• Title/Summary/Keyword: Gamma evaluation

Search Result 704, Processing Time 0.032 seconds

Evaluation of DNA Damage and Repair Kinetics in the Earthworm (Eisenia fetida) Exposed to Radiation and Mercury (방사선과 수은에 의해 유도된 Eisenia fetida 체강세포의 DNA 손상 및 수복 평가)

  • Ryu, Tae-Ho;Nili, Mohammad;An, Kwang-Guk;Kim, Jin-Kyu
    • Korean Journal of Environmental Biology
    • /
    • v.29 no.1
    • /
    • pp.68-73
    • /
    • 2011
  • The single cell gel electrophoresis (SCGE) assay is a microelectrophoretic technique for assessments of DNA damage at the level of the individual eukaryotic cell. The SCGE assay, due to its simplicity, sensitivity and need of a few cells, has advantages compared to other genomic damage assays such as sister chromatid exchange, chromosomal aberration and micronucleus test. In this study, investigated were the levels of DNA damage and the repair kinetics in the coelomocytes of Eisenia fetida treated with HgCl2 and ionizing radiation by means of the SCGE assay. For detecting DNA damage and repair in coelomocytes, earthworms (E. fetida) were irradiated with six doses of ${\gamma}$-rays (0, 2.5, 5, 10, 20 and 50 Gy) and in vivo exposed to mercuric chloride at 0, 80 and 160 mg $kg^{-1}$ for 48 hours. Then the Olive tail moments were measured during 0~12 hours after irradiation and 0~72 hours after Hg treatment. The results showed that the more the oxidative stress was induced by mercury and radiation, the longer the repair time was required. Also, the results suggest that the SCGE assay may be used as an important tool for comparison of the sensitivity of different species to oxidative stresses.

Evaluation of Artificial Radionuclides in Berries (장과류의 방사능 안전성 평가)

  • Kim, Ji-eun;Kim, Dae-hwan;Lee, Sung-nam;Moon, Su-kyong;Park, Yong-bae;Yoon, Mi-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.1
    • /
    • pp.31-36
    • /
    • 2020
  • To ensure food safety of berries from radioactive contamination, radioactivity monitoring was conducted with a total 258 samples of the berries and processed berry products distributed in Gyeonggi-do, South Korea, from 2016 to 2018. The concentration of artificial radionuclides, 131I, 134Cs and 137Cs, was analyzed using gamma-ray spectrometry. 131I and 134Cs were not detected above the MDA (Minimum Detectable Activity) value from any of the samples. However, the range of radioactivity concentration of 137Cs was 0.69-808.90 Bq/kg in 39 cases of berries. 137Cs was detected at 0.70-3.29 Bq/kg from 6 cases of domestic berries, which were manufactured from imported raw materials. Among 33 cases of imported berries, 137Cs was detected at 0.69-808.90 Bq/kg. The concentrations of 137Cs in 1 case of blueberry powder product (808.90 Bq/kg) and 2 cases of lingonberry powder products (103.93, 188.46 Bq/kg) exceed domestic maximum radioactivity limits, and these were detected in the berries from Poland. These results suggest that monitoring system for imported berries and processed berry products should be continuously intensified to secure food safety.

THE EFFECT OF AUTOCLAVE STERILIZATION AND REUSE OF $SMARTPEG^{TM}$ ON THE IMPLANT STABILITY QUOTIENT (ISQ) MEASUREMENT ($Smartpeg^{TM}$의 고압멸균소독 및 재사용이 임플랜트 안정성 지수(ISQ) 측정에 미치는 영향)

  • Kang, In-Ho;Kim, Myung-Joo;Lim, Young-Jun;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.644-652
    • /
    • 2007
  • Statement of problem: Resonance frequency analysis is evaluated as the non-invasive and objective method for the evaluation of implant stability and has been increasingly used. It is necessary to evaluate the factors affect the ISQ measurement stability. Purpose: This study was performed to evaluate the effect of the autoclave sterilization and reuse of $Smartpeg^{TM}$ on ISQ measurement. Material and methods: $SmartPeg^{TM}$ (Integration Diagnostics Ltd., $G\ddot{o}teborg$, Sweden) of autoclave group (A) was autoclave sterilized 9 times and $Smartpeg^{TM}$ of reuse group (R) was reused 9 times. Ten $SmartPeg^{TM}s$ were allocated to each group and after each autoclave sterilization and reuse, implant stability quotient (ISQ) values were measured 3 times from the two directions a and b at a right angle. $Osstell^{TM}$ mentor (Integration Diagnostics Ltd. $G\ddot{o}teborg$, Sweden) was used and type 1 (article no. 100353) $Smartpeg^{TM}$ was selected according to $Smartpeg^{TM}$ reference list. Osstem Implant US II future (Osstem Co., Seoul, Korea) in $4.0mm{\times}11.5mm$ was embedded in the self-curing acrylic resin ($Orthojet^{(R)}$, Lang Dental, U.S.A.). Data was statistically analyzed by one-way ANOVA $({\alpha}=.05)$ and scheffe test was done where a significant difference exist. Correlation test was also done between ISQ value and the number of autoclave sterilization or reuse. Results: 1. In autoclave group, the means and sd. of ISQ value before autoclave sterilization were $84.97{\pm}0.41,\;84.93{\pm}0.74$ at direction a and b. There was significant differences between autoclave groups at direction a and b (P=.000). 2. In reuse group, the means and sd. of ISQ value before reuse were $85.40{\pm}0.62,\;85.50{\pm}0.57$ at direction a and b. There was no significant difference between reuse groups at direction a and b (P>.05). 3. There was a weak positive correlation between the number of reuse and ISQ value at direction a and b (${\gamma}=.207$ and .246, P<.01). Conclusion: Within the limitations of this study, the following conclusions were drawn. Till ninth reuse of $Smartpeg^{TM}$, the ISQ measurement stability did not be affected. After twice autoclave sterilization of $Smartpeg^{TM}$ the ISQ measurement stability was affected.

Microbiological and Mutagenical Safety Evaluation of Gamma Irradiated Ready-to-Eat Foods of Animal Origin (즉석식품 제조를 위한 육가공제품의 감마선 조사에 따른 미생물 및 유전독성학적 안전성 평가)

  • Lee Na-Young;Jo Cheorun;Kang Ho-Jin;Hong Sang-Pill;Kim Young-Ho;Lee Kyong-Haeng;Byun Myung-Woo
    • Food Science of Animal Resources
    • /
    • v.25 no.1
    • /
    • pp.13-19
    • /
    • 2005
  • The radio-sensitivity of pathogens and the effect of irradiation on microbiologican safety and mutagenicity of meat products such as seasoned and cooked beef and ham were investigated. Samples were radiation-sterilized and inoculated at 10/sup 7/ cfu/g with each of the four pathogens including Salmonella typhimurium, Escherichia coli, Staphylcoccus aureus, and Listeria ivanovii. No viable cells of pathogens were observed in the sample irradiated with 3 kGy. The D/sub 10/ value of inoculated pathogens in seasoned and cooked beef and ham were 0.24∼0.48 and 0.39∼0.45, respectively. Results of Ames test performed with non-irradiated and irradiated seasoned and cooked beef and ham were both negative at the level of 625, 1,250, 2,500, 50,000, and! 10,000 ㎍ sample/plate, respectively. Results indicate that low dose (2∼3 kGy) irradiation is effective to ensure safety for seasoned and cooked beef and ham with toxicological wholesomeness.

Shelf life of Bottled Sea Squirt Halocynthia roretzi Meat Packed in Vegetable Oil (BSMO)

  • Choi, Nam-Do;Zeng, Jiting;Choi, Byung-Dae;Ryu, Hong-Soo
    • Fisheries and Aquatic Sciences
    • /
    • v.17 no.1
    • /
    • pp.37-46
    • /
    • 2014
  • Fresh sea squirt meat requires a modified processing and preservation process because it has a short shelf life due to its high moisture content and strong proteolytic enzyme activity. In this study, bottled sea squirt meat prepared in vegetable oil (BSMO) to enhance the consumer acceptability was exposed to ${\gamma}$-ray (Co60, 10 kGy/h) irradiation to extend the shelf life without the use of a heating process. Response surface methodology was used to determine the optimal mixing ratio of BSMO containing 5% dehydrated fresh meat. Texture analysis and nutritional evaluation were also performed on a control and BSMO samples. The volatile basic nitrogen (VBN) content and total cell count were measured to determine the shelf life of irradiated BSMO products during chilled storage at $4^{\circ}C$ for 60 days. According to a panel of 10 trained tasters (aged 20-29 years), the optimal mixing formulation was 80 g meat in 60 mL of mixed vegetable oil (30 mL of olive oil and 30 mL of sesame oil). The highest rated formulation, according to a panel of nine trained tasters (aged ${\geq}30$ years), was 80 g meat in 60 mL of mixed vegetable oil (42 mL of olive oil and 18 mL of sesame oil). Moisture, ash, and protein contents in BSMO did not change significantly (P < 0.05) compared with the control. A higher lipid content ($0.84{\pm}0.23$ to $2.13{\pm}0.61$; P < 0.05) was observed due to the presence of vegetable oil on the surface of BSMO. The vegetable oil raised the hardness, springiness, cohesiveness, gumminess, chewiness, and resilience of BSMO. BSMO products remained edible after 50 days of storage at $4^{\circ}C$ based on the VBN content (BSMO 1: $27.92{\pm}0.96$ mg/100 g, BSMO 2: $24.84{\pm}1.95$ mg/100 g) and total cell count (BSMO 1: $4.60{\pm}0.80$ log CFU/mL, BSMO 2: $3.65{\pm}0.20$ log CFU/mL) when compared with standard levels of VBN (25.00 mg/100 g) and total cell count (5 log CFU/mL), respectively. The results showed that irradiated BSMO products could help to expand the processed seafood market and increase the popularity of seafood among the younger generations.

Damage Study on the Mechanical Fastening in Laminated Composites (복합적층판(復合積層板)의 기계적(機械的) 체결부(締結部)에 관한 파손연구(破損硏究))

  • Kwan-Hyung,Song
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.27 no.4
    • /
    • pp.58-66
    • /
    • 1990
  • A series of test was performed measuring the failure strength and failure mode of Gr/Pi, $[0^{\circ}/45^{\circ}/90^{\circ}/-45^{\circ}]_s$ laminate containing a single pin loaded hole. The finite element method is applied to calculate the stress distribution in the laminates, then the failure load and the failure mode were predicted by means of the characteristic length. 12 different geometric variations were developed to analyze the effects of the ratio of specimen width to hole diameter (W/d) and ratio of edge distance to hole diameter (L/d). X-Ray of NDE methods were utilized in finding out the initial defects, damage and the fracture mechanism, and SEM(Scanning Electron Microscopes) was used the evaluation of the fracture mechanism and crack propagation around hole under tension pin loading. $[0^{\circ}/45^{\circ}/90^{\circ}/-45^{\circ}]_s$ laminate are found to be most sensitive to W/d but not so influenced by L/d. The failure mode and tensile strength predicted by the model show agreement with experiment data for pin loading bolted jointed test except range of $L/d{\leqq}3$.

  • PDF

Activity Concentrations of 137Cs and 90Sr in Seawaters of East Sea, Korea

  • Lee, Hae Young;Kim, Wan;Kim, Yong-Hwan;Maeng, Seongjin;Lee, Sang Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.268-273
    • /
    • 2016
  • Background: This study was a long-term evaluation of $^{137}Cs$ and $^{90}Sr$ activity concentrations in seawater samples from the East Sea, Korea, in order to establish current activity levels. Results and long-term monitoring trends will be useful in the future monitoring of environmental radioactivity. Materials and Methods: Surface seawater samples were collected quarterly from Guryongpo and Jangho in the East Coast between 1998 and 2010 and the quarterly deep seawater samples were collected from three sites in the sea adjacent to Ulleung-do between 2012 and 2015. The activity concentrations of $^{137}Cs$ were measured using a gamma-spectrometer. The activity concentrations of $^{90}Sr$ and $^{90}Y$ in a radioactive equilibrium state were measured using a gas flow proportional counter. Results and Discussion: We found the annual average activity concentrations of $^{137}Cs$ in the surface seawater was $1.66-2.89mBq{\cdot}kg^{-1}$ in Guryongpo and $1.68-2.43mBq{\cdot}kg^{-1}$ in Jangho. The annual average activity concentrations of $^{90}Sr$ in the surface seawater was $0.83-1.98mBq{\cdot}kg^{-1}$ in Guryongpo and $0.82-1.57mBq{\cdot}kg^{-1}$ in Jangho. The annual average activity concentrations of $^{137}Cs$ in the deep seawater sites were $1.51-1.73mBq{\cdot}kg^{-1}$, $1.19-1.60mBq{\cdot}kg^{-1}$ and $0.87-1.15mBq{\cdot}kg^{-1}$ in TH, JD, and HP. The annual average activity concentrations of $^{90}Sr$ in the same deep seawater sites were $1.00-1.94mBq{\cdot}kg^{-1}$, $0.82-1.26mBq{\cdot}kg^{-1}$, and $0.79-1.32mBq{\cdot}kg^{-1}$. The effective half-life was calculated by analyzing change over time in the activity concentration in the surface seawater. The effective half-life of $^{137}Cs$ was $15.3{\pm}0.1years$ in Guryongpo and $102{\pm}3years$ in Jangho. The effective half-life of $^{90}Sr$ was $28.3{\pm}4.3years$ in Guryongpo and $16.6{\pm}0.1years$ in Jangho. The ratio of the average activity concentration ($^{137}Cs/^{90}Sr$) was 1.72 in the surface seawater, which is similar to the reported ratio of the global radioactive fallout. The ratio in the deep seawater was 1.24, which is somewhat low compared to the global ratio (1.6, 1.8). Conclusion: Activity concentrations of $^{137}Cs$ and $^{90}Sr$ in the seawaters of the East Sea were similar to the previously reported activity levels in the East Sea and northwestern Pacific as a result of global radioactive fallout following atmospheric nuclear weapon tests.

Thermoluminescence Dating of Pottery Shards by Subtraction Method (Subtraction 방법을 이용한 TL 연대측정법에 의한 토기 시편의 절대연대 결정)

  • Shin, Hyun-Sang;Lee, Chang-Woo;Nam, Young-Mee;Jee, Kwang-Yong;Park, Byung-Bin
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.403-411
    • /
    • 2000
  • This study described a method of thermoluminescence dating of pottery shards using subtraction method. TL measurement was achieved using two different types of samples prepared by quartz inclusion method and fine-grain technique. Fine grains (size range: $5-10{\mu}m$) were separated by suspending grounded pottery samples into acetone solution and sedimentation quantitatively. In quartz inclusion method quartz grains in the size range of 90 to $125{\mu}m$ diameter were obtained by extracting the quartz crystals embed in the pottery shards and etching them with 1.0 M HF solutions. The archaeological dose of both the quartz and fine grains was determined from the dose calibration curves obtained from sequential irradiation of $^{137}Cs$ gamma and $^{241}Am$ alpha source to the samples and TL measurement of natural samples, in which the alpha dose of 4.60 Gy for the Packjae pottery was obtained using subtraction method. Annual alpha dose rates ($3.05{\pm}0.11$ mGy/yr.) were determined by the analysis of U, Th contents in the pottery shards and evaluation of the values with Bell's equation. Dividing the alpha dose accumulated in the pottery shards by the annual alpha dose rate, we found age of approximately $1508{\pm}80$ years B.P. (AD. ca. 492 yr.) for the Packjae pottery. It matches well with the archeological age estimate (middle of 5th century) within 10 percent uncertainty and thereby conforms the age of the pottery sample.

  • PDF

A Study of Carry Over Contamination in Chematology (이월오염에 대한 연구)

  • Chang, Sang-Wu;Kim, Nam-Yong;Lyu, Jae-Gi;Jung, Dong-Jin;Kim, Gi-You;Park, Yong-Won;Chu, Kyung-Bok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.3
    • /
    • pp.178-184
    • /
    • 2005
  • Carry over contamination has been reduced in some systems by flushing the internal and external surfaces of the sample probe with copious amount of diluent. It between specimens should be kept as small as possible. A built-in, continuous-flow wash reservoir, which allows the simultaneous washing of the interior and exterior of the syringe needles, addresses this issue. In addition, residual contamination can further be prevented through the use of efficient needle rinsing procedures. In discrete systems with disposable reaction vessels and measuring cuvets, any carry over is entirely caused by the pipetting system. In analyzers with reuseable cuvets or flow cells, carry over may arise at every point through which high samples pass sequentially. Therefore, disposable sample probe tips can eliminate both the contamination of one sample by another inside the probe and the carry over of in specimen into the specimen in the cup. The results of the applicative carry over experiment studied on 21 items for total protein (TP), albumin (ALB), total bilirubin (TB), alkaline phosphatase (ALP), aspratate aminotranferase (AST), alanine aminotranferase (ALT), gamma glutamyl transferase (GGT), creatinine kinase (CK), lactic dehydrogenase (LD), creatnine (CRE), blood urea nitrogen (BUN), uric acid (UA), total cholesterol (TC), triglyceride (TG), glucose (GLU), amylase (AMY), calcium (CA), inorganic phosphorus (IP), sodium (Na), potassium (K), chloride (CL) tests in chematology were as follows. Evaluation of process performance less than 1% in all tests was very good, but a percentage of ALB, TP, TB, ALP, CRE, UA, TC, GLU, AMY, IP, K, Na, and CL was 0%, implying no carry over. Other tests were ALT(-0.08%), GGT(-0.09%), CK(0.08%), LD(0.06%), BUN(0.12%), TG (-0.06%), and CA(0.89%).

  • PDF

An Empirical Study of the Analytical Measurement Range in Clinical Chemistry (분석측정범위의 실증적 평가)

  • Chang, Sang-Wu;Lee, Sang-Gon;Kim, Young-Hwan;Song, Eun-Young;Park, Yong-Won;Park, Byong-Ok;Lyu, Jae-Gi
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.38 no.2
    • /
    • pp.117-124
    • /
    • 2006
  • The analytical measurement range (AMR) is the range of analyte values that a method can directly measure on a specimen without any dilution, concentration, or other pretreatment not part of the usual assay process. The linearity of the AMR is its ability to obtain test results which are directly proportional to the concentration of analyte in the sample from the upper and lower limit of the AMR. The AMR validation is the process of confirming that the assay system will correctly recover the concentration or activity of the analyte over the AMR. The test specimen must have analyte values which, at a minimum, are near the low, midpoint, and high values of the AMR. The AMR must be revalidated at least every six months, at changes in major system components, and when a complete change in reagents for a procesure is introduced; unless the laboratory can demonstrate that changing the reagent lot number does not affect the range used to report patient test results. The AMR linearity was total protein (0-16.6), albumin (0-8.1), total bilirubin (0-18.1), alkaline phosphatase (0-1244.3), aspartate aminotransferase (0-1527.9), alanine aminotransferase (0-1107.9), gamma glutamyl transpeptidase (0-1527.7), creatine kinase (0-1666.6), lactate dehydrogenase (0-1342), high density lipoprotein cholesterol (0.3-154.3), sodium (35.4-309), creatinine (0-19.2), blood urea nitrogen (0.5-206.2), uric acid (0-23.9), total cholesterol (-0.3-510), triglycerides (0.7-539.6), glucose (0-672.7), amylase (0-1595.3), calcium (0-23.9), inorganic phosphorus (0.03-17.0), potassium (0.1-116.5), chloride (3.3-278.7). We are sure that materials for the AMR affect the evaluation of the upper limit of the AMR in the process system.

  • PDF