• Title/Summary/Keyword: Gamma analysis

Search Result 2,235, Processing Time 0.024 seconds

A CCD Camera Lens Degradation Caused by High Dose-Rate Gamma Irradiation (고 선량율 감마선 조사에 따른 렌즈의 열화)

  • Cho, Jai-Wan;Lee, Joon-Koo;Hur, Seop;Koo, In-Soo;Hong, Seok-Boong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1450-1455
    • /
    • 2009
  • Assumed that an IPTV camera system is to be used as an ad-hoc sensor for the surveillance and diagnostics of safety-critical equipments installed in the in-containment building of the nuclear power plant, an major problem is the presence of high dose-rate gamma irradiation fields inside the one. In order to uses an IPTV camera in such intense gamma radiation environment of the in-containment building, the radiation-weakened devices including a CCD imaging sensor, FPGA, ASIC and microprocessors are to be properly shielded from high dose-rate gamma radiation using the high-density material, lead or tungsten. But the passive elements such as mirror, lens and window, which are placed in the optical path of the CCD imaging sensor, are exposed to a high dose-rate gamma ray source directly. So, the gamma-ray irradiation characteristics of the passive elements, is needed to test. A CCD camera lens, made of glass material, have been gamma irradiated at the dose rate of 4.2 kGy/h during an hour up to a total dose of 4 kGy. The radiation induced color-center in the glass lens is observed. The degradation performance of the gamma irradiated lens is explained using an color component analysis.

BER Analysis of Coherent Free Space Optical Systems with BPSK over Gamma-Gamma Channels

  • Lim, Wansu
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.3
    • /
    • pp.237-240
    • /
    • 2015
  • We derived the average bit error rate (BER) of coherent free-space optical (FSO) systems with digital binary phase shift keying (BPSK) modulations over atmospheric turbulence channels with a gamma-gamma distribution. To obtain a generalized derivation in a closed-form expression, we used special integrals and transformations of the Meijer G function. Furthermore, we numerically analyzed and simulated the average BER behavior according to the average SNR for different turbulence strengths. Simulation results are demonstrated to confirm the analytical results.

NEW DEVELOPMENT OF HYPERGAM AND ITS TEST OF PERFORMANCE FOR γ-RAY SPECTRUM ANALYSIS

  • Park, B.G.;Choi, H.D.;Park, C.S.
    • Nuclear Engineering and Technology
    • /
    • v.44 no.7
    • /
    • pp.781-790
    • /
    • 2012
  • The HyperGam program was developed for the analysis of complex HPGe ${\gamma}$-ray spectra. The previous version of HyperGam was mainly limited to the analysis of ${\gamma}$-ray peaks and the manual logging of the result. In this study, it is specifically developed into a tool for the isotopic analysis of spectra. The newly developed features include nuclide identification and activity determination. An algorithm for nuclide identification was developed to identify the peaks in the spectrum by considering the yield, efficiency, energy and peak area for the ${\gamma}$-ray lines emitted from the radionuclide. The detailed performance of nuclide identification and activity determination was accessed using the IAEA 2002 set of test spectra. By analyzing the test spectra, the numbers of radionuclides identified truly (true hit), falsely (false hit) or missed (misses) were counted and compared with the results from the IAEA 2002 tests. The determined activities of the radionuclides were also compared for four test spectra of several samples. The result of the performance test is promising in comparison with those of the well-known software packages for ${\gamma}$-ray spectrum analysis.

ANALYSIS OF DOPPLER-BROADENED PEAK IN THERMAL NEUTRON INDUCED 10B(n,α γ)7Li REACTION USING HYPERGAM

  • Choi, Hee-Dong;Jung, Nam-Suk;Park, Byung-Gun
    • Nuclear Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.113-124
    • /
    • 2009
  • The line shape functions for the Doppler-broadened gamma ray spectrum are considered in the $^{10}B(n,{\alpha}{\gamma})^7Li$ reaction occurring in a surrounding medium where the excited $^7Li$ nucleus is slowed down and stopped before decay. The phenomenological form of the stopping power was used for the broadening effect. Convolution with the detailed response of a germanium detector is taken into consideration for the simplest case of solely electronic stopping. A numerical study for the analysis of $^{10}B$ by thermal neutron capture is conducted by performing a parametric search and fitting the measured spectrum in a least-squares approach. In comparison with the previous numerical approach using the same analysis, the computational speed is increased and reliable information concerning the stopping power of the medium is obtained while estimating the uncertainty. Implementation of the routine analysis of $^{10}B$ is facilitated on a recent version of the gamma ray spectrum analysis package HyperGam.

Separation Effect Analysis for Rainfall Data (강우자료의 분리효과)

  • 김양수;허준행
    • Water for future
    • /
    • v.26 no.4
    • /
    • pp.73-83
    • /
    • 1993
  • This study focuses on the separation effect analysis of rainfall data for 2-parameter log-normal, 3-parameter log-normal, type-extreme value, 2-parameter gamma, 3-parameter gamma, log-Pearson type-III, and general extreme value distribution functions. Difference in the relationship between the mean and standard deviation of skewness for historical data and relations derived from 7 distribution functions are analyzed suing the Monte Carlo experiment. The results show that rainfall data has the separation effect for 6 distribution functions except 3-parameter gamma distribution function.

  • PDF

Precise Determination of Silicon in Ceramic Reference Materials by Prompt Gamma Activation Analysis at JRR-3

  • Miura, Tsutomu;Matsue, Hideaki
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.299-303
    • /
    • 2016
  • Prompt gamma activation analysis using a thermal neutron-guided beam at Japan Atomic Energy Agency JRR-3M was applied for the precise determination of Si in silicon nitride ceramic reference materials [Japan Ceramic Reference Material (JCRM) R 003]. In this study, the standard addition method coupled with internal standard was used for the nondestructive determination of Si in the sample. Cadmium was used as internal standard to obtain the linear calibration curves and to compensate for the neutron beam variability. The analytical result of determining Si in JCRM R 003 silicon nitride fine powder ceramic reference materials using prompt gamma activation analysis was in good agreement with that obtained by classical gravimetric analysis. The relative expanded measurement uncertainty (k = 2) associated with the determined value was 2.4%.

Study of n/γ discrimination using 3He proportional chamber in high gamma-ray fields

  • Choi, Joonbum;Park, Junesic;Son, Jaebum;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.263-268
    • /
    • 2019
  • The $^3He$ proportional chamber is widely used for neutron measurement owing to its high neutron detection efficiency and simplicity for gamma-ray rejection. In general, the neutron and gamma-ray signals obtained from the $^3He$ proportional chamber can be easily separated by the difference in the pulse heights. However, for a high gamma-ray field, the gamma-ray signal cannot be precisely eliminated by the pulse height due to gamma-ray pulse pileup which causes the pulse height of gamma-ray pulse to increase and making the pulses due to neutrons and gamma rays indistinguishable. In this study, an improved algorithm for $n/{\gamma}$ discrimination using a parameter, which is the ratio of the rise time to the pulse height, is proposed. The $n/{\gamma}$ discrimination performance of the algorithm is evaluated by applying it to $^{252}Cf$ neutron signal separation from various gamma-ray exposure rate levels ranging 0.1-5 R/h. The performance is compared to that of the conventional pulse-height analysis method in terms of the gamma elimination ratio. The suggested algorithm shows better performance than the conventional one by 1.7% (at 0.1 R/h) to 70% (at 5 R/h) for gamma elimination.

Gamma-ray Full Spectrum Analysis for Environmental Radioactivity by HPGe Detector

  • Jeong, Meeyoung;Lee, Kyeong Beom;Kim, Kyeong Ja;Lee, Min-Kie;Han, Ju-Bong
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.4
    • /
    • pp.317-323
    • /
    • 2014
  • Odyssey, one of the NASA's Mars exploration program and SELENE (Kaguya), a Japanese lunar orbiting spacecraft have a payload of Gamma-Ray Spectrometer (GRS) for analyzing radioactive chemical elements of the atmosphere and the surface. In these days, gamma-ray spectroscopy with a High-Purity Germanium (HPGe) detector has been widely used for the activity measurements of natural radionuclides contained in the soil of the Earth. The energy spectra obtained by the HPGe detectors have been generally analyzed by means of the Window Analysis (WA) method. In this method, activity concentrations are determined by using the net counts of energy window around individual peaks. Meanwhile, an alternative method, the so-called Full Spectrum Analysis (FSA) method uses count numbers not only from full-absorption peaks but from the contributions of Compton scattering due to gamma-rays. Consequently, while it takes a substantial time to obtain a statistically significant result in the WA method, the FSA method requires a much shorter time to reach the same level of the statistical significance. This study shows the validation results of FSA method. We have compared the concentration of radioactivity of $^{40}K$, $^{232}Th$ and $^{238}U$ in the soil measured by the WA method and the FSA method, respectively. The gamma-ray spectrum of reference materials (RGU and RGTh, KCl) and soil samples were measured by the 120% HPGe detector with cosmic muon veto detector. According to the comparison result of activity concentrations between the FSA and the WA, we could conclude that FSA method is validated against the WA method. This study implies that the FSA method can be used in a harsh measurement environment, such as the gamma-ray measurement in the Moon, in which the level of statistical significance is usually required in a much shorter data acquisition time than the WA method.

Evaluation on the Safety of ${\gamma}$-Irradiated Angelica gigas Nakai: Stability of Active Components and Safety in Genotoxicity Test (감마선 조사 당귀(Angelica gigas Nakai)의 유효성분 안정성 및 유전독성학적 안전성 연구)

  • 조성기;유영법
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.29 no.2
    • /
    • pp.300-306
    • /
    • 2000
  • In the present studies, we assessed the stability of active components and toxicological safety of irradiated Angelica gigas Nakai(Danggui). In order to confirm the stability of active components in the ${\gamma}$-irradiated roots of Danggui, the quantitative analysis of decursin and decursinol angelate of ${\gamma}$-irradiated sample was carried out by high performance liquid chromatographic (HPLC) methods using reverse phase columns and normal phase columns. From the root of Danggui, decursin and decursinol angelate were isolated by a silica gel column chromatography(toluene : ether (1 : 1), Hexane : EtOAc(15 : 1)). And then the structures were confirmed in the 1H and 13C-NMR analysis. The HPLC chromatograms of decursin and decursinol angelate in ${\gamma}$-irradiated Danggui were similar with those of non-irradiated sample. In the examination of in vitro genotoxicity of the water extract from ${\gamma}$-irradiated Danggui using Salmonella reversion assay(Ames test) and micronucleus test in Chinese hamster ovary (CHO) cells, mutagenicity was not exhibited in the two assays with or without metabolic activation. These resutls suggest that active components in the ${\gamma}$-irradiated Danggui should be stable and that the safety of ${\gamma}$-irradiated Danggui could be revealed in further test in vivo.

  • PDF

Transformation of Arabidopsis gamma-Tocopherol Methyltransferase into Lettuce (Lactuca sativa L.) (애기장대 gamma-Tocopherol Methyltransferase 유전자를 이용한 상추의 형질전환)

  • 김명준;백소현;유남희;윤성중
    • Korean Journal of Plant Tissue Culture
    • /
    • v.27 no.6
    • /
    • pp.435-439
    • /
    • 2000
  • Explants of lettuce (Lactuca sativa L.) were cocultured with A. tumefaciens LBA 4404 harboring ${\gamma}$-tocopherol methyltransferase (${\gamma}$-TMT) gene from Arabidopsis thaliana. These explants were transferred to MS medium supplemented with 50 mg/L kanamycin, 500 mg/L carbenicillin, 0.1 mg/L NAA and 0.5 mg/L BA. After 4 weeks, kanamycin resistant shoots were obtained from the explants on the selection medium. The putative transgenic shoots were transferred to rooting MS medium supplemented with 50 mg/L kanamycin and 250 mg/L carbenicillin. Stable incorporation of the Arabidopsis ${\gamma}$-TMT cDNA into lettuce genomic DNA was confirmed by PCR and Southern analysis. HPLC analysis showed that $\alpha$- to ${\gamma}$-tocopherol ratio increased over four fold in a transgenic lettuce line indicating successful expression of the transgenic Arabidopsis ${\gamma}$-TMT in lettuce.

  • PDF