• Title/Summary/Keyword: Gamma analysis

Search Result 2,257, Processing Time 0.033 seconds

Isolation and Identiffication of Acinetobacter koreensis sp. nov. from Jang-Baek Waterfall (장백 폭포에서 분리한 Acinetobacter koreensis sp. nov.의 보고)

  • Lee, Ha-Yan;Yoo, Yong-Kyu;Seo, Pil-Soo;Lee, Jung-Sook;Lee, Keun-Chul;Lee, Sang-Seob
    • Korean Journal of Microbiology
    • /
    • v.43 no.1
    • /
    • pp.66-71
    • /
    • 2007
  • Two isolates of genus Acinetobacter were obtained from Jang-Baek waterfall in North Korea. Morphological characteristics of the isolated 2 strains were Gram-negative, aerobic and rod shape bacteria. Physiological and biochemical characterization of the isolated 2 strains were some different aspect from those of type strains. 16S rDNA sequence analysis showed that the two isolates shared 99.9% sequence similarity. Strains JB10 and $JB15^{T}$ were shown to belong to the Gammaproteobacteria and showed the highest levels of sequence similarity to Acinetobacter tandoii $4N13^{T}$ (97.3%), Acinetobacter haemolyticus $ATCC17906^{T}$ (97.2%), Acinetobacter johnsonii $DSM6963^{T}$ (97.2%), Acinetobacter junii $DSM6964^{T}$ (96.7%), Acinetobacter schindleri $LUH5832^{T}$ (97.0%) and Acinetobacter ursingii $LUH3792^{T}$ (96.6%). The major cellular fatty acid in Acinetobacter type strains and isolated strains included $C_{18:1}\;{\omega}9c\;and\;C_{16:1}\;{\omega}7c/C_{15:0}\;iso\;2OH$. Eventhough it was ascertained that the isolated strains were closely related to genus Acinetobacter, physiological and biochemical characteristics and the result of the isolated strains 16S rDNA analysis indicate some different aspects from those of type strains of genus Acinetohacter It is considered that the isolated JB10 (=KEMC 52-093) and $JB15^{T}\;(=KEMC\;52-094^{T})$ strains be new species of genus Acinetobacter. We name it as Acinetobacter koreensis sp. nov.

Assessment of Vascularization within Hydroxyapatite Ocular Implant by Bone Scintigraphy: Comparative Analysis of Planar and SPECT Imaging (Hydroxyapatite 안구보충물삽입술 후 골신티그라피를 이용한 섬유혈관증식 평가: 평면영상과 SPECT 영상에서의 비교)

  • Lim, Seok-Tae;Sohn, Myung-Hee;Park, Soon-Ah
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.6
    • /
    • pp.475-483
    • /
    • 1999
  • Purpose: Complete fibrovascular ingrowth within the hydroxyapatite ocular implant is necessary for peg drilling which is performed to Prevent infection and to provide motility to the ocular prosthesis. We compared planar bone scintigraphy and SPECT for the evaluation of the vascularization within hydroxyapatite ocular implants. Materials and Methods: Seventeen patients (M:F: 12:5, mean age; $50.4{\pm}17.5$ years) who had received a coralline hydroxyapatite ocular implant after enucleation surgery were enrolled. Patients underwent Tc-99m MDP planar bone and SPECT imaging by dual head gamma camera after their implant surgery (interval: $197{\pm}81$ days). Uptake on planar and SPECT images was graded visually as less than (grade 1), equal to (grade 2), and greater than (grade 3) nasal bridge activity. Quantitative ratio of implanted to non-implanted intraorbital activity was also measured. Vascularization within hydroxyapatite implants was confirmed by slit lamp examination and ocular movement. Results: All but three patients were considered to be vascularized within hydroxyapatite implants. In visual analysis of planar image and SPECT, grade 1 was noted in 9/18 (50%) and 6/18 (33%), respectively. Grade 2 pattern was 7/18 (39%) and 4/18 (22%), and grade 3 pattern was 2/18 (11%) and 8/18 (44%) respectively. When grade 2 or 3 was considered to be positive for vascularization, the sensitivity of planar and SPECT imaging were 60% (9/15) and 80% (12/15), respectively. In 3 patients with incomplete vascularization, both planar and SPECT showed grade 1 uptake The orbital activity ratios on planar imaging were not significantly different between complete and incomplete vascularization ($1.96{\pm}0.87$ vs $1.17{\pm}0.08$, p>0.05), however, it was significantly higher on SPECT in patients with complete vascularization ($8.44{\pm}5.45$ vs $2.20{\pm}0.87$, p<0.05). Conclusion: In the assessment of fibrovascular ingrowth within ocular implants by Tc-99m MDP bone scintigraphy, SPECT image appears to be more effective than planar scintigraphy.

  • PDF

Analysis on the Useful Nutrition Components of the Albizzia julibrissin Stems and Leaves (자귀나무 줄기와 잎의 유용 영양성분 분석)

  • Lee, Yang-Suk;Hong, Chang-Kyun;Seo, Soo-Jung;Kim, Nam-Woo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.8
    • /
    • pp.1143-1148
    • /
    • 2010
  • This research analyzed useful nutritional component data in stems and leaves of the Albizzia julibrissin for proximate composition, contents of soluble protein, reducing sugar, free sugar, total polyphenol compound, mineral, free amino acid, and amino acid derivative. The carbohydrate contents of A. julibrissin stems and leaves were 71.08% and 64.85%, and crude protein contents were 8.05% and 11.38%, respectively. In addition, the crude fat contents were 2.95% and 3.03%, and the crude ash contents were 8.98% and 9.07%, respectively. Reducing sugar and free sugar in stems were 711.80 mg% and 15.66 mg%, and 1,422.83 mg% and 40.3 mg% in leaves, respectively. The contents of soluble protein were 229.57 mg% in stems and 1,073.59 mg% in leaves. The polyphenol and flavonoid compounds were 446.67 mg% and 16.36 mg% in stems, and 2,583.33 mg% and 2,234.75 mg% in leaves. In the results of mineral analysis, the content of Ca was the highest in stems as 933.07 mg% followed by K (605.07 mg%). The content of K was also the highest (1,489.53 mg%) in leaves, and Ca was 287.73 mg%. The free amino acid content of A. julibrissin stems was 2,977.28 mg%, and 8,840.66 mg% in leaves. Total contents of amino acid derivative were 263.53 mg% in stems and 696.47 mg% in leaves.

EEG based Cognitive Load Measurement for e-learning Application (이러닝 적용을 위한 뇌파기반 인지부하 측정)

  • Kim, Jun;Song, Ki-Sang
    • Korean Journal of Cognitive Science
    • /
    • v.20 no.2
    • /
    • pp.125-154
    • /
    • 2009
  • This paper describes the possibility of human physiological data, especially brain-wave activity, to detect cognitive overload, a phenomenon that may occur while learner uses an e-learning system. If it is found that cognitive overload to be detectable, providing appropriate feedback to learners may be possible. To illustrate the possibility, while engaging in cognitive activities, cognitive load levels were measured by EEG (electroencephalogram) to seek detection of cognitive overload. The task given to learner was a computerized listening and recall test designed to measure working memory capacity, and the test had four progressively increasing degrees of difficulty. Eight male, right-handed, university students were asked to answer 4 sets of tests and each test took from 61 seconds to 198 seconds. A correction ratio was then calculated and EEG results analyzed. The correction ratio of listening and recall tests were 84.5%, 90.6%, 62.5% and 56.3% respectively, and the degree of difficulty had statistical significance. The data highlighted learner cognitive overload on test level of 3 and 4, the higher level tests. Second, the SEF-95% value was greater on test3 and 4 than on tests 1 and 2 indicating that tests 3 and 4 imposed greater cognitive load on participants. Third, the relative power of EEG gamma wave rapidly increased on the 3rd and $4^{th}$ test, and signals from channel F3, F4, C4, F7, and F8 showed statistically significance. These five channels are surrounding the brain's Broca area, and from a brain mapping analysis it was found that F8, right-half of the brain area, was activated relative to the degree of difficulty. Lastly, cross relation analysis showed greater increasing in synchronization at test3 and $4^{th}$ at test1 and 2. From these findings, it is possible to measure brain cognitive load level and cognitive over load via brain activity, which may provide atimely feedback scheme for e-learning systems.

  • PDF

A Comparison Study of Metaphase Analysis of Chromosomal Aberration and Flow Cytometric Assessment of Radiation-induced Apoptosis in Human Peripheral Lymphocytes (인체 말초혈액 림프구에서 방사선유도 염색체 손상 및 세포고사에 대한 중기염색체 분석 및 유세포계측 연구)

  • Bom, Hee-Seung;Lee, Seung-Yeon;Lee, Sang-Ku;Min, Jung-Jun;Jeong, Hwan-Jeong;Song, Ho-Cheon;Kim, Ji-Yeul;Shin, Jong-Hee;Suh, Sun-Pal;Rhang, Dong-Wook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.94-99
    • /
    • 1999
  • Purpose: Radiation-induced chromosomal damage and apoptosis were compared in human lymphocytes. Materials and Methods: Peripheral lymphocytes from 10 normal volunteers (6 males, 4 females, age range $23{\sim}41$ years) were irradiated by gamma rays from a cell irradiator. Doses of irradiation were 0 (control), 0.18, 2, 5, 10, 20 and 25 Gy. Irradiated lymphocytes were examined by metaphase analysis for chromosomal aberrations and by flow cytometry for apoptosis. Results of both studies were compared according to dose. Results: Number of dicentric and ring chromosomes (D+R) was $0.5{\pm}0.53$ at baseline, which was significantly increased after radiation according to the dose. The fraction of cells showing annexin V-fluorescein isothiocyanate uptake was $0.51{\pm}$0.39%, which increased to $3.58{\pm}1.85%$ by 2 Gy irradiation, and then decreased. The fraction of cells showing propidium iodide (PI) uptake was $0.52{\pm}0.12%$, which significantly increased according to dose (upto $15.64{\pm}5.99%$ by 20 Gy irradiation). D+R and PI uptake were well correlated (r=0.84, p<0.001). Conclusion: Radiation-induced chromosomal aberration was correlated to nuclear uptake of PI, a marker of late apoptosis.

  • PDF

Activation Analysis of Dual-purpose Metal Cask After the End of Design Lifetime for Decommission (설계수명 이후 해체를 위한 금속 겸용용기의 방사화 특성 평가)

  • Kim, Tae-Man;Ku, Ji-Young;Dho, Ho-Seog;Cho, Chun-Hyung;Ko, Jae-Hun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.4
    • /
    • pp.343-356
    • /
    • 2016
  • The Korea Radioactive Waste Agency (KORAD) has developed a dual-purpose metal cask for the dry storage of spent nuclear fuel that has been generated by domestic light-water reactors. The metal cask was designed in compliance with international and domestic technology standards, and safety was the most important consideration in developing the design. It was designed to maintain its integrity for 50 years in terms of major safety factors. The metal cask ensures the minimization of waste generated by maintenance activities during the storage period as well as the safe management of the waste. An activation evaluation of the main body, which includes internal and external components of metal casks whose design lifetime has expired, provides quantitative data on their radioactive inventory. The radioactive inventory of the main body and the components of the metal cask were calculated by applying the MCNP5 ORIGEN-2 evaluation system and by considering each component's chemical composition, neutron flux distribution, and reaction rate, as well as the duration of neutron irradiation during the storage period. The evaluation results revealed that 10 years after the end of the cask's design life, $^{60}Co$ had greater radioactivity than other nuclides among the metal materials. In the case of the neutron shield, nuclides that emit high-energy gamma rays such as $^{28}Al$ and $^{24}Na$ had greater radioactivity immediately after the design lifetime. However, their radioactivity level became negligible after six months due to their short half-life. The surface exposure dose rates of the canister and the main body of the metal cask from which the spent nuclear fuel had been removed with expiration of the design lifetime were determined to be at very low levels, and the radiation exposure doses to which radiation workers were subjected during the decommissioning process appeared to be at insignificant levels. The evaluations of this study strongly suggest that the nuclide inventory of a spent nuclear fuel metal cask can be utilized as basic data when decommissioning of a metal cask is planned, for example, for the development of a decommissioning plan, the determination of a decommissioning method, the estimation of radiation exposure to workers engaged in decommissioning operations, the management/reuse of radioactive wastes, etc.

Chemical Components and Antioxidative Effects of Eriobotrya japonica Lindl. Leaf (비파잎의 이화학적 성분과 항산화효과)

  • Hwang, Yun-Gyeong;Lee, Jae-Joon;Kim, Ah-Ra;Lee, Myung-Yul
    • Journal of Life Science
    • /
    • v.20 no.11
    • /
    • pp.1625-1633
    • /
    • 2010
  • This study was carried out to investigate the physicochemical compositions and antioxidative effects of Eriobotrya japonoca Lindl (Loquat). The proximate compositions of the loquat leaf on a dry matter basis were 8.78% moisture content, 6.74% crude protein, 7.87% crude fat, 6.99% crude ash, 43.61% dietary fiber and 26.01% carbohydrate. In analysis of free amino acids, 16 kinds total amino acid components, 17 kinds of components were isolated from loquat. The essential amino acids contained in loquat leaf accounted for 50.15% of total amino acids, while the non-essential amino acids accounted for 49.85%. In analysis of total fatty acids, only 5 kinds of acid were detected: lauric acid, myristic acid, pentadecanoic acid, stearic acid and oleic acid. The contents of vitamin A, vitamin E and vitamin C were 0.039 mg%, 0.096 mg% and 0.575 mg%, respectively. The mineral contents of loquat leaf were greater in order of Zn

Volatile Flavor Components and Free Radical Scavenging Activity of Cnidium officinale (천궁(Cnidium officinale)의 휘발성 향기성분 및 유리기 소거활성)

  • Lee, Ji-Hye;Choi, Hyang-Sook;Chung, Mi-Sook;Lee, Mie-Soon
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.330-338
    • /
    • 2002
  • This study was performed to develop natural spices and functional foods using Cheongung (Cnidium officinale) which is one of the Korean medicinal plants. The volatile flavor patterns of Cnidium officinale were detected by electronic nose with 6 metal oxide sensors, and the principal component analysis was carried out. The volatile flavor components of Cnidium officinale were isolated by simultaneous steam-distillation extraction with pentane and diethylether (1 : 1), and essential oils were analyzed by capillary GC and GC/MS. The free radical scavenging activity of ethanol and methanol extracts from Cnidium officinale was measured by using 1,1-diphenyl-2-picrylhydrazyl (DPPH) and compared with ${\alpha}-tocopherol$ as reference. The principal component analysis showed the difference of principal components between fresh and drying samples. Eighty-five volatile flavor components (643.64 ppm) from fresh Cnidium officinale were identified and the major components were butyl phthalide, sabinene, neocnidilide. Sixty-four volatile flavor components (218.15 ppm) from hot air dried one were identified and the major components were butyl phthalide, sabinene, 3-N-butyl phthalide. And 73 volatile flavor components (784.15 ppm) from freeze dried one were identified and the major components were butyl phthalide, sabinene, ${\beta}-selinene$. The free radical scavenging activity of methanol cold extract (500 ppm) of freeze dried Cnidium officinale was higher than other samples. And methanol and ethanol cold extracts (above 250 ppm) of freeze dried sample were higher than ${\alpha}-tocopherol$ $25\;{\mu}M$ (22.34%).

Modeling Paddlewheel-Driven Circulation in a Culture Pond (축제식 양식장에서 수차에 의한 순환 모델링)

  • KANG Yun Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.34 no.6
    • /
    • pp.643-651
    • /
    • 2001
  • Paddlewheel-driven circulation in a culture pond has been simulated based on the depth integrated 2 dimensional hydrodynamic model. Acceleration by paddlewheel is expressed as shaft force divided by water mass discharged by paddlewheel blades. The model has been calibrated and applied to culture ponds as following steps:- i) The model predicted velocities at every 10 m along longitudinal direction from the paddlewheel. The model was calibrated comparing the results with the measured values at mass correction factor $\alpha$ and dimensionless eddy viscosity constant $\gamma$, respectively, in a range $15\~20$ and 6. ii) Wind shear stress was simulated under conditions of direction $0^{\circ}C,\;90^{\circ}C\;and\;180^{\circ}C$ and speed 0.0, 2.5, 5.0 and 7.5 m/s. Change rate of current speed was <$1\%$ at wind in parallel or opposite direction to the paddlewheel-driven jet flow, while $4\%$ at orthogonal angle. iii) The model was then applied to 2 culture ponds located at the Western coast of Korea. The measured and predicted currents for the ponds were compared using the regression analysis. Analysis of flow direction and speed showed correlation coefficients 0.8928 and 0.6782 in pond A, 0.8539 and 0.7071 in pond B, respectively. Hence, the model is concluded to accurately predict circulation driven by paddlewheel such that it can be a useful tool to provide pond management strategy relating to paddlewheel operation and water quality.

  • PDF

A Study for Analysis of Image Quality Based on the CZT and NaI Detector according to Physical Change in Monte Carlo Simulation (CZT와 NaI 검출기 물질 기반 물리적 변화에 따른 영상의 질 분석에 관한 연구: 몬테카를로 시뮬레이션)

  • Ko, Hye-Rim;Yoo, Yu-Ri;Park, Chan-Rok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.741-748
    • /
    • 2021
  • In this study, we evaluated image quality by changing collimator length and detector thickness using the Geant4 Application for Tomographic Emission (GATE) simulation tool. The gamma camera based on the Cadimium Zinc Telluride (CZT) and NaI detectors is modeled. In addition the images were acquired by setting 1, 2, 3, 4, 5, and 6 cm collimator length and 1, 3, 5, and 7 mm detector thickness using point source and phantom, which is designed by each diameter (4.45, 3.80, 3.15, 2.55 mm) with 447, 382, 317, and 256 Bq. The sensitivity (cps/MBq) for point source, and signal to noise ratio (SNR) and profile for phantom at the 4.45 mm by drwan the region of interests were used for quantitative analysis. Based on the results, the sensitivity according to collimator length is 2.3 ~ 48.6 cps/MBq for CZT detector, and 1.8 ~ 43.9 cps/MBq for NaI detector. The SNR using phantom is 3.6~9.8 for CZT detector, and 2.9~9.5 for NaI detector. As the collimator length is increased, the image resolution is also improved according to profile results based on the CZT and NaI detector. In addition, the senistivity for detector thickness is 0.04 ~ 0.12 cps/MBq for CZT detector, and 0.03 ~ 0.11 cps/MBq. The SNR using phnatom is 7.3~9.8 count for CZT detector, and 5.9~9.5 for NaI detector. As the detector thickness is increased, the image resolution is decreased according to profile results based on the CZT and NaI detector due to scatter ray. In conclusion, we need to set the geometric material such as detector and collimator to acuquire suitable image quality in nuclear medicine.