Comparison Between Isthmic and Degenerative Type)

  • 이종덕;변재영
    • Journal of Acupuncture Research
    • /
    • 제17권4호
    • /
    • pp.79-87
    • /
    • 2000
  • Objectives : To evaluate the findings useful for differential diagnosis and associated abnormaiities of isthmic spondylolisthesis and degenerative spondylolisthesis on CT. Materials and methods : We reviewed retrospectively the CT images of 65 patients who were diagnosed spondylolisthesis during 3 years period. Our technique was 5mm slices at 5mm intervals with gantry angle to parallel the interspaces. Also reformatted sagittal views were taken. 41 patients were isthmic spondylolisthesis and 24 patients were degenerative spondylolisthesis. Resuits : Isthmic spondylolisthesis. 1. Isthmic type was more common at L5-S1. 2. The degree of anterior displacement was grade I and II. 3. The plane of defect was more horizontal than the usual facet joint. 4. The defect had an irregular shape. 5. Medial aspect of bone just anterior to defect had a small round prominence. 6. Anteroposterior elongation of the spinal canal was common. 7. Pseudobulging disk was common. 8. The most common associated abnormality was a HNP at the upper level of the defect. Degenerative spondylolisthesis. 1. Degenerative type was more common at L4-5. 2. The degree of anterior disptacement was grade I and II. 3. The Plane of facet joint was oriented obliquely instead of horizontally. 4. The posterior facet(inferior facet of superior vertebra) was anteriorly displaced. 5. Bony spur of the posterior portion of anterior facet was seen. 6. The facet joints often contain gas(vaccum phenomenum). 7. The most common associated abnormality was a HNP at the level of the displacement. Conclusions : CT is a highly accurate and most sensitive technique for recognition, differential diagnosis of isthmic and degenerative types and the detection of associated abnormalities.

  • PDF