• Title/Summary/Keyword: Gamma source

Search Result 670, Processing Time 0.024 seconds

Manufacture of a Gamma-ray Source using the Neutron Activation and Determination of a HPGe Detector Efficiency (중성자 방사화법을 이용한 감마선원 제조 및 HPGe 검출기 효율 결정)

  • Seo, Bum-Kyoung;Lee, Kil-Yong;Yoon, Yoon-Yeol;Lee, Kune-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.1
    • /
    • pp.17-23
    • /
    • 2004
  • In order to save time and money needed in the purchase commonly used gamma-ray standard sources, a new radioactive standard source was manufactured by the neutron activation of some regent in the research reactor HANARO. The source was manufactured with an aqueous solution by mixing and dissolving the irradiated reagents. The manufactured source was compared with a commercial standard source. It was confirmed that it could be used as an efficiency calibration source. Also, in order to compare the variation of efficiency due to the volume difference for various containers used in radioactivity assay, the efficiency variation as a function of sample volume was investigated.

Effects of poly-$\gamma$-glutamic acid on serum and brain concentrations of glutamate and GABA in diet-induced obese rats

  • Lee, Hye-Sung;Chang, Moon-Jeong;Kim, Sun-Hee
    • Nutrition Research and Practice
    • /
    • v.4 no.1
    • /
    • pp.23-29
    • /
    • 2010
  • Poly-gamma-glutamic acid ($\gamma$-PGA) is a mucilaginous and biodegradable compound produced by Bacillus subtilis from fermented soybeans, and is found in the traditional Korean soy product, cheongkukjang. This study was carried out to evaluate the effects of $\gamma$-PGA from a food source on the concentration of the neurotransmitter GABA and its metabolic precursor glutamate in diet-induced obese rats. Eight-week old male Sprague-Dawley rats (n=60) were used. The rats were divided into two groups and obesity was induced by providing either a 10% control fat or 45% high fat diet for 5 weeks. The rats were then blocked into 6 groups and supplemented with a 0.1% $\gamma$-PGA diet for 4 weeks. After sacrifice, brain and serum GABA and glutamate concentrations were analyzed by high performance liquid chromatography with fluorometric detection. The rats fed the high fat diet had significantly increased body weights. $\gamma$-PGA supplementation significantly increased serum concentrations of glutamate and GABA in the control fat diet groups while this effect was not found in the high fat groups. In the brain, glutamate concentrations were significantly higher in the $\gamma$-PGA supplemented groups both in rats fed the normal and high fat diets than in the no $\gamma$-PGA controls. GABA concentrations showed the same tendency. The results indicated that $\gamma$-PGA intake increased GABA concentrations in the serum and brain. However, the effects were not shown in obese rats.

A Study on the Self-absorption Correction Method of HPGe Gamma Spectrocopy Analysis System Using Check Source (Check Source를 이용한 HPGe감마핵종분석시스템의 자체흡수 보정방법 연구)

  • Jeong-Soo, Park;Hyo-Jin, Lim;Hyun-Soo, Seo;Da-bin, Jang;Myoung-Joon, Kim;Sang-Bok, Lee;Sung-Min, Ahn
    • Journal of radiological science and technology
    • /
    • v.45 no.6
    • /
    • pp.523-529
    • /
    • 2022
  • Gamma spectroscopy analysis is widely used for radioactivity analysis, and various factors are required for radioactivity calculations. Among the factors, K3 for each sample significantly influences the results. The previous methods of correcting the self-absorption effect include a computational simulation method and a method that requires making a CRM(certified reference material) identical to the sample medium. However, the above methods have limitations when used in small institutions because they require specialized program utilization skills or high manufacturing costs and large facilities. The aim of this study is to develop a method that can be easily and rapidly applied to radioactivity analysis. After filling the beaker with water, we placed the radiation source in a uniform position and used the measured value as the benchmark. Next, a correction factor was derived based on the difference in the radiation source count of the benchmark and the identically measured sample. For the radiation source, Eu-152, which emits a broad range of energy within the measurement range of gamma rays, and Cs-134 and Cs-137, which are indicator nuclides in environmental radiation analysis, were used. The sample was selected within the density range of 0.26-2.11 g/cm3, and the correction factor was derived by calculating the count difference of each sample compared to the reference value of water. This study presents a faster and more convenient method than the existing research methods for determining the self-absorption effect correction, which has become increasingly necessary.

Sensing changes in tumor during boron neutron capture therapy using PET with a collimator: Simulation study

  • Yang, Hye Jeong;Yoon, Do-Kun;Suh, Tae Suk
    • Nuclear Engineering and Technology
    • /
    • v.52 no.9
    • /
    • pp.2072-2077
    • /
    • 2020
  • The purpose of this study was to demonstrate the feasibility of sensing changes in a tumor during boron neutron capture therapy (BNCT) using a Monte Carlo simulation tool. In the simulation, an epi-thermal neutron source and a water phantom including boron uptake regions (BURs) were simulated. Moreover, this simulation also included a detector for positron emission tomography (PET) scanning and an adaptively-designed collimator (ADC) for PET. After the PET scanning of the water phantom, including the 511 keV source in the BUR, the ADC was positioned in the PET's gantry. Single prompt gamma rays were collected through the ADC during neutron irradiation. Then, single prompt gamma ray-based tomography images of different sized tumors were acquired by a four-step process. Both the signal-to-noise ratio (SNR) and tumor size were analyzed from each step image. From this analysis, we identified a decreasing trend of both the SNR and signal intensity as the tumor size decreased, which was confirmed in all images. In conclusion, we confirmed the feasibility of sensing changes in a tumor during BNCT using PET and an ADC through Monte Carlo simulation.

Collimator Design and Manufacture for $M{\ddot{o}}ssbauer$ Source ($M{\ddot{o}}ssbauer$ 선원용 콜리메이터 설계 및 제작)

  • Park, Sung-Ho;Kim, Jong-Kyung
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.183-187
    • /
    • 2003
  • Collimator for $M{\ddot{o}}ssbauer$ source was manufactured for compton scattering experiment. Exposure dose rate was calculated and measured using GM counter for radiation evaluation. These results were well agreed to each other and used for collimator design. SUS303 was used for collimator material because exposure dose rate at 10 cm is about 2 mR/h. The radiation emited from the 35 mm, 65 mm hole was measured using gamma camera which have 4' diameter. 2-D radiation image was acquired and analyzed. The radiation size at Gamma Camera was 8.0 mm and 5.8 mm respectively.

Thermal Transitions of the Drawn Film of a Nylon 6/Layered Silicate Nanocomposite

  • Park Soo-Young;Cho Yang-Hwan
    • Macromolecular Research
    • /
    • v.13 no.2
    • /
    • pp.156-161
    • /
    • 2005
  • The thermal transitions of a nylon 6/layered silicate nanocomposite were studied by differential scanning calorimetry and in-situ synchrotron X-ray diffraction. The drawn film of the nylon 6/layered silicate nanocomposite typically showed three endotherms in the DSC thermogram; a very broad endotherm at $\sim120^{\circ}C(T_{1})$, a double-melting endotherm at $\sim215^{\circ}C(T_{2})$, and a high temperature endotherm at $\sim240^{\circ}C(T_{3})$. The drawn film of the nylon 6/ layered silicate nanocomposite was comprised of a mixture of the $\alpha and \gamma$ forms, with $the \alpha form$ being generated by drawing the pressed film having $the \gamma form$. The melting and crystallization of the crystals were observed at the above thermal transitions during the heating experiment performed at the Pohang X-ray synchrotron radiation source (4C2). The newly generated form was meta-stable and melted $at {\sim}T_{1}$. The double-melting $at {\sim}T_{2}$ was due to the exothermic crystallization of $the \alpha form$ during the main endothermic melting of $the \gamma form$. $The \alpha form$ crystallized $at {\sim}T_{2}$ and melted $at {\sim}T_{3}$.

Investigation of acrylic/boric acid composite gel for neutron attenuation

  • Ramadan, Wageeh;Sakr, Khaled;Sayed, Magda;Maziad, Nabila;El-Faramawy, Nabil
    • Nuclear Engineering and Technology
    • /
    • v.52 no.11
    • /
    • pp.2607-2612
    • /
    • 2020
  • The present work was aimed to show the possibility of using hydrogel (acrylic/boric acid) for evaluation of the neutron radiation shielding. The influence of acrylic acid concentration, different gamma doses and relative contents of boric acid were studied. The physical properties and the thermomechanical stability of the studied samples were investigated. The shielding property of the composite for neutron was tested by Pu-Be neutron source (5 Ci) under room temperature. The neutron fluence rates and gamma fluxes were measured using a stilbene organic scintillator. The macroscopic effective removal cross-section ΣR (cm-1) of fast neutrons and total attenuation coefficient μ (cm-1) of gamma rays has been studied experimentally. The transmission parameters, the relaxation length (??) and the half-value layer (HVL) were obtained. The obtained results indicated that the addition of boric acid to acrylic acid tends to increase the macroscopic effective removal cross-section ΣR (cm-1) to 0.141 compared to 0.094 of ordinary concrete.

MOGABA: Monitoring of Gamma-ray Bright AGN with KVN 21-m radio telescopes at 22, 43 and 86GHz

  • Lee, Sang-Sung;Byun, Do-Young;Baek, Junhyu;Han, Myounghee;Yang, Jihae;Sohn, Bong Won
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.239.2-239.2
    • /
    • 2012
  • We report preliminary results of MOGABA project for monitoring total flux density, linearly polarized flux, and polarization angle at 22, 43 and 86GHz of Gamma-ray bright AGN (Active Galactic Nuclei) with KVN (Korean VLBI Network) 21-m radio telescopes. The project has been conducted in one year since May 2011 with an effective monitoring cycle of 1 week, observing four main objects (3C 454.3, BL Lac, 3C 273, and 3C 279). More objects were included in the source list when they had flared in Gamma-ray. Especially, we included a compact radio source at the Galactic center, SgrA* since Jan. 2012. In this paper, we report the current status of the project and preliminary results for the monitoring observations.

  • PDF

Analysis of Gamma Radiation Fields in the MAPLE-X10 Facility Associated with Loss-of-Pool-Water Accident Conditions (LOSS-OF-POOL-WATER 사고시 연구용 원자로 MAPLE-X10 시설에서의 감마 방사선장 해석)

  • Kim, Kyo-Youn;Ha, Chung-Woo;I.C. Gauld
    • Nuclear Engineering and Technology
    • /
    • v.21 no.2
    • /
    • pp.63-72
    • /
    • 1989
  • An analysis for the gamma radiation fields in the research reactor MAPLE-X10 facility has been peformed under the assumption of partial loss of reactor and service pool water to assess the safety from the view point of design. Four photon source terms considered in the analysis were calculated using the ORIGEN-S code. Gamma dose rate calculations over the reactor and service pools during the water-loss accident conditions were performed using QAD-CG code. MCNP code (Monte Carlo Neuron and Photon Transport code), also, was used to assess the scattered radiation fields away from the pools, which is appropriate for calculating the scattered photon dose rates outside of the solid angle subtended by the source and pool walls.

  • PDF

Proposing a gamma radiation based intelligent system for simultaneous analyzing and detecting type and amount of petroleum by-products

  • Roshani, Mohammadmehdi;Phan, Giang;Faraj, Rezhna Hassan;Phan, Nhut-Huan;Roshani, Gholam Hossein;Nazemi, Behrooz;Corniani, Enrico;Nazemi, Ehsan
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1277-1283
    • /
    • 2021
  • It is important for operators of poly-pipelines in petroleum industry to continuously monitor characteristics of transferred fluid such as its type and amount. To achieve this aim, in this study a dual energy gamma attenuation technique in combination with artificial neural network (ANN) is proposed to simultaneously determine type and amount of four different petroleum by-products. The detection system is composed of a dual energy gamma source, including americium-241 and barium-133 radioisotopes, and one 2.54 cm × 2.54 cm sodium iodide detector for recording the transmitted photons. Two signals recorded in transmission detector, namely the counts under photo peak of Americium-241 with energy of 59.5 keV and the counts under photo peak of Barium-133 with energy of 356 keV, were applied to the ANN as the two inputs and volume percentages of petroleum by-products were assigned as the outputs.