• 제목/요약/키워드: Gamma evaluation

검색결과 713건 처리시간 0.031초

감마선 조사 당귀(Angelica gigas Nakai)의 유효성분 안정성 및 유전독성학적 안전성 연구 (Evaluation on the Safety of ${\gamma}$-Irradiated Angelica gigas Nakai: Stability of Active Components and Safety in Genotoxicity Test)

  • 조성기;유영법
    • 한국식품영양과학회지
    • /
    • 제29권2호
    • /
    • pp.300-306
    • /
    • 2000
  • In the present studies, we assessed the stability of active components and toxicological safety of irradiated Angelica gigas Nakai(Danggui). In order to confirm the stability of active components in the ${\gamma}$-irradiated roots of Danggui, the quantitative analysis of decursin and decursinol angelate of ${\gamma}$-irradiated sample was carried out by high performance liquid chromatographic (HPLC) methods using reverse phase columns and normal phase columns. From the root of Danggui, decursin and decursinol angelate were isolated by a silica gel column chromatography(toluene : ether (1 : 1), Hexane : EtOAc(15 : 1)). And then the structures were confirmed in the 1H and 13C-NMR analysis. The HPLC chromatograms of decursin and decursinol angelate in ${\gamma}$-irradiated Danggui were similar with those of non-irradiated sample. In the examination of in vitro genotoxicity of the water extract from ${\gamma}$-irradiated Danggui using Salmonella reversion assay(Ames test) and micronucleus test in Chinese hamster ovary (CHO) cells, mutagenicity was not exhibited in the two assays with or without metabolic activation. These resutls suggest that active components in the ${\gamma}$-irradiated Danggui should be stable and that the safety of ${\gamma}$-irradiated Danggui could be revealed in further test in vivo.

  • PDF

Fast non-local means noise reduction algorithm with acceleration function for improvement of image quality in gamma camera system: A phantom study

  • Park, Chan Rok;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.719-722
    • /
    • 2019
  • Gamma-ray images generally suffer from a lot of noise because of low photon detection in the gamma camera system. The purpose of this study is to improve the image quality in gamma-ray images using a gamma camera system with a fast nonlocal means (FNLM) noise reduction algorithm with an acceleration function. The designed FNLM algorithm is based on local region considerations, including the Euclidean distance in the gamma-ray image and use of the encoded information. To evaluate the noise characteristics, the normalized noise power spectrum (NNPS), contrast-to-noise ratio (CNR), and coefficient of variation (COV) were used. According to the NNPS result, the lowest values can be obtained using the FNLM noise reduction algorithm. In addition, when the conventional methods and the FNLM noise reduction algorithm were compared, the average CNR and COV using the proposed algorithm were approximately 2.23 and 7.95 times better than those of the noisy image, respectively. In particular, the image-processing time of the FNLM noise reduction algorithm can achieve the fastest time compared with conventional noise reduction methods. The results of the image qualities related to noise characteristics demonstrated the superiority of the proposed FNLM noise reduction algorithm in a gamma camera system.

Quality Evaluation of Sliced and Pizza Cheeses Treated by Gamma and Electron Beam Irradiation

  • Kim, Hyun-Joo;Ham, Jun-Sang;Kim, Kee-Hyuk;Ha, Ji-Hyoung;Ha, Sang-Do;Jo, Cheo-Run
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제23권8호
    • /
    • pp.1112-1117
    • /
    • 2010
  • This study was conducted to evaluate and compare the quality changes of commercial sliced and pizza cheeses processed by gamma and electron beam irradiation. The $L^*$-value of sliced and pizza cheeses decreased and the $a^*$-value decreased only in pizza cheese by both irradiation sources. There was no change in pH. There was no difference in 2-thiobarbituric acid reactive substances (TBARS) value between non-irradiated and irradiated samples at a dose of 3 kGy or less (p<0.05). However, both irradiation sources resulted in increased TBARS value in sliced and pizza cheeses at 5 kGy. Sensory evaluation revealed that irradiation influenced odor, taste and overall acceptability of both cheeses and may cause the limitation of consumers' acceptance for irradiated cheese products. Results indicate that both gamma and electron beam irradiations with less than 3 kGy may not influence significantly the physicochemical quality of sliced and pizza cheeses. However, to meet a market requirement, a method to overcome the sensory deterioration of cheeses should be developed and applied.

Preparation of Ag, Pd, and Pt50-Ru50 colloids prepared by γ-irradiation and electron beam and electrochemical immobilization on gold surface

  • Kim, Kyung-Hee;Seo, Kang-Deuk;Oh, Seong-Dae;Choi, Seong-Ho;Oh, Sang-Hyub;Woo, Jin-Chun;Gopalan, A.;Lee, Kwang-Pill
    • 분석과학
    • /
    • 제19권4호
    • /
    • pp.333-341
    • /
    • 2006
  • PVP-protected Ag, Pd and $Pt_{50}-Ru_{50}$ colloids were prepared independently by using ${\gamma}$-irradiation and electron beam (EB) at ambient temperature. UV-visible spectra of these colloids show the characteristic bands of surface resonance and give evidence for the formation of nanoparticles. Transmission electron microscopy (TEM) experiments were used to know the morphology of nanoparticles prepared by ${\gamma}$-irradiation and EB. The size of Ag, Pd, and $Pt_{50}-Ru_{50}$ nanoparticles prepared by ${\gamma}$-irradiation was ca. 13, 2-3, 15 nm, respectively. While, the size of Ag, Pd, and $Pt_{50}-Ru_{50}$ nanoparticles prepared by EB was ca. 10, 6, and 1-3 nm, respectively. Cyclic voltamograms (CV) were recorded for the Au electrodes immobilized with these nanoparticles. CVs indicated the modifications in the surface as a result of immobilization.

Region-wise evaluation of gamma-ray exposure dose in decontamination operation after a nuclear accident

  • Jeong, Hae Sun;Hwang, Won Tae;Han, Moon Hee;Kim, Eun Han;Lee, Jo Eun;Lee, Cheol Woo
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2652-2660
    • /
    • 2021
  • The gamma-ray exposure doses in decontamination operation after a nuclear accident were evaluated with a consideration of various geometrical conditions and specific gamma-ray energies. The calculation domain is organized with three residence types and each form is divided into two kinds of geometrical arrangements. The position-wise air KERMA values were calculated with an assumption of evenly distributed gamma-ray source based on Monte Carlo radiation transport analysis using the MCNP code. The radioactivity is initially set to be unity to be multiplied by the deposition value measured in the actual accident condition. The workforce data set depending on the target object was determined by modifying the Fukushima report. The external exposure doses for decontamination workers were derived from the calculated KERMA values and the workforce analysis. These results can be used to efficiently determine the workforce required by the characteristics of the area and the structure to be decontaminated within the dose limits.

진단용 무선 감마선 프로브 개발 및 유용성 평가 (Development of a Wireless Gamma-ray Probe for Diagnosing and Evaluation of its Effectiveness)

  • 박혜민;주관식
    • 전자공학회논문지
    • /
    • 제52권2호
    • /
    • pp.173-181
    • /
    • 2015
  • 연구에서는 진단 및 수술 후 잔여병소의 검출을 위하여 방사선계수 방식의 무선 감마선 프로브를 개발하고, 교정선원과 팬텀을 이용하여 그 유용성을 평가 하였다. 반도체기반 방사선센서를 사용하여 프로브 설계 및 소형화 하였으며, 블루투스 원격통신 모듈을 사용하여 진단 및 검출 시스템의 무선화를 구현하였다. 또한 진단 및 수술 시 환부의 모니터링이 가능한 원격모니터링 시스템을 구현하였다. 개발된 프로브의 유용성 평가를 위해 교정선원 $^{57}Co$, $^{133}Ba$, $^{22}Na$, $^{137}Cs$과 닭 가슴살 팬텀을 사용하였다. 평가를 통해 감마선에 대한 프로브의 검출 반응성을 확인하였고, 감마선 세기에 따른 응답 선형성과 검출 방향성, 팬텀 내 선원 깊이에 따른 프로브의 검출효율을 평가를 통해 실증적인 임상에서의 적용 가능성을 확인하였다.

${\gamma}$-cyclodextrin으로 포접한 홍삼추출물의 관능평가 및 Rg1, Rb1의 생체이용율 (Sensory Evaluation and Bioavailability of Red Ginseng Extract(Rg1, Rb1) by Complexation with ${\gamma}$-Cyclodextrin)

  • 이승현;박지호;조남석;유희종;유성균;조정원;김동출;김영희;김기호
    • 한국식품과학회지
    • /
    • 제41권1호
    • /
    • pp.106-110
    • /
    • 2009
  • 홍삼추출물(RGE)의 쓴 맛을 개선하기 위해서 ${\alpha}-,\;{\beta}-,\;{\gamma}$-CD을 이용해서 RGE의 포접화합물을 제조하여, 관능평가를 통해서 RGE-${\gamma}$-CD에 의한 쓴 맛 개선효과가 가장 큰 것을 확인하였다. RGE와 ${\gamma}$-CD의 비율에 따라서 쓴 맛은 선형적으로 감소하지만, RGE 고유의 향 조차도 감소하기 때문에, RGE 대비 10%의 ${\gamma}$-CD를 첨가하여 포접화합물을 형성할 때 쓴 맛은 RGE 대비 78% 정도 감소하였고, 홍삼의 향은 62% 정도를 유지함으로써 기호도면에서 우수한 결과를 얻었다. SD계 흰쥐에 RGE, RGE-${\gamma}$-CD10의 제제를 총 사포닌의 투여량이 제제간에 동일하도록 투여한 후, 혈장 중 RGE에 들어있는 주요한 성분으로 알려져 있는 ginsenoside Rg1, Rb1을 지표물질로 설정하여 전 농도를 측정하여 두 제제간의 AUC를 비교한 결과, Rg1의 경우, RGE 제제 투여 후의 평균값이 $13.11{\mu}g{\cdot}hr/mL$, RGE-${\gamma}$-CD10 투여 후의 평균값은 $12.04{\mu}g{\cdot}hr/mL$로 유의적인 차이는 없었다. 한편, Rb1의 경우, RGE 제제로서 투여하였을 때의 AUC 평균값이 $25.84{\mu}g{\cdot}hr/mL$, RGE-${\gamma}$-CD10 투여 후의 평균값은 $81.48{\mu}g{\cdot}hr/mL$로 3배 이상 높아짐을 알 수 있었다. 본 연구에 의해 ${\gamma}$-CD로 RGE를 포접했을 경우 쓴 맛이 감소하고, ginsenoside Rb1의 생체이용율이 증가하여 RGE를 그대로 섭취할 경우보다 포접화합물로 섭취 시에 더 유용함을 확인하였다.

감마선 처리를 이용한 고무공장 폐수의 생물독성 저감 (Toxicity Reduction of Wastewater from a Rubber Products Manufacturing Factory by Gamma-ray Treatment)

  • 박은주;조훈제;조기종;김정규;정진호
    • 한국물환경학회지
    • /
    • 제22권5호
    • /
    • pp.913-918
    • /
    • 2006
  • Both raw wastewater and effluent from a rubber products manufacturing factory were found to be toxic to Daphnia magna though the effluent satisfied current water quality standards. Thus, in order to reduce toxicity, advanced oxidation processes (AOPs) such as gamma-ray (${\gamma}-ray$) treatment and ozonation ($O_3$) were applied. A combined ${\gamma}-rays/O_3$ treatment at 20 kGy after coagulation significantly reduced toxicity of raw wastewater, changing 48-h toxic unit (TU) value from 201.21 to 23.92. However, toxicity of treated water was higher than that of effluent (TU = 12.15). This shows limitation of gamma-ray treatment to remove toxicity of raw wastewater. In case of effluent, the combined ${\gamma}-rays/O_3$ treatment at 20 kGy efficiently decomposed toxic compounds down to non toxic level. This work strongly supports the necessity of toxicity reduction evaluation as well as toxicity-based effluent management.

Validation of Gamma Knife Perfexion Dose Profile Distribution by a Modified Variable Ellipsoid Modeling Technique

  • Hur, Beong Ik;Jin, Seong Jin;Kim, Gyeong Rip;Kwak, Jong Hyeok;Kim, Young Ha;Lee, Sang Weon;Sung, Soon Ki
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권1호
    • /
    • pp.13-22
    • /
    • 2021
  • Objective : High precision and accuracy are expected in gamma knife radiosurgery treatment. Because of the requirement of clinically applying complex radiation and dose gradients together with a rapid radiation decline, a dedicated quality assurance program is required to maintain the radiation dosimetry and geometric accuracy and to reduce all associated risk factors. This study investigates the validity of Leksell Gamma plan (LGP)10.1.1 system of 5th generation Gamma Knife Perfexion as modified variable ellipsoid modeling technique (VEMT) method. Methods : To verify LGP10.1.1 system, we compare the treatment plan program system of the Gamma Knife Perfexion, that is, the LGP, with the calculated value of the proposed modified VEMT program. To verify a modified VEMT method, we compare the distributions of the dose of Gamma Knife Perfexion measured by Gafchromic EBT3 and EBT-XD films. For verification, the center of an 80 mm radius solid water phantom is placed in the center of all sectors positioned at 16 mm, 4 mm and 8 mm; that is, the dose distribution is similar to the method used in the x, y, and z directions by the VEMT. The dose distribution in the axial direction is compared and analyzed based on Full-Width-of-Half-Maximum (FWHM) evaluation. Results : The dose profile distribution was evaluated by FWHM, and it showed an average difference of 0.104 mm for the LGP value and 0.130 mm for the EBT-XD film. Conclusion : The modified VEMT yielded consistent results in the two processes. The use of the modified VEMT as a verification tool can enable the system to stably test and operate the Gamma Knife Perfexion treatment planning system.