• Title/Summary/Keyword: Gamma Detection

Search Result 542, Processing Time 0.027 seconds

Measurement and Monte Carlo Simulation evaluation of a Compton Continuum Suppression with low level soil Sample (저준위 토양시료를 이용한 콤프턴 연속체 억제의 측정 및 몬테카롤로 시뮬레이션 평가)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.123-131
    • /
    • 2018
  • This study compared PENELOPE with measured values from low energy peak to high energy peak to reduce peak to compton ratio and continuum background spectrum using $^{60}Co$, $^{137}Cs$ and mixed volume source. In addition, the change in backscattering and compton edge efficiency was compared with that of PENELOPE through changes in the vicinity of low energy. The results from the mixed volume source are applied to the soil samples to determine how much the minimum detection limits of the soil samples are reduced in the suppression and unsuppressed mode. The compton suppression of the low energy region of $^{60}CO$ (1,173 keV) was considerable, and the Compton edge RF for the $^{137}Cs$ (661 keV) peak was 2.8. In particular, the $^{60}Co$ source emits coincidence gamma rays of 1,173.2 keV and 1,332.5 keV, so compton inhibition was reduced by approximately 21%. RF of compton edges of 1,173 keV and 1,332 keV emitted from a $^{60}Co$ source was 3.2 and 3.4, and the peak to compton edge ratio was improved to 8: 1. And Compared with Penelope, the uncertainty was well within 2%. In compton unsuppressed mode, MDA values of 661 keV, 1,173 keV and 1,332 keV were 0.535, 0.173 and 0.136 Bq/kg, respectively, but decreased in compton suppressed mode to 0.121, 0.00826 and 0.00728 Bq/kg. Thus, Compton suppressed could reduce the background radioactivity and the radioactivity contained in the detector itself.

Quantitation of Hepatic and Extrahepatic $^{99m}Tc-Tin$ Colloid Uptake in the Hepatocellular Diseases (간세포성 질환에서의 간 및 간외 $^{99m}Tc-Tin$ Colloid 섭취의 정량분석)

  • Park, Young-Ha;Kim, Choon-Yul;Kim, Sung-Hoon;Park, Seog-Hee;Park, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.1
    • /
    • pp.9-16
    • /
    • 1987
  • It is well-known that hepatic scintigraphv have been found to be less sensitive and specific in the detection of the diffuse hepatocellular diseases than that of the space-occupying lesions. To obtain the higher diagnostic specificity and sensitivity, we, using the computer quantitation, have attempted to analyze hepatic and extrahepatic $^{99m}Tc-tin$ colloid uptake patterns in various diffuse hepatocellular diseases retrospectively. The studied groups consisted of 116 cases of normal, 67 cases of acute hepatitis, 112 cases of chronic hepatitis, 61 cases of liver cirrhosis, 47 cases of fatty liver, 12 cases of hepatoma and 9 cases of metastasis, making total 424 cases. Scintigraphic imagings were obtained in the anterior, right lateral and posterior projections using high-resolution collimation, and simultaneously these gamma data were acquisited into the computer system. Both large region of interest (ROI) using light pen and ROI computer program were placed over right lobe, left lobe of liver, spleen and cardiac blood pool. Total counts in ROI were divided by the number of pixels in the ROI, and mean count rate per pixels calculated. Mean right-lobe counts were divded by mean-left lobe counts to determine right-to-left hepatic lobe ratio and mean spleen counts were divided by mean liver counts to determine spleen to liver ratio. The results were as follows. 1) Of 424 cases, 292 were male and 132 were female. The majority of age distribution was in $30\sim49$ (54.5%). 2) Inter-observer between two independant operators and inter-method between drawing by light-pen and ROI computer program variations were not significant. 3) The uptake count values (per pixel) determined at each area in normal group were $106.53{\pm}18.35$ in right lobe, $79.00{\pm}13.82$ in left lobe, $17.52{\pm}8.31$ in spleen and $8.09{\pm}3.43$ in cardiac blood pool. 4) In liver cirrhosis, right lobe uptake was decreased but spleen and cardiac blood pool uptakes were increased (p<0.01). 5) Right-to-left hepatic lobe uptake ratio was $1.37{\pm}0.24$ in normal group and significantly low in chronic hepatitis, liver cirrhosis and fatty liver, and more or less low in acute hepatitis. 6) Spleen-to-right hepatic lobe uptake ratio was $0.17{\pm}0.09$ in normal group and high in chronic hepatitis and liver cirrhosis. 7) The computer-quantitation of hepatic and extrahepatic uptake patterns thought to be sensitive and useful method in the interpretation of liver scintigram.

  • PDF

Detection of Atherosclerotic Lesion with $^{99m}Tc-LDL$ Scintigraphy ($^{99m}Tc-LDL$ (Low Density Lipoprotein)신티그라피를 이용한 동맥경화병소 진단)

  • Kim, Deog-Yoon;Koh, Eun-Mi;Woo, Jeong-Taek;Kim, Sung-Woon;Yang, In-Myung;Kim, Jin-Woo;Kim, Young-Seol;Kim, Kwang-Won;Choi, Young-Kil
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.257-264
    • /
    • 1992
  • Diagnostic approaches such as angiography, ultrasound, computed tomography and nuclear magnetic resonance have limitation for contributing to the early clinical diagnosis of atherosclerosis. Recently, $^{99m}Tc-labelled$ low density lipoprotein was developed to detect early atherosclerotic lesion by external imaging with gamma camera. To determine whether $^{99m}Tc-LDL$ scintigraphy can visualize the active atherosclerotic lesion, rabbits were injected with $^{99m}Tc-LDL$, 3 months after feeding dietary fat (lanolin) and we obtained following results. 1) Labelling efficiency of $^{99m}Tc-LDL$ was $79\sim88%$. 2) Biodistribution study of normal rabbits with $^{99m}Tc-LDL$ revealed the high activities in spleen, adrenal gland, liver, kidney which are major organs of high metabolic rate of LDL. 3) Three months after feeding lanolin, serum cholesterol was markedly increased from $74{\pm}17mg/dl$ to $979{\pm}153mg/dl$ and histologic study of aorta after sacrificing the rabbit demonstrated marked atherosclerotic changes. 4) Atherosclerotic lesion of abdominal aorta which was confirmed with histologic study could be demonstrated in $^{99m}Tc-LDL$ scintigraphy after feeding lanolin for 3 months. In conclusion, the results of this preliminary investigation suggest that it may be possible to image active atheromatous lesion with $^{99m}Tc-LDL$. It is anticipated that this promising agent may allow the in vivo monitoring of preclinical atherosclerotic lesions and may be useful to evaluate the metabolic pathway of LDL in humans.

  • PDF

Determination of radiolysis products in Tri-Octyl Amine by high performance liquid chromatography-mass spectrometer (HPLC-MS에 의한 Tri-Octyl Amine(TOA)의 방사선 분해산물 정량)

  • Yang, Han-Beom;Lee, Eil-Hee;Moon, Hyung-Sil
    • Analytical Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.201-205
    • /
    • 2005
  • Tri-octyl amine (TOA) is used in solvent extraction process for radioactive waste. This compound may be degraded to di-octyl amine (DOA), mono-octyl amine (MOA) by radioactive materials. Amount of TOA, DOA and MOA in TOA must be monitored because they production of these compounds means degradation of which leads to a decrease in the extraction yield. Retention behavior for TOA, DOA and MOA are studied with Phenomenex LUNA-$C_{18}$ ($4.6mm{\times}25cm$) analytical column and $CH_3OH:H_2O$ (50 mmol $CH_3COONH_4$) eluent by liquid chromatography. Optimum condition for these compounds is $CH_3OH:H_2O$ (50 mmol $CH_3COONH_4$) = 85 : 15 ratio. TOA, DOA and MOA compounds is well separated within 20 minute. Dynamic range is $30{\sim}160{\mu}g/mL$ for TOA, $5{\sim}100{\mu}g/mL$ for DOA and $0.1{\sim}5{\mu}g/mL$ for MOA, respectively. The detection limit are $0.1{\mu}g/mL$ for TOA, $1{\mu}g/mL$ for DOA (in SCAN mode) and $0.1{\mu}g/mL$ for MOA (in SIM mode) in this system with $20{\mu}L$ sample loop.

Organotin Compounds Act as Inhibitor of Transcriptional Activation with Human Estrogen Receptor

  • Cho, Eun-Min;Lee, Haeng-Seog;Moon, Jeong-Suk;Kim, Im-Soon;Sim, Sang-Hyo;Ohta, Akinori
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.3
    • /
    • pp.378-384
    • /
    • 2012
  • In aquatic invertebrates, particularly marine gastropods, organotin compounds induce irreversible sexual abnormality in females, which is termed imposex, at very low concentrations. Organotin compounds are agonists for nuclear receptors such as RXRs and $PPAR{\gamma}$. However, the imposex phenomenon has not been reported to act as an antagonist on estrogen receptors in other species, including vertebrates and invertebrates. In order to gain insights into the antagonistic activity of organotin compounds on estrogen receptors (ERs), we examined the inhibitive effect of these compounds on estradiol-dependent ${\beta}$-galactosidase activity using the yeast two-hybrid detection system consisting of a combination of the human estrogen receptor ($hER{\beta}$) ligand-binding domain and the co-activator steroid receptor co-activator-1 (SRC1). Tributyltin-hydroxide (TBT-OH) and triphenyltin-chlorine (TPT-Cl) exhibited an inhibitive effect on $E_2$-dependent transcriptional activity, similar to antagonistic chemicals such as 4-hydroxytamoxifen (OHT) or ICI 182,780, at a very low concentration of $10^{-14}$ M TBT or $10^{-10}$ M TPT, respectively. The yeast growth and transcriptional activity with transcriptional factor GAL4 did not exhibit any effect at the tested concentration of TBT or TPT. Moreover, the yeast two-hybrid system using the interaction between p53 and the T antigen of SV40 large did not describe any effect at the tested concentration of OHT or ICI 182,780. However, the interaction between p53 and T antigen was inhibited at a TBT or TPT concentration of $10^{-9}$ M, respectively. These results indicate that TBT and TPT act as inhibitors of ER-dependent reporter gene transcriptional activation and of the interaction between $hER{\beta}$ LBD and the co-activator SRC1 in the yeast two-hybrid system. Consequently, our data could partly explain the occurrence of organotin compound-induced imposex on the endocrine system of mammals, including humans.

Effect of Diethyldithiocarbamate on Radiation-induced Learning and Memory Impairment in Mouse (방사선 유도 학습기억 장애에 대한 diethyldithiocarbamate의 효과)

  • Jang, Jong-Sik;Kim, Jong-Choon;Moon, Chang-Jong;Jung, U-Hee;Jo, Sung-Kee;Kim, Sung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.3
    • /
    • pp.123-128
    • /
    • 2012
  • Evidence suggests that even low-dose irradiation can lead to progressive cognitive decline and memory deficits, which implicates, in part, hippocampal dysfunction in both humans and experimental animals. This study examined whether diethyldithiocarbamate (DDC) could attenuate memory impairment, using passive avoidance and object recognition test, and suppression of hippocampal neurogenesis, using the TUNEL assay and immunohistochemical detection with markers of neurogenesis (Kiel 67 (Ki-67) and doublecortin (DCX)) in adult mice treated with gamma radiation (0.5 or 2 Gy). DDC was administered intraperitonially at a dosage of 1,000 $mg{\cdot}kg^{-1}$ of body weight at 30 min. before irradiation. In passive avoidance and object recognition memory test, the mice, trained for 1 day after acute irradiation (2 Gy) showed significant memory deficits compared with the sham controls. The number of TUNEL-positive apoptotic nuclei in the dentate gyrus (DG) was increased 12 h after irradiation. In addition, the number of Ki-67- and DCX-positive cells were significantly decreased. DDC treatment prior to irradiation attenuated the memory defect, and blocked the apoptotic death. DDC may attenuate memory defect in a relatively low-dose exposure of radiation in adult mice, possibly by inhibiting a detrimental effect of irradiation on hippocampal neurogenesis.

A Study On Radiation Detection Using CMOS Image Sensor (CMOS 이미지 센서를 사용한 방사선 측정에 관한 연구)

  • Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.19 no.2
    • /
    • pp.193-200
    • /
    • 2015
  • In this paper, we propose the radiation measuring algorithm and the device composition using CMOS image sensor. The radiation measuring algorithm using CMOS image sensor is based on the radiation particle distinguishing algorithm projected to the CMOS image sensor and accumulated and average number of pixels of the radiation particles projected to dozens of images per second with CMOS image sensor. The radiation particle distinguishing algorithm projected to the CMOS image sensor measures the radiation particle images by dividing them into R, G and B and adjusting the threshold value that distinguishes light intensity and background from the particle of each image. The radiation measuring algorithm measures radiation with accumulated and average number of radiation particles projected to dozens of images per second with CMOS image sensor according to the preset cycle. The hardware devices to verify the suggested algorithm consists of CMOS image sensor and image signal processor part, control part, power circuit part and display part. The test result of radiation measurement using the suggested CMOS image sensor is as follows. First, using the low-cost CMOS image sensor to measure radiation particles generated similar characteristics to that from measurement with expensive GM Tube. Second, using the low-cost CMOS image sensor to measure radiation presented largely similar characteristics to the linear characteristics of expensive GM Tube.

LATEST RESULTS OF THE MAXI MISSION

  • MIHARA, TATEHIRO
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.559-563
    • /
    • 2015
  • Monitor of All-sky X-ray Image (MAXI) is a Japanese X-ray all-sky surveyer mounted on the International Space Station (ISS). It has been scanning the whole sky since 2009 during every 92-minute ISS rotation. X-ray transients are quickly found by the real-time nova-search program. As a result, MAXI has issued 133 Astronomer's Telegrams and 44 Gamma-ray burst Coordinated Networks so far. MAXI has discovered six new black holes (BH) in 4.5 years. Long-term behaviors of the MAXI BHs can be classified into two types by their outbursts; a fast-rise exponential-decay type and a fast-rise flat-top one. The slit camera is suitable for accumulating data over a long time. MAXI issued a 37-month catalog containing 500 sources above a ~0.6 mCrab detection limit at 4-10 keV in the region ${\mid}{b}{\mid}$ > $10^{\circ}$. The SSC instrument utilizing an X-ray CCD has detected diffuse soft X-rays extending over a large solid angle, such as the Cygnus super bubble. MAXI/SSC has also detcted a Ne emission line from the rapid soft X-ray nova MAXI J0158-744. The overall shapes of outbursts in Be X-ray binaries (BeXRB) are precisely observed with MAXI/GSC. BeXRB have two kinds of outbursts, a normal outburst and a giant one. The peak dates of the subsequent giant outbursts of A0535+26 repeated with a different period than the orbital one. The Be stellar disk is considered to either have a precession motion or a distorted shape. The long-term behaviors of low-mass X-ray binaries (LMXB) containing weakly magnetized neutron stars are investigated. Transient LMXBs (Aql X-1 and 4U 1608-52) repeated outbursts every 200-1000 days, which is understood by the limit-cycle of hydrogen ionization states in the outer accretion disk. A third state (very dim state) in Aql X-1 and 4U 1608-52 was interpreted as the propeller effect in the unified picture of LMXB. Cir X-1 is a peculiar source in the sense that its long-term behavior is not like typical LMXBs. The luminosity sometimes decreases suddenly at periastron. It might be explained by the stripping of the outer accretion disk by a clumpy stellar wind. MAXI observed 64 large flares from 22 active stars (RS CVns, dMe stars, Argol types, young stellar objects) over 4 years. The total energies are $10^{34}-10^{36}$ erg $s^{-1}$. Since MAXI can measure the spectrum (temperature and emission measure), we can estimate the size of the plasma and the magnetic fields. The size sometimes exceeds the size of the star. The magnetic field is in the range of 10-100 gauss, which is a typical value for solar flares.

Quantitative Comparison of Radiation-induced 2-Alkylcyclobutanones from Irradiated Beef and Chicken (쇠고기와 닭고기로부터 방사선 조사에 의해 유도된 2-Alkylcyclobutanone류의 정량적 비교 분석)

  • Kim, Kyong-Su;Kim, Eun-Ah;Lee, Hae-Jung;Park, Eun-Ryeong;Yang, Jae-Seung;Byun, Myung-Woo;Kim, Sun-Min;Lee, Myung-Yul
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.1495-1502
    • /
    • 1999
  • Gamma-irradiated beef and chicken at the dose levels of 0.5 to 10 kGy were subjected to the detection of radiation-induced 2-alkylcyclobutanones whether irradiated or not. Radiation-induced 2-alkylcyclobutanones were extracted from beef and chicken fats, separated by florisil column chromatography and identified with GC/MS method by selected ion monitoring(SIM). When beef and chicken were irradiated, 2-dodecylcyclobutanone, 2-tetradecylcyclobutanone and 2-(5'-tetradecenyl)cyclobutanone were formed from palmitic, stearic and oleic acids. Concentrations of 2-alkylcyclobutanones were linearly increased with the dose levels of irradiation and depended upon the composition of fatty acids in beef and chicken. Radiation-induced 2-alkylcyclobutanones in irradiated beef and chicken were remarkably detected at 1 kGy and over, while these compounds were not detected in non-irradiated samples. The concentrations of radiationinduced 2-alkylcyclobutanones were relatively constant during 6 months.

  • PDF

Analysis of EDCs by Mass Spectrometry and their Removal by Membrane Filtrations (질량분석법에 의한 내분비계 장애물질의 분석과 막 여과에 의한 제거)

  • Kim Tae-Uk;Yeon Kyeong-Ho;Cho Jaeweon;Moon Seung-Hyeon
    • Membrane Journal
    • /
    • v.15 no.4
    • /
    • pp.297-309
    • /
    • 2005
  • As a number of potential endocrine disrupting compounds (EDCs) are released into the environment, recently growing attention has been drawn to them. Therefore sensitive and reliable analytical methods are essential to monitor those compounds. In this study, complementary CC-MS and LC-MS were employed to analyze the endocrine disrupters, and the results of two methods were compared for di(2-ethylhexyl)phthalate (DEHP), benzylbutylphthalate (BBP), pentachlorophenol (PCP), and 4,4'-Isopropylidenediphenol (Bisphenol-A, or BPA). The results indicate that it was possible to lower the detection limits of EDCs by LC-MS. Also, LC-MS enabled to identify the EDCs as almost intact molecules. Furthermore, this study presented a nanofiltration membrane (MWCO 250) and a ultrafiltration membrane (MWCO 1,000) filtration system as methods far removing EDCs from drinking water containing $\gamma$-BHC, p,p'-DDE, BBP, p,p'-DDT, DEHP, PCP, and BPA. Cross-flow type nanofiltrations showed $100\%$ removal of EDCs, and the result implies that MWCO 250 nanofilter was sufficient for treatment of EDCs. The ratio of permeate flux to mass transfer coefficient of nanofiltration, high flux ultrafiltration, and low flux ultrafiltration with ultrapure water were 0.67, 3.4, and 0.44, respectively. It was found that nanofiltration and low flux ultrafiltration were operated at a diffusion dominant condition, and the high flux ultrafiltration was operated at a convection dominant condition. Furthermore, a diffusion dominant process attained reasonable rejection of EDCs. The removal in the ultrafiltration was depending on the molecular weight of an EDC, and the filtration was governed by diffusion-dominant hydrodynamic conditions.