• 제목/요약/키워드: Gamma Ray Energy Spectrum

검색결과 114건 처리시간 0.021초

청색 Diode 개발을 위한 ZnSe 박막성장과 특성에 관한 연구 (Growth and Characterization of ZnSe Thin Film for Blue Diode)

  • 박창선;홍광준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.533-538
    • /
    • 2001
  • The ZnSe sample grown by chemical bath deposition (CBD) method were annealed in Ar gas at 450$^{\circ}C$ Using extrapolation method of X-ray diffraction pattern, it was found to have zinc blend structure whose lattice parameter a$\_$o/ was 5.6687 ${\AA}$. From Hall effect, the mobility was likely to be decreased by impurity scattering at temperature range from 10 K to 150 K and by lattice scattering at temperature range from 150 K to 29 3K. The band gap given by the transmission edge changed from 2.7005 eV at 293 K to 2.8739 eV at 10 K. Comparing photocurrent peak position with transmission edge, we could find that photocurrent peaks due to excition electrons from valence band, $\Gamma$$\_$8/ and $\Gamma$$\_$7/ to conduction band $\Gamma$$\_$6/ were observed at photocurrent spectrum. From the photocurrent spectra by illumination of polarized light on the ZnSe thin film, we have found that values of spin orbit coupling splitting Δso is 0.0981 eV. From the PL spectra at 10 K, the peaks corresponding to free bound excitons and D-A pair and a broad emission band due to SA is identified. The binding energy of the free excitons are determined to be 0.0612 eV and the dissipation energy of the donor -bound exciton and acceptor-bound exciton to be 0.0172 eV, 0.0310 eV, respectively.

  • PDF

Pulse pileup correction method for gamma-ray spectroscopy in high radiation fields

  • Lee, Minju;Lee, Daehee;Ko, Eunbie;Park, Kyeongjin;Kim, Junhyuk;Ko, Kilyoung;Sharma, Manish;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • 제52권5호
    • /
    • pp.1029-1035
    • /
    • 2020
  • The detector suffers from pulse pileup by overlapping of the signals when it was used in high radiation fields. The pulse pileup deteriorates the energy spectrum and causes count losses due to random co-incidences, which might not resolve within the resolving time of the detection system. In this study, it is aimed to propose a new pulse pileup correction method. The proposed method is to correct the start point of the pileup pulse. The parameters are obtained from the fitted exponential curve using the peak point of the previous pulse and the start point of the pileup pulse. The amplitude at the corrected start point of the pileup pulse can be estimated by the peak time of the pileup pulse. The system is composed of a NaI (Tl) scintillation crystal, a photomultiplier tube, and an oscilloscope. A 61 μCi 137Cs check-source was placed at a distance of 3 cm, 5 cm, and 10 cm, respectively. The gamma energy spectra for the radioisotope of 137Cs were obtained to verify the proposed method. As a result, the correction of the pulse pileup through the proposed method shows a remarkable improvement of FWHM at 662 keV by 29, 39, and 7%, respectively.

CsSrCl3 단결정의 섬광특성 (Scintillation properties of CsSrCl3 single crystal)

  • 도시홍;김성환;나세진;김홍주;강희동;오문영
    • 센서학회지
    • /
    • 제16권5호
    • /
    • pp.337-341
    • /
    • 2007
  • $CsSrCl_{3}$ crystal was grown using Czochralski method from equimolar mixture of CsCl and $SrCl_{2}$. The spectrum range of the luminescence excited by 205 nm of wavelength was about $280{\sim}550$ nm, and its peak emission appeared at 343 nm. The luminescence decay curve of the $CsSrCl_{3}$ revealed two exponential components with time constants of 60 ns and 700 ns. The energy resolution for $^{137}Cs$ 662 keV ${\gamma}$-ray was 10.3 %. The pulse shape was linear at high energy, but some deviation existed in the low energy region.

Ambient dose equivalent measurement with a CsI(Tl) based electronic personal dosimeter

  • Park, Kyeongjin;Kim, Jinhwan;Lim, Kyung Taek;Kim, Junhyeok;Chang, Hojong;Kim, Hyunduk;Sharma, Manish;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • 제51권8호
    • /
    • pp.1991-1997
    • /
    • 2019
  • In this manuscript, we present a method for the direct calculation of an ambient dose equivalent (H* (10)) for the external gamma-ray exposure with an energy range of 40 keV to 2 MeV in an electronic personal dosimeter (EPD). The designed EPD consists of a 3 × 3 ㎟ PIN diode coupled to a 3 × 3 × 3 ㎣ CsI (Tl) scintillator block. The spectrum-to-dose conversion function (G(E)) for estimating H* (10) was calculated by applying the gradient-descent method based on the Monte-Carlo simulation. The optimal parameters for the G(E) were found and this conversion of the H* (10) from the gamma spectra was verified by using 241Am, 137Cs, 22Na, 54Mn, and 60Co radioisotopes. Furthermore, gamma spectra and H* (10) were obtained for an arbitrarily mixed multiple isotope case through Monte-Carlo simulation in order to expand the verification to more general cases. The H* (10) based on the G(E) function for the gamma spectra was then compared with H* (10) calculated by simulation. The relative difference of H* (10) from various single-source spectra was in the range of ±2.89%, and the relative difference of H* (10) for a multiple isotope case was in the range of ±5.56%.

γ-spectrometer를 이용한 토양시료의 라돈농도 측정법에 관한 연구 (Study on the Measurement of Radon concentrations in soil samples using γ-spectrometer)

  • 강성아;이상수;최규락;이준행
    • 한국방사선학회논문지
    • /
    • 제7권1호
    • /
    • pp.31-36
    • /
    • 2013
  • 우라늄($^{238}U$)의 붕괴과정에서 생성되는 방사성기체인 라돈($^{222}Rn$)은 발생원 중 토양에서 85 % 이상으로 토양의 공극률이 클수록 토양 밖으로 방출할 수 있는 가능성이 많은 동위원소이다. 라돈으로부터 인체를 보호하기 위해서 적절한 대책을 세우는데 무엇보다도 정확한 측정기술의 개발이 선행되어야 한다. 이에 본 연구는 고순도게르마늄(HPGe) 검출기를 이용한 감마선 분광분석법으로 라돈을 측정할 경우에는 불안정한 자연방사능의 백그라운드 문제를 줄일 수 있고, 라듐과 라돈의 딸 핵종들을 방사평형에 이르게 한 후 라돈 농도를 측정하였으며, 토양시료에서의 감마선 방출핵종 및 에너지 스펙트럼을 분석하였다.

저(低)에너지 X-선장(線場)에서 필름배지에 의한 개인피폭선량(個人被曝線量)의 결정(決定) (Determination of Personnel Exposures in the Lower Energy Ranges of X-Ray by Photographic Dosimeter)

  • 하정우;김장열;서경원
    • Journal of Radiation Protection and Research
    • /
    • 제11권1호
    • /
    • pp.57-64
    • /
    • 1986
  • 우라늄, 플루토늄 및 그 자핵종(子核種)으로부터 방출(放出)되는 저(低)에너지감마선(線) 또는 저(低)에너지영역(領域)의 X-선(線)스펙트럼으로부터의 필름배지 개인피폭선량해석(個人被曝線量解析) 및 평가(評價)에 필요(必要)한 기술자료(技術資料)를 제공(提供)하였다. 필름배지는 한국핵연료개발공단(韓國核燃料開發公團)(현(現) 한국(韓國)에너지연구소(硏究所))에서 개발(開發)한 것이며, 저(低)에너지표준선원(標準線源)은 방사선량강도(放射線量强度)의 손실(損失)을 최소(最少)로 유지(維持)하면서 가능(可能)한 한 X-선(線)스펙트럼폭(幅)을 금속(金屬)필터로 좁게 줄인 X-선(線)을 이용(利用)하였다. 그 결과(結果) 얻은 X-선(線)에너지는 49 keV, 154 keV 및 256 keV 이었으며, 이 값은 Kramer의 이론적계산결과(理論的計算結果)와 잘 일치(一致)하였다. 이들 에너지 군별(群別) X-선(線)의 필름광학밀도(光學密度)와 선량(線量)과의 관계(關係)는 Matrix 법(法)으로 해석(解析)하여 측정광학밀도(測定光學密度)로부터 저(低)에너지 X-선(線)의 개인피폭선량(個人被曝線量)을 직접(直接) 환산(換算)할 수 있게 되었다. 이 결과(結果)는 국내(國內) 방사선작업(放射線作業) 종사자(從事者)들의 개인피폭선량측정자료(個人被曝線量測定資料)의 균질성(均質性) 향상(向上)에 기여(寄與)하게 될 것이다.

  • PDF

SHOCK ACCELERATION MODEL WITH POSTSHOCK TURBULENCE FOR GIANT RADIO RELICS

  • Kang, Hyesung
    • 천문학회지
    • /
    • 제50권4호
    • /
    • pp.93-103
    • /
    • 2017
  • We explore the shock acceleration model for giant radio relics, in which relativistic electrons are accelerated via diffusive shock acceleration (DSA) by merger-driven shocks in the outskirts of galaxy clusters. In addition to DSA, turbulent acceleration by compressive MHD modes downstream of the shock are included as well as energy losses of postshock electrons due to Coulomb scattering, synchrotron emission, and inverse Compton scattering off the cosmic background radiation. Considering that only a small fraction of merging clusters host radio relics, we favor a reacceleration scenario in which radio relics are generated preferentially by shocks encountering the regions containing low-energy (${\gamma}_e{\leq}300$) cosmic ray electrons (CRe). We perform time-dependent DSA simulations of spherically expanding shocks with physical parameters relevant for the Sausage radio relic, and calculate the radio synchrotron emission from the accelerated CRe. We find that significant level of postshock turbulent acceleration is required in order to reproduce broad profiles of the observed radio flux densities of the Sausage relic. Moreover, the spectral curvature in the observed integrated radio spectrum can be explained, if the putative shock should have swept up and exited out of the preshock region of fossil CRe about 10 Myr ago.

Interferometric Monitoring of Gamma-Ray Bright AGNs: 4C +28.07 and Its Synchrotron Self-Absorption Spectrum

  • Myoung-Seok Nam;Sang-Sung Lee;Whee Yeon Cheong
    • 천문학회지
    • /
    • 제56권2호
    • /
    • pp.231-252
    • /
    • 2023
  • We present the analysis results of the simultaneous multifrequency observations of the blazar 4C +28.07. The observations were conducted by the Interferometric Monitoring of Gamma-ray Bright Active Galactic Nuclei (iMOGABA) program, which is a key science program of the Korean Very Long Baseline Interferometry (VLBI) Network (KVN). Observations of the iMOGABA program for 4C +28.07 were conducted from 16 January 2013 (MJD 56308) to 13 March 2020 (MJD 58921). We also used γ-ray data from the Fermi Large Array Telescope (Fermi-LAT) Light Curve Repository, covering the energy range from 100 MeV to 100 GeV. We divided the iMOGABA data and the Fermi-LAT data into five periods from 0 to 4, according to the prosody of the 22 GHz data and the presence or absence of the data. In order to investigate the characteristics of each period, the light curves were plotted and compared. However, a peak that formed a hill was observed earlier than the period of a strong γ-ray flare at 43-86 GHz in period 3 (MJD 57400-58100). Therefore, we assumed that the minimum total CLEANed flux density for each frequency was quiescent flux (Sq) in which the core of 4C +28.07 emitted the minimum, with the variable flux (Svar) obtained by subtracting Sq from the values of the total CLEANed flux density. We then compared the variability of the spectral indices (α) between adjacent frequencies through a spectral analysis. Most notably, α22-43 showed optically thick spectra in the absence of a strong γ-ray flare, and when the flare appeared, α22-43 became optically thinner. In order to find out the characteristics of the magnetic field in the variable region, the magnetic field strength in the synchrotron self-absorption (BSSA) and the equipartition magnetic field strength (Beq) were obtained. We found that BSSA is largely consistent with Beq within the uncertainty, implying that the SSA region in the source is not significantly deviated from the equipartition condition in the γ-ray quiescent periods.

Statistical Analysis of Count Rate Data for On-line Seawater Radioactivity Monitoring

  • Lee, Dong-Myung;Cong, Binh Do;Lee, Jun-Ho;Yeo, In-Young;Kim, Cheol-Su
    • Journal of Radiation Protection and Research
    • /
    • 제44권2호
    • /
    • pp.64-71
    • /
    • 2019
  • Background: It is very difficult to distinguish between a radioactive contamination source and background radiation from natural radionuclides in the marine environment by means of online monitoring system. The objective of this study was to investigate a statistical process for triggering abnormal level of count rate data measured from our on-line seawater radioactivity monitoring. Materials and Methods: Count rate data sets in time series were collected from 9 monitoring posts. All of the count rate data were measured every 15 minutes from the region of interest (ROI) for $^{137}Cs$ ($E_{\gamma}=661.6keV$) on the gamma-ray energy spectrum. The Shewhart ($3{\sigma}$), CUSUM, and Bayesian S-R control chart methods were evaluated and the comparative analysis of determination methods for count rate data was carried out in terms of the false positive incidence rate. All statistical algorithms were developed using R Programming by the authors. Results and Discussion: The $3{\sigma}$, CUSUM, and S-R analyses resulted in the average false positive incidence rate of $0.164{\pm}0.047%$, $0.064{\pm}0.0367%$, and $0.030{\pm}0.018%$, respectively. The S-R method has a lower value than that of the $3{\sigma}$ and CUSUM method, because the Bayesian S-R method use the information to evaluate a posterior distribution, even though the CUSUM control chart accumulate information from recent data points. As the result of comparison between net count rate and gross count rate measured in time series all the year at a monitoring post using the $3{\sigma}$ control charts, the two methods resulted in the false positive incidence rate of 0.142% and 0.219%, respectively. Conclusion: Bayesian S-R and CUSUM control charts are better suited for on-line seawater radioactivity monitoring with an count rate data in time series than $3{\sigma}$ control chart. However, it requires a continuous increasing trend to differentiate between a false positive and actual radioactive contamination. For the determination of count rate, the net count method is better than the gross count method because of relatively a small variation in the data points.

Measuring and unfolding fast neutron spectra using solution-grown trans-stilbene scintillation detector

  • Nguyen Duy Quang;HongJoo Kim;Phan Quoc Vuong;Nguyen Duc Ton;Uk-Won Nam;Won-Kee Park;JongDae Sohn;Young-Jun Choi;SungHwan Kim;SukWon Youn;Sung-Joon Ye
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.1021-1030
    • /
    • 2023
  • We propose an overall procedure for measuring and unfolding fast neutron spectra using a trans-stilbene scintillation detector. Detector characterization was described, including the information on energy calibration, detector resolution, and nonproportionality response. The digital charge comparison method was used for the investigation of neutron-gamma Pulse Shape Discrimination (PSD). A pair of values of 600 ns pulse width and 24 ns delay time was found as the optimized conditions for PSD. A fitting technique was introduced to increase the trans-stilbene Proton Response Function (PRF) by 28% based on comparison of the simulated and experimental electron-equivalent distributions by the Cf-252 source. The detector response matrix was constructed by Monte-Carlo simulation and the spectrum unfolding was implemented using the iterative Bayesian method. The unfolding of simulated and measured spectra of Cf-252 and AmBe neutron sources indicates reliable, stable and no-bias results. The unfolding technique was also validated by the measured cosmic-ray induced neutron flux. Our approach is promising for fast neutron detection and spectroscopy.